American Power Conversion SL-300TFX инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 27 страниц
- 0.73 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Power Supply
American Power Conversion SUTF3
17 страниц 1.1 mb -
Power Supply
American Power Conversion 480kW400V
32 страниц 3.5 mb -
Power Supply
American Power Conversion HS 500
4 страниц 1.66 mb -
Power Supply
American Power Conversion LVD300, LVD400, LVD500, LVD600, LVD1000
20 страниц 0.06 mb -
Power Supply
American Power Conversion 110Vac
16 страниц 0.42 mb -
Power Supply
American Power Conversion AP9825I
1 страниц 0.02 mb -
Power Supply
American Power Conversion 480kW 400V
72 страниц 4.97 mb -
Power Supply
American Power Conversion MX28B-PDF
15 страниц 0.33 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации American Power Conversion SL-300TFX. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции American Power Conversion SL-300TFX или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции American Power Conversion SL-300TFX можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций American Power Conversion SL-300TFX, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции American Power Conversion SL-300TFX должна находится:
- информация относительно технических данных устройства American Power Conversion SL-300TFX
- название производителя и год производства оборудования American Power Conversion SL-300TFX
- правила обслуживания, настройки и ухода за оборудованием American Power Conversion SL-300TFX
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск American Power Conversion SL-300TFX это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок American Power Conversion SL-300TFX и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта American Power Conversion, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания American Power Conversion SL-300TFX, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства American Power Conversion SL-300TFX, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции American Power Conversion SL-300TFX. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
990-1079, Rev ision 01 10/01 User’s Manual English APC Smart-UPS ® 1400VA XL 230VA C/120VAC /100VAC 3U Rack and Stack Uninterr uptible Pow er Supply[...]
-
Страница 2
TABLE OF CONT ENTS 1: Safet y Inform ation ............................................................................................................................................................ 1 Handling Saf ety ................................................................................................................ ..................[...]
-
Страница 3
[...]
-
Страница 4
[...]
-
Страница 5
1 1: S AF E T Y I NFORMA TION American Po w er Conversion Corpo ration (APC) is the leading national and international manufac- turer of state-of- the-art uninterru ptible power s upplies , redundant swit ches, power m anageme nt soft- ware, an d related equi pment. APC produ cts protect h ardwa re, software, an d data from th e threat of po wer di[...]
-
Страница 6
2 In order to maintain compliance with the EMC directive, output cords attached to the UPS should n ot exceed 10 meters in leng th. Pluggable equipment includes a protective earth condu ctor that carries the leakage curren t from the load devices (computer equipment). Total leakage current must not exceed 3.5 mA. D EENERGIZING S AFE TY [...]
-
Страница 7
3 2: I NST ALLA TION The UPS has a “rack and s tack” design that prov ides two moun ting options. The UPS can be mounte d in a 46.5 cm (19-in ch) equipmen t rack or st acked on a batte ry pack(s ) model SU24RMXLBP2U. Hard w are is provided for either option. U NPACKING Inspect the UPS upon receipt. A PC designed robus t packag ing for your prod[...]
-
Страница 8
4 S TACKI NG TH E UPS ON A B ATTERY P ACK Note: For rack m ounting, proceed to Mountin g the UP S in a Rack , below . Do not step o n the UPS. The UPS chassi s is not desig ned to sup- port additiona l weight. When stacking the UPS with an external battery pack, position the UPS on top of the 2U battery pack. The top of the battery pa ck has indent[...]
-
Страница 9
5 3. Attach the mounting brackets to the UPS before mounting the UPS in your rack, (below ). Each mounting bracket attaches to the UPS with four s crews (included). Two sets of bracket holes are located on the si des of the UPS. If you are us ing a four-post rack , attach the mounting brackets in the forward position. For two po st rack m ounting a[...]
-
Страница 10
6 2. Locate the battery cables tucked on top of the battery . 3. Locate the UPS battery connector jack to the right of the battery tray. 4. To connect the battery cable plug to the battery jack, push the plug into the jack firmly to ensure a tight connection. You will hear a “snap” when the connector is seated pro p- erly. 5. Tuck the w[...]
-
Страница 11
7 connection, loosen the screw and conn ect the surge su ppression devi ce ground lead. Tigh ten the screw to secure the lead. • 100V models : In order t o operat e at the fu ll VA rat ing of the 1400VA product , the su pplied 15A plug mu st be replaced w ith a 20A plug . This change mus t be done by qu alified service personnel. Refer to the web[...]
-
Страница 12
8 3: O PERA TION S MAR T -UP S F RONT P ANEL O PERATIO N The ON and OFF buttons are u sed to power th e UPS and act as master controls f or the connected equipment. Make sure connected equipment is switched to the ON p osition. The UPS remains on as long as it is attached to utility power. Power On Press and release the button to supply power t o t[...]
-
Страница 13
9 S ELF -T EST Automatic Self-Te st The UPS performs a self-test automatically when turn ed on, and every two we eks thereafter (by def ault). Refer to Us er Conf igur- able Items for details on changing the default interval. Automatic self-test eases maintenance requirements by eliminating the need for periodic m anual self-tes ts. During the self[...]
-
Страница 14
10 AVR Tr im This LED illuminates to indicate the UPS is compensating for a high utility voltage. AVR Boost This LED illuminates to indicate the UPS is compensating for a low utility voltage. B ATTERY P OWER If the utility power fails, the UPS can pro vide power to the connected equipment from its internal battery for a finite period. The UPS sound[...]
-
Страница 15
11 S MAR T -UPS R EA R P ANE L 230V m odels 120V/100V m odel s B ASIC C ONNE CTORS Serial Port Power management s oftware and interface k its can be used w ith the UPS. Use only int erface kits supplied or approved by AP C. If us ed, connect the interf ace cable to the 9-pin computer interface port. Secure the connector screw s to complete the conn[...]
-
Страница 16
12 D EFAULT S ETTI NGS Voltage Sensitivity The UPS d etec ts line vo ltage disto rtio ns (s uch a s spike s, not che s, dip s, and swells) as well as distortions caused by operation with inexpensive fuel-powered gen erators. By default, the UPS reacts to distortion s by transferring to on -battery operation to protect the con nected equipment. Wher[...]
-
Страница 17
13 O N B ATTERY O PERA TION The Smart-UPS switches to b attery operation automaticall y if the utility power fails. While running on-battery, an intern al alarm sounds (periodic beeps). Pre ss the button (front pane l) to silence the UPS alarm (for the curren t alarm only). You can change the au dible indicator if you are using the Powe rChute soft[...]
-
Страница 18
14 4: U SER C ONFIGU RA B LE I TEMS N OTE : S ETT ING T HESE IT E MS REQ UIR ES SO FT WAR E OR OP TIO NA L HA RDWA RE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automatic Self- Tes t Every 14 day s (336 hours ) Every 7 day s (168 hours ), On Startup Only, No Self-Test This function sets the interval at which the UPS will [...]
-
Страница 19
15 N OTE : S ETT ING T HESE IT E MS REQ UIR ES SO FT WAR E OR OP T IONA L HA RDWA RE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION High Transfer Point 230V models : 253VAC 120V models : 132VAC 100V models : 110VAC 230V models : 264, 271, 280VAC 120V models : 129, 135, 138VAC 100V models : 108, 112, 114VAC To avoid unn ecessa[...]
-
Страница 20
16 5: T RA NSP ORT ING Y OU R S MA RT -UPS Always DISCONNEC T THE B ATTERY before shipp ing in co mpliance with U.S. Departm ent of Transp ortation (DOT ) regulations . The battery m ay remain in the UPS; it does not have to be rem oved. D ISCONNECTING THE B ATTERY FOR T RANSPORT The battery is accessible f rom the fron t of the UPS. This proce- du[...]
-
Страница 21
17 6: S T OR A GE AND M AI N T E N AN C E S TORAG E S TORAGE C ONDITIONS Store the UPS covered and positioned as for proper functioning, in a cool, dr y location, with its bat- teries fully charged. Disconn ect any cables connected to th e computer interface port to av oid unnec- es s ary bat tery dr aina ge. E XTENDED S TORAG E At -15 t o +30 ° C[...]
-
Страница 22
18 R EPL ACING THE B ATTERY M ODULE 1. The plug on the new battery module i s taped to the side of the battery. Remove this tape allo wing the plug and the attached white cord and battery cables to come to the front of the battery. 2. Supporti ng the new battery modul e on th e bottom, alig n it with the bat- tery door open ing and slide it int o t[...]
-
Страница 23
19 7: T ROUBLESHOOTING Use the chart belo w to solve minor Smart-UPS installation and operation problems. Re fer to the APC web site, www.apc.com , for assistance with com p lex UPS problems. P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS WILL NOT TURN ON butto n not pus hed. Press t he butto n once to po wer the UPS an d the con nected equipm ent. U[...]
-
Страница 24
20 P ROBLEM AND P OSSIB LE C AU S E S OLUTION A LL LED S ARE OF F AND THE UPS IS PLUGGED IN TO A WA LL OUTLET The U P S is shut down and t he battery is discha rged from an extended o utage. None. The U PS will return t o norm al operatio n when the pow er is restored and the battery has a su fficient ch arge. T HE REPLACE BATT ERY LED IS LIT Weak [...]
-
Страница 25
21 S ERVICE If the UPS requires s er vice do not return it to the dealer. In st ead, follow these s teps : 1. Revi e w the problem s discussed in th e Troubleshooting secti on of this manual to eliminate com- mon probl e ms . 2. Verify that no circuit break ers are tripped. 3. If the problem persists, contact APC Customer Service through the APC we[...]
-
Страница 26
22 8: R EGULA TOR Y A ND W AR R AN TY I NFOR M A TION R EGULATORY A GE NCY A PPROVALS AND R ADIO F RE QUENCY W ARNINGS 230V MOD EL S This is a Class A pr oduc t. In a dom estic enviro n- ment this prod uct ma y cause ra dio interf erenc e, in which case the user may be re quired to take correc- tive ac tions. 120V MOD EL S 120V S TAN DARD C LASS A [...]
-
Страница 27
23 D ECLARATION OF C ONF ORM ITY L IMITED W ARRA NTY American Power Conversion (APC) warrants its products t o be free from defects in materia ls and workmanship for a period of two years from th e date of pu rcha se. Its ob ligat ion under t his warra nty is limi ted to repairin g or repla cing, at its own sole o p- tion, any such defect ive p rod[...]