Louisville Tin and Stove 90N50A инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 19 страниц
- 0.26 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Furnace
Louisville Tin and Stove CF654C-R
28 страниц 0.33 mb -
Furnace
Louisville Tin and Stove W356F
20 страниц 0.23 mb -
Furnace
Louisville Tin and Stove DVCF558B-R
22 страниц 0.28 mb -
Furnace
Louisville Tin and Stove HEDV254A
2 страниц 0.18 mb -
Furnace
Louisville Tin and Stove 000 BTU
2 страниц 0.24 mb -
Furnace
Louisville Tin and Stove cdv336b
2 страниц 0.02 mb -
Furnace
Louisville Tin and Stove DVCF404B-R
22 страниц 0.28 mb -
Furnace
Louisville Tin and Stove CF353C-H, CF503C-H, CF653C-H, CF354C-H, CF504C-H, CF654C-H, CF357C-H, CF557C-H, CF358C-H, CF558C-H
27 страниц 0.47 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации Louisville Tin and Stove 90N50A. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции Louisville Tin and Stove 90N50A или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции Louisville Tin and Stove 90N50A можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций Louisville Tin and Stove 90N50A, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции Louisville Tin and Stove 90N50A должна находится:
- информация относительно технических данных устройства Louisville Tin and Stove 90N50A
- название производителя и год производства оборудования Louisville Tin and Stove 90N50A
- правила обслуживания, настройки и ухода за оборудованием Louisville Tin and Stove 90N50A
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск Louisville Tin and Stove 90N50A это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок Louisville Tin and Stove 90N50A и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта Louisville Tin and Stove, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания Louisville Tin and Stove 90N50A, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства Louisville Tin and Stove 90N50A, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции Louisville Tin and Stove 90N50A. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
Gas-Fir ed V ented FLOOR FURNACE INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 74521 REV . 08/97 MODEL NUMBERS MILLIVOL T CONTROL SYSTEM NA TURAL GAS 90N30A 90N50A 90N65A 90N75A W ARNING: If the information in this manual is not followed exactly , a fir e or explosion may result causing pr operty damage, personal injury or loss of life. - Do not s[...]
-
Страница 2
Hourly BTU Input 30,000 50,000 62,000 75,000 W idth and Length 14”x32” 22”x32” 24”x38” 26”x42” Overall Height 29-1/4” 29-1/4” 29-7/8” 30-7/8” Overall Grille Size 16”x34- c ” 24”x34” 26”x40” 28”x44” Size of Floor Opening 14 3 ”x32 3 ”2 2 2 ”x32 2 ”2 4 2 ”x38 2 ”2 6 2 ”x42 2 ” Gas Pipe Size at F[...]
-
Страница 3
HELPFUL INST ALLA TION INFORMA TION Do not attempt to heat through more than one doorway in any direction to adjoining rooms. Always over-estimate the amount of heat required rather than under-estimate it. Always use the next size floor furnace above your actual heating requirements. Seal all cracks around windows, doors, and attic access doors or [...]
-
Страница 4
FRESH AIR FOR COMBUSTION AND VENTING Adequate air for combustion and venting must be provided. Any reduction in the necessary amount of fresh air can result in an oxygen starved flame that emits Carbon Monoxide (C.O.) an odorless, colorless gas that can cause serious injur y or death. A ventilated crawl space will usually provide enough fresh air .[...]
-
Страница 5
CUTTING THE FLOOR OPENING Consult the specification chart on Page 2 for the correct floor opening size for the floor furnace to be installed. Lay out th e opening size on the floor by using masking tape or cutting a piece of cardboard to the opening size. The opening must be cut square. If you have determined that there is nothing under the floor t[...]
-
Страница 6
INST ALLING THE DRAFT HOOD The draft hood must be installed in the same atmospheric pressure zone as the combustion air inlet. The draft hood is packed in its own carton within the master pack. Make sure the draft hood received is the correct one for the floor furnace being installed. Included in the carton are two rope-like gaskets and 7 sheet met[...]
-
Страница 7
1/4” SAFE UNSAFE RECOMMENDED FIGURE 7A FIGURE 7B FIGURE 7C CONNECTING THE VENT - Continued If the floor furnace is vented into a masonry chimney , the chimney must be inspected to determine that it is clear and free of obstructions and that it is safe for the intended use. The inside of the chimney must be at least 6 inches in diameter or 6 inche[...]
-
Страница 8
If more than one gas appliance is vented through a common vent system, the vent should be increased in size to accommodate the increased load. Consult your local code or the tables in the latest edition of NFP A54/ANSI.Z223.1 for the correct size. If no local codes apply , use the following alternate method for sizing a vent connected to more than [...]
-
Страница 9
Refer to Figure 11 for the basic fittings you will need at the furnace. 1 . Use black iron or steel pipe and fittings or other pipe and fittings that are approved by local codes. 2 . Use pipe joint compound that is resistant to the action of Liquefied Petroleum (L.P .) Gas or to any other chemical constituents of the gases to be conducted through t[...]
-
Страница 10
When you have determined that there are no leaks in the gas piping system you may purge the system of air . Disconnect the pilot supply tubing from the right side of the valve. See Figure 12. Turn the knob on the gas valve to the pilot position. Press the knob down and hold until you smell gas at the pilot supply opening. Release the knob and turn [...]
-
Страница 11
FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instruc- tions exactly . B . BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHA T TO DO IF YOU SM[...]
-
Страница 12
VENT SYSTEM After the floor furnace has been burning for five minutes, hold a match or candle under the draft hood at the air intake area. If the vent system is working properly , the flame will be pulled into the air inlet of the draft hood. If the vent system is not working properly , turn the floor furnace of f immediately and refer to the insta[...]
-
Страница 13
ADJUSTING THE BURNER – Continued If difficulty in adjusting the burner is experienced, it may be the result of incorrect gas supply pressure or manifold pressure. Pressure can only be checked and adjusted by a trained service technician using instruments designed for that purpose. W ARNING: Do not attempt to change pressur e settings without prop[...]
-
Страница 14
MAINTENANCE INSTRUCTIONS CAUTION: Label all wires prior to disconnection when servicing controls. W iring errors can cause improper and dangerous operation. For proper operation, Floor Furnace must be kept clean. At regular intervals turn control valve to off, let cool, remove register and clean dust and foreign material from jacket with vacuum cle[...]
-
Страница 15
TROUBLE SHOOTING CHAR T - AUTOMA TIC PILOT & V AL VE TROUBLE SHOOTING CHAR T - MAIN BURNER SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Flame too large 1. Defective operator section of gas valve. 1. Replace complete valve. 2. Burner orifice too large. 2. Check with local gas company for proper orifice size and replace. 3. If installed above 2,000 [...]
-
Страница 16
MODELS INCLUDED: 90N30A NA T . 90N50A NA T . 90N65A NA T . 90N75A NA T . GAS FLOOR FURNACE LIST PRICES Prices and specifications subject to change witout notice. All prices are F .O.B. factory . Specify model number when ordering parts. BURNER ASSEMBL Y FOR: 90N30A 90N50A 90N65A BURNER ASSEMBL Y FOR: 90N75A MARCH 2005 Page 16 10 1 2 3 4 14 13 11 12[...]
-
Страница 17
MODEL NUMBER NA T . 90N30A 90N50A 90N65A 90N75A R E F . P ART LIST P ART LIST P A R T LIST P A RT LIST P AR T DESCRIPTION N O . N O . PRICE N O . PRICE N O . PRICE N O . PRICE Heat Exchanger w/Gasket 1 23074 $206.20 2 40 9 9 $291.10 24499 $331.90 24 6 9 9 $370.40 Gasket, Heat Exchanger N/A 74530 $4.20 7 4 53 0 $4.20 74532 $5.90 7 4 5 3 5 $7.20 Line[...]
-
Страница 18
IMPOR T ANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEA TING EQUIPMENT WHA T YOU DON’T KNOW CAN HUR T YOU. Y our pilot light system has been designed for safe and reliable operation. Although safety mechanisms are built-in, the potential for hazard exists. This information is intended to help you avoid these hazards. YOUR G[...]
-
Страница 19
LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY The Louisville Tin & Stove Co. warrants to the original user the accompanying product for the period specified herein, provided said product is installed, operated, maintained, serviced, and used according to the instructions and specifications accompanying the[...]