MRV Communications AE092FCAHA инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 33 страниц
- 2.15 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Switch
MRV Communications MR2228-S2C
41 страниц 0.48 mb -
Network Card
MRV Communications TS700/100
77 страниц 1.13 mb -
Clothes Dryer
MRV Communications HC-39
22 страниц 0.37 mb -
Clothes Dryer
MRV Communications HC-10
22 страниц 0.37 mb -
Cable Box
MRV Communications EM316-2SFP
56 страниц 0.74 mb -
Sander
MRV Communications AE242FCAKA
37 страниц 3.22 mb -
Mouse
MRV Communications TS5000/XXX (TS5000G/XYZ/V**
87 страниц 2.24 mb -
Sander
MRV Communications AE182FCAKA
37 страниц 3.22 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации MRV Communications AE092FCAHA. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции MRV Communications AE092FCAHA или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции MRV Communications AE092FCAHA можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций MRV Communications AE092FCAHA, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции MRV Communications AE092FCAHA должна находится:
- информация относительно технических данных устройства MRV Communications AE092FCAHA
- название производителя и год производства оборудования MRV Communications AE092FCAHA
- правила обслуживания, настройки и ухода за оборудованием MRV Communications AE092FCAHA
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск MRV Communications AE092FCAHA это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок MRV Communications AE092FCAHA и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта MRV Communications, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания MRV Communications AE092FCAHA, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства MRV Communications AE092FCAHA, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции MRV Communications AE092FCAHA. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
AE092FCAHA AE182FCAHA 0010570925 A Household MR V Ceiling Concealed T ype Room Air Conditioner[...]
-
Страница 2
1[...]
-
Страница 3
2[...]
-
Страница 4
3 AE092FCAHA AE182FCAHA[...]
-
Страница 5
Heating operation indication For adjusting the clock and time for timer operation. Note: This model of air conditioner doesnt provide the air sending direction adjustment function and thus the "LOU" key is disengaged while the automatic air direction indication may be displayed. This remote controller hasn't electric-aided heating in[...]
-
Страница 6
Important Points of Safety The following four important points of safety and suggestions should be paid great attention: W arning: Misuse may cause fatal result such as death or serious injury etc. Attention: Misuse may cause human injury or damage of machine, in some case fatal results. : Content marked with this ìforbiddenî sign should be absol[...]
-
Страница 7
Important Points of Safety W arning l Avoid your body being blown directly by cold wind for long period, otherwise your health may be affected. l Donít extend your fingers or any other article into the inlet or outlet during operation of the machine for touching re- volving fans may cause human injury or damage of machine. l If something abnormal [...]
-
Страница 8
Important Points of Safety Attention Attention points for use * Ensure ventilation of the room if the machine is used with burning facilities. Deficient ventilation can cause oxygen shortage. * Check whether installation bench of the machine is damaged after a long period of use. Machine on damaged bench may fall down and cause human injury or othe[...]
-
Страница 9
AUTO, F AN operation Operating instructions 2 1 3 4 Unit start Press the "ON/OFF" key to turn on the unit. The LCD on the remote controller displays the previous operating conditions (excluding previous timer , sleep and louver conditions). The remote controller operation indicator turns on. AM R 2 1 4 3 Select operation mode Press the &q[...]
-
Страница 10
2 3 1 4 5 R 3 1 2 4 5 Operating instructions COOL, DR Y , HEA T operation Recommended operation mode: Please use cooling mode in summer and heating mode in winter. Please use DRY mode in spring or autumn humid climate. Unit start Press the "ON/OFF" key to turn on the unit. The LCD on the remote controller displays the prev- ious operating[...]
-
Страница 11
4 4. Confirm the setting 12:00 12:00 AM 12:00 12:00 Operating instructions TIMER ON/OFF function Please adjust the clock before using timer function. Y ou may set the air conditioner automatically turn on or turn off when you wake in the early morning, come off work or after you fall asleep. R 1 4 2 3 1. Set the operation mode after the unit is tur[...]
-
Страница 12
12:00 12:00 12:00 12:00 * * R 1 4 2 6 3 5 TIMER ON-OFF operation Operating instructions 1. After unit starts, select your desired operation mode . The operation indicator turns on and the operation mode is displayed on the LCD screen. 2. Timer mode selection AM TIMER ON TIMER OFF TIMER ON BLANK TIMER OFF AM TIMER ON TIMER OFF TIMER ON-OFF AM AM Sel[...]
-
Страница 13
Operating instructions SLEEP function Using SLEEP function Before using this function, the time must be checked and set. After the unit starts , set the operation status , then press "SLEEP " key. Before going to bed , you can press the "SLEEP " key on the remote controller and the air condit- ioner will operate in comfortable S[...]
-
Страница 14
T roubleshooting The following cases are not troubles. During operation , the air conditioner may sometimes exhibit a sound of "clatter " or "rumble " . This is the common sound of refrigerant flow but not a trouble. A sound of "Pi-Pa " is generated. Smells are given off. During operation , mist or steam are blown out.[...]
-
Страница 15
T roubleshooting ON OFF During DRY operation, there is no air sent out or fan speed cant be changed. In HEAT mode , the outdoor unit generates water or steam. This occurs during removal of the frost (in defrosting operation) on the radiator of outdoor unit. Defrost operation In HEAT mode , the indoor fan still keeps running even the unit operation [...]
-
Страница 16
When fault occurs Poor cooling or heating Is the operation controller adjusted as required? Are there any obstructs before the air inlet or outlet? Is there any door or window left open? Poor cooling Is there any other heat source in the room? Is there any direct sunlight into the room? Are there too many people in the room? If , after the above ch[...]
-
Страница 17
Notice to users Notice to users l To ensure proper operation of the system , the user shall follow this instruction manual to install the unit. l When handling the air conditioner , please be care not to scratch the case surface. l This instruction manual describes the installation method aided with the installation tools specified by Qingdao Haier[...]
-
Страница 18
Installation precautions 17 W arning ! Before installing, do read this "Safety precautions" carefully to guarantee the proper installation. The below attentive matters are divided into" W arning " and " Note" two parts. When the wrong installation occur , it is very possible death and severe injury and other serious ac[...]
-
Страница 19
Installation precautions This description does not address to all possible cases. For new requirement and query, please consult the regional sales center of Haier Air Conditioner General Co., Ltd. This instruction manual must be read carefully before beginning of installation, improper ins- tallation may cause accidents and thus bring about machine[...]
-
Страница 20
l The power supply shall be connected from the outdoor side. (For models with electric-aided heating function, the power supply to the indoor unit shall be connected at the indoor side The power cord size is 3 x (1.25-1.5)mm 2 , type of YZW). l A separate power circuit shall be supplied and connected by a qualified electrician according to the wiri[...]
-
Страница 21
Installation procedure Fig 1 Choosing the installation location Please do not install the unit in places where flammable gases may be leaked. In case that gas is leaked and accumulated around the unit, it may cause dangers of fire etc. The indoor unit shall be installed at locations where cold and hot air could evenly circulated. The following loca[...]
-
Страница 22
1 100 223 Installation procedure Fig 2 AE182FCAHA AE092FCAHA Installation of indoor unit l The unit shall be installed according to the specifications to resist to strong wind and earthquake. Improper installation may cause dangers of unit falling down etc. After selecting the unit installation location, proceed the following steps: 1. Drill a hole[...]
-
Страница 23
Installation procedure Installation of indoor unit l When installing the cassette hind type indoor unit, a specially designed return air bellows shall be installed, as shown in Figure 3, Figure 4. l The distance between the air duct outlet and the air conditioner air outlet shall not exceed 0.5 m. 22 A *0.5m Installing building roof Ceiling Air sup[...]
-
Страница 24
Installation procedure Installation of indoor unit Installing the suspension screw: Use M8 or M10 suspension screws (4, prepared in the field) (when the suspension screw height exceeds 0.9 m, M10 size is the only choice). These screws shall be installed as follows with space adapting to air conditioner overall dimensions according to the original b[...]
-
Страница 25
Installation procedure Installation of remote controller Installation of the remote controller 1. Remove the back cover of the remote controller Firstly detach the remote controller back cover at the bottom, then detach at the top. The whole back cover of the remote controller could be removed. Remote controller bottom Remote controller back cover [...]
-
Страница 26
25 Installation procedure Drain pipe ! Caution l In order to drain water normally, the drain pipe shall be processed as specified in the installation manual and shall be thermal insulated to avoid dew generation. Improper hose connection may cause indoor water leakage. Requirements l The indoor drain pipe shall be thermal insulated. l The connectio[...]
-
Страница 27
Installation procedure R efrigerant piping l In installation, if there is refrigerant gas leakage, please take ventilation measures immediately. The refrigerant gas will generate poisonous gas upon contacting fire. l After installation, please verify that there is no refrigerant leakage. The leaked re- frigerant gas will produce poisonous gas when [...]
-
Страница 28
Installation procedure R efrigerant piping V acuum pumping W ith a vacuum pump, create vacuum from the stop valve of the outdoor unit. l Emptying with refrigerant sealed in the outdoor unit is absolutely forbidden. Open all valves Open all the valves on the outdoor unit. Gas leakage detection Check with a leakage detector or soap water that if ther[...]
-
Страница 29
Installation procedure CElectric wiring ! Warning l The electric wiring work shall be conducted by qualified electricians according to the install- ation instructions. A separate power circuit shall be used. Insufficient power cord amperage or improper wiring will cause danger of electric shock or fire. l During wiring connection, the power cord sh[...]
-
Страница 30
Installation procedure Electric wiring Wiring connection method : (the wiring diagram is attached inside the machine) 1) Ring terminal connection method Connection method f or ring terminal If there is a ring at the end of the connection wire, the wire connection method is as shown in the right figure. Remove the terminal screw and insert it throug[...]
-
Страница 31
Installation procedure Field setting Field setting Field setting the unit number In order to realize central control of the MRV air conditioning system, its necessary to set the indoor unit number (control address). Indoor unit number setting Indoor unit number setting switch and confirmation of the settings. There is a 4-position dial switch for s[...]
-
Страница 32
List of troubles List of displayed troubles on the remote controller T rouble description Ambient temperature sensor fault Indoor unit gas pipe temperature sensor abnormal Indoor unit and outdoor unit signal transmission abnormal Faulty communication between indoor unit 846 chip and 808 chip Indoor unit liquid pipe temperature sensor trouble Indoor[...]
-
Страница 33
Installation check and trial operation Check if the drain pipe and connection wires are arranged properly. The drain pipe shall be put below. The connection wire shall be put above. Be sure to wrap the drain pipe (especially the indoor part and the part inside the machine) with thermal ins- ulating materials. The drain pipe shall be made into slope[...]