Ir para a página of
Manuais similares
-
Water Heater
State Industries 201 Series
2 páginas 2.38 mb -
Water Heater
State Industries SUF 100 THRU 250
49 páginas 8.46 mb -
Water Heater
State Industries CSB 120
2 páginas 0.82 mb -
Water Heater
State Industries SBD85500PE
52 páginas 6.07 mb -
Water Heater
State Industries XCVIT
20 páginas 0.29 mb -
Water Heater
State Industries STC-077
46 páginas 5.95 mb -
Water Heater
State Industries SCGSS00107
1 páginas 1.19 mb -
Water Heater
State Industries STC-080
36 páginas 1.82 mb
Bom manual de uso
As regras impõem ao revendedor a obrigação de fornecer ao comprador o manual com o produto State Industries 184748-001. A falta de manual ou informações incorretas fornecidas ao consumidor são a base de uma queixa por não conformidade do produto com o contrato. De acordo com a lei, pode anexar o manual em uma outra forma de que em papel, o que é frequentemente utilizado, anexando uma forma gráfica ou manual electrónicoState Industries 184748-001 vídeos instrutivos para os usuários. A condição é uma forma legível e compreensível.
O que é a instrução?
A palavra vem do latim "Instructio" ou instruir. Portanto, no manual State Industries 184748-001 você pode encontrar uma descrição das fases do processo. O objetivo do manual é instruir, facilitar o arranque, a utilização do equipamento ou a execução de determinadas tarefas. O manual é uma coleção de informações sobre o objeto / serviço, um guia.
Infelizmente, pequenos usuários tomam o tempo para ler o manual State Industries 184748-001, e um bom manual não só permite conhecer uma série de funcionalidades adicionais do dispositivo, mas evita a formação da maioria das falhas.
Então, o que deve conter o manual perfeito?
Primeiro, o manual State Industries 184748-001 deve conte:
- dados técnicos do dispositivo State Industries 184748-001
- nome do fabricante e ano de fabricação do dispositivo State Industries 184748-001
- instruções de utilização, regulação e manutenção do dispositivo State Industries 184748-001
- sinais de segurança e certificados que comprovam a conformidade com as normas pertinentes
Por que você não ler manuais?
Normalmente, isso é devido à falta de tempo e à certeza quanto à funcionalidade específica do dispositivo adquirido. Infelizmente, a mesma ligação e o arranque State Industries 184748-001 não são suficientes. O manual contém uma série de orientações sobre funcionalidades específicas, a segurança, os métodos de manutenção (mesmo sobre produtos que devem ser usados), possíveis defeitos State Industries 184748-001 e formas de resolver problemas comuns durante o uso. No final, no manual podemos encontrar as coordenadas do serviço State Industries na ausência da eficácia das soluções propostas. Atualmente, muito apreciados são manuais na forma de animações interessantes e vídeos de instrução que de uma forma melhor do que o o folheto falam ao usuário. Este tipo de manual é a chance que o usuário percorrer todo o vídeo instrutivo, sem ignorar especificações e descrições técnicas complicadas State Industries 184748-001, como para a versão papel.
Por que ler manuais?
Primeiro de tudo, contem a resposta sobre a construção, as possibilidades do dispositivo State Industries 184748-001, uso dos acessórios individuais e uma gama de informações para desfrutar plenamente todos os recursos e facilidades.
Após a compra bem sucedida de um equipamento / dispositivo, é bom ter um momento para se familiarizar com cada parte do manual State Industries 184748-001. Atualmente, são cuidadosamente preparados e traduzidos para sejam não só compreensíveis para os usuários, mas para cumprir a sua função básica de informação
Índice do manual
-
Página 1
1 PRINTED IN THE U.S.A. 1004 P ART NO. 184748-001 supersedes 184748-000 KEEP THIS MANUAL IN THE POCKET ON HEA TER FOR FUTURE REFERENCE WHEN EVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED. ALL TECHNICAL AND W ARRANTY QUESTIONS: SHOULD BE DIRECTED T O THE LOCAL DEALER FROM WHOM THE W A TER HEA TER WAS PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WR[...]
-
Página 2
2 SAFE INST ALLA TION , USE AND SERVICE Y our safety and the safety of others is extremely import ant in the inst allation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safet[...]
-
Página 3
3 GENERAL SAFETY[...]
-
Página 4
4 Thank Y ou for purchasing this water heater . Properly inst alled and maintained, it should give you years of trouble free service. Abbreviations Found In This Instruction Manual: • ANSI - American National S tandards Institute • ASME - American Society of Mechanical Engineers • GAMA - Gas Appliance Manufacturers Association • NEC - Natio[...]
-
Página 5
5 TYPICAL INST ALLA TION FIGURE 1. INST ALL V ACUUM RELIEF IN COLD W A TER INLET LINE AS REQUIRED BY LOCAL CODES. INST ALL SUIT ABLE DRAIN PAN S UNDER HEA TERS TO PREVENT DAMAGE DUE TO LEAKAGE. REFER TO W A TER HEA TER LOCA TION ON P AGE 8. INST ALL THERMAL EXPANSION T ANK OR DEVICE IF W A TER HEA TER IS INST ALLED IN A CLOSED W A TER SYSTEM.[...]
-
Página 6
6 MIXING VAL VE USAGE FIGURE 2. W ater (Pot able) Heating: All models are considered suitable for water (potable) heating only . HOTTER W A TER CAN SCALD: W ater heaters are intended to produce hot water. W ater heated to a temperature which will satisfy space heating, clothes washing, dish washing, and other sanitizing needs can scald and permanen[...]
-
Página 7
7 Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor . When such locations cannot be avoided, a suitable drain p an should be installed unde[...]
-
Página 8
8 The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heater’s temperature-pressure relief valve is reached, the valve will relieve the excess pressure. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. [...]
-
Página 9
9 The valve is certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment of materials as meeting the requirements for Relief V alves and Automatic Gas Shut-off Devices for Hot Water Supply Systems, ANSI Z21.22 • CSA 4.4, and the code requirements of ASME. If replaced, the valve mu[...]
-
Página 10
10 T o fill the water heater with water: 1. Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater . 2. Open the cold water supply valve to the water heater . NOTE: The cold water supply valve must be left open when the water heater is in use. 3. T o insure comple[...]
-
Página 11
11 WIRING DIAGRAMS TURN OFF THE HEA TER ELECTRICAL SUPPL Y BEFORE SERVICING ANY ELECTRICAL COMPONENTS. FIGURE 7.[...]
-
Página 12
12 WIRING Never use water heater unless it is completely full of water . T o prevent damage to the tank and heating element, the tank must be filled with water . Water must flow from the hot water faucet before turning on power . Y ou must provide all wiring of the proper size outside of the water heater . Y ou must obey local codes and electric co[...]
-
Página 13
13 TEMPERA TURE ADJUSTMENT T o change the temperature setting: NOTE: It is not necessary to adjust the upper thermostat. However , if it is adjusted above the factory set point (120°F (49°C)/HOT) it is recommended that it not be set higher than the lower thermostat setting. 1. T urn “OFF” the heater electrical supply . Do not attempt to adjus[...]
-
Página 14
14 THERMAL EXP ANSION W ater supply systems may , because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc. to control these types of problems. When these devices are not equipped with an internal by-pas[...]
-
Página 15
15 If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater , follow the draining instructions, and replace the temperature-pressure relief valve with a new one. If the temperature-pressure relief valve on the appliance weeps or discharges periodic[...]
-
Página 16
16 1 . Turn “OFF” the electric power supply to the water heater . 2 . Remove the outer door , insulation block and pad in the order they are installed. 3. A . Models with lower thermostat without high limit: Lift out the tab as shown below to unclip the terminal cover from the thermostat. The terminal cover can now be removed from the thermosta[...]
-
Página 17
17 The water passing out of the drain valve may be extremely hot. T o avoid scalding, make sure all connections are tight and that the water flow is directed away from any person. 4 . Remove the two screws securing the outer door , and remove door . FIGURE 15. 5. Remove the insulation block and pad. FIGURE 16. 6. A . Models with lower thermostat wi[...]
-
Página 18
18 1 1. Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater . 1 2 . Open the cold water supply valve to the water heater . NOTE: The cold water supply valve must be left open when the water heater is in use. 13. T o insure complete filling of the t ank, allow a[...]
-
Página 19
19 LEAKAGE CHECKPOINTS Read this manual first. Then before checking the water heater make sure the electrical power supply has been turned “OFF” before checking the tank for leakage. *A. Condensation and dripping may be seen on pipes if the water temperature is low in humid weather or pipe connections may be leaking. * B . The anode rod fitting[...]
-
Página 20
20 These guidelines should be utilized by a qualified service agent. TROUBLESHOOTING GUIDELINES Improperly sealed, hot or cold supply connection, relief valve or drain valve. Leakage from other appliances or water lines. Thermal expansion in closed water system. Improperly seated valve. High sulfate or mineral content in water supply . Bacteria in [...]
-
Página 21
21 REP AIR P ARTS LIST WHEN ORDERING REP AIR P ARTS, AL W A YS GIVE THE FOLLOWING INFORMA TION: • MODEL NUMBER • SERIAL NUMBER • VOL T AGE AND ELEMENT W A TT AGE • P AR T DESCRIPTION THIS IS A REP AIR P ARTS LIST , NOT A P ACKING LIST . Now that you have purchased this water heater , should a need ever exist for repair parts or service, sim[...]
-
Página 22
22 NOTES[...]
-
Página 23
23 NOTES[...]
-
Página 24
24[...]