Delta Electronics DNS SIP Series инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 20 страниц
- 0.55 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Power Supply
Delta Electronics S48SE
13 страниц 0.73 mb -
Power Supply
Delta Electronics Series V48SR
14 страниц 0.78 mb -
Power Supply
Delta Electronics HMU1045
1 страниц 0.18 mb -
Power Supply
Delta Electronics Suppression Inductors LFZ24H
1 страниц 0.13 mb -
Power Supply
Delta Electronics Power Factor Corrector PFC4116V Series
1 страниц 0.1 mb -
Power Supply
Delta Electronics Suppression Inductors LFO24V
1 страниц 0.19 mb -
Power Supply
Delta Electronics Ignition Coil IGT004
1 страниц 0.15 mb -
Power Supply
Delta Electronics SIR85
1 страниц 0.08 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации Delta Electronics DNS SIP Series. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции Delta Electronics DNS SIP Series или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции Delta Electronics DNS SIP Series можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций Delta Electronics DNS SIP Series, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции Delta Electronics DNS SIP Series должна находится:
- информация относительно технических данных устройства Delta Electronics DNS SIP Series
- название производителя и год производства оборудования Delta Electronics DNS SIP Series
- правила обслуживания, настройки и ухода за оборудованием Delta Electronics DNS SIP Series
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск Delta Electronics DNS SIP Series это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок Delta Electronics DNS SIP Series и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта Delta Electronics, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания Delta Electronics DNS SIP Series, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства Delta Electronics DNS SIP Series, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции Delta Electronics DNS SIP Series. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
Evaluation Procedure (DEP-008 A) The Delphi DNS Series of SIP type POL converters The DNS, 2.4~5.5V or 10~14V input, programmable output, non-isolated point of load DC/DC converters, are the latest of fering from one of the world’s largest power supply manufacturers ― Delta Electronics, Inc. The DNS converters have flexible and programmable tra[...]
-
Страница 2
2 3.0 Equipment Required 3.1 A DC Power Supply 0 - 20 V @ 0 - 20A (Agilent 6574A 0 -60V/0 - 35A or equivalent). 3.2 An oscilloscope (T ektronix TDS 3034 or equivalent) 4 Channel 300 MHz, equipped with a x1 scope probe, a x10 scope probe, and two BNC cables (length less than 20 inches/500mm) 3.3 Digital m ulti-meters, one with 20A range and ideally [...]
-
Страница 3
3 4.1 Connect one lead from the “+” lead of the DC source (S ee Item 3.1) to the “20A” terminal of the first multi-meter DVM1 (See Item 3.3). Then connect one lead from the “Common” of the DVM1 to the “Vin” pin of the Evaluation Board. DVM1 is used to measure the input current. 4.2 Connect one wire from the “-” lead of the DC so[...]
-
Страница 4
4 6.0 T est s Performed The following tests are p erformed at room temperature (+25 ℃ ). 6.1 Input Characteristics Input V oltage Range. Under-V oltage Lockout. No Load Input Current. 6.2 Output Characteristics Line Regulation. Load Regulation. Output Regulation. Output V oltage Set-point Programming Output V oltag[...]
-
Страница 5
5 5) SW2 is used to enable or disable the converter . For positive logic module, When SW2 is put in the ON p osition, the converter is ON and when SW2 is put in the OFF position, the converter is OFF . For negative logic module, When SW2 is put in the OFF position, the converter is ON, and when SW2 is put in the ON position, the converter is OFF . [...]
-
Страница 6
6 8.0 T est s and Evaluation 8.1 Input Characteristics 8.1.1 Input V olt age Range and Under-V olt age Lockout The DNS04xx Series of DC/DC converters will operate at full load from 2.4Vin to 5.5V in for 5Vin (nominal) types. The DNS12xx Series DC/ DC converters will operate at full load from 10Vin to 14V in for 12Vin (nominal) types. The converters[...]
-
Страница 7
7 8.2 Output Characteristics 8.2.1 Line Regulation Line Regulation Deviation is defined as the change in output volt age caused by varying the input voltage over a specified range while the ou tput load and temperature remain const ant. T est 1) T urn on the fan. 2) Set the output power to the desired operating point. 3) Set the switch SW2 to the c[...]
-
Страница 8
8 8.2.4 Output V olt age Set-point Programming (1) Output V olt age Set-Point Ad justment by external resistor Output V oltage Set-point Programming can be carried out by using the external program resistor connect between TRIM pin to ground to set output volt age set-point from 0.75Vdc to 5Vdc, the location can refer to the Evaluation Board Schema[...]
-
Страница 9
T able 2. Vo , s e t Rset (k Ω ) R33 Recommend Value, R//R 0.7525 Open Open 1.2 22.464 23.7k//432k 1.5 13.047 14.0k//191k 1.8 9.024 9.53k//169k 2.5 5.009 5.23k//118k 3.3 3.122 3.16k//261k 5.0 1.472 1.5k//78.7k T est 1. Put the resistor to program the desired output voltage set poin t by follow T able 1 and T able 2 for the standard output. 2. Set[...]
-
Страница 10
For DNS12xx series () 7525 . 0 0667 . 0 7 . 0 − × − = Vout Vtrim V For example, to program the output voltage of a DNS12 module to 3.3 Vdc, Vtrim is calculated as follows () 53 . 0 7525 . 0 3 . 3 0667 . 0 7 . 0 = − × − = Vtrim V T able 4. : V o,set adjustment range by use of external voltage source. Product Part Normal Output Set Voltage [...]
-
Страница 11
11 8.2.6 Voltage Tracking The DNS family was designed for applications that have output voltage t racking requirements during power-up and power-down. The devices hav e a TRACK pin to implement three types of tracking method: sequential, ratio-metric and simultaneous. TRACK simplifies the task of supply voltage tracking in a power system by enablin[...]
-
Страница 12
12 Figure 4: Sequential Power up Figure 5: Sequential Power down Ratio-Metric Implementation Ratio–metric is implemented by the selection of the resistor values of the voltage divider on the TRACK pin. Resistors R1 and R2, in Figure 6 determine the tracking met hod that is implemented. To simplify the tracking design, set initial value of R2 equa[...]
-
Страница 13
For Ratio-Metric applications that need the PS1 and PS2 outputs arrive regulation set point at same time, use equation 1 to calculate R1, set △ V=Vo set,PS1 –Vo set,PS2 and △ V will be negative. The waveforms of power up and down are showed in Figures 7 and 8. K Vref Vref V Vo R PS set 20 * ] ) [( 1 2 , − ∆ + = Ω -----------------------[...]
-
Страница 14
14 For example, the PS1 Vo set,PS1 =5V, the PS2 Vo set,PS2 =3.3V, R1 is calculated as follows: K K R 303 . 10 20 * 32 . 1 ] 32 . 1 ) 3 . 1 3 . 3 [( 1 = − − = Ω Figure 9. Ratio–metric tra cking Power up Figure 10. Ratio–metric tracking Power down Simultaneous Implementation Similar to the ratio-metric implementation, simu ltaneous tracking[...]
-
Страница 15
15 For type C (DNXXX0A0XXXX C ), th e simultaneous tracking can be accomplished by putting R1 equal to 30.1K Ω through Vo PS1 to the TRACK pin of PS2. Figure 12 shows the circuit diagram of Simultaneous start-up when Vo PS2 tracks the Vo PS1 (only for type C). R1 R2 TRACK Vo PS1 PS2 Vo PS2 PS1 Vin Vin ENABLE ENABLE To Tracking circuit 20K 30.1K Fi[...]
-
Страница 16
16 Notes on the use of Track function: 1. For proper voltage tracking, first, The ENABLE On/Off pin of the PS2 module is lef t unconnected (or tied to GND for negative logic modules or tied to VIN for positive logic modules), so that the modules are ON by default and second applied input voltage to the PS1 and PS2. The TRACK pin is held at ground p[...]
-
Страница 17
T est 1) T urn on the fan. 2) Adjust the input voltage to the desired operating point. 3) Set the electronic or resistive load at 50% of maximum load. 4) Change channel 1 to scope probe and measure across the dynamic R . 5) Set the switch SW2 to the converter ON. 6) Set channel 2 on the oscillo scope to be AC coupled and to 50mV/Div and for 5mS/Div[...]
-
Страница 18
5. Set channel 2 on the oscilloscope to be DC coupled and to the appropriate range for the output voltage. 6. Connect a coaxial cable from channel 2 to BNC2 on the Evaluation Board. 7. Set the T ime base to 2mS/Div 8. Set the T rigger for a one-time event and set the T rigger level at approximately 2V (rising) or suitable tr igger point (referring [...]
-
Страница 19
Appendix A- Evaluation Board Schematic 19[...]
-
Страница 20
Appendix B - Evaluation Board Layout (Top View) Appendix C - Evaluation Board Layout (Bottom View) CONTACT DATA: www. delt aww.c om USA: Telephone: East Coast: (888) 335 8201 West Coast: (888) 335 8208 Fax: (978) 656 3964 Email: DCDC@delta-corp.com Europe: Telephone: France: +33 1 6485 1212 Germany: +49 89 370 62 897 UK: +44 777 195 6299 Fax: +33 1[...]