Hearth and Home Technologies 5100I-NL-B manual
- Ver online ou baixar oubaixar o manual
- 44 páginas
- 3.35 mb
Ir para a página of
Manuais similares
-
Indoor Fireplace
Hearth and Home Technologies NDV3933I
84 páginas 8.92 mb -
Indoor Fireplace
Hearth and Home Technologies SILH60E-B
28 páginas 1.87 mb -
Indoor Fireplace
Hearth and Home Technologies A42C
48 páginas 4.27 mb -
Indoor Fireplace
Hearth and Home Technologies HUDBAY-FS
49 páginas 3.31 mb -
Indoor Fireplace
Hearth and Home Technologies CL36D
32 páginas 1.62 mb -
Indoor Fireplace
Hearth and Home Technologies A36R/C
2 páginas 0.4 mb -
Indoor Fireplace
Hearth and Home Technologies A42R
48 páginas 4.25 mb -
Indoor Fireplace
Hearth and Home Technologies IDV6247ILH
64 páginas 8.12 mb
Bom manual de uso
As regras impõem ao revendedor a obrigação de fornecer ao comprador o manual com o produto Hearth and Home Technologies 5100I-NL-B. A falta de manual ou informações incorretas fornecidas ao consumidor são a base de uma queixa por não conformidade do produto com o contrato. De acordo com a lei, pode anexar o manual em uma outra forma de que em papel, o que é frequentemente utilizado, anexando uma forma gráfica ou manual electrónicoHearth and Home Technologies 5100I-NL-B vídeos instrutivos para os usuários. A condição é uma forma legível e compreensível.
O que é a instrução?
A palavra vem do latim "Instructio" ou instruir. Portanto, no manual Hearth and Home Technologies 5100I-NL-B você pode encontrar uma descrição das fases do processo. O objetivo do manual é instruir, facilitar o arranque, a utilização do equipamento ou a execução de determinadas tarefas. O manual é uma coleção de informações sobre o objeto / serviço, um guia.
Infelizmente, pequenos usuários tomam o tempo para ler o manual Hearth and Home Technologies 5100I-NL-B, e um bom manual não só permite conhecer uma série de funcionalidades adicionais do dispositivo, mas evita a formação da maioria das falhas.
Então, o que deve conter o manual perfeito?
Primeiro, o manual Hearth and Home Technologies 5100I-NL-B deve conte:
- dados técnicos do dispositivo Hearth and Home Technologies 5100I-NL-B
- nome do fabricante e ano de fabricação do dispositivo Hearth and Home Technologies 5100I-NL-B
- instruções de utilização, regulação e manutenção do dispositivo Hearth and Home Technologies 5100I-NL-B
- sinais de segurança e certificados que comprovam a conformidade com as normas pertinentes
Por que você não ler manuais?
Normalmente, isso é devido à falta de tempo e à certeza quanto à funcionalidade específica do dispositivo adquirido. Infelizmente, a mesma ligação e o arranque Hearth and Home Technologies 5100I-NL-B não são suficientes. O manual contém uma série de orientações sobre funcionalidades específicas, a segurança, os métodos de manutenção (mesmo sobre produtos que devem ser usados), possíveis defeitos Hearth and Home Technologies 5100I-NL-B e formas de resolver problemas comuns durante o uso. No final, no manual podemos encontrar as coordenadas do serviço Hearth and Home Technologies na ausência da eficácia das soluções propostas. Atualmente, muito apreciados são manuais na forma de animações interessantes e vídeos de instrução que de uma forma melhor do que o o folheto falam ao usuário. Este tipo de manual é a chance que o usuário percorrer todo o vídeo instrutivo, sem ignorar especificações e descrições técnicas complicadas Hearth and Home Technologies 5100I-NL-B, como para a versão papel.
Por que ler manuais?
Primeiro de tudo, contem a resposta sobre a construção, as possibilidades do dispositivo Hearth and Home Technologies 5100I-NL-B, uso dos acessórios individuais e uma gama de informações para desfrutar plenamente todos os recursos e facilidades.
Após a compra bem sucedida de um equipamento / dispositivo, é bom ter um momento para se familiarizar com cada parte do manual Hearth and Home Technologies 5100I-NL-B. Atualmente, são cuidadosamente preparados e traduzidos para sejam não só compreensíveis para os usuários, mas para cumprir a sua função básica de informação
Índice do manual
-
Página 1
DO NOT DISCARD THIS MANUAL NOTICE • I m p o r t a n t o p e r a t i n g and maintenance in- structions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. DO N O T DIS C AR D WA RNI NG If the information in these i nst ruc - tio ns is[...]
-
Página 2
5100-I ACT WOOD INSERT Page September 1, 2008 R 438-0380D and Welcome to the Quadra-Fire Family ! H earth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and perfor - mance. This commitment begins with our research of the ma[...]
-
Página 3
Page 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 Section 1: Listing and Code Approvals A. Appliance Certications ...................... 4 B. Mobile Home Approved ...................... 4 C. Glass Specications ............................ 4 D. BTU & Efciency Specications .......... 4 Section 2: Getting Started A. Design,[...]
-
Página 4
5100-I ACT WOOD INSERT Page September 1, 2008 R 438-0380D 1 Listing and Code Approvals The Quadra-Fire 5100-I ACT Wood Inserts meets the U.S. Environmental Protection Agency’s 1990 particulate emis - sion standards. MODEL: 5100-I ACT W ood Insert LABORA TOR Y : OMNI T est Laboratories, Inc. REPORT NO. 061-S-59-2 TYPE: Wood Stove ST ANDARD: UL[...]
-
Página 5
Page 5 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 2 Getting Started A . Design, Installation & Location Considerations Consideration must be given to: • Safety • Convenience • T rafc ow • Chimney and chimney connector required It is a good idea to plan your insta llatio n on paper , using exact measurements for clearance[...]
-
Página 6
5100-I ACT WOOD INSERT Page 6 September 1, 2008 R 438-0380D C. Negative Pressure Draft is the pressure difference needed to vent appliances successfully . Considerations for successful draft include: • Preventing negative pressure • Location of appliance and chimney Negative pressure results from the imbalance of air avail- able for the repl[...]
-
Página 7
Page 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 D. Flue Draft Considerations Location of the appliance and chimney will affect perfor- mance. As shown in Figure 6.1 the chimney should: • Be installed through the warm space enclosed by the building envelope. This helps to produce more draft, especially during lighting and die down of[...]
-
Página 8
5100-I ACT WOOD INSERT Page 8 September 1, 2008 R 438-0380D 3 Dimensions and Clearances A. Appliance Dimensions T OP VIEW SIDE VIEW FRONT VIEW A B 39-1/8" (994mm) 26-3/4" (679mm) 9-1/8" (232mm) 22-1/4" (565mm) 21-1/8" (537mm) 29-5/8" (752mm) 10-1/2" (267mm) 34-3/16" (919mm) C L 25-5/8" (651mm) 12-7/8&quo[...]
-
Página 9
Page 9 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 In Canada a full length 6 inch (15mm) ULC S65 ue liner required as per ULC S68. NOTE: When installing into a masonry replace, the re - place must be built to UBC Chapter standards. Do not remove brick or mortar from masonry replace to accom - modate insert. The [...]
-
Página 10
5100-I ACT WOOD INSERT Page 10 September 1, 2008 R 438-0380D Thermal protection must be 1/2 inch (13mm) minimum thickness (“k” value = 0.8) or equivalent material. All oor protection must be non-combustible (i.e., metals, brick, stone, mineral ber boards, etc.). Any organic materi - als (i.e., plastics, wood paper products, etc.) are c[...]
-
Página 11
Page 1 1 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 NOTE: If your home is fairly airtight, it is recommend that you install the outside air that comes standard with the appliance. If you are installing into a Mobile Home, outside air is required. The replace must have an outside air supply coming into it in order for the insert outside[...]
-
Página 12
5100-I ACT WOOD INSERT Page 1 September 1, 2008 R 438-0380D The 5100-I Insert comes standard with 2 blowers, installed at the factory with the power cord on right side of insert (as you face the unit). Do not route the power cord under or in front of appliance. The power cord can also be installed on the left side. Follow instructions below . E.[...]
-
Página 13
Page 1 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 Figure 13.1 F . Wiring Diagram & AN#ONTROL3PEED #ONTROL2HEOSTAT 3NAP$ISC 3NAP$ISC "Y0ASS 3WITCH ,INE 'ROUND .EUTRAL & AN & AN & & G. Optional Offset Adapter FULLY EXTENDED FULLY CLOSED 3-1/4" 7-3/4&quo[...]
-
Página 14
5100-I ACT WOOD INSERT Page 1 September 1, 2008 R 438-0380D 5 Chimney Requirements A. V enting Components Chimney Connector: It is also known as ue pipe or stove pipe. It must be 6 inc hes (152m m) minim um dia mete r sta inle ss ste el conne ctor pipe. Chimney : Th e ch imn ey can be new or exi stin g, mas onr y or pr ef abr ica ted and must[...]
-
Página 15
Page 15 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 Floor Ceiling Caulk Floor (second Story) Non-Combustible Firestopping Material Minimum 1 inch (25mm) clearance from exterior chimney to sheathing Firestopping 2 inch (51mm) Non-combustible fire stopping material Minimum 2 inch (51mm) clearance from combustible material and insulation ceil[...]
-
Página 16
5100-I ACT WOOD INSERT Page 16 September 1, 2008 R 438-0380D D. Chimney T ermination Requirements Follow manufacturers instructions for clearances, securing, ashing and terminating the chimney . • Must have an approved and listed cap • Must not be located where it will become plugged by snow or other material • Must terminate at least 3 fe[...]
-
Página 17
Page 1 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 F . Masonry Fireplace UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System Follow Manufacturer ’s Instructions on Insulation and Support For Zero or Other Non-Code Clearances, Follow Approved Liner Manufacturer ’s Specific Insulation Requirements: Different Cleara[...]
-
Página 18
5100-I ACT WOOD INSERT Page 18 September 1, 2008 R 438-0380D G. Factory-Built Zero Clearance Fireplace The Quadra-Fire 5100-I Insert is listed to UL 18 Standard and is approved for installation into listed factory-built zero clearance replaces listed to UL 1 conforming to the follow - ing specications and instructions: Minimum Wid[...]
-
Página 19
Page 19 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 Spark Arestor Cap Roof Flashing Storm Collar Joist Shield/Firestop Listed StaInless Steel Liner 6 Mobile Home Installation 1. An outside air inlet must be provided for combustion See page 1 1 for detailed information. 2. Ap pli anc e mus t be sec ure d to th e mobi le hom e stru ctu re . [...]
-
Página 20
5100-I ACT WOOD INSERT Page 0 September 1, 2008 R 438-0380D Figure 20.1 Figure 20.2 Figure 20.3 T wo leveling bolts, 3/8” x 4” are shipped inside the com- ponent pack found inside the rebox. NOTE: Not all installations will require the use of the level - ing bolts. 1. Remove the bolts from the component pack and insert into weld nuts weld[...]
-
Página 21
Page 1 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 Figure 21.1 Figure 22.2 There are two options to secure the liner to the chimney ring: Option One: If there is enough room on the top of the insert to work, hand bend the tabs upward 90°. Secure the liner with the supplied hex head bolts 1/4-20-3/4. Option T wo: Remove the manifold[...]
-
Página 22
5100-I ACT WOOD INSERT Page September 1, 2008 R 438-0380D Figure 22.1 Figure 22.2 Figure 22.3 Figure 22.4 E. Zero Clearance Adjustable T rim Support Size: 12” d x 50” w , 2-10” h 1. The 10 screws on each set of scissors will already be loose when shipped. Figure 22.1. 2. Expand scissors to desired height. Tighten screws to hold in plac[...]
-
Página 23
Page 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 8 Operating Instructions A. Over-Firing Y our Appliance Do not over-re. Over-ring may ignite creosote or will damage the stove and chimney . T o prevent over-ring your stove, DO NOT : • Use ammable liquids • Overload with wood • Burn trash or large amounts of scrap l[...]
-
Página 24
5100-I ACT WOOD INSERT Page September 1, 2008 R 438-0380D P rima ry Ai r Con trol S tart-U p Air Con t ro l Figure 24.1 warmin g your home and estab lishing the ue draft, not evapo - rating the moisture out of wet, unseasoned wood, resulting in wasted heat. The air control in the right side of the grille is called the Start- Up Air Contro[...]
-
Página 25
Page 5 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 1. Starting Fire: Open (push in) both controls fully . After a wood load has been burning for 5 to 15 minutes (longer for very large pieces) close the Start-Up Air Control by pulling it out. 2. High Burn Rate: Leave the Primary Air Control fully open. It is important to do this when rel[...]
-
Página 26
5100-I ACT WOOD INSERT Page 6 September 1, 2008 R 438-0380D This appliance is equipped with a 1 10° thermally operated snap disc which will automatically turn the blower on when the insert reaches this temperature. The snap disc is located at the center of the insert, under the lower grille. There is a manual override switch on the right side o[...]
-
Página 27
Page 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 Odors and vapors are released during initial operation. • Curing of high temperature paint. • Open windows for air circulation. Odors may be irritating to sensitive individuals. CAUTION J. Frequently Asked Questions ISSUES SOLUTIONS Odor from appliance When rst operated, this a[...]
-
Página 28
5100-I ACT WOOD INSERT Page 8 September 1, 2008 R 438-0380D 9 Maintaining & Servicing Y our Appliance A. General Maintenance Inspection: Inspect the system at the appliance connection and at the chimney top. Cooler surfaces tend to build creosote deposits quicker , so it is important to check the chimney from the top as well as from the bott[...]
-
Página 29
Page 9 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 Quadra-Fire stoves are equipped with ceramic super heat- resistant glass, which can only be broken by impact or misuse. Do not slam stove door or impact the glass. When closing door , make sure that logs do not protrude against the glass. Inspect glass regularly . If you nd a crack o[...]
-
Página 30
5100-I ACT WOOD INSERT Page 0 September 1, 2008 R 438-0380D D. Door Handle Assembly Replacement 1. Install washer on door handle shaft. 2. Slide door handle through door. 3. Install second washer(s) as shown. . Install key in groove. 5. Align groove in latch cam with key; slide latch cam over shaft 6. Install locknut. . Install spring hand[...]
-
Página 31
Page 1 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 The rebox is lined with high quality rebrick, which has exceptional insulating properties. There is no need to use a grate; simply build a re on the rebox oor . Do not operate appliance without rebrick. E. Firebrick Replacement • Frequency: As needed • By: Homeowne[...]
-
Página 32
5100-I ACT WOOD INSERT Page September 1, 2008 R 438-0380D 1. Remove the panel and trim set. See pages 20-21 for complete details. 2. Remove 2 screws on blower housing. . Unhook the wires from the blower . 4. Slide blower housing out. 5. Remove 2 screws from blower and remove from housing. 6. Attach new blower to housing. 7. Re-assemble in[...]
-
Página 33
Page 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 CORRECT POSITION INCORRECT POSITIONS Firebox damage due to improper bafe place - ment is not covered by warranty . Operate the wood burning appliance with the bafe in the correct position only . Not doing so could result in: • Reduced efciency • Overheating the chimney ?[...]
-
Página 34
5100-I ACT WOOD INSERT Page September 1, 2008 R 438-0380D 10 T roubleshooting With proper installation, operation, and maintenance your appliance provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualied service person in the diagnosis of a problem and the corrective action to [...]
-
Página 35
Page 5 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 3. I smell smoke in the house during operation. What is causing it? Diagnostic Question Possible Causes of Condition Solutions Do res start and burn well? No: • Chimney obstruction • Not enough kindling and/or fuel to establish draft • Inadequate combustion air • Air controls[...]
-
Página 36
5100-I ACT WOOD INSERT Page 6 September 1, 2008 R 438-0380D 1 1 Reference Materials A. Exploded Views Beginning Manufactured Date: November 1, 2004 Figure 36.1 - Front Door & Glass Assembly Figure 36.3 - Wood Insert Figure 36.2 -Side Window 7 5 6 4 1 10 9 8 3 2 Groove for glass placement 13 1 1 12 29 14 15 16 18 19 20 28 26 22 21 17 30 27[...]
-
Página 37
Page 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 IMPORT ANT : THIS IS DA TED INFORMA TION . The most current information is located on the Quadra-Fire web site at www .quadrare.com. When ordering, supply serial and model numbers to ensure correct part. B. Service Parts & Accessories Item # Part Description Alphabetical Order [...]
-
Página 38
5100-I ACT WOOD INSERT Page 8 September 1, 2008 R 438-0380D Item # Part Description Alphabetical Order SKU Part Description Alphabetical Order Serial Number SKU Grille Assembly , Gold 832-3100 Grille Assembly , Nickel 832-3100NL Panel, Standard, Gold, 0-1/” h x ” w 831-1452 Panel Standard, Nickel, 0-1/” h x ” w SP[...]
-
Página 39
Page 9 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 Date of Service Performed By Description of Service C. Service And Maintenance Log[...]
-
Página 40
5100-I ACT WOOD INSERT Page 0 September 1, 2008 R 438-0380D Date of Service Performed By Description of Service C. Service And Maintenance Log (Cont’d)[...]
-
Página 41
Page 1 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 D. Homeowner ’ s Notes[...]
-
Página 42
5100-I ACT WOOD INSERT Page September 1, 2008 R 438-0380D E. W arranty Policy Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in the Uni[...]
-
Página 43
Page 5100-I ACT WOOD INSERT R 438-0380D September 1, 2008 Hearth & Home T echnologies LIMITED W ARRANTY (Cont’d) HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main- tenance of the appliance not in accordance with the installation instructions; operating instructi[...]
-
Página 44
Page September 1, 2008 438-0380D R • Do NOT discard this manual. • Important operating and maintenance instructions included. • Read, understand and follow these instruci- tons for safe installation and operation. • Leave this manual with party responsible for use and operation. CAUTION Hearth & Home T echnologies 1445 North High[...]