Hearth and Home Technologies QV36D инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 36 страниц
- 1.23 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Indoor Fireplace
Hearth and Home Technologies CFL-18LP-C
28 страниц 1.31 mb -
Indoor Fireplace
Hearth and Home Technologies CFL-24NG-C
28 страниц 1.31 mb -
Indoor Fireplace
Hearth and Home Technologies RBV4842IH
48 страниц 4.96 mb -
Indoor Fireplace
Hearth and Home Technologies GDST5244I
60 страниц 5.72 mb -
Indoor Fireplace
Hearth and Home Technologies SL-350TRS-IPI
85 страниц 7.52 mb -
Indoor Fireplace
Hearth and Home Technologies 839-1320
56 страниц 2.94 mb -
Indoor Fireplace
Hearth and Home Technologies FB-IN-S
44 страниц 2.47 mb -
Indoor Fireplace
Hearth and Home Technologies 6000G-LP
74 страниц 3.6 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации Hearth and Home Technologies QV36D. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции Hearth and Home Technologies QV36D или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции Hearth and Home Technologies QV36D можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций Hearth and Home Technologies QV36D, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции Hearth and Home Technologies QV36D должна находится:
- информация относительно технических данных устройства Hearth and Home Technologies QV36D
- название производителя и год производства оборудования Hearth and Home Technologies QV36D
- правила обслуживания, настройки и ухода за оборудованием Hearth and Home Technologies QV36D
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск Hearth and Home Technologies QV36D это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок Hearth and Home Technologies QV36D и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта Hearth and Home Technologies, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания Hearth and Home Technologies QV36D, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства Hearth and Home Technologies QV36D, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции Hearth and Home Technologies QV36D. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
1 - Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. - What to do if you smell gas • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow t[...]
-
Страница 2
2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or components MA Y BE USED . This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas ap[...]
-
Страница 3
3 TABLE OF CONTENTS Safety and Warning Information ............................................... 2 Service Parts List ...................................................................... 4 Section 1: Approvals and Codes .............................................. 6 Appliance Certification .....................................................[...]
-
Страница 4
4 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. 5 4 2 1 3 7 Log Set Assembly 15 11 10 12 8 9 14 13 6 18 16 19 17 (NG , LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces Service Parts QV36D Beginning M anufacturing Date: 4-02 Ending M anufacturing Date: ______ u[...]
-
Страница 5
5 S ervice Parts List / Liste des pièces de rechange ITEM / P IÈCE COMMON PARTS / PIÈCES COMMUNES PA RT NUMBER / N° DE PIÈCE ON/OFF Rocker Switch / Int errupteur à bascule marche/arrêt 060-511 Pie zo Ignitor / Allumage Piézo 291-513 Tu be Assembl y / Module de tube 477-301A 1 Burner Orifice T op NG (#36C) / Orifice de brûleur GN (#36C) 582[...]
-
Страница 6
6 Appliance Certification The fireplace model discussed in this Installers Guide has been tested to certification standards and listed by the applicable laboratories. Certification MODEL: QV36D LABOR ATORY: Underwriters Laboratories TYPE: Direct Vent Gas Fireplace STANDARD: ANSI Z21.88-2000·CSA2.33-M00·UL307B Installation Codes The fireplace inst[...]
-
Страница 7
7 Introducing the Quadra-Fire Gas Fireplace Quadra-Fire direct vent gas fireplaces are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. The information contained in this Installers Guide , unless noted otherwise, applies to all models and gas control sys- tems. Gas fi[...]
-
Страница 8
8 Figure 1. Diagram of the QV36D 41 1/8 [1044mm] 38 [965mm] 36 1/8 [916mm] 25 1/4 [642mm] 34 5/8 [879mm] 8 5/8 [219mm] VENT COLLARS ELECTRICAL ACCESS 26 7/8 [682mm] 12 3/4 [323mm] 3 1/2 [90mm] GAS LINE ACCESS 2 1/8 [55mm] 6 7/8 [174mm] 14 1/4 [362mm] 8 5/8 [219mm] VENT COLLARS 21 1/2 [548mm] 11 5/8 [297mm] 28 1/2 [724mm] TOP S TANDOFFS HOOD TRIM DO[...]
-
Страница 9
9 Installing the Fireplace Step 1. Locating the Fireplace For space and clearance requirements for locating a fire- place within a room see Figure 2. ABCD E 42” 22” 36” 51” 72” For minimum clearances, see the direct vent termination clearance diagrams on pages 24 and 25 in this manual. Minimum Clearances from the Vent Pipe to Combustible [...]
-
Страница 10
10 Framing should be constructed of 2 X 4 lumber or heavie r. A . ............. 42”* B . ......... 38 1/2” C . ............... 22” D . ............... 42” E . ......... 27 7/8” Figure 3. Framing Dimensions Step 2. Framing the Fireplace Fireplace framing can be built before or after the fireplace is set in place. Framing should be position[...]
-
Страница 11
11 NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOIN T. Figure 4. D-Series Direct Vent Component Specifications (5-inch inner pipe / 8 5/8-inch outer pipe) DV-36D 5 3/4” (146mm) 8 3/4” (222mm) 11 3/4” (298mm) DV-48D 7 3/8” (187mm) 6 5/32” (156mm) 11 5/8” (295mm) 8 5/8” (220mm) 8 1/2” (216mm) 6 7/16” (164mm) 11 1/16” (281mm[...]
-
Страница 12
12 Figure 5. Vent System Components and Termination Kits Step 3. Installing the Vent System A. Vent System Approvals This model is approved to use D-series direct vent pipe components and terminations (see Figures 4 and 5). Ap- proved vent system components are labeled for identifica- tion. This pipe is tested and listed as an approved compo- nent [...]
-
Страница 13
13 Figure 6. Straight Up Vertical Venting STRAIGHT UP VERTICAL VENTING V (FT .) 40' MAX. (12.4 M) CAP V Flue Restrictor Instructions 1. Remove Exhaust Shield using a 1/4” nut driver by removing the four screws securing it in place (see Figure 7). Figure 8. Flue Restrictor BREAK HERE Figure 7 EXHAUST SHIELD FLUE RESTRICTOR 2. Break the Flue R[...]
-
Страница 14
14 HORIZON TAL VENTING Kit No. H Max. Run DVK-01TRD 24" (610 mm) Figure 10. Corner Installation NOTE: T his model is tested and approved to use 45 ° elbows in corner installations. Howeve r , 90 ° elbows will result in better performance. 45-DEGREE ELBOW 90-DEGREE ELBOWS H 3. Match the amount of vertical you have in the sys- tem with the cha[...]
-
Страница 15
15 Figure 12. Venting with One 90° Elbow NOTE: If a 90 o elbow is first attached to the unit, the maximum horizontal run is 3-feet (914mm). VENTING WITH ONE (1) 90° ELBOW V (F T .) H (F T .) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' [...]
-
Страница 16
16 VENTING WITH TWO (2) 90 o ELBOWS V FT . H + H 1 (FT .) 1' MIN. ( 305mm) 5´ MAX. (1.52 m ) 2' MIN. (610mm) 10´ MAX. (3.1 m ) 3' MIN. (914mm) 15´ MAX. (4.65 m ) 4' MIN. (1.22m) 20´ MAX. (6.2 m ) V+H+H 1 = 40' MAX.(12.4m) H+H 1 = 20´ MAX. (6.2 m ) V+V 1 +H = 40' MAX.(12.4m) Figure 14. Venting with Two 90° Elbows [...]
-
Страница 17
17 Figure 15. Venting with three 90° elbows VENTING WITH THREE (3) 90° ELBOWS 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX. (1.86m) 15´MAX. (4.65m) 4´MIN. (1.22m) 8´MAX. (2.48m) 20´MAX. (6.2m) V+H+H 1 +H 2 = 40 ´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H 1 +H 2 = 20´ MA[...]
-
Страница 18
18 VENTING WITH THREE (3) 90° ELBOWS V (F T .) H (F T .) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) NOTE: H + H 1 = 20' MAX. (6.2m) V + V 1 + H + H 1 = 40' MAX. (12.4m) V (F T .) H + H 1 (F T .) 1' MIN. (305m[...]
-
Страница 19
19 Figure 17 B. Inst alling V ent Component s After determining which set of starting collars will be used (top or rear), follow venting instructions accordingly . V enting Out the Rear V ent Remove the installed rear seal cap from the rear starting collars by cutting the strap at each end. (see Figure 17). Follow the vent configuration tables acco[...]
-
Страница 20
20 2. Continue Adding V ent Component s W ARNING: INST ALLA TION OF THIS FIRE- PLACE REQUIRES THE USE OF A HEA T SHIELD ABOVE THE FIRST 90 0 ELBOW IN THE VENTING SYSTEM. Figure 19 T o Install the Heat Shield: 1. Determine if the heat shield is required. Do so by mea- suring the vertical distance between the top horizontal surface of the elbow to an[...]
-
Страница 21
21 For Vertical Runs - The vent system must be supported every eight (8) feet (2.4m) above the fireplace flue outlet by wall brackets. To install support brackets for vertical runs: • Attach wall brackets to the vent pipe and secure the wall bracket to the framing members with nails or screws. Figure 23. Installing Support Brackets 4. Install Fir[...]
-
Страница 22
22 For Vertical Runs - One ceiling firestop is REQUIRED at the hole in each ceiling through which the vent passes. To install firestops for vertical runs that pass through ceilings: • Position a plumb bob directly over the center of the verti- cal vent component. • Mark the ceiling to establish the centerpoint of the vent. • Drill a hole or d[...]
-
Страница 23
23 ! C. Vent Termination For Horizontal Terminations - To attach and secure the termination to the last section of horizontal vent: • Rotate and interlock the ends as described at the begin- ning of the Installing Vent Components section. • The termination kit should pass through the wall firestops from the exterior of the building. • Adjust [...]
-
Страница 24
24 ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ V = VENT TERMINAL X = AIR SUPP LY INLET = AREA WHERE TERMINAL I[...]
-
Страница 25
25 For Vertical Terminations - To locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint. • Make the outline of the roof hole around the centerpoint nail. • The size of the roof hole framing dimensions depend on the pitch of the roof. There M[...]
-
Страница 26
26 Step 4. Positioning, Leveling, and Securing the Fireplace • Place the fireplace into position. • Level the fireplace from side to side and from front to back. • Shim the fireplace with non-combustible material, such as sheet metal, as necessar y. • Secure the fireplace to the framing by nailing or screwing . ! ! The diagram below shows h[...]
-
Страница 27
27 Figure 34. Gas Supply Line • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing. • At the gas line access hole the gap between the supply piping and gas access hole can be plugged with non- combustible insulation to prevent cold air infiltration. Step 6. T[...]
-
Страница 28
28 Step 8. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENT AL FIREPLACE OPERA TION. • This appliance DOES NOT require 110-120 VAC to operate. WARNING: DO NOT CONNECT 1 10-120 V AC T O THE GAS CONTROL V [...]
-
Страница 29
29 Step 9. Finishing Figure 37 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 2 and 3 for other fireplace clearances. Only non-combustible materials may be used to cover the black fireplace front. W ARNING: WHEN F[...]
-
Страница 30
30 Installing the Trim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face. The joints between the finished wall and the fireplace top and sides can only be sealed with a 300° F . (149° C) minimum sealant. WA RNING: WHEN FINISHING THE FIRE[...]
-
Страница 31
31 Step 11. Lighting the Appliance STANDING PILOT IGNITION A. This appliance (standing pilot version) has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactl y. B. BEFORE LIGHTING smell all around the appli- ance area for gas. Be sure to smell next to the floor because some gas is heavier than air and wil[...]
-
Страница 32
32 Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace. Review safety warnings and cautions • Read the Safety and Warning Information section at the beginning of this Installers Guide . Double-check for gas leaks • Before lighting the fireplace, do[...]
-
Страница 33
33 Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season. See the table below for specific guidelines re[...]
-
Страница 34
34 Troubleshooting W ith proper installation, operation, and maintenance your gas fireplace will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by [...]
-
Страница 35
35 Symptom Possible Cause Corrective Action 3. (Co nt inued) f. H ig h l imit switc h is defecti ve or has reached its ma x im um temperature. A llow the un i t to cool. I f the burner remains lit after the fireplace warms up, the sw i tch is good. 4. Frequent pilot outage problem. a. Pilot flame ma y be too high or too lo w , or blowi ng (high), c[...]
-
Страница 36
36 Lifetime Warranty LIMITED LIFETIME WARRANTY The Hearth & Home T echnologies limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home T echnologies will repair or replace them. These items include but are not limited to steel and cast iron components, all gas b[...]