American Power Conversion BK600EI инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 40 страниц
- 0.29 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Power Supply
American Power Conversion 280, 420, 650
2 страниц 0.13 mb -
Power Supply
American Power Conversion AP7610
16 страниц 0.25 mb -
Power Supply
American Power Conversion 3000
60 страниц 1.37 mb -
Power Supply
American Power Conversion PD150L6F
84 страниц 1.97 mb -
Power Supply
American Power Conversion BI800T
18 страниц 0.71 mb -
Power Supply
American Power Conversion 5000RMB
23 страниц 0.76 mb -
Power Supply
American Power Conversion 120
16 страниц 0.16 mb -
Power Supply
American Power Conversion 5000VA
25 страниц 2.12 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации American Power Conversion BK600EI. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции American Power Conversion BK600EI или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции American Power Conversion BK600EI можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций American Power Conversion BK600EI, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции American Power Conversion BK600EI должна находится:
- информация относительно технических данных устройства American Power Conversion BK600EI
- название производителя и год производства оборудования American Power Conversion BK600EI
- правила обслуживания, настройки и ухода за оборудованием American Power Conversion BK600EI
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск American Power Conversion BK600EI это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок American Power Conversion BK600EI и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта American Power Conversion, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания American Power Conversion BK600EI, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства American Power Conversion BK600EI, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции American Power Conversion BK600EI. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
Models BK250EI, BK400EI, BK600EI 230 VA C User’ s Manual Uninterruptible Po w er Sour ce APC Back-UPS ®[...]
-
Страница 2
Important Safety Instructions! Please r Please r Please r Please r Please r ead this manual! ead this manual! ead this manual! ead this manual! ead this manual! V V V V V euillez lir euillez lir euillez lir euillez lir euillez lir e ce manuel! e ce manuel! e ce manuel! e ce manuel! e ce manuel! Bitte lesen Sie dieses Anleitungshandbuch! Bitte lesen[...]
-
Страница 3
Page 1 T able of Contents 1 . 0 Introduction ..................................................................... 2 2.0 Safety! ............................................................................. 4 Sécurité! (Françias) ..................................................................... 5 Sicherheit! (Deutsch) .......................[...]
-
Страница 4
Page 2 1.0 Intr oduction 1.1 Over view The UPS is a high performance standby uninterruptible power source designed to protect computers and peripheral devices such as monitors, modems, tape drives, etc. from utility line failures which could result in the loss or corruption of valuable data. In the event of a utility failure such as a blackout, bro[...]
-
Страница 5
Page 3 1.4 T est / Alarm Disable switch A dual function Test / Alarm Disable switch (400VA and 600VA models) allows you to check for proper operation by initiating a transfer to on-battery operation. This test ensures that the UPS is not overloaded and will support the system load during an actual power disturbance. By using the Test function throu[...]
-
Страница 6
Page 4 2.0 Safety ! Caution! ■ T o reduce the risk o f elec t ric s hoc k, d isc onnect the U ninterrupt ible P o w er Sourc e fro m the mains bef ore installing a comp u ter interfac e signal cable (w hen used). Reconnect the power c ord onl y after all signalling inte rc onnect ions have be en made. ■ Connect the U nint er ru p tible Po wer S[...]
-
Страница 7
Page 5 2.0 Sécurité ! Attention! ■ P o ur réd uir e le risque d’élect rocution, débr anc hez la prise pri nc ip ale de la s ource d’alimentation per manent e (U ninterru p tible P ow er Sour ce), av ant d’instal ler le câb l e d’inter face allant à l’or dinat eur (si utilisé). N e reb r anc hez le bloc d’alime ntation qu ’ap[...]
-
Страница 8
Page 6 2.0 Sicherheit ! V orsicht! ■ U m die Gefahr eines elektris chen Schlag es auf e in Minimum zu reduzieren, die unt e rbrec hung s fr e ie St rom ver sorgung v om Str omne tz t re nnen , b e vor gg f . ei n C omput er- Schnittst e l l ensig nalkabel ang es chlossen wi r d. Das N e tzkab el e rst nach Her st ellung al l er Signalverbind unge[...]
-
Страница 9
Page 7 2.0 ¡ Seguridad ! ¡Atencion! n P a ra red uc ir el riesgo de descarga eléctr ica, desconecte de la r e d la Fuente de ene rgía ininterr umpible antes de instalar el cable de s eñalizac ión de int e r faz de la comp utador a (si s e usa). V ue lv a a c onectar el co nductor flexible de alime ntac ión solamen te una ve z ef ectuadas t o[...]
-
Страница 10
Page 8 3.0 Installation 3.1 Receiving inspection Once the UPS has been removed from its shipping container, it should be inspected for damage that may have occurred while in transit. Immediately notify the carrier and place of purchase if any damage is found. Two output jumper cords are provided with the UPS. The packing materials are recyclable. S[...]
-
Страница 11
Page 9 ferroresonant type regulating transformers are not recommended. Use of a surge suppressor connected to the output of this UPS may unnecessarily load the UPS when on- battery. This UPS contains high performance surge suppression - additional suppression components are not required and are not recommended. If in doubt, please consult the equip[...]
-
Страница 12
Page 10 should be recharged before conducting the following Test for proper operation (section 3.7 ) and to ensure that the UPS will provide expected run time. The UPS may be used immediately upon receipt, but may not provide expected run time in the event of a utility failure. The battery will recharge to full capacity within 6 hours when the UPS [...]
-
Страница 13
Page 11 capacity of the UPS, don’t worry. The next section describes a test that you can perform to determine whether or not your equipment and the UPS are compatible, even if the computed power requirement of your equipment is 50% greater than the capacity of the UPS! 3.6.5 Once all power requirement figures have been converted to VA units and a[...]
-
Страница 14
Page 12 Note: Do not plug laser printers into this UPS! The power require- ments of a typical laser printer are much larger than the requirements of other computer peripherals and may trip the UPS’s rear panel circuit breaker. Plug laser printers into a quality surge suppressor. Remember that print jobs can be re-queued when the power is restored[...]
-
Страница 15
Page 13 Block diagram showing all major components of your UPS. 4.0 Principles of Operation Below is a block diagram showing the major components of your UPS. These blocks are described on the following pages, and are labelled accordingly. 4.1 4.1 4.1 4.1 4.1 4.2 4.2 4.2 4.2 4.2 4.3 4.3 4.3 4.3 4.3 4.4 4.4 4.4 4.4 4.4 4.5 4.5 4.5 4.5 4.5 4.6 4.6 4.[...]
-
Страница 16
Page 14 4.1 Noise and sur ge suppression The UPS contains high performance EMI/RFI (Electro-Magnetic and Radio Frequency Interference) noise and surge suppression circuitry to protect your computer equipment. The UPS provides this suppression continuously, whether or not it is turned on. Nor- mally, the UPS will continuously filter surges and elect[...]
-
Страница 17
Page 15 4.2 Load transfer switch The load transfer switch is actually an electro-dynamic relay which serves to rapidly transfer your computer equipment (load) from the utility to the UPS’s alternate power source in the event of a utility failure. When the utility is restored to within safe limits, the switch acts to re-transfer the load to the ut[...]
-
Страница 18
Page 16 4.6 T ransfor mer The UPS’s transformer is an electrical component which “steps up” the output voltage of the inverter to the normal utility line voltage. In addition, it serves to isolate the UPS from equipment failures. 4.7 Monitoring and contr ol electr onics This block is the “brain” of the UPS. The monitoring and control circ[...]
-
Страница 19
Page 17 Utility voltage sags are temporary amplitude reductions of the normal line voltage level. Utility voltage sags can be caused by local high power demand equipment such as elevators, air conditioners, shop tools and electric heaters. Brownouts, defined as long lasting utility voltage reductions, are sometimes initiated by the power company it[...]
-
Страница 20
Page 18 5.0 Contr ols and indicators 5.1 Power I/0 switch The power I/0 switch controls power to the UPS and its output receptacles. When the switch is on, the UPS operates and your computer equipment will be powered. When the switch is off, the UPS is de-energized and your equipment is unpowered. If your equipment switches are left on, the entire [...]
-
Страница 21
Page 19 sound a loud tone 2 minutes in advance of shut down due to battery capacity exhaustion. Once shut down, the UPS will return to the periodic beep. The UPS should be turned off at this point to cease the alarm. In the event the UPS encounters a severe overload, the UPS will shut down and emit a loud tone. The alarm is reset when the UPS is tu[...]
-
Страница 22
Page 20 Op t i o n Switch #2 Op t i o n Switch #3 Unde r volta g e Transfer Down (OFF) Down (OFF) 196 Vac Up (ON) Down (OFF) 184 Vac Down (OFF) Up (ON) 172 Vac Up (ON) Up (ON) 160 Vac 5.4.3 Option Switch #4 Option switch #4 sets the internal operating frequency of the inverter. It should be set to match the local line frequency. When in the down (o[...]
-
Страница 23
Page 21 6.0 UPS monitoring 6.1 Overview A UPS system alone provides excellent protection from brief power problems. However, during an extended power outage an unattended computer system will eventually shut down due to battery capacity exhaustion. To prevent data corruption when the UPS shuts down, the computer must be informed by the UPS of impen[...]
-
Страница 24
Page 22 6.3 Computer Inter face Por t (600 V A only) The computer interface port is diagramed below for your reference. Those with technical abilities wishing to use this port in a special application should be aware of the following limitations and capabilities of the interface. 6.4.1 Outputs at pins 3, 5 and 6 are actually open collector outputs [...]
-
Страница 25
Page 23 7.0 Difficulty Caution ! n This U ninterr uptible P ower Sourc e contains potentially hazardous v oltages. D o not at- temp t t o disass emble the unit. R e pairs are per for med only by fa ctor y traine d serv i ce per- s onnel. The unit contains no us er ser vicea ble parts ex cept for a re p laceable ba ttery . n This Unint er rup tible [...]
-
Страница 26
Page 24 7.0 Difficulté Attention ! ■ Cette so ur ce d’alimentat ion per mane n te (UPS) c ontient des c i rcuits haut e tension présentant un danger . N e jamais essay er de le démonter . Il n ’y a aucun c om p osant qui puisse être rép aré par l’utilisateu r . T ou tes les rép ar a tions doiv ent êt re effectuées par d u per - s o[...]
-
Страница 27
Page 25 7.0 Schwierigkeit V orsicht ! ■ Im I nne ren dieser unt erbrechungsf rei e n Strom ver s o r gung herrs c he n potenti e ll gefähr liche Spann un gen. N icht v er suche n, das Gerät zu öffnen . E s e nthält keine vom Ben ut z e r repa rie rba r en T e ile. Repa ra t u ren dür fen nur von aus geb ildetem K undendienstp ers onal durchg[...]
-
Страница 28
Page 26 7.0 Dificultad ¡Cuidado! ■ Esta F ue n t e de energía inint er rumpible c ontie ne ni ve les de v oltaje p e lig ro sos en p ote nci a. N o inten te desarmar la unidad, pues no contie ne piezas que puedan ser repa r adas por e l usuari o . Las reparaciones deb en efectuars e únicament e por pa rte d el personal de mant e nimie n t o ca[...]
-
Страница 29
Page 27 7.1 T r oubleshooting Chart PRO BLE M PO SSIB LE C AUSE ACTI O N TO TAK E U PS wil l no t tu rn on ( la m p wi thi n po wer I / 0 s wi tc h is n o t il lu mi na te d) , but beeps wh en power I / 0 s w it c h is on. 1. L ine cord plu g is lo os e. 1. Ch e ck fit of li n e c ord pl ug . 2 . R e ar p a ne l ci rc u i t br ea ke r i s tr ipped.[...]
-
Страница 30
Page 28 7.1 T roubleshooting Chart (continued) PRO BLE M PO SSIB LE C AUSE ACTI O N TO TAK E U P S emits l ou d ton e . P o wer I/ 0 swit ch is on but comp u ter equ ip m en t i s n ot p owe re d. U PS’ s r ea r p a n e l cir cui t b re ake r i s t ri ppe d ( b ut to n i s e xt e nd e d ) . N o r m a l u ti l it y v olt ag es are kn ow n t o be p[...]
-
Страница 31
Page 29 7.2 Replacing the Battery You can expect to receive 3 to 6 years of service life from the UPS's battery when installed in a cool, dry location. If you suspect the battery is weak, allow the UPS to charge the battery for at least 6 hours and perform the Test for proper operation described in section 3.7 . If after repeating the test you[...]
-
Страница 32
Page 30 7.3 Obtaining Service The troubleshooting chart in section 7.1 covers most of the difficulties that a user may encounter under conditions other than a failure of the UPS itself. For problems not covered in the chart, follow the below listed instructions. ■ See the tro ubleshooting char t and e liminat e the o bvious. A t ripped UPS circui[...]
-
Страница 33
Page 31 8.0 Storing the UPS 8.1 Storage Conditions The UPS should be covered and stored in an upright position, in a cool, dry location. The UPS should be stored with the battery in a fully charged state. This means that the UPS should be allowed to charge the battery for at least 6 hours before the UPS is switched off for storage. 8.2 Extended Sto[...]
-
Страница 34
Page 32 9.0 Run Time V ersus Load Load Mod el 250 Mo de l 40 0 Mo d e l 600 T ypica l com pute r l oa d 75 VA 29 min 72 min 105 min Typical mon och rome main frame termin a l 100 VA 23 min 47 min 79 min Sm a l l deskt o p sy stem wi t h 12" monitor 150 VA 14 min 30 min 54 min P oin t of sale sys te m ( cash r egi st ers) 200 VA 8 min 19 min 41[...]
-
Страница 35
Page 33 10.0 Specifications 10.1 Input Nominal input voltage: single phase 230 Vac. Nominal input frequency: 50 or 60 Hz, selected by option switch #4. 10.2 T ransfer Characteristics Frequency limits for on-line operation: ±5% of the nominal 50 or 60 Hz. Low input voltage limit for on-line operation: 196 Vac., may be set lower. 10.3 Output Charact[...]
-
Страница 36
Page 34 10.5 Sur ge and noise suppression Surge energy rating : 320 Joules (one time, 10/1000µs waveform). Surge current capability : 6500 Amp peak (one time, 8/20µs waveform). Surge response time : 0 ns (instantaneous) normal mode. Noise filter : full time EMI/RFI suppression, 100 kHz to 10 MHz. 10.6 Operating envir onment and physical dimension[...]
-
Страница 37
Page 35 Declaration of Conformity Application of Council Directives: 89/336/EEC,73/23/EEC,92/31/EEC, 93/68/EEC,91/157/EEC Standards to which conformity is declared: EN55022, EN50082-1, EN50091, EN60950 Manufacturer's Name and Address: American Power Conversion 132 Fairgrounds Road West Kingston, Rhode Island, 02892, USA -or- American Power Con[...]
-
Страница 38
Limited Warranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtai[...]
-
Страница 39
[...]
-
Страница 40
T oll free technical suppor t: Return shipment adr essess: Numér o ver t de l'assistance technique: Adr esse d'expédition des r envois: Númer o de telefono sin costo para Dir ecciones para devolver mercadería: apoyo técnico: U nited Stat es and Canada: 1-800-800-4272 Ireland: 1-800-702000 U .K. 0800-132990 Othe rs/A u t res/Otras: +1[...]