Страница 1
SD5 Series Spectra ® (Softwar e V ersion 3.0) Dome Installation/ Operation Manual C1456M-D (10/98) Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120 ®[...]
-
Страница 2
2 Pelco Manual C1456M-D (10/98) CONTENTS Section Page 1.0 GENERAL .................................................................................................. 7 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS ............................... 7 1.2 REGULA TOR Y NOTICES .................................................................. 8 1.3 UNP ACKING [...]
-
Страница 3
Pelco Manual C1456M-D (10/98) 3 5.1 1.17 Alarm Pattern ...................................................................... 46 5.11.18 Zone Blank ......................................................................... 46 5.11.19 Auto Flip .............................................................................. 47 5.11.20 Proportional Pan [...]
-
Страница 4
4 Pelco Manual C1456M-D (10/98) REVISION HISTOR Y Manual # Date Comments C1456M 3/97 Original version. 4/97 Added instructions for assembling T-rail clip for metal panel per ECO 97-134. C1456M-A 4/97 Revision A. Added pendant models. 5/97 Added standard heater and sun shield. C1456M-B 7/97 Added Rev . 2 software features and low-temperature heater [...]
-
Страница 5
Pelco Manual C1456M-D (10/98) 5 C1456M-D 8/98 Manual name changed to Spectra ® (Software V ersion 3.0). In Section 2.2, revised the certifications. In Section 5.1, added information about selectable power-up mode. In Section 5.2, revised information about high zoom in turbo mode. Added Section 5.2.2, Scan Speed. In Section 5.6, added zone blanking[...]
-
Страница 6
6 Pelco Manual C1456M-D (10/98) (This page intentionally left blank.)[...]
-
Страница 7
Pelco Manual C1456M-D (10/98) 7 1.1 IMPORT ANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following W ARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA T ype 3, 3R, 3S, 4, 4X,[...]
-
Страница 8
8 Pelco Manual C1456M-D (10/98) 1.2 REGUL A TO R Y NOTICES NOTE : This equipment has been tested and found to comply with the limits of a Clas s A digital device, pursuant to part 15 of the FCC rules. These limits are de- signed to provide reasonable protection against harmful interference when the equipmen t is operated in a commercial environment[...]
-
Страница 9
Pelco Manual C1456M-D (10/98) 9 COMPASS TOOL SAFETY BRACKET CONDUIT FITTING & LOCK NUT T -RAIL CLIP Figure 2. Back Box Parts Figure 1. In-Ceiling Components BACK BOX DOME DRIVE LOWER DOME 1.3.1 In-Ceiling Models The Spectra ® (V ersion 3.0) dome shipping carton contains three boxes, plus the C1456M-D system manual that covers everything in the[...]
-
Страница 10
10 Pelco Manual C1456M-D (10/98) Figure 3. Pendant Components BACK BOX DOME DRIVE LOWER DOME 1.3.2 Pendant Models The Spectra ® (V ersion 3.0) dome shipping carton contains three boxes, plus the C1456M-D system manual that covers everything in the system (back box, dome drive, and lower dome). Inspect each box to make sure all parts are present. B[...]
-
Страница 11
Pelco Manual C1456M-D (10/98) 11 1.4 RECOMMENDED TOOLS Pelco does not supply basic tools needed for the installation process. The following tools are recommended. T o install the back box: Small flat screwdriver BNC crimp tool Wire stripper Wire cutter Pen or pencil (in-ceiling models only) Drill with 3/32-inch drill bit (in-ceiling models only) Sa[...]
-
Страница 12
12 Pelco Manual C1456M-D (10/98) 2.0 DESCRIPTION Spectra ® (V ersion 3.0) domes are capable of the following: • 360 ° pan rotation • preset positioning • +2 to -92 ° tilt • variable speed The in-ceiling models can be installed in hard ceilings or standard 2' x 2' (61 cm x 61 cm) suspended ceilings. These models are for indoor i[...]
-
Страница 13
Pelco Manual C1456M-D (10/98) 13 2.2 CERTIFICA TIONS The products identified below have been tested and certified for agency compli- ance as noted. Agency Compliance Certification Model CE FCC UL CSA/cUL Spectra ® (V er . 3) DD5-C-X X Spectra ® (V er . 3) DD5-M X X X Spectra ® (V er . 3) DD5-M-X X Spectra ® BB5A-F X X Spectra ® BB5A-PB Pending[...]
-
Страница 14
14 Pelco Manual C1456M-D (10/98) Figure 4. Compass T ool Figure 5. Conduit Fitting Installation A TT ACH SAFETY CHAIN HERE CAUTION: Be careful not to cut outside of the line. If you do, you may not be able to install the back box. Also, the trim ring may not cover the hole. NOTE: Use the SCA1 (structural ceiling adapter) if additional support is re[...]
-
Страница 15
Pelco Manual C1456M-D (10/98) 15 CAUTION: The ceiling tile must be capable of supporting 16 pounds (7.3 kg) of weight. If the ceiling tile will not support this weight, order the SD5-P metal panel. CAUTION: Be careful not to cut outside of the line. If you do, you may not be able to install the back box. Also, the trim ring may not cover the hole. [...]
-
Страница 16
16 Pelco Manual C1456M-D (10/98) Figure 8. Wiring Diagram NOTE: The dome will stop oper- ating if the voltage at the dome drops below 18 V AC. It will turn back on when the voltage exceeds 18 V AC. 3.2 WIRING Bring wiring to the back box opening in the ceiling. Do not attach the wiring to the back box. Y ou will do that later . Refer to Figure 8 fo[...]
-
Страница 17
Pelco Manual C1456M-D (10/98) 17 T able A. V ideo Coaxial Cable Wiring Distances Cable Type* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) * Minimum cable requirements: 75 ohms impedance. All-copper center conductor . All-copper braided shield with 95% braid coverage T able B. 24 V AC W iring Distances The fo[...]
-
Страница 18
18 Pelco Manual C1456M-D (10/98) OPTIONAL PROCEDURE: If you prefer , you may make the wir - ing connections inside the back box before installing the back box in the ceiling. T o do this, loosen the thumbscrew inside the back box and open the hinged door (refer to Figure 9). Bring the wiring into the back box through the conduit fitting. Follow the[...]
-
Страница 19
Pelco Manual C1456M-D (10/98) 19 Figure 11. Interconnect Circuit Board Electrical Connections Figure 10. Transformer Wiring EXAMPLE: If each dome requires 20 vA, three domes require a 60 vA transformer. DOME 1 POWER DOME 2 POWER DOME 3 POWER W ARNING: Make sure you wire power to the outer connectors of the terminal block and ground to the middle co[...]
-
Страница 20
20 Pelco Manual C1456M-D (10/98) NOTE: Connect only a low volt- age device to the relay output. Maximum current rating of the re- lay contacts is two amperes. CAUTION: The maxi- mum output of AUX 2 is 150 mA. If you connect a device that draws more current, you could destroy the output transistor . The output is intended to drive logic circuits or [...]
-
Страница 21
Pelco Manual C1456M-D (10/98) 21 T able C. Switch Settings for SW1 Control T ype Switch Setting SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 Coaxitron ® OFF OFF OFF OFF OFF OFF OFF OFF** P-T ype Control ON OFF OFF OFF OFF OFF OFF OFF** D-T ype Control OFF ON OFF OFF OFF OFF OFF* OFF** NOTES: Switches SW1-3 through SW1-6 MUST be OFF . D-type con[...]
-
Страница 22
22 Pelco Manual C1456M-D (10/98) T able D. Switch Settings for SW2 – P-Type Control NOTES: For Coaxitron ® controls, all switches on SW2 MUST be OFF . For D-type control systems, refer to T able E. Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 1 OFF OFF OFF OFF OFF 2 ON OFF OFF OFF OFF 3 OFF ON OFF OFF OFF 4 ON ON OFF OFF OFF 5 O[...]
-
Страница 23
Pelco Manual C1456M-D (10/98) 23 T able E. Switch Settings for SW2 – D-Type Control NOTES: For Coaxitron ® controls, all switches on SW2 MUST be OFF . For P-type control systems, refer to T able D. Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 O[...]
-
Страница 24
24 Pelco Manual C1456M-D (10/98) T able E. Switch Settings for SW2 – D-T ype Control (continued) Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 57 ON OFF OFF ON ON ON OFF OFF 58 OFF ON OFF ON ON ON OFF OFF 59 ON ON OFF ON ON ON OFF OFF 60 OFF OFF ON ON ON ON OFF OFF 61 ON OFF ON ON ON ON OFF OFF 62 OFF ON ON ON ON[...]
-
Страница 25
Pelco Manual C1456M-D (10/98) 25 T able E. Switch Settings for SW2 – D-T ype Control (continued) Continued on next page 117 ON OFF ON OFF ON ON ON OFF 118 OFF ON ON OFF ON ON ON OFF 119 ON ON ON OFF ON ON ON OFF 120 OFF OFF OFF ON ON ON ON OFF 121 ON OFF OFF ON ON ON ON OFF 122 OFF ON OFF ON ON ON ON OFF 123 ON ON OFF ON ON ON ON OFF 124 OFF OFF [...]
-
Страница 26
26 Pelco Manual C1456M-D (10/98) T able E. Switch Settings for SW2 - D-T ype Control (continued) Continued on next page 177 ON OFF OFF OFF ON ON OFF ON 178 OFF ON OFF OFF ON ON OFF ON 179 ON ON OFF OFF ON ON OFF ON 180 OFF OFF ON OFF ON ON OFF ON 181 ON OFF ON OFF ON ON OFF ON 182 OFF ON ON OFF ON ON OFF ON 183 ON ON ON OFF ON ON OFF ON 184 OFF OFF[...]
-
Страница 27
Pelco Manual C1456M-D (10/98) 27 T able E. Switch Settings for SW2 - D-T ype Control (continued) 237 ON OFF ON ON OFF ON ON ON 238 OFF ON ON ON OFF ON ON ON 239 ON ON ON ON OFF ON ON ON 240 OFF OFF OFF OFF ON ON ON ON 241 ON OFF OFF OFF ON ON ON ON 242 OFF ON OFF OFF ON ON ON ON 243 ON ON OFF OFF ON ON ON ON 244 OFF OFF ON OFF ON ON ON ON 245 ON OF[...]
-
Страница 28
28 Pelco Manual C1456M-D (10/98) Figure 14. Lower Dome Installation, Pendant Models NOTE: If outdoors, apply Duct Seal inside the pipe portion of the back box to prevent moisture or cold air inside the mount from en- tering the unit and causing conden- sation on the dome. Make sure no moisture has condensed inside the unit before installing the low[...]
-
Страница 29
Pelco Manual C1456M-D (10/98) 29 NOTE: For hard ceilings, such as concrete, where the wiring must be installed in surface-mounted con- duit, use the optional BB5-PCA-BK (black) or BB5-PCA-GY (gray) Pen- dant Conduit Adapter . 9. Look inside the lower dome and note which of the six retainer screws is clos- est to your finger . Remove this screw and [...]
-
Страница 30
30 Pelco Manual C1456M-D (10/98) 5.0 OPERA TION The red LED in the interconnect door in the back box lights when power is turned on and the fan operates to exhaust heat from inside the back box. If you have an outdoor pendant model with a heater , the heater elements in the back box turn on at 70 ° F (21 ° C) and turn off at 85 ° F (29 ° C). Th[...]
-
Страница 31
Pelco Manual C1456M-D (10/98) 31 5.2.1 Auto Flip When the camera tilts downward and goes just beyond the vertical position, the dome rotates 180 degrees. When the dome rotates (flips), the camera starts moving upward as long as you continue to hold the joystick in the down position. Once you let go of the joystick after the dome rotates, joystick c[...]
-
Страница 32
32 Pelco Manual C1456M-D (10/98) 5.5 RANDOM, FRAME, AND AUTO SCANNING Program preset 97 (30) to start random scanning. Program preset 98 (31) to acti- vate frame scanning (three seconds of scanning followed by a three-second pause). Program preset 99 (32) to start auto (continuous) scanning. Scan limit stops are controlled by software. Refer to Sec[...]
-
Страница 33
Pelco Manual C1456M-D (10/98) 33 In certain situations, the dome will respond as follows: • If a preset has not been set, but an alarm is connected: the dome will go to a factory preset that will not be the desired position. • If one alarm is a preset and another is a pattern and both are received: the dome will alternate between them. An alarm[...]
-
Страница 34
34 Pelco Manual C1456M-D (10/98) 5.11 PROGRAMMING THE SPECTRA™ (VERSION 3.0) The Spectra ® (V ersion 3.0) dome can be programmed for the following functions: AGC (automatic gain control) Auto park time Power-up mode Alarm dwell Auxiliary relays Proportional panning Alarm pattern Backlight compensation Scan speed Alarm priority Camera reset Sharp[...]
-
Страница 35
Pelco Manual C1456M-D (10/98) 35 5.11.1 Main Menu Access Y ou can call up the main menu on your monitor by programming (setting or creat- ing) preset 95 (28 if in 32-preset mode; refer to Section 5.4). Programming preset 95 varies according to the type of controller you are using. Instructions for programming preset 95 are given below for various c[...]
-
Страница 36
36 Pelco Manual C1456M-D (10/98) 5.11.2 Backlight Compensation There are two backlight compensation modes: on and off. Backlight compensation allows the Spectra ® (V ersion 3.0) dome to compensate for bright light behind the object you want to view . W ith backlight compensation On, the Spectra ® (V ersion 3.0) dome will use only the center 10 pe[...]
-
Страница 37
Pelco Manual C1456M-D (10/98) 37 5.11.4 Reset Camera Resetting the camera returns the following settings to their defaults. Setting: Default: Auto-focus mode Auto Gain/AGC AGC mode Auto Gain No default setting Backlight comp Off Shutter speed Auto Auto-iris Mode Auto Level Default value depends on type of camera Peak Default value depends on type o[...]
-
Страница 38
38 Pelco Manual C1456M-D (10/98) 5.11.5 Gain/AGC 5.11.5.1 AGC Mode There are three AGC (Automatic Gain Control) modes: auto, on, and of f. In the auto mode, the Spectra ® (V ersion 3.0) dome automatically adjusts the gain - the amount of amplification the camera places on its video information in order to obtain a full 1-volt peak-to-peak video si[...]
-
Страница 39
Pelco Manual C1456M-D (10/98) 39 5.11.6 Auto Iris There are three settings for auto iris: mode, level, and peak. T o change the settings for auto iris: 1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET FUNCTIONS) to access the main menu (refer to Section 5.1 1.1, MAIN MENU ACCESS). The main menu will appear . 2. If the cur[...]
-
Страница 40
40 Pelco Manual C1456M-D (10/98) 5.11.7 Shutter Speed There are nine electronic shutter speed settings: Auto 1/100 1/120 1/500 1/1000 1/2000 1/4000 1/10,000 1/30,000 In the Auto setting the camera controls the shutter speed automatically. Increasing the shutter speed lowers the light sensitivity , but rapidly moving objects will be less blurred as [...]
-
Страница 41
Pelco Manual C1456M-D (10/98) 41 5.11.8 Auto-Focus Mode There are two auto-focus modes: auto and of f. If auto focus is in the auto mode, pressing the Focus Far or Focus Near button will place the focus in the manual mode. The dome will return to auto focus if you pan or tilt the unit or do a zoom function. If the mode is set to of f, the dome will[...]
-
Страница 42
42 Pelco Manual C1456M-D (10/98) 5.11.10 White Balance (Color Cameras Only) There are three settings for white balance: auto, red-blue, and magenta-green. T o change the white balance settings: 1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET FUNCTIONS) to access the main menu (refer to Section 5.1 1.1, MAIN MENU ACCESS).[...]
-
Страница 43
Pelco Manual C1456M-D (10/98) 43 5.11.11 Line Synchronization Y ou can turn the line synchronization on or of f. If it is on, you can adjust the synchronization of the power line voltage so that it is in phase with other cameras. If cameras are out of phase with each other , they may produce what appears to be vertical roll when switching between c[...]
-
Страница 44
44 Pelco Manual C1456M-D (10/98) T o select the power-up mode: 1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4,PRESET FUNCTIONS) to access the main menu (refer to Section 5.1 1.1). The main menu will appear . 2. If the cursor (>) is not beside Power Up Mode, move the joystick up or down to position the cursor beside Power Up [...]
-
Страница 45
Pelco Manual C1456M-D (10/98) 45 5.11.15 Alarm Dwell This is the minimum time the Spectra ® (V ersion 3.0) will stay at an alarm even if the alarm is present for less than this amount of time. T o change the alarm dwell: 1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET FUNCTIONS) to access the main menu (refer to Section[...]
-
Страница 46
46 Pelco Manual C1456M-D (10/98) 5.11.17 Alarm Patter n In response to an alarm, the Spectra ® (Version 3.0) dome can do either one full pattern (1.5, 3, or 6 minutes long) or two half patterns (.75, 1.5, or 3 minutes long). Y ou can choose one of the following for each of the seven alarm inputs: • Full Pat (run full pattern) • Half Pat 2 (run[...]
-
Страница 47
Pelco Manual C1456M-D (10/98) 47 5.11.19 Auto Flip There are two auto flip modes: on or of f. When the auto flip mode is on, the auto flip feature is enabled. When it is off, the feature is disabled. T o change the auto flip mode: 1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET FUNCTIONS) to access the main menu (refer t[...]
-
Страница 48
48 Pelco Manual C1456M-D (10/98) 5.11.21 Limit Stops There are two types of limit stops: Manual limit stops Scan limit stops When manual limit stops are set, a manual (joystick) pan operation will stop when a limit stop is reached. When scan limit stops are set, the dome will reverse direction during random, frame, or auto scanning when a limit sto[...]
-
Страница 49
Pelco Manual C1456M-D (10/98) 49 5.11.22 Park Time Minutes This feature causes the dome to park at preset 1 after a programmed number of minutes of control inactivity . The time can be set from 1 minute to 720 minutes (12 hours), or it can be set to zero, which disables this feature. T o change the park time: 1. Program preset 95 (28 if in 32-prese[...]
-
Страница 50
50 Pelco Manual C1456M-D (10/98) 5.11.24 Pattern Length Y ou can set the pattern length to 1.5, 3, or 6 minutes or have two half-patterns of .75, 1.5, or 3 minutes long. T o set the pattern length: 1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET FUNCTIONS) to access the main menu (refer to Section 5.1 1.1, MAIN MENU ACCE[...]
-
Страница 51
Pelco Manual C1456M-D (10/98) 51 6.0 TROUBLESHOOTING Symptom: Unit does not operate. 1. Make sure your controller is trying to communicate with the unit and not an- other camera. 2. T urn of f power. 3. Remove the lower dome: In-Ceiling Models - Insert the flat blade of a screwdriver into one of the slots on the trim ring and twist the screwdriver [...]
-
Страница 52
52 Pelco Manual C1456M-D (10/98) Symptom: Fan does not operate. 1. T urn off power . 2. Remove the lower dome: In-Ceiling Models - Insert the flat blade of a screwdriver into one of the slots on the trim ring and twist the screwdriver to pop loose the trim ring and lower dome. Pendant Models - Remove the two screws that hold the trim ring to the ba[...]
-
Страница 53
Pelco Manual C1456M-D (10/98) 53 7.0 MAINTENANCE 7.1 DOME CLEANING Clean the acrylic dome as necessary to maintain a clear picture. Be careful not to scratch the sufaces of the dome. Exterior Surface - Clean the dome's exterior surface with a nonabrasive cleaning cloth and cleaning agent that is safe for acrylic. Either liquid or spray cleaner[...]
-
Страница 54
54 Pelco Manual C1456M-D (10/98) 8.0 SPECIFICA TIONS MECHANICAL Construction Back box: Aluminum Dome drive: Aluminum, ABS plastic Lower dome: Acrylic Cable Entry In-Ceiling: .75" (1.91 cm) conduit fitting Pendant: Through 1.5" (3.81 cm) NPT pendant mount Pan Movement: 360 ° Continuous pan rotation Vertical Tilt: Unobstructed +2 ° to -92[...]
-
Страница 55
Pelco Manual C1456M-D (10/98) 55 ELECTRICAL Input Voltage: 18-30 VAC, 24 VAC nominal Input Power In-ceiling: 25 vA Indoor pendant: 25 vA Outdoor pendant: 90 vA Fuse: 1.6 A Relay Contacts AUX 1 AUX 2 Output Type: Form C Open collector transistor output Voltage: Low voltage (<40 V) 32 VDC maximum Current: 2 A maximum 150 mA maximum GENERAL Environ[...]
-
Страница 56
56 Pelco Manual C1456M-D (10/98) BLACK AND WHITE Signal Format: EIA/CCIR Scanning System: 2:1 interlace Image Sensor 1/4-inch interline transfer EIA: Total pixels: 537 (H) x 505 (V) Effective pixels: 510 (H) x 492 (V) CCIR: Total pixels: 537 (H) x 597 (V) Effective pixels: 500 (H) x 582 (V) Resolution: 380 TV lines Lens Minimum f/stop: F/1.6 Focal [...]
-
Страница 57
Pelco Manual C1456M-D (10/98) 57 NOTES[...]
-
Страница 58
58 Pelco Manual C1456M-D (10/98) 9.0 W ARRANTY AND RETURN INFORMA TION Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. © Copyright 1998, Pelco. All rights reserved. WARRANTY Pelco will repair or replace, without charge, any merchandise proved defec[...]