American Power Conversion AP9341 инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 24 страниц
- 0.57 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Power Supply
American Power Conversion MX28B-400
46 страниц 0.59 mb -
Power Supply
American Power Conversion SL-300TFX
27 страниц 0.73 mb -
Power Supply
American Power Conversion Vac 120
16 страниц 0.42 mb -
Power Supply
American Power Conversion 60kW InfraStruXureTM System
60 страниц 1.78 mb -
Power Supply
American Power Conversion SU24R2XLBP
16 страниц 0.66 mb -
Power Supply
American Power Conversion 2200VA 3U
25 страниц 0.48 mb -
Power Supply
American Power Conversion UPS
16 страниц 0.38 mb -
Power Supply
American Power Conversion 420
2 страниц 0.13 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации American Power Conversion AP9341. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции American Power Conversion AP9341 или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции American Power Conversion AP9341 можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций American Power Conversion AP9341, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции American Power Conversion AP9341 должна находится:
- информация относительно технических данных устройства American Power Conversion AP9341
- название производителя и год производства оборудования American Power Conversion AP9341
- правила обслуживания, настройки и ухода за оборудованием American Power Conversion AP9341
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск American Power Conversion AP9341 это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок American Power Conversion AP9341 и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта American Power Conversion, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания American Power Conversion AP9341, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства American Power Conversion AP9341, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции American Power Conversion AP9341. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
Inst allation and Quick Configuration T emperatur e/Humidit y Exp ansion Module AP9341[...]
-
Страница 2
This manual is available in English on the AP C W eb site (www .apc.com). Dieses Han dbuch ist in Deutsch au f der APC W ebseit e (www .apc.com) verfügbar . Ce manuel est disponible en français sur le s ite internet d’APC (www .apc.com). Questo manuale è dispon ibile in italiano sul sito web di APC (www .apc.com). 本マニュアル<各国 ?[...]
-
Страница 3
Content s Expansion Module i Preliminary Information . . . . . . . . . . . . . . . . . . . 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Additio nal options . . . . . . . . . . . . . . . . . . . 1 Addi tion al doc ume ntat ion . . . . . . . . . . . . . 1 Receiving in[...]
-
Страница 4
[...]
-
Страница 5
Tem perat ure /Hu mid ity M o dule 1 Preliminary Information Overview Connect the T emperature/Humidity Mod ule (TH Module) to the Environmen tal Manager Main Module to mon itor and co ntrol the environment through p eripheral devices, including temperature and humi dity sensor s and door contacts . Inventory Additional options • T empe ratu re S[...]
-
Страница 6
Preliminary Informati on 2 Temperat ure/Hum idity M odule Please re cycle The shipping materials ar e recyclable. Please save them for later use, or di spose of them appropr i ately .[...]
-
Страница 7
Tem perat ure /Hu mid ity M o dule 3 Front and R ear Panel Componen t s Front p anel Use the toolless mounting pegs on the front panel of the TH Modu le to install it in an APC rack o r enclosure without us ing any U-spaces. Rear panel T/ H Expa nsio n Modu le aem0 051a Item Descripti on 24 VDC Input Provides supplemen tal power for high-cu rre[...]
-
Страница 8
4 Temperat ure/Hum idity M odule Inst allation —TH Modu le Y ou can instal l the TH Module in the front or the rear of the rack or enclosur e, using either the rack- mount option, which uses 1 U of rack space, or the toolless peg -mount option, which u ses no U-space (the tool less peg- mount op tion is avail able only with APC racks and enclos u[...]
-
Страница 9
Installation —TH Module Tem perat ure /Hu mid ity M o dule 5 4. Insert caged nuts (prov ided with the rack) on the vertical mounting rails above a number at the top of a U-s pace in your rack and below the same num ber at the bottom of the U-space. 5. Align the mounting h oles of the brackets with the installed caged n uts, and insert fo ur mount[...]
-
Страница 10
6 Temperat ure/Hum idity M odule Inst allat ion—Access ories Sensors Sele cting a lo cation for the sen sor: Install the sensor in a location that represents the air to be m onitore d. A void placing t he senso r anywhere that may affect the s ensor reading , such as near windo ws, room entrances, air ducts, other heat sources, o r in direct sunl[...]
-
Страница 11
Installation— Accessories Tem perat ure /Hu mid ity M o dule 7 2. Thread a wire tie thro ugh the door holes, skipping one hole in the middle. If you have a te mperature/humi dity senso r , place the sensor in the middle of the wire tie, and pull the wire tie around a ridge on the sensor casing. If you have a temp erature sen sor , pull the wire t[...]
-
Страница 12
Installatio n—Accessories 8 Temperat ure/Hum idity M odule 7. W ith the door fully open, thread the sensor cords thro ugh the open ing in the fr ont post of the rack. 8. Route the cord s between the vertical supp ort rail and t he side panel . Each 13-ft (4-m) sen sor cord may b e extended t o a maximum of 50 ft (15 m), u sing RJ-4 5 coupling s a[...]
-
Страница 13
Installation— Accessories Tem perat ure /Hu mid ity M o dule 9 Alarm beaco n 1. Install the alarm beacon in a visible position either on the roof of the rack or inside the r ack. 2. If you install the beacon on the roof, route its cabl e thr oug h th e pro vide d ho les , as shown in the following illustration. 3. Plug the cable into the Alar m B[...]
-
Страница 14
Installatio n—Accessories 10 Temperat ure/Hum idity M odule Connecting TH Modules T o connect the Main Modu le to the TH Module: 1. Connect the fir st TH Module to either port marked A-Link on the rear of th e Main Module, using a s tandard CA T5 (or equivalent ) Ethernet pat ch cable (AP C part number 3 8 27BK-1 0 or eq uivalent). Do not use a c[...]
-
Страница 15
Installation— Accessories Tem perat ure /Hu mid ity M o dule 11 Setting unique identifi er numbers Each TH Modul e should h ave its own u nique identifier number , which is us ed in the Main Module’ s interface to identify and con figure this TH Module. Use the arrow button to the right of the Identifier # LED display to set a unique number fro[...]
-
Страница 16
Installatio n—Accessories 12 Temperat ure/Hum idity M odule Additional TH Modules Add TH Modules to the Main Module to monitor additional racks. The Main Module can support a maximum of 32 TH Modules (with addit ional power supp lies ). Adding power suppli es: T o avoid communication pro blems, connect the TH Module to the Main Modu le or a TH Mo[...]
-
Страница 17
Tem perat ure /Hu mid ity M o dule 13 Accessing a TH Module TH Module data autom atically appears on the interface of the Main Module to which it is connected. Upgrad ing a TH Module When you upgrade the fi rmware of t he Main Module, all TH Modules co nnected to it are also upgraded if a firmware upgrad e is available for them. Durin g the upgrade[...]
-
Страница 18
14 Temperat ure/Hum idity M odule S pecificatio ns TH Module Electrical Inp ut voltage, no mina l 24 VDC; 50–17 5 mA Maximu m total current draw 175 mA Physical Dimens ions (H × W × D) 1.74 × 13.25 × 1. 74 in (4.4 2 × 33.70 × 4 .42 cm ) W eight 1.50 lb (0.70 kg) Ship ping weight 4.00 l b (1.8 0 kg) Shippin g dimensio ns (H × W × D) 2.62 ?[...]
-
Страница 19
Specifi cations Tem perat ure /Hu mid ity M o dule 15 Sensors T emperature (AP93 35T) T e mperature acc uracy ± 3ºF (±2 ºC), from 32 to 104ºF ( 0 to 40ºC) Sens or ope rating temperature 14 to 15 9ºF ( –10 to 70 ºC) Maximu m le ngth of cable 50 ft (15.2 m) A-Link Maximum length o f cable 3280 ft (1000 m) Beacon Maximum length o f cable 330[...]
-
Страница 20
16 Temperat ure/Hum idity M odule Wa r r a n t y Limited warra nty APC warrants the T emperature/Humidity Module to be free fro m defects in materials and workmansh ip for a peri od of two years from th e date of purchas e. Its oblig ation under thi s warranty is limited to repairing or replacing, at its own so le option, any such de fective produc[...]
-
Страница 21
Warrant y Tem perat ure /Hu mid ity M o dule 17 4. Pack the unit car efully . The warranty does not cover damage sustained in transit. Enclos e a letter wi th your name, address, RMA number and daytime p hone number; a copy of the sales receipt; and a check as paymen t, if applicable. 5. Mark the RMA nu mber clearly on the o utside of the shipping [...]
-
Страница 22
18 Temperat ure/Hum idity M odule Life-Suppo rt Policy General policy American Power Con version ( APC ) does not recommend t he use of any o f its pro ducts in th e following situations : • In life-support applications where failure or malfunction of the APC product can be reasonably expected to cause failu re of the life-support device or to af[...]
-
Страница 23
Radio Frequen cy Interference Changes or modi fications to this unit not expressly appr oved by the party responsible for compliance could void the user’ s authority to operate this equipment . USA — FCC This equi pment has been tested and found to comp ly with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These[...]
-
Страница 24
*990-2380A-001* APC Worldwide Customer Support Customer s upport for this or an y other APC product is available at no char ge in any of the followin g ways: • V isit the APC W eb s ite to access docume nts in the APC Knowledg e Base and to su bmit custo mer suppo rt reque sts. – www .apc.com (Corporate Head quarters) Connect to localized APC W[...]