Lennox Hearth Products Brentwood SP инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 24 страниц
- 1.79 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Indoor Fireplace
Lennox Hearth Products 36" and 42" Wood Burning Fireplaces BC-36/42
8 страниц 0.21 mb -
Indoor Fireplace
Lennox Hearth Products Leveling Leg Field Fix Kit MPE-27
1 страниц 0.56 mb -
Indoor Fireplace
Lennox Hearth Products MONTECITO ESTATE MONTEST
24 страниц 1.47 mb -
Indoor Fireplace
Lennox Hearth Products Direct Vent MPD-33 Series
32 страниц 2 mb -
Indoor Fireplace
Lennox Hearth Products B-ENC0353VDE
24 страниц 3.91 mb -
Indoor Fireplace
Lennox Hearth Products Merit Series LV-42REN
20 страниц 3.05 mb -
Indoor Fireplace
Lennox Hearth Products Merit CPF-38
8 страниц 0.1 mb -
Indoor Fireplace
Lennox Hearth Products LMDTV-3328CNM
28 страниц 2.16 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации Lennox Hearth Products Brentwood SP. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции Lennox Hearth Products Brentwood SP или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции Lennox Hearth Products Brentwood SP можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций Lennox Hearth Products Brentwood SP, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции Lennox Hearth Products Brentwood SP должна находится:
- информация относительно технических данных устройства Lennox Hearth Products Brentwood SP
- название производителя и год производства оборудования Lennox Hearth Products Brentwood SP
- правила обслуживания, настройки и ухода за оборудованием Lennox Hearth Products Brentwood SP
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск Lennox Hearth Products Brentwood SP это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок Lennox Hearth Products Brentwood SP и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта Lennox Hearth Products, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания Lennox Hearth Products Brentwood SP, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства Lennox Hearth Products Brentwood SP, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции Lennox Hearth Products Brentwood SP. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
EP A W ood -Bu rni ng Fir epl ace s P/N 8 50, 039 M REV . G 1 1/2 008 BRENTWOOD SP MODEL BRENTWOOD™ This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation. Do not alter or modify the fireplace or [...]
-
Страница 2
W ARNING T o avoid the risk of damaging fireplace materials and increas- ing the risk of fire, do not use the fireplace to cook or warm food. IMPORT ANT! GENERAL SAFETY PRECAUTIONS. READ AND UNDERST AND THESE SAFETY R U L E S B E F O R E Y O U R F I R S T F I R E . IMPOR T ANT Wh en b urn in g wo od , us e SO LI D NA TU RAL DR Y WE LL -SE AS ONE[...]
-
Страница 3
T ABLE OF CONTENTS Safety Rules and Specifications for Mobile or Manufactured Home Installation ......................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment ........................... Page 3 Operating The Fireplace .................... Page 3[...]
-
Страница 4
Building a Fire (starting and maintaining a fire) T o start a fire, place several crumpled up balls of newspa per in the firebox. Place small dry pieces of kindling on top of the paper , criss-crossing the kindling so that there are air spaces in be- tween. Keep the fuel far back enough so that air can get underneath. Open the air controls fully[...]
-
Страница 5
B. Blowers operating (e.g.: range hood) These blowers draw air out of the house and may actually cause a negative pressure in the house. T urn off all blowers and open a nearby window to determine if this is the cause of the problem. C. Wet wood W et or tarred wood will smoulder and smoke instead of burn properly . D. Dirty or blocked chimney Check[...]
-
Страница 6
REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractor y . These cracks can be minimized by proper curing as described in “First Fires”. They will not normally dimin- ish the effectiveness of the refractor y . If large cracks develop, then the refractor y should be replaced. T o replace the ref[...]
-
Страница 7
GLASS CARE Glass Replacement The glass used for the Brentwood™ fireplace is a high temperature ceramic glass (1,400° F). If the glass breaks, it must be replaced with an identical ceramic glass. T empered glass or ordinary glass will not withstand the high temperatures of the Brentwood fireplace. Replacement glass should be purchased from a Le[...]
-
Страница 8
Framing, Facing And Mantel The construction of the framing, facing, and mantel must be in accordance with the stan- dards and the following illustrations ( Figure s 7a, 7b and 8 ): A. Frame the fireplace using 2” x 3” or heavier lumber . B. WARNING: Combustible materials cannot be used in the space directly above the fireplace, except for the[...]
-
Страница 9
C om b u s ti b l e ma t er i a ls c a n N O T be us e d i n t he s p ac e di re c tl y ab ov e t h e fi re p la c e . D o n ot fi l l t h e sp a ce a bo ve th e fir ep l ac e wi th an y m at e r i al ( Ex ce p t t h e wo o d f r am in g ) F 19 -3 /3 2” J 20-1/2” E 7’ Min. 2” x 3’ Min. D Fireplace Framing Header B A OUTSIDE CHASE G H C[...]
-
Страница 10
Facing 1. Combustible material must be installed flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fireplace) ( Figure 10 ) . 2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fireplace facing ( Figure 11 ) . Mantel The mantel must be[...]
-
Страница 11
HOT AIR DUCTING INST ALLA TION The Brentwood™ fireplace is approved for use with a Gravity Kit. Gravity Kit The gravity kit is designed for double hot air out- lets and includes: (See Figures 12 and 13 ) - 2 telescopic lengths 8” I.D. - 2 90º elbows 8” I.D. - 2 hot air outlet kits (grill and frames) - 2 adaptors See Gravity Kit Accessories [...]
-
Страница 12
6- 1/2 ” Mi n. (t o c ei li ng) Figure 13 Figure 14 Flashing Collar Rain Cap Roof Support Attic Radiation Shield Radiation Shield (Firestop) Non-Combustible Facing Maintain at least 6-1/2” (160 mm) clearance from the outlet grill framing to a combustible ceiling, side wall or mantel. Ou tle t Gri ll Ou tle t Gri ll WARNING: The outlet grills sh[...]
-
Страница 13
The duct system must be installed respecting the following: 1. Remo ve the plat es clo sing up the 8” dia. hol es on top of the fireplace. Then, cut the insula- tion in order to obtain two 8” dia. openings. Fix the adaptors on the fireplace openings by turning clockwise ( Figure 12 ) . 2. Maintain at least a 2” (50 mm) clearance between the[...]
-
Страница 14
6. The chimney must extend at least three (3) feet (915 mm) above its point of contact with the roof and at least two (2) feet (610 mm) higher than any wall, roof or building within ten (10) feet (3m) of it ( Figure 17 ) . 7. If the chimney extends higher than five (5) feet (1,500 mm) above its point of contact with the roof, it must be secured us[...]
-
Страница 15
CHIMNEY INST ALLA TION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 18 ). Use a plumb-bob to line up the center of the holes. The sizes are indicated in T able 2 for the floor and ceiling holes and T able 3 ( Page 13 ) for the roof holes. 2. From below , install a firestop in ea[...]
-
Страница 16
Roof Down Slope Hole Size S LO P E A SH T / H T 6 1 03 + S -2 1 0 0 + / H T6 0 0 0 + A C R oo f P it c h 6 ” 6 ” 6 ” 0 * 1 2- 3 / 8 ” ( 3 1 4 m m ) 1 4- 1 / 8 ” ( 3 5 9 m m ) 1 5” ( 38 0 m m) 2 /1 2 1 2- 9 / 1 6” ( 3 19 m m ) 1 4- 3 / 8 ” ( 3 6 5 m m ) 1 5 3 / 8 ” ( 3 9 0 m m ) 4 /1 2 1 3” ( 3 30 m m ) 1 4 -7 / 8 ” ( 3 7 8 m m[...]
-
Страница 17
Ch imn ey 6” Elbo w Offset & Height One Length Between Elbows T wo Lengths Between Elbows 8” 12” 18” 24” 36” 48” 8” & 48” 1 2” & 4 8” 1 8 ” & 48 ” 2 4” & 4 8 ” 36” & 48” 48” & 48” Se cu re T emp AS HT No va T emp HT 61 03 + 15º A 3- 5/ 16 ” (8 4m m) 4- 5/ 16 ” (1 10 mm) 5- 7/ 8?[...]
-
Страница 18
ANGLED WALL RADIA TION SHIELD (RSM+ and RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Note: 45º angle for Canada only ( RSMI45) In cold climate locations (climates where temperatures will fall below 32° F / 0° C), we recom[...]
-
Страница 19
CHIMNEY SUPPORT INST ALLA TION Universal Roof Support This support has three possible uses: 1. For ASHT / HT6103+ and S-2100+ / HT6000+, it must be used on a roof to support the chimney . 2. It may be used on a floor , ceiling or roof above an offset to support the chimney above the offset. 3. It may be used on a floor , ceiling or roof as a supp[...]
-
Страница 20
Follow these steps: 1- Position the fireplace in its location. T emporarily install the ASHT elbow on the top of the fireplace and, using a level, mark with an oval the location where the flue liner will enter the masonry chimney . 2- In the middle of the oval, drill a hole in the masonr y chimney at 30º. 3- Increase the size of the hole until [...]
-
Страница 21
Installation Accessories Description Cat./Part No. (Required - Order Separately) Black Cast Iron Door for Brentwood ™, BWBK H0516 Gold Plated Cast Iron Door for Brentwood, BWG H0517 Brushed Nickel Cast Door for Brentwood, BWBN H4849 Outside Air Kit (Required - Included With Fireplace) Outside Air Coupler to connect outside air UZI to fireplace, [...]
-
Страница 22
(AC) Air -Cooled Chimney System* 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior AC Starter Adaptors One of the following adaptors is required if installing an AC chimney system * AC Ch im ne y is N OT r ec om me nd ed a t el ev at io ns ab ov e 4 ,0 00 fe et o r in co ld c li ma te s ( cl im at es w he re t [...]
-
Страница 23
CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation: Side wall: 17” (324 mm) measured from the fireplace side. Ceiling: 6’ 8” (2,032 mm) measured from the base of the fireplace. Fireplace enclosure: Bottom : 0” Side: 0” to spacer Back: 0” to spacer T op: Do not fill the space above[...]
-
Страница 24
Printed in Canada © 2006 Lennox Hearth Products P/N 850,039M REV . G 11/2008 24 Y our Fireplace's Model Number ________________________________________ Y our Fireplace's Serial Number ________________________________________ The Date On Which Y our Fireplace Was Installed ___________________________ Y our Dealer's Name _____________[...]