Ir para a página of
Manuais similares
-
Computer Accessories
National Instruments 370757C-01
71 páginas 0.55 mb -
Computer Accessories
National Instruments 321518A-01
55 páginas 0.66 mb -
Computer Accessories
National Instruments NI USB-9237
23 páginas 0.71 mb -
Computer Accessories
National Instruments NI-DAQ mx Base
18 páginas 0.42 mb -
Computer Accessories
National Instruments NI-CANTM Software for Windows NT
49 páginas 0.57 mb -
Computer Accessories
National Instruments VirtualBench
55 páginas 0.66 mb -
Computer Accessories
National Instruments PXI-8461
49 páginas 0.57 mb -
Computer Accessories
National Instruments 321042A-01
53 páginas 0.32 mb
Bom manual de uso
As regras impõem ao revendedor a obrigação de fornecer ao comprador o manual com o produto National Instruments VirtualBench. A falta de manual ou informações incorretas fornecidas ao consumidor são a base de uma queixa por não conformidade do produto com o contrato. De acordo com a lei, pode anexar o manual em uma outra forma de que em papel, o que é frequentemente utilizado, anexando uma forma gráfica ou manual electrónicoNational Instruments VirtualBench vídeos instrutivos para os usuários. A condição é uma forma legível e compreensível.
O que é a instrução?
A palavra vem do latim "Instructio" ou instruir. Portanto, no manual National Instruments VirtualBench você pode encontrar uma descrição das fases do processo. O objetivo do manual é instruir, facilitar o arranque, a utilização do equipamento ou a execução de determinadas tarefas. O manual é uma coleção de informações sobre o objeto / serviço, um guia.
Infelizmente, pequenos usuários tomam o tempo para ler o manual National Instruments VirtualBench, e um bom manual não só permite conhecer uma série de funcionalidades adicionais do dispositivo, mas evita a formação da maioria das falhas.
Então, o que deve conter o manual perfeito?
Primeiro, o manual National Instruments VirtualBench deve conte:
- dados técnicos do dispositivo National Instruments VirtualBench
- nome do fabricante e ano de fabricação do dispositivo National Instruments VirtualBench
- instruções de utilização, regulação e manutenção do dispositivo National Instruments VirtualBench
- sinais de segurança e certificados que comprovam a conformidade com as normas pertinentes
Por que você não ler manuais?
Normalmente, isso é devido à falta de tempo e à certeza quanto à funcionalidade específica do dispositivo adquirido. Infelizmente, a mesma ligação e o arranque National Instruments VirtualBench não são suficientes. O manual contém uma série de orientações sobre funcionalidades específicas, a segurança, os métodos de manutenção (mesmo sobre produtos que devem ser usados), possíveis defeitos National Instruments VirtualBench e formas de resolver problemas comuns durante o uso. No final, no manual podemos encontrar as coordenadas do serviço National Instruments na ausência da eficácia das soluções propostas. Atualmente, muito apreciados são manuais na forma de animações interessantes e vídeos de instrução que de uma forma melhor do que o o folheto falam ao usuário. Este tipo de manual é a chance que o usuário percorrer todo o vídeo instrutivo, sem ignorar especificações e descrições técnicas complicadas National Instruments VirtualBench, como para a versão papel.
Por que ler manuais?
Primeiro de tudo, contem a resposta sobre a construção, as possibilidades do dispositivo National Instruments VirtualBench, uso dos acessórios individuais e uma gama de informações para desfrutar plenamente todos os recursos e facilidades.
Após a compra bem sucedida de um equipamento / dispositivo, é bom ter um momento para se familiarizar com cada parte do manual National Instruments VirtualBench. Atualmente, são cuidadosamente preparados e traduzidos para sejam não só compreensíveis para os usuários, mas para cumprir a sua função básica de informação
Índice do manual
-
Página 1
Getting Started with VirtualBench ™ Getting Started with VirtualBench March 1997 Edition Part Number 321518A-01 © Copyright 1997 National Instruments Corporation. All rights reserved. 01Title.fm Page 1 Friday, February 28, 1997 3:19 PM[...]
-
Página 2
support@natinst.com E-mail: info@natinst.com FTP Site: ftp.natinst.com Web Address: http://www.natinst.com BBS United States: (512) 794-5422 BBS United Kingdom: 01635 551422 BBS France: 01 48 65 15 59 (512) 418-1111 Tel: (512) 795-8248 Fax: (512) 794-5678 Australia 02 9874 4100, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Canada (Ontario) 905 78[...]
-
Página 3
Important Information Warranty The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, du e to defect s in materi als and wor kmanshi p, for a peri od of 90 day s from dat e of ship ment, as ev idenced by receipts or other documentation. National Instruments will, at its option, re[...]
-
Página 4
© National Instruments Corporation v Getting Started with VirtualBench Contents About This Manual Conventions Used in This Manual ................................................................................... vii Customer Communication ............................................................................................... viii Chapter[...]
-
Página 5
Contents Getting Started with VirtualBench vi © National Instruments Corporation Chapter 6 VirtualBench-DMM Front Panel Features ........................................................................................................ 6-1 Measuring a Signal ............................................................................................[...]
-
Página 6
© National Instruments Corporation vii Ge t ti ng St a rt ed w it h V ir t ua l Be nc h About This Manual The VirtualBench suite of tools is a high-performance, easy-to-use virtual instruments application program for Microsoft Windows 3.1x, Windows 95, or Windows NT. Getting Started with VirtualBench gives you step-by-step instructions on how to u[...]
-
Página 7
Ge tt i ng S ta r te d w i th V ir t ua lB e nc h viii © National Instruments Corporation About This Manual paths Paths in this manual are denoted using backslashes () to separate drive names, directories, and files, as in C:dir1namedir 2namefilename . This icon to the left of bold, italicized text denotes a note, which alerts you to important[...]
-
Página 8
© National Instruments Corporation 1-1 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Chapter 1 Welcome to VirtualBench Welcome to VirtualBench, a suite of high-performance, easy-to-use virtual instruments for Microsoft Windows 3.1x, Windows 95, and Windows NT. This document contains installation instructions, lists of system requirements and ne[...]
-
Página 9
Chapter 1 Welcome to VirtualBench Getting Started with VirtualBench 1-2 © National Instruments Corporation • NI-DAQ 4.9.0 if you plan to use an AT-DSP2200, AT-A2150, or EISA-A2000 DAQ device • NI-DAQ 5.0 or later if you plan to use Microsoft Windows NT 4.0 or later, or if you plan to use any of the following new DAQ devices: – PCI-MIO-16E-1 [...]
-
Página 10
Chapter 1 Welcome to VirtualBench © National Instruments Corporation 1-3 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Note: It is recommended that you not run other applications while you install VirtualBench. 3. Insert Disk 1 into your 3.5-inch floppy disk drive. 4. Select Run from the File menu in the Program Manager. 5. Enter A:setup or B:s[...]
-
Página 11
Chapter 1 Welcome to VirtualBench Getting Started with VirtualBench 1-4 © National Instruments Corporation What Is Installed by the Setup Program If you purchased the full VirtualBench suite, the setup program installs the VirtualBench engine and nine virtual instruments: the oscilloscope (Scope), dynamic signal analyzer (DSA), digital multimeter [...]
-
Página 12
© National Instruments Corporation 2-1 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Chapter 2 VirtualBench-Scope In Windows 3.1x, you launch VirtualBench-Scope by double-clicking on the Scope icon in the VirtualBench window within the Program Manager. In Windows 95/NT 4.0, you launch VirtualBench-Scope by selecting Start»Programs»VirtualBen [...]
-
Página 13
Chapter 2 VirtualBench-Scope Getting Started with VirtualBench 2-2 © National Instruments Corporation The front panel of VirtualBench-Scope has the following features: • Channel Selector — selects a waveform for display on the Graphics display. • Channel Settings —adjusts the vertical sensitivity of the select ed channel. Turning the knob [...]
-
Página 14
Chapter 2 VirtualBench-Scope © National Instruments Corporation 2-3 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Acquiring Data You can start acquiring signals with VirtualBench-Scope by completing the following steps : 1. Connect a signal to the Channel 0 input of your National Instruments DAQ device. See the user manual of your DAQ device fo[...]
-
Página 15
Chapter 2 VirtualBench-Scope Getting Started with VirtualBench 2-4 © National Instruments Corporation d. Click on OK to use these settings . 3. Save your settings by selecting Edit»Save Settings from the pull-down menu on the front panel. Enter the name of the file you want to save, for example MyScope.set . Note: When you launch VirtualBench-Sco[...]
-
Página 16
© National Instruments Corporation 3-1 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Chapter 3 VirtualBench-Logger In Windows 3.1x, you launch VirtualBench-Logger by double-clicking on the Logger icon in the VirtualBench program group. In Windows 95/NT 4.0, you launch VirtualBench-Logger by selecting Start»Programs»VirtualBench»VirtualBench-[...]
-
Página 17
Chapter 3 VirtualBench-Logger Getting Started with VirtualBench 3-2 © National Instruments Corporation The front panel of VirtualBench-Logger has the following features: • Strip Chart Display — displays the logged data. • Y-Axis Select Controls — selects which channel Y scale to display on either the left or right Y axis of the Strip Chart[...]
-
Página 18
Chapter 3 VirtualBench-Logger © National Instruments Corporation 3-3 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Acquiring Data You can start acquiring data with VirtualBench-Logger by following these steps: 1. Connect several known voltage signals to the input channels of your DAQ device. See the user manual of your DAQ device for details. I[...]
-
Página 19
Chapter 3 VirtualBench-Logger Getting Started with VirtualBench 3-4 © National Instruments Corporation d. Set the channel attributes for each channel from the Start to End Channel. Give each channel an appropriate label for easy identification on the Strip Chart display. e. Click on the File Config button. Specify the name of the Log file where th[...]
-
Página 20
Chapter 3 VirtualBench-Logger © National Instruments Corporation 3-5 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h g. Click on OK in the Logger Settings dialog box to return to the front panel. 3. Select the channels that you want to display on the strip chart using the Channel Select Control. 4. Use the right and left Y-axis Controls to select[...]
-
Página 21
© National Instruments Corporation 4-1 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Chapter 4 VirtualBench-DSA In Windows 3.1x, you launch VirtualBench-DSA (Dynamic Signal Analyzer) by double-clicking on the DSA icon in the VirtualBench program group. In Windows 95/NT 4.0, you launch VirtualBench-DSA by selecting Start»Programs»VirtualBench?[...]
-
Página 22
Chapter 4 VirtualBench-DSA Getting Started with VirtualBench 4-2 © National Instruments Corporation log/linear mode, phase unit, and markers in this control. You can refer to the online help for a detailed description of each component. • Display 1/Display 2 Controls —changes the marker positions and display attributes of the respective displa[...]
-
Página 23
Chapter 4 VirtualBench-DSA © National Instruments Corporation 4-3 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Acquiring and Measuring Signals You can start acquiring and measuring signals with VirtualBench-DSA by following these steps: 1. Connect a signal to the Channel 0 or 1 input of your DAQ device. Please refer to the user manual of your [...]
-
Página 24
Chapter 4 VirtualBench-DSA Getting Started with VirtualBench 4-4 © National Instruments Corporation f. Click on the Acquisition tab in the DSA Settings dialog box. g. Set the Frame Size control to 1024. VirtualBench-DSA will analyze data in blocks of 1024 points. h. Select a Sample Rate that is at least twice the maximum frequency that you are try[...]
-
Página 25
Chapter 4 VirtualBench-DSA © National Instruments Corporation 4-5 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h j. Click on the Triggering tab in the DSA Settings dialog box. k. Set the Trigger Type to none. This setting puts the acquisition in a Freerun mode. l. Click on OK . 3. Change the display indicator (left and right arrow buttons) to Di[...]
-
Página 26
Chapter 4 VirtualBench-DSA Getting Started with VirtualBench 4-6 © National Instruments Corporation Display Control. Check your signal connections if data is still not visible. 10. Click on Run . VirtualBench-DSA continuously acquires and displays frames of data. 11. Click on Run again to stop acquisition. Note: Please refer to the VirtualBench-DS[...]
-
Página 27
© National Instruments Corporation 5-1 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Chapter 5 VirtualBench-FG In Windows 3.1x, you launch VirtualBench-FG (Function Generator) by double-clicking on the FG icon in the VirtualBench program group. In Windows 95/NT 4.0, you launch VirtualBench-FG by selecting Start»Programs»VirtualBench»VirtualB[...]
-
Página 28
Chapter 5 VirtualBench-FG Getting Started with VirtualBench 5-2 © National Instruments Corporation • Waveform Modifier Controls —modifies some of the properties of the waveform. – Duty Cycle —adjusts the duty cycles of the Sine Wave, Square Wave, and Triangle Wave. – Offset —adjus ts the DC offset of the waveform. – Amplitude —adju[...]
-
Página 29
Chapter 5 VirtualBench-FG © National Instruments Corporation 5-3 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h 2. Connect a device or scope to the output of the analog output device that you specified in step one. See your DAQ device user manual for details. 3. Click on Run . VirtualBench-FG continuously generates an analog waveform at the outp[...]
-
Página 30
© National Instruments Corporation 6-1 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Chapter 6 VirtualBench-DMM In Windows 3.1x, you launch VirtualBench-DMM (Digital Multimeter) by double-clicking on the DMM icon in the VirtualBench program group. In Windows 95/NT 4.0, you launch VirtualBench-DMM by selecting Start»Programs»VirtualBen ch»Vir[...]
-
Página 31
Chapter 6 VirtualBench-DMM Getting Started with VirtualBench 6-2 © National Instruments Corporation – Current AC — measures the AC component of a current source. – Ohms — measures resistance. – Temperature — measures tem perature. – Diode — measures the voltage drop across a diode. Note: Diode mode is only available when you are us[...]
-
Página 32
Chapter 6 VirtualBench-DMM © National Instruments Corporation 6-3 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Measuring a Signal You can start measuring signals with VirtualBench-DMM by following these steps: 1. Configure VirtualBench-DMM. a. Select Settings from the Edit menu on the front panel. b. Select the General tab. c. Select the Devic[...]
-
Página 33
Chapter 6 VirtualBench-DMM Getting Started with VirtualBench 6-4 © National Instruments Corporation c. Click on Run . VirtualBench-DMM continuously acquires and displays voltage measurements in the display window. d. Check to see that the input signal does not exceed the range of your DAQ device, and that the input signal does not exceed the selec[...]
-
Página 34
Chapter 6 VirtualBench-DMM © National Instruments Corporation 6-5 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h i. Check to see that the input signal does not exceed the range of your DAQ device, and that the input signal does not exceed the selected range, when the DMM display shows +CLIP or -CLIP. j. Click on Run again to stop the measurement[...]
-
Página 35
Chapter 6 VirtualBench-DMM Getting Started with VirtualBench 6-6 © National Instruments Corporation c. Select the Temperature tab. d. Select the type of sensor that you connected to the channel specified in step one, in substep "a", from the Temperature Sensor list. e. Select the Temperature Units you want the temperature to be displayed[...]
-
Página 36
Chapter 6 VirtualBench-DMM © National Instruments Corporation 6-7 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h 6. Measuring a diode. If you are using a DAQCard-4050 device, you may measure the voltage drop across a diode, up to two volts. a. Connect the diode to the terminals of the DAQCard-4050. b. Click on the sixth (diode) button in the mov[...]
-
Página 37
© National Instruments Corporation 7-1 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Chapter 7 VirtualBench-Arb In Windows 3.1x, you launch VirtualBench-Arb (Arbitrary Waveform Generator) by double-clicking on the Arb icon in the VirtualBench program group. In Windows 95/NT 4.0, you launch VirtualBench-Arb by selecting Start»Programs»VirtualB[...]
-
Página 38
Chapter 7 VirtualBench-Arb Getting Started with VirtualBench 7-2 © National Instruments Corporation • Amplitude Control — scales the waveform by a specified amount. • Offset Control —adds a voltage offset to the waveform. • Phase Control — shifts the waveform buffer by a certain phase, specified in degrees. • Play/Stop Control — st[...]
-
Página 39
Chapter 7 VirtualBench-Arb © National Instruments Corporation 7-3 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h The Waveform Editor front panel of VirtualBench-Arb has the following features: • View Control — selects the waveform view displayed on the graph. Waveform displays the entire waveform. Segment displays the first of the selected s[...]
-
Página 40
Chapter 7 VirtualBench-Arb Getting Started with VirtualBench 7-4 © National Instruments Corporation Generating a Waveform You can start generating waveforms with VirtualBench-Arb by following these steps: 1. Configure VirtualBench-Arb. a. Select Settings from the Edit menu on the front panel. b. Select the Channels tab. c. Select the Device that y[...]
-
Página 41
Chapter 7 VirtualBench-Arb © National Instruments Corporation 7-5 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h c. Click on New Component . By default, every time you click on New Component , a new library component is added to any existing waveform. d. Select the type of component: Library, Expression, or Sketch. The following steps further de[...]
-
Página 42
Chapter 7 VirtualBench-Arb Getting Started with VirtualBench 7-6 © National Instruments Corporation c. Select Sketch from the Component Type control. d. Click on Draw . Notice that this changes from View to Component mode, so that only the current component is displayed. e. Click and drag over the graph to create a waveform using the mouse. Change[...]
-
Página 43
© National Instruments Corporation 8-1 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Chapter 8 VirtualBench-AODC In Windows 3.1x, you launch VirtualBench-AODC (Analog Output Direct Current) by double-clicking on the AODC icon in the VirtualBench program group. In Windows 95/NT4.0, you launch VirtualBench-AODC by selecting Start»Programs»Virtu[...]
-
Página 44
Chapter 8 VirtualBench-AODC Getting Started with VirtualBench 8-2 © National Instruments Corporation Controlling Analog Output You can start controlling analog output with VirtualBench-AODC by following these steps: 1. Configure VirtualBench-AODC. a. Select Settings from the Edit menu on the front panel. b. Click on the General tab in the AODC Set[...]
-
Página 45
Chapter 8 VirtualBench-AODC © National Instruments Corporation 8-3 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h d. Click on the AO Channels tab on the AODC Settings dialog box. e. Select the Range and Initial Voltage (V) or Current (mA) for each channel in the Channels list. f. Click on OK to use these settings. 2. Use the Channel control to a[...]
-
Página 46
© National Instruments Corporation 9-1 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h Chapter 9 VirtualBench-DIO In Windows 3.1x, you launch VirtualBench-DIO (Digital Input/Output) by double-clicking on the DIO icon in the VirtualBench program group. In Windows 95/NT 4.0, you launch VirtualBench-DIO by selecting Start»Programs»VirtualBench»Vi[...]
-
Página 47
Chapter 9 VirtualBench-DIO Getting Started with VirtualBench 9-2 © National Instruments Corporation • Hex Control — sets the digital state, in hexadecimal form, of the assigned digital port. The state of the digital port is not actually changed until the Write button is clicked on. • Hex Indicator — shows the current state, in hexadecimal [...]
-
Página 48
Chapter 9 VirtualBench-DIO © National Instruments Corporation 9-3 Ge t ti ng St a rt ed w it h V ir t ua l Be nc h c. Select the Device and SCXI Module that you want to use. The SCXI Module list is disabled if no SCXI modules are configured for the selected device. The device must be successfully configured in the NI-DAQ Configuration Utility to a[...]
-
Página 49
© National Instruments Corporation 10-1 Get ti n g S t ar te d w it h V i rt u al Be n ch Chapter 10 VirtualBench- Device Calibrator In Windows 3.1x, you launch the VirtualBench-Device Calibrator by double-clicking on the Calibrate icon in the VirtualBench program group. In Windows 95/NT4.0, you launch the VirtualBench-Device Calibrator by selecti[...]
-
Página 50
Chapter 10 Virtual Bench-Device Calibrator Getting Started with VirtualBench 10 -2 © National Instruments Corporation Calibrating a DAQ Device You can calibrate your device with VirtualBench-Device Calibrator by following these steps: 1. Wait at least 15 minutes after both your computer and device are powered on before calibrating your device. 2. [...]
-
Página 51
© National Instruments Corporation A-1 Getting Started with VirtualBench Appendix Customer Communication For your convenience, this appendix contains forms to help you gather the information necessary to help us solve your technical problems and a form you can use to comment on the product documentation. When you contact us, we need the informatio[...]
-
Página 52
Fax-on-Demand is a 24-hour information retrieval system containing a library of documents on a wide range of technical information. You can access Fax-on-Demand from a touch-tone telephone at (512) 418-1111. You can submit technical support questions to the applications engineering team through e-mail at the Internet address listed below. Remember [...]
-
Página 53
Technical Support Form Photocopy this form and update it each time you make changes to your software or hardware, an d use the completed copy of this form as a reference for your current configuration. Completing this form accurately before contacting National Instruments for technical support helps our applications engineers answer your questions [...]
-
Página 54
VirtualBench Hardware and Software Configuration Form Record the settings and revisions of your hardware and software on the line to the right of each item. Complete a new copy of this form each time you revise your software or hardware configuration, and use this form as a reference for your current configuration. Completing this form accurately b[...]
-
Página 55
Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products. This information helps us provide quality products to meet your needs. Title: Getting Started with VirtualBench ™ Edition Date: March 1997 Part Number: 321518A-01 Please comment on the completeness, clarity, and organization [...]