American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40 инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 62 страниц
- 2.69 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Clothes Dryer
American Dryer Corp. AD-15
46 страниц 1.27 mb -
Clothes Dryer
American Dryer Corp. None
76 страниц 0.91 mb -
Clothes Dryer
American Dryer Corp. ML-79
49 страниц 0.39 mb -
Clothes Dryer
American Dryer Corp. AD-78 II
34 страниц 0.95 mb -
Clothes Dryer
American Dryer Corp. AD-25V
56 страниц 1.59 mb -
Clothes Dryer
American Dryer Corp. ML-75
54 страниц 1.57 mb -
Clothes Dryer
American Dryer Corp. AD-75
50 страниц 1.31 mb -
Clothes Dryer
American Dryer Corp. Gas DSI/Electric/ Steam AD-78 II
34 страниц 34.05 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40 или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40 можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40 должна находится:
- информация относительно технических данных устройства American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40
- название производителя и год производства оборудования American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40
- правила обслуживания, настройки и ухода за оборудованием American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40 это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40 и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта American Dryer Corp., в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
D-40 (Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E.) Installation Manual For replacement parts, contact the reseller from which the dryer was purchased or American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: techsupport@amdry.com www.amdry.com WARNING: For your safety the inf[...]
-
Страница 2
D-40 Retain This Manual In A Safe Place For Future Reference American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipment. OBSERVE ALL SAFETY [...]
-
Страница 3
IMPORTANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS. CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON[...]
-
Страница 4
WARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/ or specified in the installation manual included with the dryer. Dryers must not be installed or stored in an area where it[...]
-
Страница 5
SECTION I IMPORTANT INFORMATION .......................................................................... 3 A. Receiving and Handling ............................................................................................................... 3 B. Safety Precautions ...............................................................................[...]
-
Страница 6
SECTION VI ROUTINE MAINTENANCE ............................................................................ 42 A. Cleaning ................................................................................................................................... 42 B. Adjustments .............................................................................[...]
-
Страница 7
3 SECTION I IMPOR T ANT INFORMA TION A. RECEIVING AND HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and packaging, and wooden skid should be visually inspected for shipping damage. If any damage w[...]
-
Страница 8
4 B. SAFETY PRECAUTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESUL[...]
-
Страница 9
5 WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create a fire hazard. WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubber materials. Drying in a heated basket (tumbler) may damage plastics or rubber and also may be a fire hazard. 7. A program should be[...]
-
Страница 10
6 SECTION II SPECIFICA TIONS A. SPECIFICA TIONS * D-40 reversing dryer available with 3-phase (3ø) 1/2 HP (0.373 kw) motors standard. ** Size of piping to dryer varies with installation conditions. Contact factory for assistance. *** Contact factory for information not listed, 3-phase (3ø) figures shown are for 3-wire service. **** Specify air-op[...]
-
Страница 11
7 NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. Specifications[...]
-
Страница 12
8 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electric[...]
-
Страница 13
9 B. LOCA TION REQUIREMENTS Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1- M91 (Natu[...]
-
Страница 14
10 C. DR YER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 12-inches (30.48 cm) above the dryer’s outer top; 18-inches (45.72 cm) for steam dryers, except along the front of the dryer, which may be closed if desired. NOTE: Allowances must be made for opening the control[...]
-
Страница 15
11 D. FRESH AIR SUPPL Y REQUIREMENTS The D-40 air supply (make-up air) must be given careful consideration to assure proper performance of each dryer. An unrestricted source of air is necessary for each dryer. As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1-1/2 square feet (0.14 square meters) is req[...]
-
Страница 16
12 E. EXHAUST REQUIREMENTS Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure which results in slow drying, increased use of energy, and shutdown of the burner by the airflow (sail) switch, burner hi-limits, or lint chamber hi-limit protector thermostat. The d[...]
-
Страница 17
13 SINGLE DR YER VENTING IMPORTANT: For exhaust duct runs over 20 feet (6.1 meters) a minimum size of 10-inches (25.4 cm) must be used. HORIZONT AL VENTING When a single 8-inch (20.32 cm) horizontal vent is used, the ductwork to the outlet cannot exceed 20 feet (6.1 meters), refer to Illus. A below . This calculation of 20 feet (6.1 meters) compens[...]
-
Страница 18
14 VER TICAL VENTING When vertical single 10-inch (25.4 cm) venting is used (refer to Illus. B below ), the ductwork from the dryer to the outside outlet cannot exceed 40 feet (12.19 meters). This calculation compensates for the use of a maximum of three (3) elbows including the two (2) elbows creating the 180° (turned downward) outside outlet. Il[...]
-
Страница 19
15 MUL TIPLE DR YER (COMMON) VENTING If it is not feasible to provide separate exhaust ducts for each dryer, ducts for individual dryers may be channeled into a common main duct. Each dryer is provided with a back draft damper. The individual ducts should enter the bottom or side of the main duct at an angle not more than 45° in the direction of t[...]
-
Страница 20
16 HORIZONT AL VENTING Illus. C VER TICAL VENTING Illus. D[...]
-
Страница 21
17 IMPOR T ANT VENTING REMINDERS 1. Ductwork size and installation should be done by a qualified professional. 2. The dryer must be exhausted to the outdoors. 3. Ductwork should be routed as short as possible to the outdoors with as few elbows as possible. 4. Avoid 90° turns, use 30° or 45° turns instead. 5. The size of the ductwork must be a mi[...]
-
Страница 22
18 F . ELECTRICAL INFORMA TION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL electrical connections, materials,[...]
-
Страница 23
19 2) Electric Models ONLY ALL electrically heated dryers must be connected to the electric service shown on the dryer’s data label, which is affixed to the left side panel area behind the top control (access) door. The connecting wires must be properly sized to handle the rated current. NOTE: Electrically heated service (amperage) specifications[...]
-
Страница 24
20 If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord or pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer. SINGLE-PHASE (1Ø) ELECTRICAL CONNE[...]
-
Страница 25
21 5. 3-Phase (3ø) Wiring Connections/Hookup The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and sometimes Neutral) and ground. Single-phase (1ø) power for the control circuit is done internally to the dryer. No single-phase (1ø) input connection is required on a 3-phase (3ø) dryer. IMPORTANT: A[...]
-
Страница 26
22 CAUTION: The dryer must be grounded. A ground lug has been provided for this purpose. IMPORTANT: A CIRCUIT SER VICING EACH DR YER MUST BE PROVIDED. The only electrical connections to the dryer are the 3-phase (3ø) leads (L1, L2, L3, and sometimes Neutral) and ground. Single-phase (1ø) power for the control circuit is done by the factory at the[...]
-
Страница 27
23 IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact the factory. IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel area behind the top control (access) door. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric[...]
-
Страница 28
24 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requireme[...]
-
Страница 29
25 2. Technical Gas Data a. Gas Specifications *Measured at outlet side of gas valve pressure tap when gas valve is on. b. Gas Connections Inlet connection ------------- 1/2” N.P.T. Inlet supply size ------------- 1/2” N.P.T. (minimum) Heat input (per dryer) ------ 100,000 btu/hr (25,200 kcal/hr) 1) Natural Gas Regulation is controlled by the d[...]
-
Страница 30
26 3. Piping Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by [...]
-
Страница 31
27 Consistent gas pressure is essential at ALL gas connections. It is recommended that a 3/4-inch (19.05 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches (29.9 mb) of water column (W.C.) pres[...]
-
Страница 32
28 H. STEAM INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the steam plumbing installation is adequate and conforms with local and state regulations or codes. Care must be exercised when leveling steam dryers into final position. After leveling the dryer, check the downward pi[...]
-
Страница 33
29 a. The pressure of the condensate in the steam supply line will cause water hammer and subsequent heat exchanger (steam coil) failure. The steam supply connection into the main supply line must be made with a minimum 10-inch (25.4 cm) riser. This will prevent any condensate from draining towards the dryer. b. The steam supply line to the dryer m[...]
-
Страница 34
30 4. Steam Damper Air System Connections This dryer is manufactured with a pneumatic (piston) damper system, which requires an external supply of compressed air. The air connection is made to the steam damper solenoid valve, which is located at the rear inner top area of the dryer just in front of the electric service relay box. a. Air Requirement[...]
-
Страница 35
31 5. Steam Damper System Operation The steam damper, as shown in the illustration below , allows the coil to stay constantly charged eliminating repeated expansion and contraction. When the damper is opened, the air immediately passes through the already hot coil, providing instant heat to start the drying process. When the damper is closed, ambie[...]
-
Страница 36
32 6. Steam Damper Air Piston (Flow Control) Operation Adjustment Damper operation was tested and adjusted prior to shipping at 80 PSI (5.51 bars). If damper air adjustment is necessary, locate the flow control valve and make the necessary adjustments as noted below.[...]
-
Страница 37
33 I. PREP ARA TION FOR OPERA TION/ST AR T -UP The following items should be checked before attempting to operate the dryer: 1. Read ALL “ CAUTION ,” “ WARNING ,” and “ DIRECTION ” labels attached to the dryer. 2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label affixed to the left side p[...]
-
Страница 38
34 J. PREOPERA TIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions. 1. Turn on electric power to the dryer. 2. Refer t[...]
-
Страница 39
35 5. Make a complete operational check of ALL operating controls. NOTE: If computer program changes are required, refer to the computer programming section of the manual supplied with the dryer. 6. The dryer should be operated through one (1) complete cycle to assure that no further adjustments are necessary and that ALL components are functioning[...]
-
Страница 40
36 NOTES: 1. If the Anti-Wrinkle program is active, the light emitting diode (L.E.D.) display will continue to read “donE,” and the microprocessor controller (computer) will proceed through the Anti-Wrinkle program until the maximum “Active Guard Time” has expired or until the door i s opened, whichever comes first. The L.E.D. display will [...]
-
Страница 41
37 IMPORTANT: If the door is opened during a cycle, both the heat and motor will stop. However, the microprocessor controller (computer) will continue to count the time, either upward or downward, depending on which parameter is programmed. Continuation of the cycle will resume only after the door has been closed and any other of the three (3) temp[...]
-
Страница 42
38 NOTE: Pressing keyboard (touch pad) key “A”, “B”, “C”, “D”, and “F” will also start the dryer. The six (6) preprogrammed drying cycles “A” through “F” have been stored in the microprocessor controller (computer) memory. Refer to the Programming Manual supplied with the dryer for more specific operating instructions. N[...]
-
Страница 43
39 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If service is required, contact the reseller from whom the ADC equipment was purchased. If the reseller cannot be contacted or is unknown, contact the ADC Service Department for a reseller in your [...]
-
Страница 44
40 SECTION V W ARRANTY INFORMA TION A. RETURNING WARRANTY CARDS 1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass. These warranty cards are intended to serve the customer where we record the individual installation date and warranty information to better serve you should you file[...]
-
Страница 45
41 2. Each part must be tagged with the following information: a. Model number and serial number of the dryer from which part was removed. b. Nature of failure (be specific). c. Date of dryer installation. d. Date of part failure. e. Specify whether the part(s) being returned is for a replacement, a credit, or a refund. NOTE: If a part is marked fo[...]
-
Страница 46
42 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent [...]
-
Страница 47
43 STEAM DRYERS Clean the steam coil fins. We suggest using compressed air and a vacuum cleaner with brush attachment. WARNING: When cleaning steam coil fins, be careful not to bend the fins. If fins are bent, straighten by using a fin comb, which is available from local air conditioning supply houses. 90 DAYS Inspect and remove lint accumulation i[...]
-
Страница 48
44 D. LINT DRA WER REMOV AL To remove the lint drawer from the dryer pull drawer out approximately halfway. Rotate/move lint drawer stop hinge (refer to the illustration below ) downward and pull the drawer out. IMPORTANT: After replacing the lint drawer back into the dryer, be sure to rotate/move hinge back to the upward stop position.[...]
-
Страница 49
45 SECTION VII DA T A LABEL INFORMA TION A. DA T A LABEL Contact American Dryer Corporation When contacting American Dryer Corporation certain information is required to insure proper service/parts information from ADC . This information is on the data label affixed to the left side panel area behind the top control (access) door. When contacting A[...]
-
Страница 50
46 THE DATA LABEL 1. MODEL NUMBER The model number is an ADC number, which describes the size of the dryer and the type of heat (gas, electric, or steam). 2. SERIAL NUMBER The serial number allows ADC to gather information on your particular dryer. 3. MANUFACTURING CODE NUMBER The manufacturing code number is a number issued by ADC, which describes[...]
-
Страница 51
47 SECTION VIII REVERSING TIMER SPIN/DWELL ADJUSTMENTS Dual timer models with “reversing option” have an electric reversing timer in the electric service box, which is located in the upper rear area of the dryer. Both the dwell (stop) time and basket (tumbler) spin time are adjustable by mode selection switches located on the electronic timer ([...]
-
Страница 52
48 SECTION IX PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a. Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer. b. Start the drying cycle. c. Verify that the applicable indicator lights on the back side of the micropro[...]
-
Страница 53
49 2. For Heat Control Module Ignition Circuit a. For Models With Johnson Controls Direct Spark Ignition (DSI) Module (G760) Theory Of Operation: Start the drying cycle. When the gas burner ignites within the chosen trial for ignition time (6-seconds), the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open..[...]
-
Страница 54
50 F.S.S. In Action The exclusive Fire Suppression System (F.S.S.) will extinguish fires that may start in the drying basket (tumbler). A series of sensors positioned throughout the basket (tumbler) and interfaced with the microprocessor will trigger the F.S.S. water jets to quickly extinguish the flames. The water jets remain on for 2 minutes and [...]
-
Страница 55
51 BEFORE YOU START! CHECK LOCAL CODES AND PERMITS Call your local water company or the proper municipal authority for information regarding local codes. IMPORTANT: It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the plumbing installation is adequate and conforms to local, state, and federa[...]
-
Страница 56
52 2. Water Connections: The water connection is made to the 1/2” M.P.T. bushing of the electric water solenoid valve located at the rear upper left area of the dryer (see photo). The water solenoid valve has a 3/8” M.P.T. connection and a 1/2” bushing is supplied to provide the minimum 1/2-inch supply (feed) line. Flexible supply line/coupli[...]
-
Страница 57
53 OPTIONAL MANUAL BYPASS Provisions are made in the dryer fire suppression system (F.S.S.) for the installation of an optional manual bypass. Depending on the model dryer, the connections for the manual bypass are made at the “T” or “four way” fitting located in the outlet supply side of the water solenoid valve. The use and connections of[...]
-
Страница 58
54 3. Electrical Requirements No independent external power source or supply connection is necessary. The 24 volt power to operate the fire suppression system (F.S.S.) is accomplished internally in the dryer (from the dryer controls). WARNING: ELECTRICAL POWER MUST BE PROVIDED TO THE DRYER AT ALL TIMES. If the main electrical power supply to the dr[...]
-
Страница 59
55 F.S.S. (F ire Suppression System ) PAR T S BREAK DOWN Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the factory, you can FAX your order to ADC at (508) 678-9447 or telephone your order directly to the ADC Parts Department at (508) 678-9000. Please specify the dryer model number and [...]
-
Страница 60
56 Illus. No. Part No. Qty. Description 1 165114 1 F.S.S. Solenoid Valve 24V 50/60 HZ 2 143220 1 3/8” F.P.T. Brass Tee 3 143251 1 3/8” M.P.T. Brass Plug 4 143208 2 3/8” Comp x 3/8” M.P.T. Brass Connector 5 143099* 6' 3/8” OD x 0.035 Wall Copper Tubing 6 311588 1 Sprinkler Head Mounting Plate 7 143303 1 3/8” N.P.T. Brass Locknut 8 1[...]
-
Страница 61
57 Illus. No. Part No. Qty. Description 1 822752 1 F.S.S. Temperature Probe Assembly (includes illus. nos. 1 through 5) 2 154007 2 Push On Fastener 3 390390 1 Sensor Bracket (only) 4 150301 2 #8-18 Phillips PH TEK Screw 5 122647 1 Connector Only (does not include terminals)[...]
-
Страница 62
ADC 113370 1 - 03/25/02-25[...]