Emerson Process Management MMI-20015440 manual
- Ver online ou baixar oubaixar o manual
- 76 páginas
- 1.43 mb
Ir para a página of
Manuais similares
-
Marine Instruments
Emerson Process Management ETC01035
74 páginas 2.84 mb -
Marine Instruments
Emerson Process Management 402
8 páginas 0.74 mb -
Marine Instruments
Emerson Process Management 3144P
164 páginas 4.23 mb -
Marine Instruments
Emerson Process Management 644R
32 páginas 2.35 mb -
Marine Instruments
Emerson Process Management 4.21
40 páginas 1.34 mb -
Marine Instruments
Emerson Process Management 402VP
8 páginas 0.74 mb -
Marine Instruments
Emerson Process Management MMI-20015440
76 páginas 1.43 mb -
Marine Instruments
Emerson Process Management 644H
32 páginas 2.35 mb
Bom manual de uso
As regras impõem ao revendedor a obrigação de fornecer ao comprador o manual com o produto Emerson Process Management MMI-20015440. A falta de manual ou informações incorretas fornecidas ao consumidor são a base de uma queixa por não conformidade do produto com o contrato. De acordo com a lei, pode anexar o manual em uma outra forma de que em papel, o que é frequentemente utilizado, anexando uma forma gráfica ou manual electrónicoEmerson Process Management MMI-20015440 vídeos instrutivos para os usuários. A condição é uma forma legível e compreensível.
O que é a instrução?
A palavra vem do latim "Instructio" ou instruir. Portanto, no manual Emerson Process Management MMI-20015440 você pode encontrar uma descrição das fases do processo. O objetivo do manual é instruir, facilitar o arranque, a utilização do equipamento ou a execução de determinadas tarefas. O manual é uma coleção de informações sobre o objeto / serviço, um guia.
Infelizmente, pequenos usuários tomam o tempo para ler o manual Emerson Process Management MMI-20015440, e um bom manual não só permite conhecer uma série de funcionalidades adicionais do dispositivo, mas evita a formação da maioria das falhas.
Então, o que deve conter o manual perfeito?
Primeiro, o manual Emerson Process Management MMI-20015440 deve conte:
- dados técnicos do dispositivo Emerson Process Management MMI-20015440
- nome do fabricante e ano de fabricação do dispositivo Emerson Process Management MMI-20015440
- instruções de utilização, regulação e manutenção do dispositivo Emerson Process Management MMI-20015440
- sinais de segurança e certificados que comprovam a conformidade com as normas pertinentes
Por que você não ler manuais?
Normalmente, isso é devido à falta de tempo e à certeza quanto à funcionalidade específica do dispositivo adquirido. Infelizmente, a mesma ligação e o arranque Emerson Process Management MMI-20015440 não são suficientes. O manual contém uma série de orientações sobre funcionalidades específicas, a segurança, os métodos de manutenção (mesmo sobre produtos que devem ser usados), possíveis defeitos Emerson Process Management MMI-20015440 e formas de resolver problemas comuns durante o uso. No final, no manual podemos encontrar as coordenadas do serviço Emerson Process Management na ausência da eficácia das soluções propostas. Atualmente, muito apreciados são manuais na forma de animações interessantes e vídeos de instrução que de uma forma melhor do que o o folheto falam ao usuário. Este tipo de manual é a chance que o usuário percorrer todo o vídeo instrutivo, sem ignorar especificações e descrições técnicas complicadas Emerson Process Management MMI-20015440, como para a versão papel.
Por que ler manuais?
Primeiro de tudo, contem a resposta sobre a construção, as possibilidades do dispositivo Emerson Process Management MMI-20015440, uso dos acessórios individuais e uma gama de informações para desfrutar plenamente todos os recursos e facilidades.
Após a compra bem sucedida de um equipamento / dispositivo, é bom ter um momento para se familiarizar com cada parte do manual Emerson Process Management MMI-20015440. Atualmente, são cuidadosamente preparados e traduzidos para sejam não só compreensíveis para os usuários, mas para cumprir a sua função básica de informação
Índice do manual
-
Página 1
Inst allation and Configuration Manual P/N MMI-20015440, Rev . AA July 2009 Micro Motion ® 7827 Digit al V iscosity Meter Short and Long S tem V ersions[...]
-
Página 2
©2009, Micro Motion, Inc . All rights reserved. Micro Motion is a re gistered trade name o f Micro Motion, I nc., Boulder , Colorado . The Micro Motion and Emerson log os are trademarks and service mar ks of Emerson Electric Co. All other trademarks are property of their respective owners. Micro Motion pursues a pol icy of continuous developmen t [...]
-
Página 3
Installation and Conf iguration Manual i Contents Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Safety guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 About the m eter . . . . . . . . . . . . . . . . . . . . . [...]
-
Página 4
ii Micro Motion 7827 Digital Viscosi ty Meter Contents 4.7 Checking the installat ion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Chapter 5 Using 7950/7951 Processing Electronic s . . . . . . . . . . . . . . . . . . . . 39 5.1 Using the 79 50 / 7951 Pr ocessing Elect ronics . . . . . . . . . . . . [...]
-
Página 5
Installation and Conf iguration Manual iii Contents Appendix C Product Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 C .1 Density / temperature re lationship of hydrocarbon p roducts . . . . . . . . . . . . . . . . . . . 61 C .1.1 Crude oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]
-
Página 6
iv Micro Motion 7827 Digital Viscosi ty Meter Contents[...]
-
Página 7
Installation and Conf iguration Manual 1 Installation (Short Stem) Electrical Connecti ons Installation (Long Stem) Intro duction Chapter 1 Introduction 1.1 Safety guidelines Handle the 7827 digital viscosity meter wit h great care. • Do not drop the meter . • Do not use liquids incompatible with mater ials of const ruction. • Do not operate [...]
-
Página 8
2 Micro Motion 7827 Digital Viscosi ty Meter Introduction 1.2 About the meter 1.2.1 What is it? The 7827 meter is a digital visco sity meter , based on the prov en tuning fork technology of Micro Motion. It is an all-welded sensor designed to be mounted directly into a pipeline or i n a tank. V iscosity and density are determined from the resonanc [...]
-
Página 9
Installation and Conf iguration Manual 3 Introduction Installation (Short Stem) Electrical Connecti ons Installation (Long Stem) Intro duction 1.2.3 What is it used for? The 7827 meter is idea lly suited to applications where continuous real time m easurement o f viscosity is required. The meter is particularly suited wh ere viscosity is an indicat[...]
-
Página 10
4 Micro Motion 7827 Digital Viscosi ty Meter Introduction[...]
-
Página 11
Installation and Conf iguration Manual 5 Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intro duction Chapter 2 Installation (Short Stem) For information on i nstalling a long-stem version of the 7827 digital viscosity meter, see Chapter 3. 2.1 Introduction There are a v ariety of external f actors that af fect the abili[...]
-
Página 12
6 Micro Motion 7827 Digital Viscosi ty Meter Installation (Short Stem ) Factors which may adv ersely affect the rele vance of the measurements could include: • Measurement used for control purposes being made too far away from the point of control, so that the system cannot respond properly to chang es. • Measurements made on fluid which is unr[...]
-
Página 13
Installation and Conf iguration Manual 7 Installation (Short Stem ) Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intro duction This next vie w shows other pipe outlines superimposed: The smaller circle represents a 4" (100 mm) v ertical pipe, which because the 7827 meter orientatio n is constant irrespectiv e of p[...]
-
Página 14
8 Micro Motion 7827 Digital Viscosi ty Meter Installation (Short Stem ) From this, it would appear that almost e very installa tion requires a separate in situ calibration – a very undesirable situation. Th e problem is resolv ed by pro viding standard ca li bration geometries which can be used in all pipe work co nfigurations and thereby allo w [...]
-
Página 15
Installation and Conf iguration Manual 9 Installation (Short Stem ) Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intro duction 2.3.2 Meter orientatio n The meter must alwa ys be installe d horizontally , and orientated to allo w flow in the gap between the tines. This is irrespecti ve of the pipe line orientatio n, an [...]
-
Página 16
10 Micro Motion 7827 Digital Viscosi ty Meter Installation (Short Stem ) Figure 2-1 Meter orientation Note: All dr awings and dimensions given in t h e following sections ar e derived fr om detailed dimensional drawings. They ar e given he r e for pla nning purposes on ly . Befor e com mencing fabrication, r eference should alwa ys be made to the c[...]
-
Página 17
Installation and Conf iguration Manual 11 Installation (Short Stem ) Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intro duction The pock et geometry must be consistent with 2" schedule 40 tu be in both internal diameter and minimum wall thickness, such as: • Internal diameter: 2" (52. 5 mm) • W all thickn[...]
-
Página 18
12 Micro Motion 7827 Digital Viscosi ty Meter Installation (Short Stem ) Figure 2-2 Fr ee stream 1.5 " Swagelock fitting The installation will conform generally to Schedule 40 pressure ratings . The weldolet f abrication is rated to 100 Bar at ambient temperature. Note: Corr ect installation and pr essur e testing of the f itting is the r espo[...]
-
Página 19
Installation and Conf iguration Manual 13 Installation (Short Stem ) Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intro duction The pock et geometry must be consistent with 2" schedule 40 tu be in both internal diameter and minimum wall thickness, i.e.: • Internal diameter: 2.1" (52 .5 mm) • W all thickne[...]
-
Página 20
14 Micro Motion 7827 Digital Viscosi ty Meter Installation (Short Stem ) The three compression f ittings on the flo w pockets (½" drain, ¾" temp probe, and 1-½" mounting nut for the meter) are rated to abo ve the w orking pre ssure of the flo w pocket. The f ittings may be Swagelok or P arker; both are used in manuf acture. The fi[...]
-
Página 21
Installation and Conf iguration Manual 15 Installation (Short Stem ) Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intro duction Y ou must first select a location which serv es the app lication objecti ve; e.g. inst alled close to the point of control. Then, consideration can be gi ven to flui d conditioning at that poi[...]
-
Página 22
16 Micro Motion 7827 Digital Viscosi ty Meter Installation (Short Stem ) Where it is necessary to install the viscometer in a by-pass (either using the fr ee stream installation in a 4" diameter horizon tal by-pass, or a flow-through chamber), flow may be maintained using pressure drop, pitot scoop, or by a sample pump. Where a pu mp is u sed,[...]
-
Página 23
Installation and Conf iguration Manual 17 Installation (Short Stem ) Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intro duction 2.5 T ypical installations The follo wing diagrams illustrate some typical solu tions for line viscosity me asurement, simple base viscosity referral a nd base viscosity using temperature cont[...]
-
Página 24
18 Micro Motion 7827 Digital Viscosi ty Meter Installation (Short Stem ) Figure 2-3 Jacketed pipeline installation Alternati vely , the viscometer can be installed in a by-pass. By ensuring that the sample is mixed where the by-pass draws of f the main pipeline, it is not necessary to discontin ue the main pipe line jacket. This is sho wn belo w . [...]
-
Página 25
Installation and Conf iguration Manual 19 Installation (Short Stem ) Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intro duction 2.5.2 Flow-through ch amber The diagram belo w shows the use of a flo w-through chamber . This provides a compact installation and is particularly suited to flo ws of contaminated fluids, sinc[...]
-
Página 26
20 Micro Motion 7827 Digital Viscosi ty Meter Installation (Short Stem )[...]
-
Página 27
Installation and Conf iguration Manual 21 Installation (Short Stem) Electrical Connecti ons Installation (Long Stem) Intro duction Chapter 3 Installation (Long Stem) For information on i nstalling a short-stem version of the 7827 di gital viscos ity meter, see Chapter 2. 3.1 Introduction There are a v ariety of external f actors that af fect the ab[...]
-
Página 28
22 Micro Motion 7827 Digital Viscosi ty Meter Installation (Long Stem ) The term achiev able accuracy can be used to describe a measure of the product quality that can be realistically obtained from a proc ess system. It is a function of measurement accuracy , stability and system response. High accuracy alone is no guarantee of good product qualit[...]
-
Página 29
Installation and Conf iguration Manual 23 Installation (Long Stem ) Installation (Short Stem) Electrical Connecti ons Installation (Long Stem) Intro duction 3.2.3 Entrained ga s Gas pock ets can disrup t the measuremen t. A brief disruption i n the signal caused by transient gas pockets can be ne gated in the int ernal signal condition ing software[...]
-
Página 30
24 Micro Motion 7827 Digital Viscosi ty Meter Installation (Long Stem ) Figure 3-2 Keep ing tines away from the tank wall (Open-tank) 3. K e ep the tines immersed in fluid (see Figure 3-3). Figure 3-3 Keeping tines immersed (Open-tank ) 4. K e ep tines aw ay from objects and disturbed flo w (see Figure 3-4).[...]
-
Página 31
Installation and Conf iguration Manual 25 Installation (Long Stem ) Installation (Short Stem) Electrical Connecti ons Installation (Long Stem) Intro duction Figure 3-4 Keep ing tines away from objects and disturbed flow (open tan k) 5. If there is flo w , align the tines such that the fl o w is directed to wards the gap between the tines (see Figur[...]
-
Página 32
26 Micro Motion 7827 Digital Viscosi ty Meter Installation (Long Stem ) Figure 3-6 A v oid deposit build-up (Open-tank ) 3.4 Closed-tank installation 1. F or closed-tank installations, the long-stemmed 7827 meter should ha ve a f actory fitted flange attachment. (This is an option that is specif ied as a code in the part nu mber – see a list of t[...]
-
Página 33
Installation and Conf iguration Manual 27 Installation (Long Stem ) Installation (Short Stem) Electrical Connecti ons Installation (Long Stem) Intro duction Figure 3-8 Use of standoff section ( not supplied)(closed-tank) 3. K e ep the tines immersed in fluid (see Figure 3-9). Figure 3-9 Keeping tines immers ed (closed tank) 4. K e ep the tines a wa[...]
-
Página 34
28 Micro Motion 7827 Digital Viscosi ty Meter Installation (Long Stem ) Figure 3-11 Allowing for tank lid flexing (closed tank) 6. K e ep tines aw ay from objects and disturbed flo w (see Figure 3-12). Figure 3-12 Keeping tines away from ob jects and disturbed flow (Close d-tank) 7. If there is flo w , align the tines such that the fl o w is direct[...]
-
Página 35
Installation and Conf iguration Manual 29 Installation (Long Stem ) Installation (Short Stem) Electrical Connecti ons Installation (Long Stem) Intro duction Figure 3-13 Aligning the tines in flow (closed tank) 8. K eep away from deposit b uild-up (see Figure 3-14). Figure 3-14 Avoid deposit build-up (closed tank) 3.5 Calibration The log-stemmed 782[...]
-
Página 36
30 Micro Motion 7827 Digital Viscosi ty Meter Installation (Long Stem ) 5. Once the system has stabilized and is leak fre e, fit the insulation material, remembering also to insulate any flanges.[...]
-
Página 37
Installation and Conf iguration Manual 31 Electrical Connectio ns Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intro duction Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intr oduction Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intr oduction Installation (Sho[...]
-
Página 38
32 Micro Motion 7827 Digital Viscosi ty Meter Electrical Connectio ns 4.3 Installation and safety in hazardous areas The 7827 meter is e xplosi ve proof and can be in stalled in a hazardous area without the use of intrinsically safe barriers (or isolators). Ho wev e r , it is still necessary to observe the rules of compliance with current standards[...]
-
Página 39
Installation and Conf iguration Manual 33 Electrical Connectio ns Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intro duction Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intr oduction Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intr oduction Installation (Sho[...]
-
Página 40
34 Micro Motion 7827 Digital Viscosi ty Meter Electrical Connectio ns 4.6 Connecting the 78 27 to a 795x series com puter 4.6.1 Over view The 7827 requires a 79 5x series computer (Signal Con verter or Flo w Computer) with liquid-based application software for it to be functional. This section provides a guide to possible wiring connections between[...]
-
Página 41
Installation and Conf iguration Manual 35 Electrical Connectio ns Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intro duction Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intr oduction Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intr oduction Installation (Sho[...]
-
Página 42
36 Micro Motion 7827 Digital Viscosi ty Meter Electrical Connectio ns Figure 4-2 Conn ecting two 7827 meters to a 7950 Flow comp uter S ign al - PR T S ign al - PR T S ign al + PR T P ow e r + PR T P ow e r - 0V Su pp ly Si gn al + +2 4 V P o we r Su p p ly + Sig + Sup p ly - K lip p o n PL 13 / 8 7827 I n t eg r a t e d P T 1 0 0 PL 13 / 7 PL 13 /[...]
-
Página 43
Installation and Conf iguration Manual 37 Electrical Connectio ns Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intro duction Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intr oduction Installation (Short Ste m) Electrical Connections Installation (Long Stem) Intr oduction Installation (Sho[...]
-
Página 44
38 Micro Motion 7827 Digital Viscosi ty Meter Electrical Connectio ns Electrical checks Measure the current consumption an d the supply voltage at the meter ampl ifier . They should be within the follo wing limits: • Current: 40 mA to 70 mA (Measured in series at the “ SUPPL Y + ” terminal) • V oltage: 22.8 V to 25.2 V (Measured between” [...]
-
Página 45
Installation and Conf iguration Manual 39 Calibration Check General Maintenance Using 795X Processing Electronics Chapter 5 Using 7950/7951 Processing Electronics 5.1 Using the 7950 / 7951 Processing Electronics For details on connect ing the 7827 meter to the Mi cro Motion signal con verters and flo w computers, refer to the appropriate 795x op er[...]
-
Página 46
40 Micro Motion 7827 Digital Viscosi ty Meter Using 7950/7951 Pro cessing Electronics[...]
-
Página 47
Installation and Conf iguration Manual 41 Calibration Chec k General Mai ntenance Using 795X Processing Electronics Chapter 6 Calibration Check 6.1 Introduction The follo wing information details the calibration method and perfo rmance of the 7827 digital viscosity meter and co vers the follo wing: • Factory calibrat ion • In-line calibration ?[...]
-
Página 48
42 Micro Motion 7827 Digital Viscosi ty Meter Calibration Check A fourth fluid is used as an o vercheck to v erify th e calibration for each viscosity range. Each check is monitored by the Micro Motion Quality Assurance Department. 6.2.2 Density The 7827 meter is cal ibrated with in the standard shroud against T ransfer Standard instruments traceab[...]
-
Página 49
Installation and Conf iguration Manual 43 Calibration Check Calibration Chec k General Mai ntenance Using 795X Processing Electronics 6.3 In-line calibration 6.3.1 Viscosity The 7827 meter is calibrated to op erate in installations where the boundary formed by the surrounding metalwork is at a distance a way where it does not influence the viscosit[...]
-
Página 50
44 Micro Motion 7827 Digital Viscosi ty Meter Calibration Check For unstable or high-pres sure vapor liquids A pressure pykn ometer can be used. The pressure pyknometer and its asso ciated pipe work can be coupled to the pipeline so that a sa mple of the product flows through it. When equilibrium is reached, the meter density reading is note d as t[...]
-
Página 51
Installation and Conf iguration Manual 45 Calibration Check Calibration Chec k General Mai ntenance Using 795X Processing Electronics Figure 6-1 Density in-line calibration procedure Note: The values of K0' and K2' ar e now used in the general density equation in the 795x, r eplacing the original values of K0 and K2 on the calibr ation ce[...]
-
Página 52
46 Micro Motion 7827 Digital Viscosi ty Meter Calibration Check V iscosity calibration is ef fectiv ely immune to temp erature or pressure errors when operating with Ne wtonian fluids. As a general guide, T able 6-1 sho ws the accuracy of the 7827 meter: 6.4.2 Density The 7827 meter is cal ibrated for density at 20°C a nd at at mospheric pressure [...]
-
Página 53
Installation and Conf iguration Manual 47 Calibration Check Calibration Chec k General Mai ntenance Using 795X Processing Electronics Figure 6-2 Example calibration certificate f or the 7827 digital viscosity meter example example CALIBRATION CERTIFICATE 7827CBANATEABA VISCOMETER SERIAL NO : 27 1542 CAL DATE : 24 JUL08 PRESSURE TEST : 16 0 Bar VISC[...]
-
Página 54
48 Micro Motion 7827 Digital Viscosi ty Meter Calibration Check[...]
-
Página 55
Installation and Conf iguration Manual 49 Calibration Chec k General Mai ntenance Using 795X Processing Electronics Chapter 7 General Maintenance 7.1 Introduction This chapter describes which proced ures to take in the ev ent of a fault dev eloping with the 7827 digital viscosity meter system. T o use this chapter ef fecti vely , follo w the option[...]
-
Página 56
50 Micro Motion 7827 Digital Viscosi ty Meter General Maintenance 6. Check that the Signal Con verter is providing ad equate po wer to the mete r and that the Sign al Con verter itself is functioning properly . Check calibrations shoul d be carried out at specif ied intervals in order to highlight a malfunction or deterioration in meter performance[...]
-
Página 57
Installation and Conf iguration Manual 51 General Maintenance Calibration Chec k General Mai ntenance Using 795X Processing Electronics Error on indica ted density If the indicated density is in error , follow the tabl e belo w and, if necessary , refer to the other tables later in the chapter to f ind the cause of the fault. Ta b l e 7 - 1 Error c[...]
-
Página 58
52 Micro Motion 7827 Digital Viscosi ty Meter General Maintenance 7.3.2 Checking the power consumptio n A lot of information is gained fro m ch ecking the po wer consumption at vario us parts of the circuit between Signal Con verter and meter . Ta b l e 7 - 2 Error check ing for density What to c heck: What to look f or: What to c heck ne xt: Indic[...]
-
Página 59
Installation and Conf iguration Manual 53 General Maintenance Calibration Chec k General Mai ntenance Using 795X Processing Electronics 7.3.3 Checking the ins tallation The last check to be made is a physical check of the meter's installatio n and wetted parts. This means taking the 7827 meter out of the installation an d inspecting the tines [...]
-
Página 60
54 Micro Motion 7827 Digital Viscosi ty Meter General Maintenance Installation dimensions Check the ke y dimensions as specified in Chapter 2 f or your inst allation. • Y our ke y dimen sions should match those detailed in the Installation chapter f or your meter f or your mounting configuration. Product build up on the tines Product which has st[...]
-
Página 61
Installation and Conf iguration Manual 55 Safety Certification Return Policy Product Data Calculated Parameters Appendix A Calculated Parameters A.1 Introduction The follo wing information details the equations used in the Micro Motion ® si gnal con verters to translate the raw data from the meter into fl uid parameters and cov ers the following: [...]
-
Página 62
56 Micro Motion 7827 Digital Viscosi ty Meter Calculated Paramete rs A.2.2 General viscosity equation The quality fa ctor of a resonator is proportional to t he in verse square root of viscosity . T o calibrate the resonator against flui d viscosity , the following quadratic e xpression is used: η = V * ( V0 + V1.*X + V2*X 2 ) [2] Where: • η = [...]
-
Página 63
Installation and Conf iguration Manual 57 Calculated Paramete rs Safety Certification Return Policy Product Data Calculated Parameters ρ v = ρ t - [ K20 + K21*X + K22*X 2 ] [5] where: • ρ v = V iscosity-correcte d density (kg/m 3 ) • ρ t = T emperature-corrected density (kg/m 3 ) •X = 1 / Q 2 (in verse square of the quality factor) • K2[...]
-
Página 64
58 Micro Motion 7827 Digital Viscosi ty Meter Calculated Paramete rs Figure A-1 The Velocity Of S ound (V OS) / density relationship A.3.6 Density scaling Once the indicated density has been corrected for te mperature, viscosity and V OS, the result is scaled to display density in any set of units . The follo wing expressi on is used: ρ = ρ vos *[...]
-
Página 65
Installation and Conf iguration Manual 59 Safety Cer tification Safety Certification Return Policy Product Data Calculated Parameters Appendix B Safety Certification B.1 Safety certification Please contact Micro Motion if you need to ha ve copies of the latest safety certif ication for the 7827 digital viscosity meter.[...]
-
Página 66
60 Micro Motion 7827 Digital Viscosi ty Meter Safety Cer tification[...]
-
Página 67
Installation and Conf iguration Manual 61 Safety Certification Return Policy Product Data Calculated Parameters Appendix C Product Data C.1 Density / temperature rel ationship of hydrocarbon p roducts C.1.1 Crude oil C.1.2 Refined products Ta b l e C - 1 Crude oil T emp. (°C) Density (kg/m 3 ) 60 738.91 765.06 791.94 8 17.15 843.11 86 9.01 894.86 [...]
-
Página 68
62 Micro Motion 7827 Digital Viscosi ty Meter Product Data The abov e tables are deri ved from equations, which form the basis of the data in the Revised P etr oleum Measur ement T ables (IP 200, ASTM D1250 , API 2540 and ISO R91 Addendum 1). The density tempera ture relationship used is: Where: = Density at line temper ature t°C (kg/m 3 ) = Densi[...]
-
Página 69
Installation and Conf iguration Manual 63 Product Data Safety Certification Return Policy Product Data Calculated Parameters C.1.4 Density of ambient air T aken at a relati ve humidity of 50%. C.1.5 Density of water Use pure, bubble-free water . Ta b l e C - 4 Density of ambient air (in kg/m 3 ) Air Pressure Air T emperature (°C) ( m b ) 6 1 01 41[...]
-
Página 70
64 Micro Motion 7827 Digital Viscosi ty Meter Product Data C.1.6 Velocity of sound in liquids Ta b l e C - 6 Velocity of sound in liquids Liquid T emp. (t °C) V elocity of Sound (m s –1 ) Rate of Change ( m s –1 K –1 ) Acetic acid 20 1173 ---- Acetone 20 1190 –4.5 Amyl acetate 29 1173 ---- Aniline 20 1656 –4.0 Benzene 20 1320 –5.0 Bloo[...]
-
Página 71
Installation and Conf iguration Manual 65 Product Data Safety Certification Return Policy Product Data Calculated Parameters n-P entane 20 1044 –4.2 n-Prop yl acetate 26 1182 ---- T oluene 20 1320 –4.3 T urpentine 25 1225 ---- W ater (distill ed) 10 1447.2 ---- 20 1482.3 ---- 30 1509.1 ---- 50 1542.5 ---- 70 1554.8 ---- W ater (sea) –4 1430.2[...]
-
Página 72
66 Micro Motion 7827 Digital Viscosi ty Meter Product Data[...]
-
Página 73
Installation and Conf iguration Manual 67 Safety Certification Return Policy Product Data Calculated Parameters Appendix D Return Policy D.1 General guidelines Micro Motion pro cedures must be followed when returning equipment. These proced ures ensure legal compliance with gov ernment transportation agencies and help pro vide a safe working en vir[...]
-
Página 74
68 Micro Motion 7827 Digital Viscosi ty Meter Return Policy[...]
-
Página 75
[...]
-
Página 76
Micro Motion USA Worldwide Headquarters 7070 Winchester Circle Boulder , CO 80301 T +1 303-527-5200 +1 303-522-6277 F +1 303-530-8459 Micro Motion Slough Emerson Process Management 158 Edinburgh Avenue Slough, Berks, UK SL1 4UE T +44 1753 756600 F +44 1753 823589 Micro Motion Asia Emerson Process Management 1 Pandan Crescent Singapore 128461 Republ[...]