Hearth and Home Technologies 839-1460 manual
- Ver online ou baixar oubaixar o manual
- 56 páginas
- 3.83 mb
Ir para a página of
Manuais similares
-
Indoor Fireplace
Hearth and Home Technologies CERONA-36
4 páginas 0.94 mb -
Indoor Fireplace
Hearth and Home Technologies CB4842IR
40 páginas 2.89 mb -
Indoor Fireplace
Hearth and Home Technologies IDV6247IT
64 páginas 8.12 mb -
Indoor Fireplace
Hearth and Home Technologies 839-1320
56 páginas 2.94 mb -
Indoor Fireplace
Hearth and Home Technologies WHB42
4 páginas 0.89 mb -
Indoor Fireplace
Hearth and Home Technologies SL-550TV-IPI-D
53 páginas 3.49 mb -
Indoor Fireplace
Hearth and Home Technologies ST36D
48 páginas 4.01 mb -
Indoor Fireplace
Hearth and Home Technologies BIR42-B
55 páginas 7.29 mb
Bom manual de uso
As regras impõem ao revendedor a obrigação de fornecer ao comprador o manual com o produto Hearth and Home Technologies 839-1460. A falta de manual ou informações incorretas fornecidas ao consumidor são a base de uma queixa por não conformidade do produto com o contrato. De acordo com a lei, pode anexar o manual em uma outra forma de que em papel, o que é frequentemente utilizado, anexando uma forma gráfica ou manual electrónicoHearth and Home Technologies 839-1460 vídeos instrutivos para os usuários. A condição é uma forma legível e compreensível.
O que é a instrução?
A palavra vem do latim "Instructio" ou instruir. Portanto, no manual Hearth and Home Technologies 839-1460 você pode encontrar uma descrição das fases do processo. O objetivo do manual é instruir, facilitar o arranque, a utilização do equipamento ou a execução de determinadas tarefas. O manual é uma coleção de informações sobre o objeto / serviço, um guia.
Infelizmente, pequenos usuários tomam o tempo para ler o manual Hearth and Home Technologies 839-1460, e um bom manual não só permite conhecer uma série de funcionalidades adicionais do dispositivo, mas evita a formação da maioria das falhas.
Então, o que deve conter o manual perfeito?
Primeiro, o manual Hearth and Home Technologies 839-1460 deve conte:
- dados técnicos do dispositivo Hearth and Home Technologies 839-1460
- nome do fabricante e ano de fabricação do dispositivo Hearth and Home Technologies 839-1460
- instruções de utilização, regulação e manutenção do dispositivo Hearth and Home Technologies 839-1460
- sinais de segurança e certificados que comprovam a conformidade com as normas pertinentes
Por que você não ler manuais?
Normalmente, isso é devido à falta de tempo e à certeza quanto à funcionalidade específica do dispositivo adquirido. Infelizmente, a mesma ligação e o arranque Hearth and Home Technologies 839-1460 não são suficientes. O manual contém uma série de orientações sobre funcionalidades específicas, a segurança, os métodos de manutenção (mesmo sobre produtos que devem ser usados), possíveis defeitos Hearth and Home Technologies 839-1460 e formas de resolver problemas comuns durante o uso. No final, no manual podemos encontrar as coordenadas do serviço Hearth and Home Technologies na ausência da eficácia das soluções propostas. Atualmente, muito apreciados são manuais na forma de animações interessantes e vídeos de instrução que de uma forma melhor do que o o folheto falam ao usuário. Este tipo de manual é a chance que o usuário percorrer todo o vídeo instrutivo, sem ignorar especificações e descrições técnicas complicadas Hearth and Home Technologies 839-1460, como para a versão papel.
Por que ler manuais?
Primeiro de tudo, contem a resposta sobre a construção, as possibilidades do dispositivo Hearth and Home Technologies 839-1460, uso dos acessórios individuais e uma gama de informações para desfrutar plenamente todos os recursos e facilidades.
Após a compra bem sucedida de um equipamento / dispositivo, é bom ter um momento para se familiarizar com cada parte do manual Hearth and Home Technologies 839-1460. Atualmente, são cuidadosamente preparados e traduzidos para sejam não só compreensíveis para os usuários, mas para cumprir a sua função básica de informação
Índice do manual
-
Página 1
Quartet Front Solitaire Front www .quadrafire.com September 1, 2008 250-7233H R O-T L T ested and Listed by Portland Oregon USA OMNI-T est Laboratories, Inc. C US DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand[...]
-
Página 2
Page 2 Quadra-Fire · Sapphire · 250-7233H September 1, 2008 and Welcome to the Quadra-Fire Family ! Hearth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance. This commitment begins with our research of the market[...]
-
Página 3
Page 3 Quadra-Fire · Sapphire · 250-7233H - T ABLE OF CONTENTS - September 1, 2008 Section 1: Listing and Code Approvals A. Appliance Certifications ...................... 4 B. Glass Specifications ............................ 4 C. BTU Specifications .............................. 4 D. High Altitude Installations .................... 4 E. Non-[...]
-
Página 4
Page 4 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H 1 Listing and Code Approvals The product is listed to ANSI standards for “V ented Gas Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recre- ational V ehicles” and "Gas Fired Appliances for use at High Altitudes".[...]
-
Página 5
September 1, 2008 Page 5 Quadra-Fire · Sapphire · 250-7233H NOTE: The following requirements reference various Massachusetts and national codes not contained in this document. For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including t[...]
-
Página 6
Page 6 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H 2 Getting Started Check building codes prior to installation. • Installation MUST comply with local, regional, state and national codes and regulations. • Consult local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and perm[...]
-
Página 7
September 1, 2008 Page 7 Quadra-Fire · Sapphire · 250-7233H 3 Appliance Location and Clearances A. Selecting Appliance Location NOTE: · Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONL Y . · Illustrations/diagrams are not drawn to scale. · Actual installation may vary due to individual design preference. When select[...]
-
Página 8
Page 8 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H 4 T ermination Locations A. V ent T ermination Minimum Clearances 20 in. (508mm) (minimum) to Perpendicular W all (Gas Only) A 18 in. (457mm) Gas or Wood T ermination Gas T ermination Gas T ermination A 6 in. (152mm) W ood & Fuel Oil T ermination 20 in. (508mm) Figure 4.2 Multiple V [...]
-
Página 9
September 1, 2008 Page 9 Quadra-Fire · Sapphire · 250-7233H Figure 4.4 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED A = 12 inches ............. clearances above grade, veran- da, porch, deck or balcony B = 1 2 i n c hes ............ clearances to window or door that may be opened, or to per- manently closed windo[...]
-
Página 10
Page 10 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H 5 V ent Information A. V enting Components B. Use of Elbows In order to comply with applicable codes and product warranties, use only following venting components: • Hearth & Home T echnologies (HHT) • Simpson Dura-V ent (SDV) • Selkirk • AmeriV ent • Security Secure V ent[...]
-
Página 11
September 1, 2008 Page 1 1 Quadra-Fire · Sapphire · 250-7233H D. How to Use the V ent Graph E. V enting Guidelines NOTE: IF YOUR INST ALLA TION F ALLS WITHIN A SHADED AREA ON THE GRAPH, THE DAMPER MUST BE USED. NOTE: In the Commonwealth of Massachusetts, the word damper shall be replaced with the words flue restrictor . 1. Measure the distance fr[...]
-
Página 12
Page 12 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H Female Locking Lugs Male Locking Lugs Step 1. Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance. F . Horizonta[...]
-
Página 13
September 1, 2008 Page 13 Quadra-Fire · Sapphire · 250-7233H NOTE: (1) Installation requires a minimum of 1 1 in. (279mm) horizontal run. Each 1 ft. (305mm) of horizontal vent run must include a 1/4 in. (6mm) of vertical rise towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the poss[...]
-
Página 14
Page 14 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H Step 5. Place the wall thimble cover over the pipe assembly and slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the vent termination cap assembly . It is important that the vent pipe extend into the vent termination cap a sufficient distanc[...]
-
Página 15
September 1, 2008 Page 15 Quadra-Fire · Sapphire · 250-7233H Step 1. Check the installation instructions for required 1 in. (25mm) clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. See page 16, Figure 5.15. Check the instructions for maximum vertica[...]
-
Página 16
Page 16 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H Step 4. Assemble the desired lengths of pipe and elbows necessary to reach from the appliance up through the round support box. Ensure that all pipe and elbow connections are in their fully twist-locked position. Assemble as instructed. Step 5. Cut a hole in the roof centered on the sma[...]
-
Página 17
September 1, 2008 Page 17 Quadra-Fire · Sapphire · 250-7233H Ceiling Firestop Nails Minimum 1 in. (24mm) Clearance Minimum 1 in. (24mm) Clearance Minimum 1 in. (24mm) Clearance Minimum 1 in. (24mm) Clearance Figure 5.16 Fire Risk. Explosion Risk. W ARNING • Any occupied areas above the first floor , including closets and storage spaces, which t[...]
-
Página 18
Page 18 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H 2. Cathedral Ceiling Level Cathedral Ceiling Support Box 2 in. (51mm) Min. below finished ceiling Cut hole 1/8 in. (3mm) greater in size than pattern of support box as it is projected onto roof line Figure 5.16 Figure 5.17 Step 1. Follow installation Steps 1 and 2 under vertical install[...]
-
Página 19
September 1, 2008 Page 19 Quadra-Fire · Sapphire · 250-7233H High Wind T ermination Cap Sheet Metal Screws Drill Four 1/8 in. (3mm) Diamater Holes Figure 5.21 Figure 5.22 Step 4. Pass the flex pipe down through the center of the chimney system, and center the top adapter on the top of the chimney pipe. Drill four 1/8 in. (3mm) diameter holes thro[...]
-
Página 20
Page 20 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H 4. Existing Masonry Chimney T ype A - Up & Out Installations for T op V ent Configurations Figure 5.23 T ype B - Hearth Rear V ent Installations for Use With Rear V ent Kit (see Section 12 for conversion kit and venting components.) T ermination Cap Flashing 4 in. (102mm) Flex Liner[...]
-
Página 21
September 1, 2008 Page 21 Quadra-Fire · Sapphire · 250-7233H 10 in. x 10 in. (254mm x 254mm) framed opening in wall Studwall Masonry Chimney Retro Connector (4) Masonry Bolts (Not Included) Wall Thimble Cover Cut and bend flashing as needed to fit Sealant adhesive Figure 5.24 Figure 5.25 Step 1. Before cutting any holes, assemble the desired sect[...]
-
Página 22
Page 22 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H High Wind T ermination Cap T op Adaptor (3) Sheet Metal Screws Flashing Step 9. Attach the flex to the retro connector. Use three sheet metal screws to attach the flex liner to the connector ( Figure 5.28 ). Mount the retro connector to the masonry wall using masonry bolts. Redrill larg[...]
-
Página 23
September 1, 2008 Page 23 Quadra-Fire · Sapphire · 250-7233H 6 Gas Information A. Fuel Conversions Before making gas connections ensure that the appliance being installed is compatible with the available gas type. Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a quali- fied technician us[...]
-
Página 24
Page 24 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H A B C Mounting Screws Pressure Regulator T ower Diaphragm Figure 6.6 T urn control knob to the OFF position, ensure that gas supply to the valve has been turned off. Using a T orx TH20, or slotted screwdriver , remove the three pressure reg- ulator mounting screws (A) , pressure regulat[...]
-
Página 25
September 1, 2008 Page 25 Quadra-Fire · Sapphire · 250-7233H Fire Risk. Explosion Risk. • If the information in these instructions is not followed exactly , a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. • The qualified service agency is responsible for the proper inst[...]
-
Página 26
Page 26 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H • A small amount of air will be in the gas supply lines. When first lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally . Air only needs to be purged again if gas valve has been turned to the[...]
-
Página 27
September 1, 2008 Page 27 Quadra-Fire · Sapphire · 250-7233H 7 Electrical Information A. Recommendation for Wire C. Standing Pilot Ignition System Wiring See B5 below for recommended maximum lead length (two wire) when using wall thermostat/switch. B. Connecting to the Appliance This appliance DOES NOT require 1 10 V AC supply for operation. A wi[...]
-
Página 28
Page 28 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H Figure 7.1 CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. Shock hazard. • Replace damaged wire with type 105 O C rated wire. • Wire must have high temperature[...]
-
Página 29
September 1, 2008 Page 29 Quadra-Fire · Sapphire · 250-7233H 8 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the firebox. B. T op and Rear V ent Conversion Figure 8.1 Remove rear access plate on the back shield and discard. Figure 8.2 Remove the rear outer flue cover plate (with the damper adju[...]
-
Página 30
Page 30 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H Figure 8.4 Install the inner flue collar on rear of appliance , with damper rod pointing up. A dab of high temperature silicone on the gasket will help gasket adhere to the appliance. Figure 8.5 Install the inner flue cover on top of the appliance, ensuring that the damper rod is in t[...]
-
Página 31
September 1, 2008 Page 31 Quadra-Fire · Sapphire · 250-7233H Figure 8.9 Remove burner by sliding the shutter to the right, lifting up the left side of the burner and sliding it the the left. Figure 8.10 Remove the main burner orifice using a 5/8 in. wrench. PROP ANE NA TURAL GAS .059 (53 DMS) .096 (41(DMS) NOTE: If the venting configuration has [...]
-
Página 32
Page 32 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H E. Front Installation Figure 8.13 T o remove the face, loosen the thumb bolt beneath the ashlip. Figure 8.14 Lift up on the top of the Front, gently pulling out on the bottom. Set aside in a safe location. For BOTH Quartet and Solitaire Fronts: INST ALLA TION AND REMOV AL INSTRUCTIONS F[...]
-
Página 33
September 1, 2008 Page 33 Quadra-Fire · Sapphire · 250-7233H F . Hearth Legs Installation Refer to Section 12 for specific color part numbers. Hearth legs will allow three additional inches of clearance. Be sure to calculate this distance correctly if necessary to cut wall hole to install horizontally . Refer to Dimensions on in Section 12. T o c[...]
-
Página 34
Page 34 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H H. Mineral Wool • Follow ember placement instructions in manual. • Do NOT place embers directly over burner ports. • Replace ember material annually . Explosion Risk. W ARNING Improperly placed embers interferes with proper burner operation. Figure 8.21 Place individual pieces of [...]
-
Página 35
September 1, 2008 Page 35 Quadra-Fire · Sapphire · 250-7233H NOTE: This blower utilizes a snap disc to control ON and OFF operation. When the correct temperature is reached, the blower will automatically turn ON. Use the rheostat knob to adjust the fan to High or Low to suit your preferences. Figure 8.24 Use two screws to connect the snap disc br[...]
-
Página 36
Page 36 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H SNAP DISC 6 in. (152mm) BLACK BLOWER 4 in. (102mm) WHITE CORD M F M F 34 in. (864mm) BLACK 34 in. (864mm) WHITE F M M F RHEOST A T F F M F Figure 8.26 Blower Wiring Diagram[...]
-
Página 37
September 1, 2008 Page 37 Quadra-Fire · Sapphire · 250-7233H See vent graph for recommendations on page 1 1 before you begin your adjustment. If your installation falls within the range of the gray shaded area of graph, it may be necessary to make an adjustment to the vertical damper to improve the flame appearance in your appliance. NOTE: In the[...]
-
Página 38
Page 38 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H 9 Operating Instructions A. Before Lighting Appliance Read this entire manual prior to using the appliance. Failure to follow the instructions may result in property damage, bodily injury, or even death. Glass door must be in place when appliance is operating. Risk of: • Combustion Fu[...]
-
Página 39
September 1, 2008 Page 39 Quadra-Fire · Sapphire · 250-7233H C. Lighting Appliance 1. Set the thermostat to lowest setting. 2. T urn off all electric power to the appliance if service is to be performed. 3. Push in gas control knob slightly and turn clockwise to "OFF" position. FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS [...]
-
Página 40
Page 40 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H D. After Appliance is Lit When you light your appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours [...]
-
Página 41
September 1, 2008 Page 41 Quadra-Fire · Sapphire · 250-7233H 10 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the corrective act[...]
-
Página 42
Page 42 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H Symptom Possible Cause Corrective Action 3. (Continued) c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter at the thermopile terminals. The millivolt meter should read greater than 125mV . If the reading is [...]
-
Página 43
September 1, 2008 Page 43 Quadra-Fire · Sapphire · 250-7233H 11 Maintaining and Servicing Appliance Although the frequency of your appliance servicing and maintenance will depend on use and the type of installation, a qualified service technician should perform an appliance check-up at the beginning of each heating season. Risk of injury or prop[...]
-
Página 44
Page 44 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H Inspect Maintenance T asks Doors 1. Inspect for scratches, dents or other damage and repair as necessary . 2. V erify no obstructions to air flow . 3. V erify maintenance of proper clearance to combustible household objects. Gasket Seal, Glass Assembly and Glass 1. Inspect gasket seal [...]
-
Página 45
September 1, 2008 Page 45 Quadra-Fire · Sapphire · 250-7233H 12 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For clearances refer to Section 3. Figure 12.1 Appliance Dimensions NOTE: If appliance is equipped with Hearth Legs Kit, center-line dimension is reduced by 3 in. ([...]
-
Página 46
Page 46 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H B. V ent Components Diagram Figure 12.2 SL-D Series V ent Components 4 in. (102 mm) inner pipe 6-5/8 in. (168 mm) outer pipe 9-1/4 in. (235mm) 6-1/2 in. (165mm) 6-5/8 in. (168mm) 17-24 in. (432-610mm) 1 1-3/4 in. (298mm) 5-3/4 in. (146mm) 6-5/8 in. (168mm) 6-3/8 in. (162mm) 6-1/2 in. (1[...]
-
Página 47
September 1, 2008 Page 47 Quadra-Fire · Sapphire · 250-7233H C. V ent Components List Description HHT SL-P M= Multi Pack (6) Simpson Dura-V ent DirectV ent Pro Selkirk Direct-T emp Amerivent Direct Security Secure V ent 4” Pipe Length, Galvanized SLP4M - - - - 4” Pipe Length, Black SLP4-BK - - - - 6” Pipe Length, Galvanized SLP6M 46-DV A-06[...]
-
Página 48
Page 48 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H 45° Elbow , Swivel, Black - 46DV A-E45B - - SV4EB45 90° Elbow , Galvanized SLP90M See Swivel 4DT -EL905 4D90LS - 90° Elbow , Black SLP90-BK See Swivel 4DT -EL90SB 4D90LBS SV4EBR90 90° Elbow , Swivel, Galvanized - 46DV A-E90 - - SV4E90 90° Elbow , Swivel, Black - 46DV A-E90B - - SV4[...]
-
Página 49
September 1, 2008 Page 49 Quadra-Fire · Sapphire · 250-7233H D. Service Parts List R SAPPHIRE (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 4-24-02 Ending Manufacturing Date: Item # Description Item # Description 1 Refractory , Metal 12 Igniter , Piezo 2 Log Support, Rear 13 Switch, Rocker , ON/OFF 3 Burner Support 14 Knob, Rheost[...]
-
Página 50
Page 50 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H Item # Part Description Alphabetical Order SKU Adapter , DV 7000-162 18 Adapter , V alve Extension 450-6330 Air Shutter Assembly 468-5060 Ash Lip 454-0070 20 Back Shield 455-0200 19 Back Shield Cover Plate 455-0220 22 Baffle 455-0290 21 Baffle Hanger 455-0300 Blower BK-GAS 4 Bulkhead [...]
-
Página 51
September 1, 2008 Page 51 Quadra-Fire · Sapphire · 250-7233H Item # Part Description Alphabetical Order SKU IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts. D. Service Parts (cont’d.) R (NG, LP) Explod[...]
-
Página 52
Page 52 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts. D. Service Parts (cont’d.) R SAPPHIRE (NG, LP) Exploded Parts Diagram Beginning Manufacturi[...]
-
Página 53
September 1, 2008 Page 53 Quadra-Fire · Sapphire · 250-7233H F . Service and Maintenance Log Date of Service Performed By Description of Service[...]
-
Página 54
Page 54 September 1, 2008 Quadra-Fire · Sapphire · 250-7233H G. W arranty Policy Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in the Unite[...]
-
Página 55
September 1, 2008 Page 55 Quadra-Fire · Sapphire · 250-7233H HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main- tenance of the appliance not in accordance with the installation instructions; operating instructions and the listing agent identification label furnished with the[...]
-
Página 56
Page 56 Quadra-Fire · Sapphire · 250-7233H September 1, 2008 Hearth & Home T echnologies 1445 North Highway Colville, W A 991 14 Division of HHT INDUSTRIES CONT ACT INFORMA TION : DEALERSHIP WHERE PURCHASED: ______________________________________ _______________________________________ _______________________________________ DEALER TELEPHONE:[...]