Ir para a página of
Manuais similares
-
Furnace
Louisville Tin and Stove CF354C-H
27 páginas 0.47 mb -
Furnace
Louisville Tin and Stove 90N30A
19 páginas 0.26 mb -
Furnace
Louisville Tin and Stove CF504C-H
27 páginas 0.47 mb -
Furnace
Louisville Tin and Stove DVCF654B-R
22 páginas 0.28 mb -
Furnace
Louisville Tin and Stove DVCF403B-R
22 páginas 0.28 mb -
Furnace
Louisville Tin and Stove 78111
27 páginas 0.46 mb -
Furnace
Louisville Tin and Stove DVCF557B-R
22 páginas 0.28 mb -
Furnace
Louisville Tin and Stove HEDV254A
2 páginas 0.18 mb
Bom manual de uso
As regras impõem ao revendedor a obrigação de fornecer ao comprador o manual com o produto Louisville Tin and Stove 90N65A. A falta de manual ou informações incorretas fornecidas ao consumidor são a base de uma queixa por não conformidade do produto com o contrato. De acordo com a lei, pode anexar o manual em uma outra forma de que em papel, o que é frequentemente utilizado, anexando uma forma gráfica ou manual electrónicoLouisville Tin and Stove 90N65A vídeos instrutivos para os usuários. A condição é uma forma legível e compreensível.
O que é a instrução?
A palavra vem do latim "Instructio" ou instruir. Portanto, no manual Louisville Tin and Stove 90N65A você pode encontrar uma descrição das fases do processo. O objetivo do manual é instruir, facilitar o arranque, a utilização do equipamento ou a execução de determinadas tarefas. O manual é uma coleção de informações sobre o objeto / serviço, um guia.
Infelizmente, pequenos usuários tomam o tempo para ler o manual Louisville Tin and Stove 90N65A, e um bom manual não só permite conhecer uma série de funcionalidades adicionais do dispositivo, mas evita a formação da maioria das falhas.
Então, o que deve conter o manual perfeito?
Primeiro, o manual Louisville Tin and Stove 90N65A deve conte:
- dados técnicos do dispositivo Louisville Tin and Stove 90N65A
- nome do fabricante e ano de fabricação do dispositivo Louisville Tin and Stove 90N65A
- instruções de utilização, regulação e manutenção do dispositivo Louisville Tin and Stove 90N65A
- sinais de segurança e certificados que comprovam a conformidade com as normas pertinentes
Por que você não ler manuais?
Normalmente, isso é devido à falta de tempo e à certeza quanto à funcionalidade específica do dispositivo adquirido. Infelizmente, a mesma ligação e o arranque Louisville Tin and Stove 90N65A não são suficientes. O manual contém uma série de orientações sobre funcionalidades específicas, a segurança, os métodos de manutenção (mesmo sobre produtos que devem ser usados), possíveis defeitos Louisville Tin and Stove 90N65A e formas de resolver problemas comuns durante o uso. No final, no manual podemos encontrar as coordenadas do serviço Louisville Tin and Stove na ausência da eficácia das soluções propostas. Atualmente, muito apreciados são manuais na forma de animações interessantes e vídeos de instrução que de uma forma melhor do que o o folheto falam ao usuário. Este tipo de manual é a chance que o usuário percorrer todo o vídeo instrutivo, sem ignorar especificações e descrições técnicas complicadas Louisville Tin and Stove 90N65A, como para a versão papel.
Por que ler manuais?
Primeiro de tudo, contem a resposta sobre a construção, as possibilidades do dispositivo Louisville Tin and Stove 90N65A, uso dos acessórios individuais e uma gama de informações para desfrutar plenamente todos os recursos e facilidades.
Após a compra bem sucedida de um equipamento / dispositivo, é bom ter um momento para se familiarizar com cada parte do manual Louisville Tin and Stove 90N65A. Atualmente, são cuidadosamente preparados e traduzidos para sejam não só compreensíveis para os usuários, mas para cumprir a sua função básica de informação
Índice do manual
-
Página 1
Gas-Fir ed V ented FLOOR FURNACE INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 74521 REV . 08/97 MODEL NUMBERS MILLIVOL T CONTROL SYSTEM NA TURAL GAS 90N30A 90N50A 90N65A 90N75A W ARNING: If the information in this manual is not followed exactly , a fir e or explosion may result causing pr operty damage, personal injury or loss of life. - Do not s[...]
-
Página 2
Hourly BTU Input 30,000 50,000 62,000 75,000 W idth and Length 14”x32” 22”x32” 24”x38” 26”x42” Overall Height 29-1/4” 29-1/4” 29-7/8” 30-7/8” Overall Grille Size 16”x34- c ” 24”x34” 26”x40” 28”x44” Size of Floor Opening 14 3 ”x32 3 ”2 2 2 ”x32 2 ”2 4 2 ”x38 2 ”2 6 2 ”x42 2 ” Gas Pipe Size at F[...]
-
Página 3
HELPFUL INST ALLA TION INFORMA TION Do not attempt to heat through more than one doorway in any direction to adjoining rooms. Always over-estimate the amount of heat required rather than under-estimate it. Always use the next size floor furnace above your actual heating requirements. Seal all cracks around windows, doors, and attic access doors or [...]
-
Página 4
FRESH AIR FOR COMBUSTION AND VENTING Adequate air for combustion and venting must be provided. Any reduction in the necessary amount of fresh air can result in an oxygen starved flame that emits Carbon Monoxide (C.O.) an odorless, colorless gas that can cause serious injur y or death. A ventilated crawl space will usually provide enough fresh air .[...]
-
Página 5
CUTTING THE FLOOR OPENING Consult the specification chart on Page 2 for the correct floor opening size for the floor furnace to be installed. Lay out th e opening size on the floor by using masking tape or cutting a piece of cardboard to the opening size. The opening must be cut square. If you have determined that there is nothing under the floor t[...]
-
Página 6
INST ALLING THE DRAFT HOOD The draft hood must be installed in the same atmospheric pressure zone as the combustion air inlet. The draft hood is packed in its own carton within the master pack. Make sure the draft hood received is the correct one for the floor furnace being installed. Included in the carton are two rope-like gaskets and 7 sheet met[...]
-
Página 7
1/4” SAFE UNSAFE RECOMMENDED FIGURE 7A FIGURE 7B FIGURE 7C CONNECTING THE VENT - Continued If the floor furnace is vented into a masonry chimney , the chimney must be inspected to determine that it is clear and free of obstructions and that it is safe for the intended use. The inside of the chimney must be at least 6 inches in diameter or 6 inche[...]
-
Página 8
If more than one gas appliance is vented through a common vent system, the vent should be increased in size to accommodate the increased load. Consult your local code or the tables in the latest edition of NFP A54/ANSI.Z223.1 for the correct size. If no local codes apply , use the following alternate method for sizing a vent connected to more than [...]
-
Página 9
Refer to Figure 11 for the basic fittings you will need at the furnace. 1 . Use black iron or steel pipe and fittings or other pipe and fittings that are approved by local codes. 2 . Use pipe joint compound that is resistant to the action of Liquefied Petroleum (L.P .) Gas or to any other chemical constituents of the gases to be conducted through t[...]
-
Página 10
When you have determined that there are no leaks in the gas piping system you may purge the system of air . Disconnect the pilot supply tubing from the right side of the valve. See Figure 12. Turn the knob on the gas valve to the pilot position. Press the knob down and hold until you smell gas at the pilot supply opening. Release the knob and turn [...]
-
Página 11
FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instruc- tions exactly . B . BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHA T TO DO IF YOU SM[...]
-
Página 12
VENT SYSTEM After the floor furnace has been burning for five minutes, hold a match or candle under the draft hood at the air intake area. If the vent system is working properly , the flame will be pulled into the air inlet of the draft hood. If the vent system is not working properly , turn the floor furnace of f immediately and refer to the insta[...]
-
Página 13
ADJUSTING THE BURNER – Continued If difficulty in adjusting the burner is experienced, it may be the result of incorrect gas supply pressure or manifold pressure. Pressure can only be checked and adjusted by a trained service technician using instruments designed for that purpose. W ARNING: Do not attempt to change pressur e settings without prop[...]
-
Página 14
MAINTENANCE INSTRUCTIONS CAUTION: Label all wires prior to disconnection when servicing controls. W iring errors can cause improper and dangerous operation. For proper operation, Floor Furnace must be kept clean. At regular intervals turn control valve to off, let cool, remove register and clean dust and foreign material from jacket with vacuum cle[...]
-
Página 15
TROUBLE SHOOTING CHAR T - AUTOMA TIC PILOT & V AL VE TROUBLE SHOOTING CHAR T - MAIN BURNER SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Flame too large 1. Defective operator section of gas valve. 1. Replace complete valve. 2. Burner orifice too large. 2. Check with local gas company for proper orifice size and replace. 3. If installed above 2,000 [...]
-
Página 16
MODELS INCLUDED: 90N30A NA T . 90N50A NA T . 90N65A NA T . 90N75A NA T . GAS FLOOR FURNACE LIST PRICES Prices and specifications subject to change witout notice. All prices are F .O.B. factory . Specify model number when ordering parts. BURNER ASSEMBL Y FOR: 90N30A 90N50A 90N65A BURNER ASSEMBL Y FOR: 90N75A MARCH 2005 Page 16 10 1 2 3 4 14 13 11 12[...]
-
Página 17
MODEL NUMBER NA T . 90N30A 90N50A 90N65A 90N75A R E F . P ART LIST P ART LIST P A R T LIST P A RT LIST P AR T DESCRIPTION N O . N O . PRICE N O . PRICE N O . PRICE N O . PRICE Heat Exchanger w/Gasket 1 23074 $206.20 2 40 9 9 $291.10 24499 $331.90 24 6 9 9 $370.40 Gasket, Heat Exchanger N/A 74530 $4.20 7 4 53 0 $4.20 74532 $5.90 7 4 5 3 5 $7.20 Line[...]
-
Página 18
IMPOR T ANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEA TING EQUIPMENT WHA T YOU DON’T KNOW CAN HUR T YOU. Y our pilot light system has been designed for safe and reliable operation. Although safety mechanisms are built-in, the potential for hazard exists. This information is intended to help you avoid these hazards. YOUR G[...]
-
Página 19
LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY The Louisville Tin & Stove Co. warrants to the original user the accompanying product for the period specified herein, provided said product is installed, operated, maintained, serviced, and used according to the instructions and specifications accompanying the[...]