Marshall Electronics Network Control Box for IMD Monitors NCB-1004 инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 24 страниц
- 0.71 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Flat Panel Television
Marshall Electronics V-R72P-2HDSDI
2 страниц 4.07 mb -
Projection Television
Marshall Electronics SD/HD Widescreen LCD Monitor V-R201P-AFHD
8 страниц 0.88 mb -
Microphone
Marshall Electronics FR-310
2 страниц -
Network Card
Marshall Electronics Network Control Box for IMD Monitors NCB-1004
24 страниц 0.71 mb -
Car Video System
Marshall Electronics V-R842DP-DVI
10 страниц 0.31 mb -
Car Video System
Marshall Electronics V-R171P-HDA
6 страниц 1.31 mb -
Flat Panel Television
Marshall Electronics V-R1042DP-TE4U
4 страниц 3.32 mb -
Computer Monitor
Marshall Electronics V-R653SB-IMD
28 страниц 0.51 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации Marshall Electronics Network Control Box for IMD Monitors NCB-1004. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции Marshall Electronics Network Control Box for IMD Monitors NCB-1004 или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции Marshall Electronics Network Control Box for IMD Monitors NCB-1004 можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций Marshall Electronics Network Control Box for IMD Monitors NCB-1004, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции Marshall Electronics Network Control Box for IMD Monitors NCB-1004 должна находится:
- информация относительно технических данных устройства Marshall Electronics Network Control Box for IMD Monitors NCB-1004
- название производителя и год производства оборудования Marshall Electronics Network Control Box for IMD Monitors NCB-1004
- правила обслуживания, настройки и ухода за оборудованием Marshall Electronics Network Control Box for IMD Monitors NCB-1004
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск Marshall Electronics Network Control Box for IMD Monitors NCB-1004 это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок Marshall Electronics Network Control Box for IMD Monitors NCB-1004 и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта Marshall Electronics, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания Marshall Electronics Network Control Box for IMD Monitors NCB-1004, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства Marshall Electronics Network Control Box for IMD Monitors NCB-1004, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции Marshall Electronics Network Control Box for IMD Monitors NCB-1004. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
Marshall E lectronics NCB-1004 Network Contr ol Box for IMD M onitors Operating Instr uctions[...]
-
Страница 2
[...]
-
Страница 3
3 3 Contents Product Ov erview .............................................................. ....................................................................... ............................. 4 Features ....................................................................... .......................................................................[...]
-
Страница 4
4 Product Over view The NCB-10 04 Net work Control box is a com prehensiv e remote c ontrol solutio n for Mars hall’s IMD (In- Monitor Display) line of m onitors. T he NCB-1004 of fers complete contr ol of each monitor's menu settings and adj ustm ents such as contrast, col or, curtain c olor, as pect ratio, and more. T he NCB-10 04 can cont[...]
-
Страница 5
5 Install ation and Power- On ■ Unpacking Carefull y unpack the NC B-1004 and verif y that the f ollowing i tems are included: • NCB-1004 Network Control Box • V-PS12-5V-1 Power S uppl y with 2-Pin T wist Lock Connector • Operating Instructions Inspect the u nit for an y phys ical dam age that ma y have occurred d uring shi pping. Shoul d t[...]
-
Страница 6
6 Front and Rear Panel Features RS-422 Out puts The RS-422 outputs sen d MEI pr otocol com mands to Marshal l’s IMD line of monitor s. Each out put has exactly the s am e signal. Up to 1 28 screens c an be connected to each outp ut. T hese output ports a lso pass Im age Video or T SL v4.0 pro tocol com mands from the Control Input, embedded i n t[...]
-
Страница 7
7 Connecting to the NCB-1004 Overview The NCB-10 04 can be operated b y any com puter with a web bro wser, via a T CP/IP net work connec tion. No a dditional software is needed. T he NCB-10 04 ma y be connecte d directl y to a singl e com puter, or connec ted to a l ocal area net work and acces sed by mult iple com puters . The NCB-100 4 is shipped[...]
-
Страница 8
8 Connecti ng to t he NCB-100 4 (conti nued) Connecting the NCB-1004 to a Single Computer (cont inued) 8. Click O K in the Intern et Prot ocol (T CP/IP) Propertie s window, an d then cl ick Close i n the Local Area Connection Propertie s windo w. 9. Open an y web browser application (Internet Explorer, Firefox , etc.) 10. Enter the address http://1[...]
-
Страница 9
9 Connecti ng to t he NCB-100 4 (conti nued) Connecting the NCB-1004 to a Local A rea Netw ork If the networ k portion of the unit’s IP addres s (firs t three number s) matc hes your network , the NCB- 1004 can be connected to a local ar ea net work and acc essed fr om any com puter on th e network . The unit’s I P address m ust also be availab[...]
-
Страница 10
10 Changing t he IP Address of the NCB-1004 Overview The NCB-10 04 is ship ped with a d efault IP addr ess of 192. 168.0.233 . T his IP a ddress can be chang ed via t he network connection. Note that t he existing IP add ress must be known to make th is change. If the existin g IP ad dress is unknown , please cont act Marsh all Electron ics for a s[...]
-
Страница 11
11 Changing t he IP Address o f the NCB-1004 ( cont inued) Procedure (continued) 5. At the pass word prom pt shown bel ow, do not e nter a password a nd sim ply click O K : 6. Then, the fol lowing com m and line interfac e should app ear: 7. T y pe the follo wing com mand at the com m and prom pt, and press enter : vi /etc/network/interfaces[...]
-
Страница 12
12 Changing t he IP Address o f the NCB-1004 ( cont inued) Procedure (continued) 8. The f ollowing file inf ormation s hould appear : 9. This f ile must be edited t o save the new IP ad dress. Us e the followin g comm ands to ed it the file. Ed it only the numbers. Do not pres s the enter key after each co mmand. To move the cursor , use arr ow key[...]
-
Страница 13
13 System C onfiguration Overview The NCB-10 04 can be used in thr ee diff erent system configurat ions. The f ollowing di agram s show the dif ferent configurat ions: Basic Remote Control of IMD Monito rs ■ Overview Use the follo wing conf iguration for basic r emote c ontrol of Mars hall IMD ser ies m onitors. T his setup a llows re mote contro[...]
-
Страница 14
14 System Co nfigu ration (conti nued) Remote Control with Image Video Pass-Through ■ Overview Use the follo wing conf iguration for basic r emote c ontrol of Mars hall IMD ser ies m onitors, whi le also pas sing thr ough Image Video pr otoco l. This setup a llows rem ote control of the IMD m onitor, and p ass -through of Im age Video text and ta[...]
-
Страница 15
15 System Co nfigu ration (conti nued) Remote Control with TSL Pass-Through ■ Overview Use the follo wing conf iguration for basic r emote c ontrol of Mars hall IMD ser ies m onitors, whi le also pas sing thr ough TSL v4.0 prot ocol. This s etup allo ws rem ote control of the IMD m onitor along with pass- through of TSL text a nd tally comm ands [...]
-
Страница 16
16 Web Int erface Overview The web inter face is use d to op erate the NC B-1004. O nce the NCB-100 4 is conne cted to a net work, acc ess the web interface b y entering the units IP address in any web b rowser on a ny com puter on the network . The web interfac e allows rem ote control of all o n-screen m enu featur es of ind ividual m onitors or [...]
-
Страница 17
17 Web Inter face ( continued) Window Management The W indow Managem ent page is shown b elow: Use the butt ons and m enus sho wn above for th e follo wing settings : o As pect Ratio ( 4:3, Scaled 4:3, 16:9, Centered 16:9 / Fu ll Screen) o O n-Screen Mar kers (Aspect Rat io and Safe Ar ea Mark ers) o C enter Mark er o Mar ker Bac kground o C urtain[...]
-
Страница 18
18 Web Inter face ( continued) Preset Configuration The Preset Co nfigurat ion page is shown be low: Use the butt ons shown a bove to l oad and s ave prese ts in each m onitor. Note that thes e controls af fect the pr esets in each m onitor onl y. There are no presets in th e NCB-10 04 itself. o Load (Load pres ets Us er1 – User 6, or Factor y De[...]
-
Страница 19
19 Web Inter face ( continued) OSD Configuration & IMD The OSD Conf igurat ion & IMD page is sho wn below: Use the first s ection of the OSD & IMD pag e to set th e protoco l pass-th rough s ettings : o Set Protoco l (Image V ideo, T SL) – Select th e protoc ol type to be passed thr ough the NCB- 1004. No te that this option m ust be [...]
-
Страница 20
20 Web Inter face ( continued) S y stem The System page is s hown bel ow: Use the butt ons shown a bove to s end the f ollowing co mm ands: o Ping (Healt hy, Unhe althy) – T est a comm and and respons e with a m onitor. o Get Softw are Version – Reads th e m ain software ver sion of a m onitor. o Get Protocol Version – Reads th e protocol ver[...]
-
Страница 21
21 Web Inter face ( continued) Table of Web Interface Commands Aspect Rat io 4:3, Scaled 4:3, 16:9, 16:9 Center ed Set Marker Off, On Window Managemen t Set Center Off, On Set Backgroun d Transparent, 50% Gray, Black Set Curtain Color Blue, Red, Green, White, Black Men u Controls Menu, Select, Up, Dow n, F1, F2 Power Color Increase Value, Decrease [...]
-
Страница 22
22 Specifications ■ CONT ROL INPUT Connector 1 x RJ12 (Modular 6 P6C) Ph y sical Layer RS-422 Data Protoco ls Image Video: Start Bits 1 Data Bits 7 Parity Even Stop Bits 1 Baud Rate 3840 0 TSL v4.0 Protoc ol: Start Bits 1 Data Bits 8 Parity Even Stop Bits 1 Baud Rate 3840 0 Pinout ■ MONITO R OUT PUTS Connectors 4 x RJ12 (Modular 6 P6C) Ph y sic[...]
-
Страница 23
Specifica tions (cont inued) Warrant y Marshall El ectronics warranties to th e first c onsum er that this NCB- 1004 LCD m onitor will, under norm al use, be f ree fr om defects in workm anship and m aterials, when recei ved in its origin al container, for a peri od of one year f rom the purchas e date. T his warrant y is extended t o the firs t co[...]
-
Страница 24
Marshall Electr onics, Inc . 1910 East Maple Ave. El Segundo, CA 90245 Tel: (800) 800-6608 / (310) 333-0606 • Fax : 310-333-0688 www.LCDRacks.com • sales@lcd racks.com[...]