Louisville Tin and Stove DVCF653B-R manual
- Ver online ou baixar oubaixar o manual
- 22 páginas
- 0.28 mb
Ir para a página of
Manuais similares
-
Furnace
Louisville Tin and Stove W501F W252F
20 páginas 0.23 mb -
Furnace
Louisville Tin and Stove W351F
20 páginas 0.23 mb -
Furnace
Louisville Tin and Stove CDV255B
2 páginas 0.02 mb -
Furnace
Louisville Tin and Stove W502F W255F
20 páginas 0.23 mb -
Furnace
Louisville Tin and Stove DVCF653B-R
22 páginas 0.28 mb -
Furnace
Louisville Tin and Stove W255F
25 páginas 0.3 mb -
Furnace
Louisville Tin and Stove DVCF557B-R
22 páginas 0.28 mb -
Furnace
Louisville Tin and Stove HEDV253A
2 páginas 0.18 mb
Bom manual de uso
As regras impõem ao revendedor a obrigação de fornecer ao comprador o manual com o produto Louisville Tin and Stove DVCF653B-R. A falta de manual ou informações incorretas fornecidas ao consumidor são a base de uma queixa por não conformidade do produto com o contrato. De acordo com a lei, pode anexar o manual em uma outra forma de que em papel, o que é frequentemente utilizado, anexando uma forma gráfica ou manual electrónicoLouisville Tin and Stove DVCF653B-R vídeos instrutivos para os usuários. A condição é uma forma legível e compreensível.
O que é a instrução?
A palavra vem do latim "Instructio" ou instruir. Portanto, no manual Louisville Tin and Stove DVCF653B-R você pode encontrar uma descrição das fases do processo. O objetivo do manual é instruir, facilitar o arranque, a utilização do equipamento ou a execução de determinadas tarefas. O manual é uma coleção de informações sobre o objeto / serviço, um guia.
Infelizmente, pequenos usuários tomam o tempo para ler o manual Louisville Tin and Stove DVCF653B-R, e um bom manual não só permite conhecer uma série de funcionalidades adicionais do dispositivo, mas evita a formação da maioria das falhas.
Então, o que deve conter o manual perfeito?
Primeiro, o manual Louisville Tin and Stove DVCF653B-R deve conte:
- dados técnicos do dispositivo Louisville Tin and Stove DVCF653B-R
- nome do fabricante e ano de fabricação do dispositivo Louisville Tin and Stove DVCF653B-R
- instruções de utilização, regulação e manutenção do dispositivo Louisville Tin and Stove DVCF653B-R
- sinais de segurança e certificados que comprovam a conformidade com as normas pertinentes
Por que você não ler manuais?
Normalmente, isso é devido à falta de tempo e à certeza quanto à funcionalidade específica do dispositivo adquirido. Infelizmente, a mesma ligação e o arranque Louisville Tin and Stove DVCF653B-R não são suficientes. O manual contém uma série de orientações sobre funcionalidades específicas, a segurança, os métodos de manutenção (mesmo sobre produtos que devem ser usados), possíveis defeitos Louisville Tin and Stove DVCF653B-R e formas de resolver problemas comuns durante o uso. No final, no manual podemos encontrar as coordenadas do serviço Louisville Tin and Stove na ausência da eficácia das soluções propostas. Atualmente, muito apreciados são manuais na forma de animações interessantes e vídeos de instrução que de uma forma melhor do que o o folheto falam ao usuário. Este tipo de manual é a chance que o usuário percorrer todo o vídeo instrutivo, sem ignorar especificações e descrições técnicas complicadas Louisville Tin and Stove DVCF653B-R, como para a versão papel.
Por que ler manuais?
Primeiro de tudo, contem a resposta sobre a construção, as possibilidades do dispositivo Louisville Tin and Stove DVCF653B-R, uso dos acessórios individuais e uma gama de informações para desfrutar plenamente todos os recursos e facilidades.
Após a compra bem sucedida de um equipamento / dispositivo, é bom ter um momento para se familiarizar com cada parte do manual Louisville Tin and Stove DVCF653B-R. Atualmente, são cuidadosamente preparados e traduzidos para sejam não só compreensíveis para os usuários, mas para cumprir a sua função básica de informação
Índice do manual
-
Página 1
DIRECT VENT COUNTERFLOW W ALL FURNACE INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 72900 - REV . 12/03 MODEL NUMBERS NA T . GAS DVCF407B-R DVCF557B-R L.P . GAS DVCF408B-R DVCF558B-R W ARNING: If the information in this manual is not followed exactly , a fir e or explosion may result causing pr operty damage, personal injury or loss of life. MODEL[...]
-
Página 2
CONTENTS Introduction………………………………. 2 Specifications and Dimensions…………… 2 Safety Rules………………………………. 3 Clearances………………………………… 4, 5 Location…………………………………… 6 Installation………………………………… 6 Operation………………?[...]
-
Página 3
SAFETY RULES 1. Follow all applicable local codes and ordinances. If there are none, follow the latest edition of the National Fuel Gas Code, ANSI.Z223.1. A copy may be obtained from American Gas Association, 1515 W ilson Blvd., Arlington, V irginia 22209, or the National Fire Protection Association, Batterymarch Park, Quincy , MA. 02269. In Canada[...]
-
Página 4
REFER ENCE LE TTER TO DRAWI NG CANADIAN I NSTALLA T A = C l earance abo ve grade, ve randa, porch, d eck, or b alcony 12 In ches (30 cm) B = C l earanc e to windo w or do or that may be open ed 12 In ches (30 cm) C = C learanc e to perma nent l y closed wi ndow 12 In ches (30 cm) D = Verti cal cl earance to ventil ated sof fi t l ocated a bove th e[...]
-
Página 5
CLEARANCES 1 . The minimum clearance to a side wall is 4”. (See Fig. 1). NOTE: The unit may be recessed and rest directly against side studs and the inside surface of the rear wall. 2. The minimum clearance to the ceiling is 4”. (See Figure 1). 3. The minimum clearance to the floor is 0”. (See Figure 1). 4. The minimum clearance from the side[...]
-
Página 6
LOCA TIONS 1. This furnace must be installed on an outside wall and vented to the outside. If possible, this wall should be on the side of the house that receives the least amount of wind since strong gusting winds could cause pilot outage. 2. For most ef ficient performance, locate furnace as centrally as possible in the area to be heated. 3. The [...]
-
Página 7
LOCA TE VENT OPENING After the location of the heater has been determined, the opening for the vent pipe should be cut. If the heater is to be recessed, cut out opening for heater between studs on the interior wall and cut out the floor plate between the studs, so heater will set flat on floor as all dimensions are given from a finished floor . The[...]
-
Página 8
LIGHTING INSTRUCTIONS: DVCF403B, DVCF404B, DVCF653B, DVCF654B FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injur y or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these in[...]
-
Página 9
LIGHTING INSTRUCTIONS: DVCF407B, DVCF408B, DVCF557B, DVCF558B FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try[...]
-
Página 10
PILOT ADJUSTMENT Locate the pilot adjustment screw on the valve. The pilot flame should surround at least the top 3/8” of the powerpile (pilot generator) or flame sensor (see Figure 7). The pilot is unregulated so it will be operating at inlet line pressure (Max. 7” w .c. for Natural Gas and 1 1” w .c. for Propane). T o decrease the pilot fla[...]
-
Página 11
DVCF403B, DVCF404B ST ANDING PILOT DVCF653B, DVCF654B THERMOST A T POWER CORD MOTOR GREEN WHITE BLACK BROWN BLACK TRANSFORMER BLUE BLACK LIMIT SWITCH FAN SWITCH AUXILIAR Y LIMIT SWITCH GAS V AL VE BLACK BLACK BLACK BLACK BLACK GREEN WHITE WHITE DVCF403, DVCF404 PICTORIAL SCHEMA TIC MODEL NO. AMPS DVCF403 1.95 DVCF404 1.95 MOT OR THERMOST A T POWER [...]
-
Página 12
DVCF407B, DVCF408B I.I.D. DVCF557B, DVCF558B THERMOST A T POWER CORD MOT OR GREEN GREEN WHITE WHITE BLACK BROWN BLACK WHITE BLACK BLUE BLACK TRANSFORMER LIMIT SWITCH F AN SWITCH PILOT AUXILIAR Y LIMIT SWITCH BLACK GAS V AL VE P C M TH PV SENSE MV MV/PV TR IGN SP715-NA T . OR SP735-L.P . SP715-NA T . OR SP735-L.P . TH PV SENSE MV MV/PV TR IGN THERMO[...]
-
Página 13
CAUTION: Label all wires prior to disconnection when servicing contr ols. Wiring errors can cause improper and danger ous operation. V erify proper operation after servicing. TERMINAL BLOCK WIRING DIAGRAM Fan/Limit Switch (Brown) Power Cord (Black) Transformer (Black) Selector Switch (Red) Motor (Red) Power Cord (Green) T erminal Board Ground (Gree[...]
-
Página 14
OPTIONAL SIDE DISCHARGE KITS SIDE DISCHARGE ON CASING 1. Use Optional Kit No. 306SR-A. 2. Cut out and remove embossed area on casing side. 3. Remove knockout from inner liner . 4 . Place 1-1/2” boot from kit through opening, matching flanges of boot to knockout on inner liner . 5. Mark screw holes and remove boot. 6. Drill holes with a 1/8” dri[...]
-
Página 15
14-PEK KIT INSTRUCTIONS (14’ PLUG EXTENSION KIT) FOR NON-RECESSED INST ALLA TIONS ONL Y 90 Degree Outside Corner 3 FT . SECTION W ALL 3 FT . SECTION BOTTOM SECTION 1 2 3 4 UNITS WITH TERMINAL BOARD STEP # 1. Turn heater of f following Section 3 in “Lighting Instructions” and allow to cool. 2. Turn of f all electricity to heater . 3. Remove to[...]
-
Página 16
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Flame too large 1. Defective operator section of valve. 1. Replace valve. 2. Burner orifice too large. 2. Check with local gas company for proper orifice size and replace. 3. If installed above 2,000 feet. 3. See orifice chart, page 10. Y ellow burner flame 1. Clogged burner ports. 1. Remove main burner and[...]
-
Página 17
Burner won’t turn on 1. Gas valve not turned on. 1. T urn gas valve to “on” position. 2. No voltage to valve. 2. Check for 24 V olts to valve from transformer . 3. Defective thermostat. 3. Check wall thermostat. 4. No 1 15 V . Line voltage. 4. Provide line voltage. 5. Gas valve defective. 5. Replace gas valve. 6. Manual reset switch not engag[...]
-
Página 18
DIRECT VENT COUNTERFLOW W ALL FURNACE SP ARK IGNITER - I.I.D. THERMOST A T VENT ASSEMLBY Prices and specifications subject to change without notice. All prices are F .O.B. factory . BURNER ASSEMBL Y DVCF40B-R, DVCF55B-R, DVCF65B-R SERIES Page 18 55 14 15 54 12 25b 28b 28 25 34 58 13 13b 41 53 57 56 31 59 60 32 33 43 23 40 37 49 48 47 46 45 39 1g 51[...]
-
Página 19
NA T . DVCF403B-R DVCF407B-R DVCF557B-R DVCF653B-R MODEL NUMBER L . P . DVCF404B-R DVCF408B-R DVCF558B-R DVCF654B-R R EF . P AR T LIST P AR T LIST P A R T LIST P AR T LIST P ART DESCRIPTION NO. NO. PRICE N O . PRICE N O . P R IC E N O . PRICE Casing Side, Right 1a 34065 $56.10 34065 $56.10 34560 $61.30 34560 $61.30 Casing Side, Left 1b 34055 $56.10[...]
-
Página 20
NA T . DVCF403B-R DVCF407B-R DVCF557B-R DVCF653B-R MODEL NUMBER L. P . DVCF404B-R DVCF408B -R DVCF558B-R DVCF654B-R RE F . P ART LIST P ART LIST P A RT LIST P ART LIST P ART DESCRIPTION N O . N O . PRICE N O . PRICE N O . PRICE N O . PRICE Power Cord N/A 78213 $4.70 78213 $4.70 78213 $4.70 78213 $4.70 Sight Glass Assembly 31 43252 $6.50 43252 $6.50[...]
-
Página 21
IMPOR T ANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEA TING EQUIPMENT WHA T YOU DON’T KNOW CAN HUR T YOU. Y our pilot light system has been designed for safe and reliable operation. Although safety mechanisms are built-in, the potential for hazard exists. This information is intended to help you avoid these hazards. YOUR G[...]
-
Página 22
The Louisville Tin & Stove Co. warrants to the original user the accompanying product for the period specified herein, provided said product is installed, operated, maintained, serviced, and used according to the instructions and specifications accompanying the product. AS OUTLINED IN OUR INSTRUCTIONS, ANY W ARRANTY CONSIDERA TIONS ARE CONTINGE[...]