Siemens Simatic M7-400 инструкция обслуживания

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638

Идти на страницу of

Хорошее руководство по эксплуатации

Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации Siemens Simatic M7-400. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции Siemens Simatic M7-400 или обучающее видео для пользователей. Условием остается четкая и понятная форма.

Что такое руководство?

Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции Siemens Simatic M7-400 можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.

К сожалению немного пользователей находит время для чтения инструкций Siemens Simatic M7-400, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.

Из чего должно состоять идеальное руководство по эксплуатации?

Прежде всего в инструкции Siemens Simatic M7-400 должна находится:
- информация относительно технических данных устройства Siemens Simatic M7-400
- название производителя и год производства оборудования Siemens Simatic M7-400
- правила обслуживания, настройки и ухода за оборудованием Siemens Simatic M7-400
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам

Почему мы не читаем инструкций?

Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск Siemens Simatic M7-400 это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок Siemens Simatic M7-400 и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта Siemens, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания Siemens Simatic M7-400, как это часто бывает в случае бумажной версии.

Почему стоит читать инструкции?

Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства Siemens Simatic M7-400, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.

После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции Siemens Simatic M7-400. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.

Содержание руководства

  • Страница 1

    Preface, Contents General T echnical Specifications 1 Racks 2 Power Supply Modules 3 Digital Modules 4 Analog Modules 5 Interface Modules 6 IM 463-2 7 PROFIBUS DP Master Interface IM 467/IM 467 FO 8 Cable Duct and Fan Subassemblies 9 RS 485 Repeater 10 CPUs for M7-400 11 M7-400 Expansions 12 Interface Submodules 13 Appendices LEERE Parameter Sets f[...]

  • Страница 2

    ! Danger indicates that death, severe personal injury or substantial property damage will result if proper precau- tions are not taken. ! W arning indicates that death, severe personal injury or substantial property damage can result if proper precautions are not taken. ! Caution indicates that minor personal injury can result if proper precautions[...]

  • Страница 3

    iii S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Preface Purpose of the Manual The manual contains reference information on operator actions, descriptions of functions and technical specifications of the central processing units, power supply modules and interface modules of the S7-400. How to configure, assemble and[...]

  • Страница 4

    Preface iv S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Changes Compared to the Previous V ersion Since the previous version of the “Module Specifications” reference manual, the following changes have been made: • The descriptions of the CPU and the CPU relevant products and topics have been put together in one[...]

  • Страница 5

    Preface v S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 System Documentation Package S7-400/M7-400 • S7-400, M7-400 Programmable Controllers; Hardware and Installation • S7-400, M7-400 Programmable Controllers; Module Specifications • Automation System S7-400 CPU Data • S7-400 Instruction List Finding Y our W [...]

  • Страница 6

    Preface vi S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Specific Information for S7-400 Y ou require the following manuals and manual packages in order to program and commission an S7-400: Manual/ Manual Package Contents Standard Software for S7 and M7 STEP 7 Basic Information • Installing and starting up STEP 7 on[...]

  • Страница 7

    Preface vii S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Specific Information for M7-400 This documentation package describes the hardware of the M7-400. Y ou will need the following additional documentation for programming and starting up an M7-400: Documentation Contents Order No. System Software for M7-300/400 Pro[...]

  • Страница 8

    Preface viii S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 A&D T echnical Support Worldwide, available 24 hours a day: Johnson City Nuernberg Beijing T echnical Support Worldwide (Nuernberg) T echnical Support 24 hours a day , 365 days a year Phone: +49 (180) 5050-222 Fax: +49 (180) 5050-223 E-Mail: adsupport@ sie[...]

  • Страница 9

    Preface ix S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Service & Support on the Internet In addition to our documentation, we offer our Know-how online on the internet at: http://www.siemens.com/automation/service&support where you will find the following: • The newsletter , which constantly provides you w[...]

  • Страница 10

    Preface x S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07[...]

  • Страница 11

    xi S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Contents 1 General T echnical Specifications 1-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Standards and Approvals 1-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 Electromagnetic Compa[...]

  • Страница 12

    Contents xii S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.12 Power Supply Module PS 405 4A; (6ES7405-0DA01-0AA0) 3-32 . . . . . . . . . . . 3.13 Power Supply Module PS 405 10A; (6ES7405-0KA00-0AA0) 3-34 . . . . . . . . . . 3.14 Power Supply Modules PS 405 10A; (6ES7405-0KA01-0AA0) and PS 405 10A R; (405-0KR00-0AA0)[...]

  • Страница 13

    Contents xiii S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.17 Digital Output Module SM 422; DO 16 24 VDC/2 A; (6ES7422-1BH1 1-0AA0) 4-62 . . . . . . . . . . . . . . . . . . . . . 4.18 Digital Output Module SM 422; DO 16 0-125 VDC/1.5 A; (6ES7422-5EH10-0AB0) 4-65 . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Страница 14

    Contents xiv S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.13 Connecting Loads/Actuators to Analog Outputs 5-58 . . . . . . . . . . . . . . . . . . . . . . 5.14 Connecting Loads/Actuators to V oltage Outputs 5-59 . . . . . . . . . . . . . . . . . . . . . . 5.15 Connecting Loads/Actuators to Current Outputs 5-61 . . [...]

  • Страница 15

    Contents xv S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 6 Interface Modules 6-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1 Common Features of the Interface Modules 6-2 . . . . . . . . . . . . . . . . . . . . . . . . . 6.2 The Interface Modules IM[...]

  • Страница 16

    Contents xvi S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 10 RS 485 Repeater 10-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1 Application and Characteristics (6ES7972-0AA01-0XA0) 10-2 . . . . . . . . . . . . . . 10.2 Appearance of the RS 485 R[...]

  • Страница 17

    Contents xvii S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13 Interface Submodules 13-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.1 Interface Submodules Overview 13-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.2 Submodule IDs[...]

  • Страница 18

    Contents xviii S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.9 IF 964-DP Interface Submodule for S7-400 and M7-400 13-61 . . . . . . . . . . . . . . 13.9.1 Pin Assignments 13-63 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.9.2 Addressing and Interrupts 13-64 .[...]

  • Страница 19

    Contents xix S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Figures 1-1 Power supply to the backup battery 1-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Structure of a Rack with 18 Slots 2-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Dimensions of the UR1 18-Sl[...]

  • Страница 20

    Contents xx S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4-19 T erminal Assignment and Block Diagram of the SM 422; DO 8 x 120/230 V AC/5 A 4-80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20 T erminal Assignment and Block Diagram of the SM 422; DO 16 x 120/230 V AC/2 A 4-84 [...]

  • Страница 21

    Contents xxi S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5-38 Block Diagram of the SM 431; AI 8 x RTD x 16 Bit 5-123 . . . . . . . . . . . . . . . . . . . . 5-39 T erminal Assignment Diagram of the SM 431; AI 8 x RTD x 16 Bit 5-124 . . . . . . 5-40 Step Response of the SM 431; AI 8 x R TD x 16 Bit 5-127 . . . . . . [...]

  • Страница 22

    Contents xxii S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1-6 POST Window for a CPU 488-3 1 1-17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-7 Warm Restart Window for a CPU 1 1-18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-8 Context-Sensitive Help Window[...]

  • Страница 23

    Contents xxiii S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13-20 Connecting Loads/Actuators via a T wo-Wire Connection to a Current Output 13-42 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-21 Connecting Loads/Actuators via a Three-Wire Connection to a V oltage Out[...]

  • Страница 24

    Contents xxiv S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T ables 1-1 Use in an Industrial Environment 1-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Products that Fulfill the Requirements of the Low-V oltage Directive 1-3 . . . . 1-3 Power Supply Modules 1-8 . . . . . . . . . . . . . . [...]

  • Страница 25

    Contents xxv S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4-17 Parameters of the SM 422; DO 16 20-125 VDC/1.5 A 4-69 . . . . . . . . . . . . . . 4-18 Parameters of the SM 422; DO 32 24 VDC/0.5 A (6ES7422-7BL00-0AB0) 4-77 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19 Dependen[...]

  • Страница 26

    Contents xxvi S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5-37 Analog V alue Representation in Output Ranges 0 and 20 mA and 4 to 20 mA 5-27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-38 Dependencies of the Analog Input/Output V alues on the Operating Mode o[...]

  • Страница 27

    Contents xxvii S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5-74 Parameters of the SM 431; AI 8 x 16 Bit 5-135 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-75 How Response T imes Depend on the Parameterized Interference Frequency Suppression and Smoothing of the SM 431; AI 8 x 16 Bit 5-136 . . . . . . . [...]

  • Страница 28

    Contents xxviii S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13-8 Socket X1, X2 IF 962-COM (9-Pin Sub D Plug Connector) 13-1 1 . . . . . . . . . . . . 13-9 Addressing the COM Ports in the A T -Compatible Address Area 13-12 . . . . . . . . 13-10 Of fset Address Assignments for the IF 962-COM Interface Submodule 13-13 [...]

  • Страница 29

    1-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 General T echnical Specifications What are General T echnical Specifications? General technical specifications include the following: • The standards and test specifications complied with and met by the modules of the S7-400/M7-400 programmable controllers • The te[...]

  • Страница 30

    General T echnical Specifications 1-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1.1 Standards and Approvals Note Y ou will find the current approvals on the identification label of the respective products. IEC 61 131-2 The S7-400/M7-400 programmable controller satisfies the requirements and criteria of the IEC 61 [...]

  • Страница 31

    General T echnical Specifications 1-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Low V oltage Directive The products listed in the table below fulfill the requirements of EU low-voltage directive (73/23/EEC). Adherence to this EU directive was tested in accordance with IEC 61 131-2. T able 1-2 Products that Fulfill[...]

  • Страница 32

    General T echnical Specifications 1-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Mark for Australia and New Zealand Our products satisfy the requirements of Standard AS/NZS 2064 (Class A). Note Y ou will recognize the approval assigned to your product from the mark on the identification label. The opprovals are lis[...]

  • Страница 33

    General T echnical Specifications 1-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 or cULus Approval, Hazardous Location CULUS Listed 7RA9 INT . CONT . EQ. FOR HAZ. LOC. Underwriters Laboratories Inc. nach  UL 508 (Industrial Control Equipment)  CSA C22.2 No. 142 (Pocess Control Equipment)  UL 1604 (Hazardou[...]

  • Страница 34

    General T echnical Specifications 1-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 cuULu requirements on hazardous location on the battery power supply for CPUs The power supply to the backup battery of a CPU must be via a non–incendive plug. The figure below portrays the concept of such connection. Battery or Powe[...]

  • Страница 35

    General T echnical Specifications 1-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Battery/Power supply CPU iput “Ext. Batt.” incl. cable Ca ≥ Ci + Cc (25nF + Cc) La ≥ Li + Lc (2mH + Lc) The batteries used must have the following properties: • Battery technology: Li/SOCL2 • Model: AA • V oltage: 3.6 V T[...]

  • Страница 36

    General T echnical Specifications 1-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 FM Approval Factory Mutual Approval Standard Class Number 361 1, Class I, Division 2, Group A, B, C, D. T emperature class: T4 at 60 ° C ambient temperature Exception: The following applies to the power supply modules in T able 1-3: ?[...]

  • Страница 37

    General T echnical Specifications 1-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Safety Requirements for Installation The S7-400/M7-400 programmable controllers are “open type” equipment to the IEC 61 131-2 standard and therefore adhere to the EU directive 73/23/EEC “Low-V oltage Directive” and are UL/CSA c[...]

  • Страница 38

    General T echnical Specifications 1-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Pulse-Shaped Interference The following table shows the electromagnetic compatibility of modules when there are pulse-shaped disturbance variables. A requirement for this is that the S7-400/M7-400 system complies with the relevant req[...]

  • Страница 39

    General T echnical Specifications 1-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Emission of Radio Interference Interference emission of electromagnetic fields in accordance with EN 5501 1: Limit value class A, Group 1. T able 1-6 Interference emission of electromagnet fields Frequency Range Limit V alue From 20 [...]

  • Страница 40

    General T echnical Specifications 1-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Additional Measures If you want to connect an S7-400 or M7-400 system to the public power system, you must ensure compliance with limit value class B in accordance with EN 55022 . Suitable additional measures must be taken, if you nee[...]

  • Страница 41

    General T echnical Specifications 1-13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Storing Backup Batteries Backup batteries must be stored in a cool, dry place. The maximum storage time is 10 years. ! W arning Improper handling of backup batteries can cause injury and material damage. If backup batteries are not tr[...]

  • Страница 42

    General T echnical Specifications 1-14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1.4 Mechanical and Ambient Climatic Conditions for Operating the S7-400/M7-400 Operating Conditions The S7-400/M7-400 is designed for weather-protected use as a permanent installation. The S7-400/M7-400 fulfills the requirements for u[...]

  • Страница 43

    General T echnical Specifications 1-15 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 1-1 1 Ambient Mechanical Conditions for the MSM 478 Mass Storage Module in Operation Frequency Range in Hz Test Values 10 ≤ f < 58 0.035 mm amplitude 10 ≤ f < 58 58 ≤ f < 500 0.035 mm amplitude 0.5 g constant acc[...]

  • Страница 44

    General T echnical Specifications 1-16 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 1-13 Ambient Climatic Conditions for the S7-400 Climatic Conditions Remark Permitted Range Relative humidity Max. 95 % at +25 ° C No condensation, corresponds to RH stressing level 2 in accordance with IEC 61131-2 Atmospheric [...]

  • Страница 45

    General T echnical Specifications 1-17 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Ambient Climatic Conditions for the M7-400 The M7-400 may be used under the following ambient climatic conditions: T able 1-15 Ambient Climatic Conditions for the M7-400 Climatic Condi- tions Permitted Range Remark Temperature 0 to +6[...]

  • Страница 46

    General T echnical Specifications 1-18 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1.5 Information on Insulation T ests, Protection Class and Degree of Protection T est V oltages Insulation resistance was demonstrated in routine testing with the following test voltages in accordance with IEC 61 131-2: T able 1-16 T [...]

  • Страница 47

    General T echnical Specifications 1-19 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1.6 Using S7-400 in a zone 2 explosion–risk area Y ou will find important information in different languages in the chapters below . Chapter overview Chapter Thema 1.6.1 Einsatz der S7-400 im explosionsgefährdeten Bereich Zone 2 1.[...]

  • Страница 48

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions 1-20 A5E00069467-07 1.6.1 Einsatz der S7-400 i m explo sionsgefährdeten Bereich Zone 2 Zone 2 Explos ionsgef ährdet e Berei che werd en in Zo nen ei ngeteilt. D ie Zone n werd en nach der Wahr scheinl ichk eit des Vor handens eins ei ner ex plosi[...]

  • Страница 49

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions A5E00069467-07 1-21 Instandhaltung Für eine Re parat ur m uss die betr off ene Bau gruppe a n den Fer tig ungsort geschick t werden. Nur d ort d arf die R eparatur durchg eführt werden. Besondere Bedingungen 1. Die SIMAT IC S7-4 00 m uss in ein e[...]

  • Страница 50

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions 1-22 A5E00069467-07 1.6.2 Use of the S7-400 in a Zone 2 Hazardous A r ea Zone 2 Hazardous areas are divi ded up into zon es. The zones are distingu ished ac cordin g to the prob abilit y of the exis tence of an expl osive a tm osphere. Zone Explosi[...]

  • Страница 51

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions A5E00069467-07 1-23 Mainte nance If repair is neces sar y, the af fected m odule m ust be s ent to the product ion loc ation. Repairs c an onl y be carr ied out ther e. Special Conditions 1. T he SIMAT IC S7-400 m us t be insta lled in a c abinet o[...]

  • Страница 52

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions 1-24 A5E00069467-07 1.6.3 Utilisation du S7-400 dans un env ironnement à risque d'explosion en zone 2 Zone 2 Les envir onnem ents à risque d'exp losion s ont ré partis en zon es. Les zones se distingu ent par l a probab ilit é de pré[...]

  • Страница 53

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions A5E00069467-07 1-25 Entretien Si une r éparatio n est néces saire, l e m odule conc erné doit être expédié au li eu de production. La répar atio n ne do it être ef fec tuée qu'en ce lieu. Conditions particulières 1. Le SIM ATIC S7- 4[...]

  • Страница 54

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions 1-26 A5E00069467-07 1.6.4 Aplicación de la S7- 400 en áreas con peligro de explosión, zona 2 Zona 2 Las áreas c on pe ligro d e ex plosión s e clas ific an en zo nas. Las zo nas se diferenc ian seg ún la pr obabil idad d e la ex istenci a de [...]

  • Страница 55

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions A5E00069467-07 1-27 Mantenimiento Para una re paraci ón se ha de rem itir el m ódulo af ecta do al lugar de f abricac ión. Sólo allí se p uede rea lizar la reparac ión. Condiciones especiales 1. El SIM ATI C S7-400 se ha de m ontar en un arm [...]

  • Страница 56

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions 1-28 A5E00069467-07 1.6.5 Impiego dell'S7-400 nell'ar ea a pericolo di esplosione zona 2 Zona 2 Le aree a pericolo di es plosion e vengono sudd ivise in zon e. Le zone veng ono distinte seco ndo la prob abilità della pr esenza di un&apos[...]

  • Страница 57

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions A5E00069467-07 1-29 Manutenzione Per una ri para zione, l'u nità interessat a dev e esser e in viata al luogo di prod uzione. La ripara zione può ess ere ef fettuata s olo lì . Condizioni particolari 1. Il SIM ATIC S7- 400 d eve es sere m o[...]

  • Страница 58

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions 1-30 A5E00069467-07 1.6.6 Gebruik van de S7-400 in het explosief gebied zone 2 Zone 2 Explos ieve geb ieden worde n ingedee ld in zones . Bij de zones wordt ondersche iden vol gens de waarsc hijnlij kheid van de aan wezighe id van een explosiev e a[...]

  • Страница 59

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions A5E00069467-07 1-31 Instandhouding Voor een re parat ie m oet de betr eff ende m odule naar de plaats van verva ardiging worden gestu urd. Alleen d aar m ag de r eparatie worden ui tgevoer d. Speciale voorwaarden 1. Het SIM ATIC S7- 400 m oet worde[...]

  • Страница 60

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions 1-32 A5E00069467-07 1.6.7 Brug af S7-400 i det e ksplosionfarlige område zone 2 Zone 2 Eks plosionsf arlige om r åder indde les i zoner. Z onern e ads killer sig in db yrdes efter hvor sands ynligt det er, at der er e n eks plosiv atm osfære. Zo[...]

  • Страница 61

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions A5E00069467-07 1-33 Vedligeholdelse Skal den pågæld ende k omponent r epareres , bedes De send e den t il produktions sted et. Repar ation m å kun udf øres der . Særlige betingelser 1. SIMAT IC S7-4 00 sk al m onteres i et k ontrolsk ab eller [...]

  • Страница 62

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions 1-34 A5E00069467-07 1.6.8 S7-400:n käy ttö räjähdy svaarannetuilla alu eilla, vy öh yke 2 Vyöhyke 2 Räjähd ysvaaran netut a lueet j aetaan vyöh ykkeis iin. Vyöh ykkeet erot ellaa n räjähd yskelpo isen ilm ak ehän olem assa olon todenn [...]

  • Страница 63

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions A5E00069467-07 1-35 Kunnossapito Korjausta vart en tä ytyy k yseinen r akenner y hm ä läh ettää valm istuspaik k aan. Korjaus v oidaan s uorittaa ainoas taan sie llä. Erityiset vaatimukset 1. SIMAT IC S7-4 00 tä ytyy as entaa k ytkentäk aap[...]

  • Страница 64

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions 1-36 A5E00069467-07 1.6.9 Användning av S7-400 i explosionsris kområde zon 2 Zon 2 Explos ionsrisk om råden del as in i zoner . Zoner na del as in e nligt sa nnolik hete n att en atmos fär m ed explos ions far a föreligger . Zon Explosionsfara[...]

  • Страница 65

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions A5E00069467-07 1-37 Underhåll Vid repar ation m åst e den ak tuella k om ponentgrup pen insän das till tillver kar en. Reparatio ner får endast ge nomf öras där. Särsk ilda v illkor 1. SIMAT IC S7-4 00 m åste m onteras i ett k oppl ingss k?[...]

  • Страница 66

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions 1-38 A5E00069467-07 1.6.10 Uso do S7-400 e m área exposta ao perigo de explosão 2 Zona 2 As áreas ex postas ao per igo de explos ão são dividida s em zonas. As zonas são diferenc iadas d e acord o co m a probabilid ade da existê ncia de um a[...]

  • Страница 67

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions A5E00069467-07 1-39 Reparo Os com ponente em questã o deve s er rem etido par a o local de produç ão a f im de que seja re alizado o repar o. Ap enas lá d eve ser efetu ado o re paro. Condições especiais 1. O SIM ATIC S7- 400 dev e ser m onta[...]

  • Страница 68

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions 1-40 A5E00069467-07 1.6.11 Χρήση της συσκευής S7-400 σε ε πικίνδυνη για έκρηξη περιοχή , ζώνη 2 Ζώνη 2 Οι επικίνδυνες για έκρηξη περιοχές χωρίζονται σε ζ[...]

  • Страница 69

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions A5E00069467-07 1-41 Συντήρηση Για µ ια επισκε υή πρέπει να σταλ θεί το αντίσ τοι χο δο µ ικό συ γκρότη µ α στον τόπο κατασκευ ής . Μόνο εκ εί επι τρέ?[...]

  • Страница 70

    General T ec hnical Sp ecif icatio ns S7-400, M7-400 Programm able Controllers Module Specificat ions 1-42 A5E00069467-07[...]

  • Страница 71

    Racks 2-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Racks Chapter Overview Section Description Page 2.1 Function and Structure of the Racks 2-2 2.2 The Racks UR1; (6ES7400-1TA01-0AA0) and UR2; (6ES7400-1JA01-0AA0) 2-3 2.3 The Rack UR2-H; (6ES7400-2JA00-0AA0) 2-5 2.4 The Rack CR2; (6ES7401-2TA01-0AA0) 2-7 2.5 The R[...]

  • Страница 72

    Racks 2-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 2.1 Function and Structure of the Racks Introduction The racks in the S7-400 have the following tasks: • They hold the modules • They supply the modules with operating voltage • They connect the individual modules to each other via the signal buses Structur[...]

  • Страница 73

    Racks 2-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 2.2 The Racks UR1; (6ES7400-1TA01-0AA0) and UR2; (6ES7400-1JA01-0AA0) Introduction The UR1 and UR2 racks are used for assembling central racks and expansion racks. The UR1 and UR2 racks have both an I/O bus and a communication bus. Suitable Modules for UR1 and UR[...]

  • Страница 74

    Racks 2-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the UR1 and UR2 Racks Rack UR1 UR2 Number of single-width slots 18 9 Dimensions W x H x D (in mm) 482.5 x 290 x 27.5 257.5 x 290 x 27.5 Weight (in kg) 3 4.1 as of version 03 1.5 2.15 as of version 04 Buses I/O bus and communication bu[...]

  • Страница 75

    Racks 2-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 2.3 The Rack UR2-H; (6ES7400-2JA00-0AA0) Introduction The UR2-H rack is used for assembling two central racks or expansion racks in one rack. The UR2-H rack essentially represents two electrically isolated UR2 racks on the same rack profile. The main area of appl[...]

  • Страница 76

    Racks 2-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 ! Caution Danger of damage to equipment. If you insert a power supply module in a slot that is not permitted for power supply modules, the module may be damaged. Slots 1 to 4 are permitted, whereby power supply modules starting from slot 1 must be inserted withou[...]

  • Страница 77

    Racks 2-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 2.4 The Rack CR2; (6ES7401-2TA01-0AA0) Introduction The CR2 rack is used for assembling segmented central racks. The CR2 has both an I/O bus and a communication bus. The I/O bus is split into two local bus segments with 10 or 8 slots. Suitable Modules for the CR2[...]

  • Страница 78

    Racks 2-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 2.5 The Rack CR3; (6ES7401-2T A01-0AA0) Introduction The CR3 rack is used for the assembly of CRs in standard systems (not in fault-tolerant systems). The CR3 has an I/O bus and a communication bus. Suitable Modules for CR 3 Y ou can use the following modules in [...]

  • Страница 79

    Racks 2-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 2.6 The Racks ER1; (6ES7403-1TA01-0AA0) and ER2; (6ES7403-1JA01-0AA0) Introduction The ER1 and ER2 racks are used for assembling expansion racks. The ER1 and ER2 racks have only one I/O bus with the following restrictions: • Interrupts from modules in the ER1 o[...]

  • Страница 80

    Racks 2-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Structure of ER1 and ER2 465 mm 240 mm 482.5 mm 257.5 mm 290 mm 190 mm 40 mm 1 2 3 4 5 6 7 8 9 1 01 11 2 1 31 4 1 51 61 7 1 8 123 456 789 1 2 3 4 5 6 7 8 9 1 01 11 21 31 4 1 51 61 7 1 8 123456 78 9 I/O bus I/O bus Figure 2-6 ER1 Rack with 18 Slots and ER2 Rack w[...]

  • Страница 81

    3-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Power Supply Modules Chapter Overview Section Description Page 3.1 Common Characteristics of the Power Supply Modules 3-2 3.2 Redundant Power Supply Modules 3-4 3.3 Backup Battery (Option) 3-6 3.4 Controls and Indicators 3-8 3.5 Fault/Error Messages via LEDs 3-13 3.6 P[...]

  • Страница 82

    Power Supply Modules 3-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.1 Common Characteristics of the Power Supply Modules T asks of the Power Supply Modules The power supply modules of the S7-400 supply the other modules in the rack with their operating voltages via the backplane bus. They do not provide load volt[...]

  • Страница 83

    Power Supply Modules 3-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Switching the Line V oltage Off/On The power supply modules have a making-current limiter in accordance with NAMUR. Power Supply Module in Invalid Slot If you insert the power supply module of a rack in an invalid slot, it will not power up. In thi[...]

  • Страница 84

    Power Supply Modules 3-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.2 Redundant Power Supply Modules Order Numbers and Function T able 3-2 Redundant power supply modules T ype Order Number Input V oltage Output V oltage See Section PS 407 10A R 6ES7407-0KR00-0AA0 85 V AC to 264 V AC or 88 VDC to 300 VDC 5 VDC/10 [...]

  • Страница 85

    Power Supply Modules 3-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Characteristics The redundant power supply of an S7-400 has the following characteristics: • The power supply module delivers a making current in accordance with NAMUR. • Each of the power supply modules can take over the supply of power to the[...]

  • Страница 86

    Power Supply Modules 3-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.3 Backup Battery (Option) Introduction The power supply modules of the S7-400 have a battery compartment for one or two backup batteries. Use of these batteries is optional. Function of the Backup Batteries If backup batteries have been installed[...]

  • Страница 87

    Power Supply Modules 3-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Backup Times The maximum backup time is based on the capacity of the backup batteries used and the backup current in the rack. The backup current is the sum of all individual currents of the inserted backed-up modules as well as the requirements of[...]

  • Страница 88

    Power Supply Modules 3-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.4 Controls and Indicators Introduction The power supply modules of the S7-400 have essentially the same controls and indicators.The main differences are: • Not all the power supply modules have a voltage selector . • Power supply modules with[...]

  • Страница 89

    Power Supply Modules 3-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Meaning of the LEDs The meaning of the LEDs on the power supply modules is described in the tables below . Section 3.5 contains a list of the faults indicated by these LEDs and notes on how to acknowledge the faults. INTF , 5 VDC, 24 VDC T able 3-3[...]

  • Страница 90

    Power Supply Modules 3-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Battery V oltage on the Backplane Bus The battery voltage is either supplied by the backup battery or externally into the CPU or receive IM. In its normal state, the level of the battery voltage is between 2.7 V and 3.6 V . The battery voltage is [...]

  • Страница 91

    Power Supply Modules 3-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Function of the Operator Controls T able 3-6 Function of the operator controls of the power supply modules FMR momentary- contact pushbut- ton For acknowledging and resetting a fault indicator after correcting the fault Standby switch Switches th[...]

  • Страница 92

    Power Supply Modules 3-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Cover The battery compartment, battery selector switch, voltage selector switch and power connection are housed under one cover . The cover must remain closed during operation in order to protect these operator controls and to prevent static elect[...]

  • Страница 93

    Power Supply Modules 3-13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.5 Fault/Error Messages via LEDs Introduction The power supply modules of the S7-400 indicate module faults and backup battery faults via LEDs on the front plate. Overview of the Fault/Error Messages T able 3-7 Error messages of the power supply [...]

  • Страница 94

    Power Supply Modules 3-14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 3-8 INTF , DC5V , DC24V LEDs, continued LED INTF Remedy Cause of Fault DC24V DC5V H D* D Short circuit or overload on 5 V and 24 V Check load on the power supply module. Possibly remove modules H D* H/D ** Short circuit or overload on 5 V C[...]

  • Страница 95

    Power Supply Modules 3-15 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 The following power supply modules will switch off in the event of a short circuit or overload after 1 s to 3 s. The module will try to restart after no more than 3 s. If the error has been eliminated by then, the module will start up. This applie[...]

  • Страница 96

    Power Supply Modules 3-16 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 BAF , BA TTF The following table applies to power supply modules with one battery if the BA TT INDIC switch is in the BA TT position. It shows the faults indicated and lists how to remedy the faults. T able 3-9 BAF , BA TTF; BA TT INDIC LEDs on BA[...]

  • Страница 97

    Power Supply Modules 3-17 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 BAF , BA TT1F , BA TT2F The following table applies to power supply modules with two batteries if the BA TT INDIC switch is in the 1BA TT position. It shows the faults indicated and lists how to remedy the faults. Nothing is indicated about the co[...]

  • Страница 98

    Power Supply Modules 3-18 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 The following table applies to power supply modules with two batteries if the BA TT INDIC switch is in the 2BA TT position. It shows the faults indicated and lists how to remedy the faults. T able 3-1 1 BAF , BA TT1F , BA TT2F; BA TT INDIC LEDs on[...]

  • Страница 99

    Power Supply Modules 3-19 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.6 Power Supply Module PS 407 4A; (6ES7407-0DA00-0AA0) Function The PS 407 4 A power supply module is designed for connecting to an AC line voltage of 120/230 V AC and supplies 5 VDC/4 A and 24 VDC/0.5 A on the secondary side. Controls and Indica[...]

  • Страница 100

    Power Supply Modules 3-20 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the PS 407 4A Programming Package Associated programming package As of STEP7 V 2.0 Dimensions, Weight, and Cable Cross-Sections Dimensions WxHxD (mm) Weight 25x290x217 0.78 kg g Cable cross-section g 3x1.5 mm 2 (litz w[...]

  • Страница 101

    Power Supply Modules 3-21 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.7 Power Supply Module PS 407 4A; (6ES7407-0DA01-0AA0) Function The PS 407 4A power supply module is designed for connecting to either an AC line voltage of 85 to 264 V or a DC line voltage of 88 to 300 V and supplies 5 VDC/4 A and 24 VDC/0.5 A o[...]

  • Страница 102

    Power Supply Modules 3-22 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Polarity Reversal of L+ and L- The polarity reversal of L+ and L- with supply voltages of between 88 VDC and 300 VDC has no effect on the function of the power supply . The connection should be made as described in the instructions in the Installa[...]

  • Страница 103

    Power Supply Modules 3-23 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.8 Power Supply Modules PS 407 10A; (6ES7407-0KA01-0AA0) and PS 407 10A R; (6ES7407-0KR00-0AA0) Function The power supply modules PS 407 10A (standard) and PS 407 10A R (redundancy-capable, see Section 3.2) are designed for connection to an AC li[...]

  • Страница 104

    Power Supply Modules 3-24 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Power Connection In contrast to the instructions on installing a power supply module described in the “S7-400, M7-400 Programmable Controllers, Hardware and Installation” manual, an AC connector is used for connecting the PS 407 10A and the PS[...]

  • Страница 105

    Power Supply Modules 3-25 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the PS 407 10A and the PS 407 10A R Dimensions, W eight, and Cable Cross-Sections Dimensions WxHxD (mm) Weight Cable cross-section 50x290x217 1.36 kg 3 x 1.5 mm 2 (litz wire with wire end ferrule with insulating collar[...]

  • Страница 106

    Power Supply Modules 3-26 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.9 Power Supply Module PS 407 20A; (6ES7407-0RA00-0AA0) Function The PS 407 20 A power supply module is designed for connecting to an AC line voltage of 120/230 V AC and supplies 5 VDC/20 A and 24 VDC/1 A on the secondary side. Controls and Indic[...]

  • Страница 107

    Power Supply Modules 3-27 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the PS 407 20 A Programming Package Associated programming package As of STEP7 V 2.0 Dimensions, Weight, and Cable Cross-Sections Dimensions WxHxD (mm) Weight Cable cross-section 75x290x217 1.93 kg 3x1.5 mm 2 (litz wir[...]

  • Страница 108

    Power Supply Modules 3-28 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.10 Power Supply Module PS 407 20A ; (6ES7407-0RA01-0AA0) Function The PS 407 20 A power supply module is designed for connecting to either an AC line voltage of 85 to 264 V AC or a DC line voltage of 88 to 300 VDC and supplies 5 VDC/20 A and 24 [...]

  • Страница 109

    Power Supply Modules 3-29 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Polarity Reversal of L+ and L- The polarity reversal of L+ and L- with supply voltages of between 88 VDC and 300 VDC has no effect on the function of the power supply . The connection should be made as described in the instructions in the Installa[...]

  • Страница 110

    Power Supply Modules 3-30 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.1 1 Power Supply Module PS 405 4A; (6ES7405-0DA00-0AA0) Function The PS 405 4 A power supply module is designed for connecting to a DC line voltage of 24 VDC and supplies 5 VDC/4 A and 24 VDC/0.5 A on the secondary side. Controls and Indicators [...]

  • Страница 111

    Power Supply Modules 3-31 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the PS 405 4 A Programming Package Associated programming package As of STEP7 V 2.0 Dimensions, Weight, and Cable Cross-Sections Dimensions WxHxD (mm) Weight 25x290x217 0.8 kg g Cable cross-section g 3 x 1.5 mm 2 (litz[...]

  • Страница 112

    Power Supply Modules 3-32 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.12 Power Supply Module PS 405 4A; (6ES7405-0DA01-0AA0) Function The PS 405 4A power supply module is designed for connection to a DC line voltage of 19.2 to 72 VDC and supplies 5 VDC/4 A and 24 VDC/0.5 A on the secondary side. Controls and Indic[...]

  • Страница 113

    Power Supply Modules 3-33 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the PS 405 4 A Dimensions, W eight, and Cable Cross-Sections Dimensions WxHxD (mm) Weight 25x290x217 0.76 kg g Cable cross-section g 3 x 1.5 mm 2 (litz wire with wire end ferrule; use component use componen t conductor[...]

  • Страница 114

    Power Supply Modules 3-34 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.13 Power Supply Module PS 405 10A; (6ES7405-0KA00-0AA0) Function The PS 405 10A power supply module is designed for connection to a DC line voltage of 24 VDC and supplies 5 VDC/10 A and 24 VDC/1 A on the secondary side. Controls and Indicators o[...]

  • Страница 115

    Power Supply Modules 3-35 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the PS 405 10 A Programming Package Associated programming package As of STEP7 V 2.0 Dimensions, Weight, and Cable Cross-Sections Dimensions WxHxD (mm) Weight 50x290x217 1 4 kg W e i g h t Cable cross-section 1 .4 k g [...]

  • Страница 116

    Power Supply Modules 3-36 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.14 Power Supply Modules PS 405 10A; (6ES7405-0KA01-0AA0) and PS 405 10A R; (405-0KR00-0AA0) Function The power supply modules PS 405 10A (standard) and PS 405 10A R (redundancy-capable, see Section 3.2) are designed for connection to a DC line v[...]

  • Страница 117

    Power Supply Modules 3-37 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the PS 405 10A and the PS 405 10A R Dimensions, W eight, and Cable Cross-Sections Dimensions WxHxD (mm) Weight 50x290x217 1 4 kg W e i g h t Cable cross-section 1 .4 k g 3 x 1.5 mm 2 (litz wire ith i d f l ( with wire [...]

  • Страница 118

    Power Supply Modules 3-38 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.15 Power Supply Module PS 405 20A; (6ES7405-0RA00-0AA0) Function The PS 405 20 A power supply module is designed for connecting to a DC line voltage of 24 VDC and supplies 5 VDC/20 A and 24 VDC/1 A on the secondary side. Controls and Indicators [...]

  • Страница 119

    Power Supply Modules 3-39 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the PS 405 20 A Programming Package Associated programming package As of STEP7 V 2.0 Dimensions, Weight, and Cable Cross-Sections Dimensions WxHxD (mm) Weight 75x290x217 2 2 kg W e i g h t Cable cross-section 2 . 2 k g[...]

  • Страница 120

    Power Supply Modules 3-40 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3.16 Power Supply Module PS 405 20A; (6ES7405-0RA01-0AA0) Function The PS 405 20A power supply module is designed for connection to a DC line voltage of 19.2 VDC to 72 VDC and supplies 5 VDC/20 A and 24 VDC/1 A on the secondary side. Controls and [...]

  • Страница 121

    Power Supply Modules 3-41 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the PS 405 20 A Dimensions, W eight, and Cable Cross-Sections Dimensions WxHxD (mm) Weight 75x290x217 2 2 kg W e i g h t Cable cross-section 2 . 2 k g 3x1.5 mm 2 (litz wire ith i d f l ( with wire end ferrule; use comp[...]

  • Страница 122

    Power Supply Modules 3-42 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07[...]

  • Страница 123

    4-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Digital Modules Structure of the Chapter The present chapter is subdivided into the following subjects: 1. Overview containing the modules that are available here and a description 2. Information that is generally valid – in other words, relating to all digital modul[...]

  • Страница 124

    Digital Modules 4-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Chapter Overview Section Description Page 4.1 Module Overview 4-3 4.2 Sequence of Steps from Choosing to Commissioning the Digital Module 4-5 4.3 Digital Module Parameter Assignment 4-6 4.4 Diagnostics of the Digital Modules 4-9 4.5 Interrupts of the Di[...]

  • Страница 125

    Digital Modules 4-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.1 Module Overview Introduction The following tables summarize the most important characteristics of the digital modules. This overview is intended to make it easy to choose the suitable module for your task. T able 4-1 Digital Input Modules: Character[...]

  • Страница 126

    Digital Modules 4-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 4-2 Digital Output Modules: Characteristics at a Glance Module Characte- ristics SM 422; DO 16 24 VDC/2 A (-1BH1x) SM 422; DO 16 20-125 VDC/1.5 A (-5EH10) SM 422; DO 32 24 VDC/ 0.5 A (-1BL00) SM 422; DO 32 24 VDC/0.5 A (-7BL00) SM 422; DO 8 120/2[...]

  • Страница 127

    Digital Modules 4-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.2 Sequence of Steps from Choosing to Commissioning the Digital Module Introduction The following table contains the tasks that you have to perform one after the other to commission digital modules successfully . The sequence of steps is a suggestion, [...]

  • Страница 128

    Digital Modules 4-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.3 Digital Module Parameter Assignment Introduction Digital modules can have different characteristics. Y ou can set the characteristics of dome modules by means of parameter assignment. T ools for Parameter Assignment Y ou assign parameters to digital[...]

  • Страница 129

    Digital Modules 4-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.3.1 Parameters of the Digital Input Modules The parameterized digital input modules use a subset of the parameters and ranges of values listed in the table below , depending on functionality . Refer to the section on a particular digital module, start[...]

  • Страница 130

    Digital Modules 4-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.3.2 Parameters of the Digital Output Modules The parameterized digital output modules use a subset of the parameters and ranges of values listed in the table below , depending on the functionality . Refer to the section on the relevant digital module,[...]

  • Страница 131

    Digital Modules 4-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.4 Diagnostics of the Digital Modules Programmable and Non-Programmable Diagnostic Messages In diagnostics, we make a distinction between programmable and non-programmable diagnostic messages. Y ou obtain programmable diagnostic messages only if you ha[...]

  • Страница 132

    Digital Modules 4-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Diagnostic Messages of the Digital Modules The table below gives an overview of the diagnostic messages for the digital modules with diagnostics capability . Y ou can find out which diagnostic message each module is capable of in the Appendix entitled [...]

  • Страница 133

    Digital Modules 4-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Causes of Errors and Remedial Measures for Digital Modules T able 4-9 Diagnostic Messages of the Digital Modules, Causes of Errors and Remedial Measures Diagnostic Message Possible Error Cause Remedy Module malfunction An error detected by the module [...]

  • Страница 134

    Digital Modules 4-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 4-9 Diagnostic Messages of the Digital Modules, Causes of Errors and Remedial Measures, continued Diagnostic Message Remedy Possible Error Cause Wire break Lines interrupted Close circuit No external sensor supply Wire sensors with 10 to 18 k ?[...]

  • Страница 135

    Digital Modules 4-13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.5 Interrupts of the Digital Modules Introduction This section describes the interrupt behavior of the digital modules. The following interrupts exist: • Diagnostic Interrupt • Hardware interrupt Note that not all digital modules have interrupt ca[...]

  • Страница 136

    Digital Modules 4-14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Hardware Interrupt A digital input module can trigger a hardware interrupt for each channel at a rising or falling edge, or both, of a signal status change. Y ou perform parameter assignment for each channel separately . It can be modified at any time [...]

  • Страница 137

    Digital Modules 4-15 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.6 Input Characteristic Curve for Digital Inputs IEC 61 131, T ype 1 and T ype 2 The IEC 61 131 standard requires the following for the input current: • In the case of type 2, an input current of y 2 mA already at + 5 V • In the case of type 1, an[...]

  • Страница 138

    Digital Modules 4-16 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Input Characteristic Curve for Digital Inputs As long as the current flowing into the module remains v 1.5 mA, the module recognizes this as a “0” signal. 0.5 1.5 2 6 7 0 5 1 1 13 15 24 30 I min to IEC 61 131; type 2 I min to IEC 61 131; type 1 T y[...]

  • Страница 139

    Digital Modules 4-17 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.7 Digital Input Module SM 421; DI 32 24 VDC (6ES7421-1BL00-0AA0) Characteristics The SM 421;DI 32 x 24 VDC is a digital input module with the following features: • 32 inputs, isolated in a group of 32. In other words, all inputs share the same chas[...]

  • Страница 140

    Digital Modules 4-18 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the Digital Input Module SM 421; DI 32 x 24 VDC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 7 L+ 0 M 1 2 3 [...]

  • Страница 141

    Digital Modules 4-19 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 421; DI 32 x 24 VDC Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 600 g Data for Specific Module Number of inp[...]

  • Страница 142

    Digital Modules 4-20 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.8 Digital Input Module SM 421; DI 32 24 VDC; (6ES7421-1BL01-0AA0) Characteristics The digital input module SM 421; DI 32 24 VDC has the following features: • 32 inputs, isolated in a group of 32 • 24 VDC rated input voltage • Suitable for switc[...]

  • Страница 143

    Digital Modules 4-21 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 421; DI 32 24 VDC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 7 0 M 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 [...]

  • Страница 144

    Digital Modules 4-22 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 421; DI 32 x 24 VDC Dimensions and W eight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 500 g Data for Specific Module Number of inputs 32 Length of cable • Unshielded • Shielded Max. 600 m Max. 10[...]

  • Страница 145

    Digital Modules 4-23 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.9 Digital Input Module SM 421; DI 16 24 VDC; (6ES7421-7BH00-0AB0) Characteristics The digital input module SM 421; DI 16 24 VDC has the following features: • 16 inputs, isolated in 2 groups of 8 • 24 VDC rated input voltage • Suitable for switc[...]

  • Страница 146

    Digital Modules 4-24 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 421; DI 16 24 VDC INT F EXTF 1L+ 0 1 2 3 1Vs 4 5 6 7 1M 1M 2L+ 2L+ 0 1 2 3 2Vs 4 5 6 7 2M 2M 1L+ 2M 2L+ 1M M L+ 1L+ 1L+ 2L+ 1M 2M 2M 1M Backplane bus interface 24 V 24 V 24 V Front connector monitoring M[...]

  • Страница 147

    Digital Modules 4-25 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram for Redundant Supply of Sensors The figure below shows how sensors can additionally be supplied by means of Vs with a redundant voltage source – for example, via another module). Vs M L+ 1 L+ 2 L+ to the sensors ± Digita[...]

  • Страница 148

    Digital Modules 4-26 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Status, Interrupts, Diagnostics Status display Green LED per channel Interrupts • Hardware interrupt • Diagnostic Interrupt Parameters can be assigned Parameters can be assigned Diagnostic functions • Monitoring of the power supply voltage of the[...]

  • Страница 149

    Digital Modules 4-27 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.9.1 Assigning Parameters to the SM 421; DI 16 24 VDC Parameter Assignment Y ou will find a description of the general procedure for assigning parameters to digital modules in Section 5.7. Parameters of the SM 421; DI 16 24 VDC Y ou will find an overv[...]

  • Страница 150

    Digital Modules 4-28 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Ensuring a Wire Break Check Is Carried Out T o ensure that a wire break check is carried out, you require an external sensor circuit using a resistor of 10 to 18 k  The resistor should be connected parallel to the contact and should be arranged a[...]

  • Страница 151

    Digital Modules 4-29 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.9.2 Behavior of the SM 421; DI 16 24 VDC Effect of Operating Mode and Supply V oltage on the Input V alues The input values of the SM 421; DI 16 24 DC depend on the operating mode of the CPU and on the supply voltage of the module. T able 4-1 1 How t[...]

  • Страница 152

    Digital Modules 4-30 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Effect of Errors and Parameter Assignment on the Input V alues The input values of the SM 421; DI 16 24 DC are affected by certain errors and the parameter assignment of the module. The following table lists the effects on the input values. Y ou will f[...]

  • Страница 153

    Digital Modules 4-31 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Behavior when the Input Delay Equals 0.1 ms and an Error Occurs If you have parameterized the following: • An input delay of 0.1 ms • KL V or SV as the response to an error • Substitute “1” In the event of a fault on a channel that has a 1 si[...]

  • Страница 154

    Digital Modules 4-32 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.10 Digital Input Module SM 421; DI 16 24 VDC; (6ES7421-7BH01-0AB0) Characteristics The digital input module SM 421; DI 16 24 VDC has the following features: • 16 inputs, isolated in 2 groups of 8 • 24 VDC rated input voltage • Suitable for swit[...]

  • Страница 155

    Digital Modules 4-33 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 421; DI 16 24 VDC INT F EXTF 1L+ 0 1 2 3 1Vs 4 5 6 7 1M 1M 2L+ 2L+ 0 1 2 3 2Vs 4 5 6 7 2M 2M 1L+ 2M 2L+ 1M M L+ 1L+ 1L+ 2L+ 1M 2M 2M 1M Backplane bus interface 24 V 24 V 24 V Front connector monitoring M[...]

  • Страница 156

    Digital Modules 4-34 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram for Redundant Supply of Sensors The figure below shows how sensors can additionally be supplied by means of Vs with a redundant voltage source – for example, via another module). Vs M L+ 1 L+ 2 L+ to the sensors ± Digita[...]

  • Страница 157

    Digital Modules 4-35 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Status, Interrupts, Diagnostics Status display Green LED per channel Interrupts • Hardware interrupt • Diagnostic Interrupt Parameters can be assigned Parameters can be assigned Diagnostic functions • Monitoring of the power supply voltage of the[...]

  • Страница 158

    Digital Modules 4-36 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.10.1 Assigning Parameters to the SM 421; DI 16 24 VDC Parameter Assignment Y ou will find a description of the general procedure for assigning parameters to digital modules in Section 5.7. Parameters of the SM 421; DI 16 24 VDC Y ou will find an over[...]

  • Страница 159

    Digital Modules 4-37 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Ensuring a Wire Break Check Is Carried Out T o ensure that a wire break check is carried out, you require an external sensor circuit using a resistor of 10 to 18 k  The resistor should be connected parallel to the contact and should be arranged a[...]

  • Страница 160

    Digital Modules 4-38 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.10.2 Behavior of the SM 421; DI 16 24 VDC Effect of Operating Mode and Supply V oltage on the Input V alues The input values of the SM 421; DI 16 24 DC depend on the operating mode of the CPU and on the supply voltage of the module. T able 4-14 How t[...]

  • Страница 161

    Digital Modules 4-39 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Effect of Errors and Parameter Assignment on the Input V alues The input values of the SM 421; DI 16 24 DC are affected by certain errors and the parameter assignment of the module. The following table lists the effects on the input values. Y ou will f[...]

  • Страница 162

    Digital Modules 4-40 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Behavior when the Input Delay Equals 0.1 ms and an Error Occurs If you have parameterized the following: • An input delay of 0.1 ms or 0.05 ms • KL V or SV as the response to an error • Substitute “1” In the event of a fault on a channel that[...]

  • Страница 163

    Digital Modules 4-41 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.1 1 Digital Input Module SM 421; DI 16 120 V AC ; (6ES7421-5EH00-0AA0) Characteristics The SM 421; DI 16 120 V AC has the following features: • 16 inputs, isolated • 120 V AC rated input voltage • Suitable for switches and two-wire proximity sw[...]

  • Страница 164

    Digital Modules 4-42 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram of the SM 421; DI 16 120 V AC 1 2 3 4 0 Byte 0 5 6 1 7 8 2 9 10 3 11 13 1N 12 14 15 4 16 17 5 18 19 6 20 21 7 22 24 23 26 27 28 29 30 31 32 33 34 36 35 38 39 40 41 42 43 44 45 46 48 47 25 37 0 1 2 3 4 5 6 7 2N 3N 4N 5N 6N 7[...]

  • Страница 165

    Digital Modules 4-43 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 421; DI 16 120 V AC Dimensions and W eight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 650 g Data for Specific Module Number of inputs 16 Length of cable • Unshielded • Shielded 600 m 1000 m V olt[...]

  • Страница 166

    Digital Modules 4-44 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.12 Digital Input Module SM 421; DI 16 24/60 VUC; (6ES7 421-7DH00-0AB0) Characteristics The SM 421; DI 16 24/60 VUC is characterized by the following features: • 16 inputs, individually isolated • Rated input voltage 24 VUC to 60 VUC • Suitable [...]

  • Страница 167

    Digital Modules 4-45 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 421; DI 16 24/60 VUC L N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 N 1 2 4 N 4 5 6 0 2 N 3 N 3 5 N 6 N 7 N 7[...]

  • Страница 168

    Digital Modules 4-46 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 421; DI 16 24/60 VUC Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 600 g Data for Specific Module Number of in[...]

  • Страница 169

    Digital Modules 4-47 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.12.1 Assigning Parameters to the SM 421; DI 16 24/60 VUC Parameter Assignment Y ou will find a description of the general procedure for assigning parameters to digital modules in Section 4.3. Parameters of the SM 421; DI 16 24/60 VUC The following ta[...]

  • Страница 170

    Digital Modules 4-48 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Setting the Input Delay for Channel Groups Y ou can only set the input delay for each group of channels. In other words, the setting for channel 0 applies to inputs 0 to 7 and the setting for channel 8 applies to inputs 8 to 15. Note The parameters tha[...]

  • Страница 171

    Digital Modules 4-49 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Circuit as for active high or active low input ”1” ”0” 0V – L+ U_s ”1” U_s DI_x ”1” ”0” 0V L+ – L+ U_s DI_xN Channel x of the DI 421 16 x 24/60 VUC L+ U_s Input threshold Active high Active low Figure 4-10 Circuit as for Active [...]

  • Страница 172

    Digital Modules 4-50 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.13 Digital Input Module SM 421; DI 16 120/230 VUC; (6ES7 421-1FH00-0AA0) Characteristics The SM 421; DI 16 120/230 VUC is characterized by the following features: • 16 inputs, isolated • Rated input voltage 120/230 V AC/VDC • Suitable for switc[...]

  • Страница 173

    Digital Modules 4-51 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 421; DI 16 120/230 VUC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 4 N 3 N 1 2 0 3 5 6 4 7 5 6 4 7 1 2 0 3 1N 2N[...]

  • Страница 174

    Digital Modules 4-52 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 421; DI 16 120/230 VUC Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 650 g Data for Specific Module Number of [...]

  • Страница 175

    Digital Modules 4-53 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.14 Digital Input Module SM 421; DI 16 120/230 VUC; (6ES7421-1FH20-0AA0) Characteristics The SM 421; DI 16 120/230 VUC is characterized by the following features: • 16 inputs, isolated in groups of 4 • Rated input voltage 120/230 VUC • Input cha[...]

  • Страница 176

    Digital Modules 4-54 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 421; DI 16 120/230 VUC 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 0 3 5 6 4 7 5 6 4 7 1 2 0 3 4N 1N Data regis[...]

  • Страница 177

    Digital Modules 4-55 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 421; DI 16 x 120/230 VUC Dimensions and W eight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 650 g Data for Specific Module Number of inputs 16 Length of cable • Unshielded • Shielded 600 m 1000 m [...]

  • Страница 178

    Digital Modules 4-56 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.15 Digital Input Module SM 421; DI 32 120 VUC ; (6ES7421-1EL00-0AA0) Characteristics The SM 421; DI 32 120 VUC is characterized by the following features: • 32 inputs, isolated • Rated input voltage 120 V AC/VDC • Suitable for switches and two-[...]

  • Страница 179

    Digital Modules 4-57 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 421; DI 32 120 VUC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 7 0 4N 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 [...]

  • Страница 180

    Digital Modules 4-58 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 421; DI 32 120 VUC Dimensions and W eight Dimensions W H D (mm) 25 290 210 Weight Approx. 600 g Data for Specific Module Number of inputs 32 Length of cable • Unshielded • Shielded 600 m 1000 m V oltages, Current[...]

  • Страница 181

    Digital Modules 4-59 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.16 Digital Output Module SM 422; DO 16 24 VDC/2 A; (6ES7422-1BH10-0AA0) Characteristics The digital output module SM 422; DO 16 24 VDC/2 A has the following features. • 16 outputs, isolated in two groups of 8 • 2 A output current • 24 VDC rated[...]

  • Страница 182

    Digital Modules 4-60 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 422; DO 16 24 VDC/2 A Data register and bus control LED control 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 0 3[...]

  • Страница 183

    Digital Modules 4-61 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 422; DO 16 24 VDC/2 A Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 600 g Data for Specific Module Number of o[...]

  • Страница 184

    Digital Modules 4-62 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.17 Digital Output Module SM 422; DO 16 24 VDC/2 A; (6ES7422-1BH1 1-0AA0) Characteristics The digital output module SM 422; DO 16 24 VDC/2 A has the following features. • 16 outputs, isolated in two groups of 8 • 2 A output current • 24 VDC rate[...]

  • Страница 185

    Digital Modules 4-63 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 422; DO 16 24 VDC/2 A Data register and bus control LED control 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 0 3[...]

  • Страница 186

    Digital Modules 4-64 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 422; DO 16 24 VDC/2 A Dimensions and W eight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 600 g Data for Specific Module Number of outputs 16 Length of cable • Unshielded • Shielded 600 m 1000 m V [...]

  • Страница 187

    Digital Modules 4-65 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.18 Digital Output Module SM 422; DO 16 20-125 VDC/1.5 A; (6ES7422-5EH10-0AB0) Characteristics The SM 422; DO 16 20-125 VDC/1.5 A has the following features: • 16 outputs, each channel is fused; reverse polarity protection and isolated in groups of [...]

  • Страница 188

    Digital Modules 4-66 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram of the SM 422; DO 16 20-125 VDC/1.5 A 1 2 3 4 0 Byte 0 5 6 1 7 8 2 9 10 3 11 13 L1+ 12 14 15 4 16 17 5 18 19 6 20 21 7 22 24 23 26 27 28 29 30 31 32 33 34 36 35 38 39 40 41 42 43 44 45 46 48 47 25 37 0 1 2 3 4 5 6 7 M1 –+[...]

  • Страница 189

    Digital Modules 4-67 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 422; DO 16 20-125 VDC/1.5 A Dimensions and W eight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 800 g Data for Specific Module Number of outputs 16 Length of cable • Unshielded • Shielded Max. 600 [...]

  • Страница 190

    Digital Modules 4-68 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Note If the power supply is switched on by means of a mechanical contact, a voltage pulse may occur at the outputs. The transient pulse lasts a maximum of 0.5 ms. Changing Fuses ! W arning This can result in injury . If you change a fuse without removi[...]

  • Страница 191

    Digital Modules 4-69 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.18.1 Assigning Parameters to the SM 422; DO 16 20-125 VDC/1.5 A Parameter Assignment Y ou will find a description of the general procedure for assigning parameters to digital modules in Section 5.7. Parameters of the SM 421; DO 16 20-125 VDC/1.5 A Y [...]

  • Страница 192

    Digital Modules 4-70 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.19 Digital Output Module SM 422; DO 32 24 VDC/0.5 A; (6ES7422-1BL00-0AA0) Characteristics The SM 422; DO 32 x 24 VDC/0.5 A has the following features: • 32 outputs, isolated in a group of 32 • Power is supplied to 8 channels in groups. • A supp[...]

  • Страница 193

    Digital Modules 4-71 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 422; DO 32 24 VDC/0.5 A L+ 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 4 7 0 3 5 6 1 2 4 7 0 3 5 6 1 2 4 7 0 3 [...]

  • Страница 194

    Digital Modules 4-72 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 422; DO 32 24 VDC/0.5 A Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 600 g Data for Specific Module Number of[...]

  • Страница 195

    Digital Modules 4-73 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.20 Digital Output Module SM 422; DO 32 24 VDC/0.5 A; (6ES7422-7BL00-0AB0) Characteristics The digital output module SM 422; DO 32 24 VDC/0.5 A has the following features: • 32 outputs, fused and isolated in groups of 8 • 0.5 A output current • [...]

  • Страница 196

    Digital Modules 4-74 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 422; DO 32 24 VDC/0.5 A INTF EXTF 1L+ 0 1 2 3 4 5 6 7 1M 2L+ 2L+ 0 1 2 3 4 5 6 7 2M 2M 3L+ 3L+ 0 1 2 3 4 5 6 7 3M 3M 4L+ 4L+ 0 1 2 3 4 5 6 7 4M 4M 1L+ 1L+ 2L+ Backplane bus interface 1M 2L+ 3L+ 4L+ 3M 4M[...]

  • Страница 197

    Digital Modules 4-75 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 422; DO 32 24 VDC/0.5 A Dimensions and W eight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 600 g Data for Specific Module Number of outputs 32 Length of cable • Unshielded • Shielded 600 m 1000 m [...]

  • Страница 198

    Digital Modules 4-76 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Time, Frequency Internal preparation time between backplane bus and input of the output driver 1) Up to hardware release 03 • independent of enable diagnostics/diagnostic interrupt/ substitute value max. 100  s Up to hardware release 04 • withou[...]

  • Страница 199

    Digital Modules 4-77 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.20.1 Assigning Parameters to the SM 422; DO 32 24 VDC/0.5 A Parameter Assignment Y ou will find a description of the general procedure for assigning parameters to digital modules in Section 5.7. Parameters of the SM 422; DO 32 24 VDC/0.5 A Y ou will [...]

  • Страница 200

    Digital Modules 4-78 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.20.2 Behavior of the SM 422; DO 32 24 VDC/0.5 A Effect of Operating Mode and Supply V oltage on the Output V alues The output values of the SM 422; DO 32 24 VDC/0.5 A depend on the operating mode of the CPU and on the supply voltage of the module. T [...]

  • Страница 201

    Digital Modules 4-79 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.21 Digital Output Module SM 422; DO 8 120/230 V AC/5 A; (6ES7422-1FF00-0AA0) Characteristics The SM 422; DO 8 120/230 V AC/5 A has the following features: • 8 outputs, isolated in groups of 1 • Output current 5 A • 120/230 V AC rated load volta[...]

  • Страница 202

    Digital Modules 4-80 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 422; DO 8 120/230 V AC/5 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1L 1N 1 2L 0 7L 7N 7 8L 6 3L 3N 3 4L 2 5L[...]

  • Страница 203

    Digital Modules 4-81 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 422; DO 8 120/230 V AC/5 A Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 800 g Data for Specific Module Number[...]

  • Страница 204

    Digital Modules 4-82 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Changing Fuses ! W arning This can result in injury . If you change a fuse without removing the front connector of the module, you could be injured by an electric shock. Consequently , always remove the front connector before you change the fuse.[...]

  • Страница 205

    Digital Modules 4-83 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.22 Di gi tal O ut pu t M odule S M 422; DO 16 120/230 V AC/2 A; (6ES7422-1FH00-0AA0) Characteristics The SM 422; DO 16 120/230 V AC/2 A has the following features: • 16 outputs, isolated in groups of 4 • 2 A output current • 120/230 V AC rated [...]

  • Страница 206

    Digital Modules 4-84 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the SM 422; DO 16 120/230 V AC/2 A Byte 0 16 digital outputs (4 chassis grounds) Byte 1 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 47 46 48 Data reg[...]

  • Страница 207

    Digital Modules 4-85 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 422; DO 16 120/230 V AC/2 A Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight DimensionsW H D (in millimeters) 25 290 210 Weight Approx. 800 g Data for Specific Module Number[...]

  • Страница 208

    Digital Modules 4-86 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Changing Fuses ! W arning This can result in injury . If you change a fuse without removing the front connector of the module, you could be injured by an electric shock. Consequently , always remove the front connector before you change the fuse.[...]

  • Страница 209

    Digital Modules 4-87 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.23 Digital Output Module SM 422; DO 16 20-120 V AC/2 A; (6ES7422-5EH00-0AB0) Characteristics The SM 422; DO 16 20-120 V AC/2 A has the following features: • 16 outputs, isolated in groups of 1 • 2 A output current • Rated load voltage 20 V AC t[...]

  • Страница 210

    Digital Modules 4-88 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram of the SM 422; DO 16 20-120 V AC/2 A 1 2 3 4 0 Byte 0 5 6 1 7 8 2 9 10 3 11 13 1L1 12 14 15 4 16 17 5 18 19 6 20 21 7 22 24 23 26 27 28 29 30 31 32 33 34 36 35 38 39 40 41 42 43 44 45 46 48 47 25 37 0 1 2 3 4 5 6 7 2L1 3L1 [...]

  • Страница 211

    Digital Modules 4-89 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 422; DO 16 20-120 V AC/2 A Dimensions and W eight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 800 g Data for Specific Module Number of outputs 16 Length of cable • Unshielded • Shielded Max. 600 m[...]

  • Страница 212

    Digital Modules 4-90 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Changing Fuses ! W arning This can result in injury . If you change a fuse without removing the front connector of the module, you could be injured by an electric shock. Consequently , always remove the front connector before you change the fuse. 4.23.[...]

  • Страница 213

    Digital Modules 4-91 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 4.24 R e l a y O u t p u t M odule SM 422; DO 16 30/230 VUC/Rel. 5 A; (6ES7422-1HH00-0AA0) Characteristics T h e SM 422; DO 16 30/230 VUC/Rel. 5 A has the following features: • 16 outputs, isolated in 8 groups of 2 • Output current 5 A • Rated lo[...]

  • Страница 214

    Digital Modules 4-92 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment and Block Diagram of the S M 422; DO 16 30/230 VUC/Rel. 5 A Data register and bus control LED control 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 [...]

  • Страница 215

    Digital Modules 4-93 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the S M 422; DO 16 30/230 VUC/Rel. 5 A Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 700 g Data for Specific Module N[...]

  • Страница 216

    Digital Modules 4-94 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Note Use a suppressor circuit in environments with high humidity and where sparks might occur at the relay contacts. This will increase the life of the relay contacts. T o do this, connect an RC element or a varistor parallel to the relay contacts or t[...]

  • Страница 217

    5-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog Modules Structure of the Chapter The present chapter is broken down into the following subjects: 1. Overview containing the modules that are available here and a description 2. Information that is generally available – in other words, affects all analog module[...]

  • Страница 218

    Analog Modules 5-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Chapter Overview Section Description Page 5.1 Module Overview 5-3 5.2 Sequence of Steps from Choosing to Commissioning the Analog Modules 5-6 5.3 Analog V alue Representation 5-7 5.4 Setting the Measuring Method and Measuring Ranges of the Analog Input C[...]

  • Страница 219

    Analog Modules 5-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.1 Module Overview Introduction The following tables summarize the most important characteristics of the analog modules. This overview is intended to make it easy to choose the suitable module for your task. T able 5-1 Analog Input Modules: Characterist[...]

  • Страница 220

    Analog Modules 5-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-1 Analog Input Modules: Characteristics at a Glance, continued Module SM 431; AI 8 16 Bit (-7KF00-) SM 431; AI 8 RTD 16 Bit (-7KF10-) SM 431; AI 16 16 Bit (-7QH00-) SM 431; AI 13 16 Bit (-0HH0-) SM 431; AI 8 14 Bit (-1KF20-) SM 431; AI 8 14 Bit [...]

  • Страница 221

    Analog Modules 5-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-2 Analog Output Modules: Characteristics at a Glance Module SM 432; AO 8 13 Bit (-1HF00-) Characteristics Max. permissible common mode voltage Between the channels and the channels against M ANA 3 VDC Special Features –[...]

  • Страница 222

    Analog Modules 5-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.2 Sequence of Steps from Choosing to Commissioning the Analog Modules Introduction The following table contains the tasks that you have to perform one after the other to commission analog modules successfully . The sequence of steps is a suggestion, bu[...]

  • Страница 223

    Analog Modules 5-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.3 Analog V alue Representation Introduction This section describes the analog values for all the measuring ranges and output ranges which you can use with the analog modules. Converting Analog V alues Analog input modules convert the analog process sig[...]

  • Страница 224

    Analog Modules 5-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Example In the following example you can see how the positions not padded with “0” are written for low resolution. T able 5-4 Example: Bit Pattern of a 16-Bit and a 13-Bit Analog V alue Resolution Analog V alue Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1[...]

  • Страница 225

    Analog Modules 5-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-5 Possible Resolutions of the Analog V alues Resolution in Bits Units Analog V alue in Bits Decimal Hexadecimal High-Order Byte Low-Order Byte 9 128 80 H 0 0 0 0 0 0 0 0 1 x x x x x x x 10 64 40 H 0 0 0 0 0 0 0 0 0 1 x x x x x x 11 32 20 H 0 0 0[...]

  • Страница 226

    Analog Modules 5-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Binary Representation of the Input Ranges The input ranges shown in T ables 5-6 to 5-8 are defined in two’s complement representation: T able 5-6 Bipolar Input Ranges Units Measured V alue Data Word Range V a l ue in % 2 15 2 14 2 13 2 12 2 11 2 10 2 [...]

  • Страница 227

    Analog Modules 5-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-8 Life-Zero Input Ranges Units Measured V alue Data Word Range V a l ue in % 2 15 2 14 2 13 2 12 2 11 2 10 2 9 2 8 2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0 w 32767 w 1 18.515 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Over- flow 3251 1 1 17.589 0 1 1 1 1 1 1 0 1 [...]

  • Страница 228

    Analog Modules 5-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-10 Analog V alue Representation in the V oltage Measuring Ranges ± 500 mV to ± 25 mV System V oltage Measuring Range Dec. Hex. ± 500 mV ± 250 mV ± 80 mV ± 50 mV ± 25 mV 1 18.515% 32767 7FFF 592.6 mV 296.3 mV 94.8 mV 59.3 mV 29.6 mV Overf[...]

  • Страница 229

    Analog Modules 5-13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog V alue Representation in Current Measuring Ranges T able 5-12 Analog V alue Representation in the Current Measuring Ranges ± 20 mA to ± 3.2 mA System Current Measuring Range Dec. Hex. ± 20 mA ± 10 mA ± 5 mA ± 3.2 mA 1 18.515% 32767 7FFF 23.[...]

  • Страница 230

    Analog Modules 5-14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-14 Analog V alue Representation in Current Measuring Ranges 4 to 20 mA System Current Measuring Range Dec. Hex. 4 to 20 mA 1 18.515% 32767 7FFF 22.96 mA Overflow 1 17.593% 32512 7F00 1 17.589% 3251 1 7EFF 22.81 mA Overrange 27649 6C01 100.000% [...]

  • Страница 231

    Analog Modules 5-15 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog V alue Representation for Resistance Thermometers Pt x00 Standard T able 5-16 Analog V alue Representation for Resistance Thermometers Pt 100, 200, 500,1000 Pt x00 Standard Units Pt x00 Standard Units Pt x00 Standard Units S tan d ar d in 5 C (1 [...]

  • Страница 232

    Analog Modules 5-16 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog V alue Representation for Resistance Thermometers Ni x00 Standard T able 5-18 Analog V alue Representation for Resistance Thermometers Ni100, 120, 200, 500, 1000 Ni x00 Standard Units Ni x00 Standard Units Ni x00 Standard Units S tan d ar d in 5 [...]

  • Страница 233

    Analog Modules 5-17 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog V alue Representation for Resistance Thermometers Cu 10 Standard T able 5-20 Analog V alue Representation for Resistance Thermometers Cu 10 Cu 10 Standard Units Cu 10 Standard Units Cu 10 Standard Units S tan d ar d in 5 C (1 Digit = 0.01 5 C) De[...]

  • Страница 234

    Analog Modules 5-18 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog V alue Representation for Themocouple T ype B T able 5-22 Analog V alue Representation for Thermocouple T ype B T ype B Units T ype B Units T ype B Units T ype B in 5 C Deci- mal Hexa- deci- mal T ype B in 5 F Deci- mal Hexa- deci- mal T ype B in[...]

  • Страница 235

    Analog Modules 5-19 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog V alue Representation for Thermocouple T ype J T able 5-24 Analog V alue Representation for Thermocouple T ype J T ype J Units T ype J Units T ype J Units T ype J in 5 C Deci- mal Hexade- cimal T ype J in 5 F Deci- mal Hexa- deci- mal T ype J in [...]

  • Страница 236

    Analog Modules 5-20 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog V alue Representation for Thermocouple T ype L T able 5-26 Analog V alue Representation for Thermocouple T ype L T ype L Units T ype L Units T ype L Units T ype L in 5 C Decimal Hexa- decimal T ype L in 5 F Deci- mal Hexa- deci- mal T ype L in K [...]

  • Страница 237

    Analog Modules 5-21 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog V alue Representation for Thermocouple T ypes R, S T able 5-28 Analog V alue Representation for Thermocouple T ypes R, S T ypes R S Units T ypes R Units T ypes R Units T ypes R, S in 5 C Deci- mal Hexa- deci- mal T ypes R, S in 5 F Deci- mal Hexa[...]

  • Страница 238

    Analog Modules 5-22 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog V alue Representation for Thermocouple T ype U T able 5-30 Analog V alue Representation for Thermocouple T ype U T ype U Units T ype U Units T ype U Units T ype U in 5 C Deci- mal Hexa- deci- mal T ype U in 5 F Deci- mal Hexa- deci- mal T ype U i[...]

  • Страница 239

    Analog Modules 5-23 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.3.2 Analog V alue Representation for Analog Output Channels Introduction The tables in this chapter contain the analog value representation for output channels of the analog output modules. The values in the tables apply to all modules with the corres[...]

  • Страница 240

    Analog Modules 5-24 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-32 Unipolar Output Ranges Units Output V al e in Data Word Range V alue in % 2 1 5 2 1 4 2 1 3 2 1 2 2 11 2 1 0 2 9 2 8 2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0 w 32512 0% 0 1 1 1 1 1 1 1 x x x x x x x x Overflow 3251 1 1 17.589 0 1 1 1 1 1 1 0 1 1 1 1 [...]

  • Страница 241

    Analog Modules 5-25 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-33 Life-Zero Output Ranges Units Output V al e in % Data Word Range V alue in % 2 1 5 2 1 4 2 1 3 2 1 2 2 11 2 1 0 2 9 2 8 2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0 w 32512 0 % 0 1 1 1 1 1 1 1 x x x x x x x x Over- flow 3251 1 1 17.589 0 1 1 1 1 1 1 0 1 [...]

  • Страница 242

    Analog Modules 5-26 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog V alue Representation in V oltage Output Ranges T able 5-34 Analog V alue Representation in Output Range ±( 10 V System V oltage Output Range Dec. Hex . ±( 10 V 1 18.5149% 32767 7FFF 0.00 V Overflow , off circuit and deenergized 32512 7F00 g 1 [...]

  • Страница 243

    Analog Modules 5-27 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog V alue Representation in Current Output Ranges T able 5-36 Analog V alue Representation in Output Range ±( 20 mA System Current Output Range Dec. Hex . ±( 20 mA 1 18.5149% 32767 7FFF 0.00 mA Overflow , off circuit and deenergized 32512 7F00 1 1[...]

  • Страница 244

    Analog Modules 5-28 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.4 Setting the Measuring Method and Measuring Ranges of the Analog Input Channels T wo Procedures There are two procedures for setting the measuring method and the measuring ranges of the analog input channels of the analog modules: • With a measurin[...]

  • Страница 245

    Analog Modules 5-29 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Replugging Measuring Range Modules If you want to replug a measuring range module, perform the following steps: 1. Use a screwdriver to ease the measuring range module out of the analog input module. Figure 5-1 Levering the Measuring Range Module out of[...]

  • Страница 246

    Analog Modules 5-30 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 2. Insert the measuring range module (correctly positioned (1)) into the analog input module. The measuring range selected is the one that points to marker point on module (2). 1 2 Figure 5-2 Inserting the Measuring Range Module into the Analog Input Mo[...]

  • Страница 247

    Analog Modules 5-31 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.5 Behavior of the Analog Modules Introduction In this section, you will find information on: • How the analog input and output values depend on the operating modes of the CPU and the supply voltage of the analog module • The behavior of the analog[...]

  • Страница 248

    Analog Modules 5-32 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Behavior on Failure of the Supply V oltage Failure of the load power supply L+ of the diagnostics-capable analog module is indicated in the case of parameterized two-wire transmitters by the EXTF LED on the module. Furthermore, this information is made [...]

  • Страница 249

    Analog Modules 5-33 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Effect of Range of V alues on the Analog Output Module The behavior of the analog modules depends on where the output values lie within the value range. T able 5-40 Behavior of the Analog Output Modules as a Function of the Position of the Analog V alue[...]

  • Страница 250

    Analog Modules 5-34 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Example of Determination of the Output Error of a Module An analog output module SM 432; AO 8 13 Bit is being used for voltage output. The output range “ " 10 V” is used. The module is operating at an ambient temperature of 30 ° C. The operati[...]

  • Страница 251

    Analog Modules 5-35 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.6 Conversion, Cycle, Setting and Response Time of Analog Modules Conversion Time of Analog Input Channels The conversion time consists of a basic conversion time and additional processing times of the module for: • Resistance test • Wire-break mon[...]

  • Страница 252

    Analog Modules 5-36 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Basic Execution Time of the Analog Input Channels The basic execution time corresponds to the cycle time for all the enabled channels. Setting the Smoothing of Analog V alues Y ou can set the smoothing of the analog values in STEP 7 for some analog inpu[...]

  • Страница 253

    Analog Modules 5-37 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Example The following figure shows the number of module cycles for a step response after which the smoothed analog value is approximately 100% applied, as a function of the smoothing that has been set. The figure applies to every change of signal at the[...]

  • Страница 254

    Analog Modules 5-38 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Basic Execution Time of the Analog Output Channels The basic execution time corresponds to the cycle time for all the enabled channels. Tip Y ou should disable any analog channels that are not being used to reduce the scan time in STEP 7 . Overview of t[...]

  • Страница 255

    Analog Modules 5-39 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.7 Analog Module Parameter Assignment Introduction Analog modules can have different characteristics. Y ou can set the characteristics of the modules by means of parameter assignment. T ools for Parameter Assignment Y ou assign parameters to analog mod[...]

  • Страница 256

    Analog Modules 5-40 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.7.1 Parameters of the Analog Input Modules The analog input modules use a subset of the parameters and ranges of values listed in the table below , depending on the functionality . Refer to the section on the module concerned, starting from Section 5.[...]

  • Страница 257

    Analog Modules 5-41 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-42 Parameters of the Analog Input Modules, continued Parameter Scope Parameter T ype Default 2) V alue Range Measurement • Measuring type Disabled U V oltage 4DMU Current (four-wire transmitter) 2DMU Current (two-wire transmitter) R-4L Resist[...]

  • Страница 258

    Analog Modules 5-42 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.7.2 Parameters of the Analog Output Modules The analog output modules use a subset of the parameters and ranges of values listed in the table below , depending on the functionality . Refer to the section on the module concerned, starting from Section [...]

  • Страница 259

    Analog Modules 5-43 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.8 Connecting Sensors to Analog Inputs Introduction Y ou can connect different sensors to the analog input modules depending on the measuring method; voltage and current sensors, and resistors. This section contains general information that is generall[...]

  • Страница 260

    Analog Modules 5-44 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Abbreviations and Mnemonics Used in the Figures Below The abbreviations and mnemonics used in the figures below have the following meanings: M +: Measuring line (positive) M –: Measuring line (negative) M ANA : Reference potential of the analog measur[...]

  • Страница 261

    Analog Modules 5-45 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Non-Isolated Sensors The non-isolated sensors are connected with the local ground potential (local ground). When using non-isolated sensors, you must connect M ANA to chassis ground. Connecting Non-Isolated Sensors Caused by local conditions or interfer[...]

  • Страница 262

    Analog Modules 5-46 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.9 Connecting V oltage Sensors Note The necessary connecting cables, which result from the potential connection of the analog input module and the sensors, are not drawn in the figures shown below . In other words, you must continue to take note of and[...]

  • Страница 263

    Analog Modules 5-47 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.10 Connecting Current Sensors Note The necessary connecting cables, which result from the potential connection of the analog input module and the sensors, are not drawn in the figures shown below . In other words, you must continue to take note of and[...]

  • Страница 264

    Analog Modules 5-48 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Connecting T wo-Wire T ransmitters +24 V Sensor , for example, pressure gauge + – L + M+ M - M+ M - M T wo-wire transmitter T wo-wire transmitter + – M P P M ANA * Connection required in the case of modules with M ANA * Figure 5-10 Connecting T wo-W[...]

  • Страница 265

    Analog Modules 5-49 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Connecting Four-Wire T ransmitters M+ M– M+ M– M ANA Sensor , for example, pressure gauge + – Four-wire transmitter + – U H * Connection required in the case of modules with M ANA P P * * Figure 5-12 Connecting Four-Wire Transmitters to an AI SM[...]

  • Страница 266

    Analog Modules 5-50 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.1 1 Connecting Resistance Thermometers and Resistors Note The necessary connecting cables, which result from the potential connection of the analog input module and the sensors, are not drawn in the figures shown below . In other words, you must conti[...]

  • Страница 267

    Analog Modules 5-51 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Four-Conductor Connection of a Resistance Thermometer The voltage generated at the resistance thermometer is measured via the M + and M – terminals. When you connect, watch out for the polarity of the connected cable (connect I C + and M+ as well as I[...]

  • Страница 268

    Analog Modules 5-52 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Three-Conductor Connection of a Resistance Thermometer During three-conductor connection to modules with 4 terminals per resistance thermometer , you must set up a jumper between M– and I C – and SE– and AGND (see Figure 5-15). The module compensa[...]

  • Страница 269

    Analog Modules 5-53 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.12 Connecting Thermocouples Design of Thermocouples A thermocouple consists of a pair of sensors and the necessary installation and connecting parts. The thermocouple consists of two wires of dissimilar metals or metal alloys soldered or welded togeth[...]

  • Страница 270

    Analog Modules 5-54 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Compensation of the Reference Junction T emperature There are several options for you to choose from for acquiring the reference junction temperature in order to obtain an absolute temperature value from the difference in temperature between the referen[...]

  • Страница 271

    Analog Modules 5-55 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Theory of Operation of Internal Compensation With internal compensation, you can establish the reference point across the terminals of the analog input modules. In this case, you must run the compensating lines right up to the analog module. The interna[...]

  • Страница 272

    Analog Modules 5-56 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Connection of Thermocouples without Compensation or Using the Reference T emperature V alue Connect the thermocouples to the inputs of the module, either directly or by means of compensating lines. Each channel can use a thermocouple type supported by t[...]

  • Страница 273

    Analog Modules 5-57 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Recommended Compensating Box We recommend you to use a comparison point (with integrated power supply unit) from Siemens as a compensating box. Y ou will find the necessary ordering data in the table below . T able 5-45 Ordering Data of the Comparison P[...]

  • Страница 274

    Analog Modules 5-58 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Connecting Thermocouples and Resistance Thermometers Connect the resistance thermometer to channel 0 of the module. Make sure that you parameterize the “RTD on Channel 0“ reference junction in STEP 7 for each channel that has a thermocouple connecte[...]

  • Страница 275

    Analog Modules 5-59 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.13 Connecting Loads/Actuators to Analog Outputs Introduction Y ou can use the analog output modules to supply loads and actuators with current and voltage. This section contains general information that is generally applicable to all the connection op[...]

  • Страница 276

    Analog Modules 5-60 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.14 Connecting Loads/Actuators to V oltage Outputs Connecting Loads to a V oltage Output Connecting loads to a voltage output is possible both in a four-conductor and a two-conductor connection. Note The necessary connecting cables, which result from t[...]

  • Страница 277

    Analog Modules 5-61 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 +24 V L + Q V S+ S– M ANA 0 V M U ISO Chassis ground R L Figure 5-21 Connecting Loads to a V oltage Output of an Isolated AO over a Four-Conductor Connection T wo-Conductor Connection of Loads to a V oltage Output In the case of a two-conductor connec[...]

  • Страница 278

    Analog Modules 5-62 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.15 Connecting Loads/Actuators to Current Outputs Note The necessary connecting cables, which result from the potential connection of the analog output module, are not drawn in the figures shown below . In other words, you must continue to take note of[...]

  • Страница 279

    Analog Modules 5-63 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.16 Diagnostics of the Analog Modules Programmable and Non-Programmable Diagnostic Messages In diagnostics, we make a distinction between programmable and non-programmable diagnostic messages. Y ou obtain programmable diagnostic messages only if you ha[...]

  • Страница 280

    Analog Modules 5-64 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Diagnostic Messages of the Analog Input Modules The table below gives an overview of the diagnostic messages for the analog input modules with diagnostics capability . Y ou can find out which diagnostic messages are possible with which modules in the Ap[...]

  • Страница 281

    Analog Modules 5-65 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Note A prerequisite for detecting the errors indicated by programmable diagnostic messages is that you must have assigned parameters to the analog module accordingly in STEP 7 . Causes of Errors and Remedial Measures for Analog Input Modules T able 5-47[...]

  • Страница 282

    Analog Modules 5-66 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-47 Diagnostics Messages of the Analog Input Modules, Causes of Errors and Remedial Measures, continued Diagnostics Message Remedy Possible Error Cause EPROM error The module is defective Replace module RAM error ADC/DAC error Hardware interrupt[...]

  • Страница 283

    Analog Modules 5-67 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.17 Analog Module Interrupts Introduction In this Section, the interrupt behavior of the analog modules is described. The following interrupts exist: • Diagnostic Interrupt • Hardware interrupt Note that not all analog modules have interrupt capabi[...]

  • Страница 284

    Analog Modules 5-68 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Hardware Interrupt with T rigger “Upper or Lower Limit Exceeded” Define a working range by setting parameters for an upper and lower limit value. If the process signal (for example, the temperature) leaves this working range, the module triggers a h[...]

  • Страница 285

    Analog Modules 5-69 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Hardware Interrupt on T rigger “Reached End of Scan Cycle” By parameterizing the hardware interrupt a the end of the scan cycle, you have the option of synchronizing a process with the scan cycle of the analog input module. A scan cycle includes the[...]

  • Страница 286

    Analog Modules 5-70 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.18 Analog Input Module SM 431; AI 8 13 Bit; (6ES7431-1KF00-0AB0) Characteristics The analog input module SM 431; AI 8 13 Bit has the following features: • 8 inputs for voltage/current measurement • 4 inputs for resistance measurement • Unlimited[...]

  • Страница 287

    Analog Modules 5-71 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Block Diagram of the SM 431; AI 8 13 Bit A D +5V 0V CH1 CH7 CH0 +5V –5V 0V Suppressor circuit, current jumpering MV0+ MI0+ MI0+ M0– CH1 CH7 F_CON Bus control M Bus S7-400 ANA Front connector monitoring Bus S7-400 Bus S7-400 Figure 5-25 Block Diagram[...]

  • Страница 288

    Analog Modules 5-72 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram of the SM 431; AI 8 13 Bit M ANA V A V A V oltage measurement Current measure- ment Resistance mea- surement MV0+ MV0+ M0+ M0– M1+ M1– M2+ M2– M3+ M3– M0– MV1+ M1– MV2+ M2– MV3+ M3– M MV4+ M4– MV5+ M5– MV[...]

  • Страница 289

    Analog Modules 5-73 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 431; AI 8 13 Bit Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 500 g Data for Specific Module Number of inputs [...]

  • Страница 290

    Analog Modules 5-74 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Status, Interrupts, Diagnostics Interrupts None Diagnostic functions None Substitute value can be applied No Data for Selecting a Sensor Input range (rated values)/input resistance • V oltage " 1 V/200 k  " 10 V/200 k  1 V to 5 V/200 k[...]

  • Страница 291

    Analog Modules 5-75 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.18.2 Measuring Methods and Measuring Ranges of the SM 431; AI 8 13 Bit Measuring Methods Y ou can set the following measuring methods for the input channels: • V oltage measurement • Current measurement • Resistance test Y ou perform the setting[...]

  • Страница 292

    Analog Modules 5-76 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Measuring Ranges Y ou set the measuring ranges by means of the “Measuring Range” parameter in STEP 7 . T able 5-50 Measuring Ranges of the SM 431; AI 8 x 13 Bit Method Selected Measuring Range Description U: V oltage ±( 1 V 1 to 5 V ±( 10 V Y ou w[...]

  • Страница 293

    Analog Modules 5-77 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.19 Analog Input Module SM 431; AI 8 14 Bit; (6ES7 431-1KF10-0AB0) Characteristics The analog input module SM 431; AI 8  14 Bit has the following features: • 8 inputs for voltage/current measurement • 4 inputs for resistance and temperature meas[...]

  • Страница 294

    Analog Modules 5-78 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram of the SM 431; AI 8 14 Bit Thermocouples V oltage measurement Current measurement Resistance measurement Resistance thermometer M1+ M2– M3– M4– M5– M6– M7– CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7 L+ V V V M Tr Tr L+ M0+ [...]

  • Страница 295

    Analog Modules 5-79 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 431; AI 8 14 Bit Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 500 g Data for Specific Module Number of inputs [...]

  • Страница 296

    Analog Modules 5-80 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Suppression of Interference, Limits of Error Interference voltage suppression for f = nx (f1 " 1%), (f1 = interference frequency) n = 1, 2, ... • Common-mode interference (U CM < 120 V ss ) > 100 dB • Series-mode interference (peak value [...]

  • Страница 297

    Analog Modules 5-81 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Basic error (operational limit at 25 ° C, referred to input range) • V oltage input – " 80 mV – " 250 mV – " 500 mV – " 1 V – " 2.5 V – " 5 V – 1 V to 5 V – " 10 V " 0.17% " 0.15% " 0.[...]

  • Страница 298

    Analog Modules 5-82 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Status, Interrupts, Diagnostics Interrupts None Diagnostic functions None Substitute value can be applied No Data for Selecting a Sensor Input range (rated values)/Input resistance • V oltage " 80 mV/1 M  " 250 mV/1 M  " 500 mV/1 [...]

  • Страница 299

    Analog Modules 5-83 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.19.1 Commissioning the SM 431; AI 8 14 Bit Y ou set the mode of operation of the SM 431; AI 8 14 Bit by means of measuring range modules on the module and in STEP 7 . Measuring Range Module A measuring range module of the module matches two channels a[...]

  • Страница 300

    Analog Modules 5-84 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-51 Parameters of the SM 431; AI 8 14 Bit, continued Parameter Scope Parameter T ype Default 1 V alue Range • Interference suppression 60 Hz; 50 Hz 50 Hz Static Channel • Smoothing None Low Average High None Static Channel • Ref. junction [...]

  • Страница 301

    Analog Modules 5-85 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.19.2 Measuring Methods and Measuring Ranges of the SM 431; AI 8 14 Bit Measuring Methods Y ou can set the following measuring methods for the input channels: • V oltage measurement • Current measurement • Resistance test • T emperature measure[...]

  • Страница 302

    Analog Modules 5-86 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Wiring for Resistance and T emperature Measurement The following conditions apply when measuring the resistance and temperature with the SM 431; AI 8 x 1 4 Bi t: T able 5-53 Channels for Resistance and T emperature Measurement with the SM 431; AI 8 14 B[...]

  • Страница 303

    Analog Modules 5-87 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Measuring Ranges Y ou set the measuring ranges by means of the measuring range modules on the module and the “Measuring T ype” parameter in STEP 7 . T able 5-55 Measuring Ranges of the SM 431; AI 8 x 14 Bit Method Selected Measuring Range (T ype of [...]

  • Страница 304

    Analog Modules 5-88 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-55 Measuring Ranges of the SM 431; AI 8 x 14 Bit, continued Method Selected Description Measuring Range Module Setting Measuring Range (T ype of Sensor) TC-L: Thermocouple (linear) (temperature measurement) T ype B T ype N T ype E T ype R T ype[...]

  • Страница 305

    Analog Modules 5-89 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Wire Break Check for T emperature or Resistance Measurement The wire break check is intended primarily for temperature measurements (TC, RTD) or resistance measurements. Always parameterize the wire break check in these cases as this ensures that, in th[...]

  • Страница 306

    Analog Modules 5-90 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.20 Analog Input Module SM 431; AI 8 14 Bit; (6ES7431-1KF20-0AB0) Characteristics The analog input module SM 431; AI 8 14 Bit has the following features: • Rapid A/D changeover , therefore particularly suitable for highly dynamic processes • 8 inpu[...]

  • Страница 307

    Analog Modules 5-91 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram of the SM 431; AI 8 14 Bit V oltage measurement Current measurement Resistance measurement M1+ M2– M3– M4– M5– M6– M7– CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7 L+ V A A M Tr Tr L+ M0+ M0– M1– M2+ M3+ M4+ M5+ M6+ M7+ M[...]

  • Страница 308

    Analog Modules 5-92 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 431; AI 8 14 Bit Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 500 g Data for Specific Module Number of inputs [...]

  • Страница 309

    Analog Modules 5-93 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Suppression of interference, Limits of Error Interference voltage suppression parameterized for f = nx (f1 " 1%), (f1 = interference frequency) n = 1, 2 , ... filter 400/60/50 Hz • Common-mode interference (U CM < 1 1 V ss ) > 80 db • Ser[...]

  • Страница 310

    Analog Modules 5-94 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.20.1 Commissioning the SM 431; AI 8 14 Bit Y ou set the mode of operation of the SM 431; AI 8 14 Bit by means of measuring range modules on the module and in STEP 7 . Measuring Range Modules A measuring range module of the module matches two channels [...]

  • Страница 311

    Analog Modules 5-95 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Smoothing of the Measured V alues Y ou will find information that is generally applicable to the smoothing of analog values in Section 5.6. Y ou can only set strong smoothing for the SM 431; AI 8 14 Bit. The module cycle time is a constant, irrespective[...]

  • Страница 312

    Analog Modules 5-96 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Step Response with Strong Smoothing The following figure illustrates the contents of T able 5-57. It shows the filter settling time after which, in the case of a step response, the smoothed analog value is applied to almost 100%, depending on the interf[...]

  • Страница 313

    Analog Modules 5-97 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Circuit V ariants of the Channels T wo channels are set in each case with the measuring range module. There are therefore restrictions as regards the measuring method for the adjacent channels 0/1, 2/3, 4/5 and 6/7, as shown in the following table: T ab[...]

  • Страница 314

    Analog Modules 5-98 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Unused Channels Unused channels can usually be left open. Put the measuring range modules in position “B”. Y ou can improve the noise immunity of the module in a measuring environment with serious interference by connecting M– and M ANA . Measurin[...]

  • Страница 315

    Analog Modules 5-99 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.21 Analog Input Module SM 431; AI 16 13 Bit; (6ES7431-0HH00-0AB0) Characteristics The analog input module SM 431; AI 13  16 Bit has the following features: • 16 inputs for voltage/current measurement • Unlimited measuring range selection • 13[...]

  • Страница 316

    Analog Modules 5-100 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Block Diagram of the SM 431; AI 16 x 13 Bit Tr Tr Tr Tr Tr Tr Tr Tr * *V oltage/current sensor and M must be connected to the chassis ground of the rack *V oltage/current sensor and M must be connected to the chassis ground of the rack T r = T ransduce[...]

  • Страница 317

    Analog Modules 5-101 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram of the SM 431; AI 16 x 13 Bit V oltage measurement Current measurement M1+ M2– M3– M4– M5– M6– M7– CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7 L+ M0+ M0– M1– M2+ M3+ M4+ M5+ M6+ M7+ M M8– M9– M8+ M9+ M10– M1 1– [...]

  • Страница 318

    Analog Modules 5-102 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 431; AI 16 x 13 Bit Dimensions and W eight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 500 g Data for Specific Module Number of inputs • Shielded 16 Max. 200 m V oltages, Currents, Potentials Rated [...]

  • Страница 319

    Analog Modules 5-103 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Data for Selecting a Sensor Input range (rated values)/Input resistance • V oltage " 1 V/10 M  " 10 V/100 M  1 V to 5 V  100 M  • Current " 20 mA/50  4 mA to 20 mA  50  Maximum input voltage for voltage input (de[...]

  • Страница 320

    Analog Modules 5-104 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.21.1 Commissioning the SM 431; AI 16 13 Bit Y ou set the mode of operation of the SM 431; AI 16 13 Bit by means of measuring range modules on the module and in STEP 7 . Measurement Range Modules A measuring range module of the module matches two cons[...]

  • Страница 321

    Analog Modules 5-105 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.21.2 Measuring Methods and Measuring Ranges of the SM 431; AI 16 13 Bit Measuring Methods Y ou can set the following measuring methods for the input channels: • V oltage measurement • Current measurement Y ou specify the setting by means of the m[...]

  • Страница 322

    Analog Modules 5-106 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Unused Channels Unused channels can usually be left open. Put the measuring range modules in position “B”. Y ou can improve the noise immunity of the module in a measuring environment with serious interference by connecting M– and chassis ground.[...]

  • Страница 323

    Analog Modules 5-107 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.22 Analog Input Module SM 431; AI 16 16 Bit; (6ES7431-7QH00-0AB0) Characteristics The analog input module SM 431; AI 16  16 Bit has the following features: • 16 inputs for voltage/current and temperature measurement • 8 inputs for resistance m[...]

  • Страница 324

    Analog Modules 5-108 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Block Diagram of the SM 431; AI 16 16 Bit Bus S7-400 Bus control A D CH0 CH1 + 15 V + 5 V 0 V –15 V + 5 V 0 V I const Diagnostics in L+ loop L + M PGA Multiplexer Opto relay CH14 CH15 Meas. range Meas. range module 0 module 7 Signal jumpering Bus S7-[...]

  • Страница 325

    Analog Modules 5-109 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram of the SM 431; AI 16 16 Bit Thermocouples V oltage measurement Current measurement Resistance measurement Resistance thermometer M1+ M2– M3– M4– M5– M6– M7– CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7 L+ V A A M Tr Tr L+ M0[...]

  • Страница 326

    Analog Modules 5-1 10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 431; AI 16 16 Bit Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 500 g Data for Specific Module Number of inpu[...]

  • Страница 327

    Analog Modules 5-1 1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Suppression of Interference, Limits of Error Interference voltage suppression for f = nx (f1 " 1%), (f1 = interference frequency) n = 1, 2, ... • Common-mode interference (U CM < 120 V ss ) > 100 dB • Series-mode interference (peak val[...]

  • Страница 328

    Analog Modules 5-1 12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Basic error (operational limit at 25 ° C, referred to input range) • V oltage input – " 25 mV – " 50 mV – " 80 mV – " 250 mV – " 500 mV – " 1 V – " 2.5 V – " 5 V – 1 V to 5 V – "+ 10 [...]

  • Страница 329

    Analog Modules 5-1 13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Status, Interrupts, Diagnostics Interrupts • Hardware interrupt Parameters can be assigned • Hardware interrupt when limit has been exceeded Parameters can be assigned • Diagnostic Interrupt Parameters can be assigned Diagnostic functions • Gr[...]

  • Страница 330

    Analog Modules 5-1 14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.22.1 Commissioning the SM 431; AI 16 16 Bit Y ou set the mode of operation of the SM 431; AI 16 16 Bit by means of measuring range modules on the module and in STEP 7 . Measuring Range Module A measuring range module of the module matches two channe[...]

  • Страница 331

    Analog Modules 5-1 15 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-64 Parameters of the SM 431; AI 16 16 Bit, continued Parameter Scope Parameter T ype Default 2) V alue Range Measurement • Measuring type Disabled U V oltage 4DMU Current (4-wire transmitter) 2DMU Current (two-wire transmitter) R-4L Resisto[...]

  • Страница 332

    Analog Modules 5-1 16 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Smoothing of the Measured V alues Y ou fill find information that is generally applicable to the smoothing of analog values in Section 5.6. The following figure indicates for the module the number of module cycles after which, in the case of a step re[...]

  • Страница 333

    Analog Modules 5-1 17 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.22.2 Measuring Methods and Measuring Ranges of the SM 431; AI 16 16 Bit Measuring Methods Y ou can set the following measuring methods for the input channels: • V oltage measurement • Current measurement • Resistance test • T emperature meas[...]

  • Страница 334

    Analog Modules 5-1 18 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Example If you have select “current (two-wire transmitter)” for channel 6, you can only disable the measuring method or set “current (two-wire transmitter)” for channel 7. Circuit for Resistance and T emperature Measurement The following condi[...]

  • Страница 335

    Analog Modules 5-1 19 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Unused Channels Unused channels can usually be left open. Put the measuring range modules in position “A”. Y ou can improve the noise immunity of the module in a measuring environment with serious interference by short-circuiting the channels. Dis[...]

  • Страница 336

    Analog Modules 5-120 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-69 Measuring Ranges of the SM 431; AI 16 x 16 Bit, continued Method Selected Description Measuring Range Module Setting Measuring Range (T ype of Sensor) R-3L: Resistor (three-conductor terminal) 300  600  6000   max. 5000  A[...]

  • Страница 337

    Analog Modules 5-121 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Wire Break Check The wire break check is intended primarily for temperature measurements (TC, RTD) or resistance measurements. Always parameterize the wire break check in these cases as this ensures that in the event of a wire break the measured value [...]

  • Страница 338

    Analog Modules 5-122 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.23 Analog Input Module SM 431; AI 8 RTD 16 Bit; (6ES7 431-7KF10-0AB0) Characteristics The analog input module SM 431; AI 8 RTD 16 Bit has the following features: • 8 differential inputs for the resistance thermometer • Resistance thermometer can [...]

  • Страница 339

    Analog Modules 5-123 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Block Diagram of the SM 431; AI 8 RTD 16 Bit Backplane bus interface Bus S7-400 SO+0 SE+0 SE–0 AGND SO+7 SE+7 SE–7 AGND CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7 A/D converter Isolation Internal voltage supply Figure 5-38 Block Diagram of the SM 431; AI 8 x [...]

  • Страница 340

    Analog Modules 5-124 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram of the SM 431; AI 8 RTD 16 Bit SO0 CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7 SE+0 SE–0 AGND 29 30 31 32 33 34 35 36 37 39 40 41 42 43 44 45 46 47 48 38 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 INTF[...]

  • Страница 341

    Analog Modules 5-125 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 431; AI 8 RTD 16 Bit Dimensions and W eight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 650 g Data for Specific Module Number of inputs • For resistance-type sensor 8 4 Length of cable • Shielded [...]

  • Страница 342

    Analog Modules 5-126 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.23.1 Commissioning the SM 431; AI 8 RTD 16 Bit Y ou set the mode of operation of the SM 431; AI 8 RTD 16 Bit in STEP 7 . Parameters Y ou will find a description of the general procedure for assigning parameters to analog modules in Section 5.7. An ov[...]

  • Страница 343

    Analog Modules 5-127 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-71 Parameters of the SM 431; AI 8 RTD 16 Bit, continued Parameter Scope Parameter T ype Default 2) V alue Range • Interference suppression 60 Hz; 50 Hz; none 60 Hz • Smoothing None Low Average High None Static Channel 1) If you use the mod[...]

  • Страница 344

    Analog Modules 5-128 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Displaying Parameter Assignment Errors The SM 431; AI 8 RTD 16 Bit is capable of diagnostics. Below you will find an overview of the displays that are possible for modules with parameter assignment errors. T able 5-72 Diagnostic Information of the SM 4[...]

  • Страница 345

    Analog Modules 5-129 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.23.2 Measuring Methods and Measuring Ranges of the SM 431; AI 8 RTD 16 Bit Measuring Methods As the measuring method for the input channels, you can set the temperature measurement. Unused Channels Disable the “Measuring T ype” parameter for unus[...]

  • Страница 346

    Analog Modules 5-130 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.24 Analog Input Module SM 431; AI 8 16 Bit; (6ES7431-7KF00-0AB0) Characteristics The analog input module SM 431; AI 8  16 Bit has the following features: • 8 isolated differential inputs for voltage/current/temperature measurement • Unlimited [...]

  • Страница 347

    Analog Modules 5-131 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Block Diagram of the SM 431; AI 8 16 Bit Backplane bus interface Bus S7-400 M0+ M0+ R0 M0– CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH0 A/D converter Internal supply Figure 5-41 Block Diagram of the SM 431; AI 8 x 16 Bit Note An external protective network is req[...]

  • Страница 348

    Analog Modules 5-132 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram of the SM 431; AI 8 16 Bit R0 CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7 M0+ M0+ M0– INTF EXTF Word 0 Word 2 Word 4 Word 6 Word 1 Word 3 Word 5 Word 7 V A V A Tr Tr R1 M1+ M1+ M1– R2 M2+ M2+ M2– R3 M3+ M3+ M3– R4 M4+ M4+ M4–[...]

  • Страница 349

    Analog Modules 5-133 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 431; AI 8 16 Bit Dimensions and W eight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 650 g Data for Specific Module Number of inputs 8 Length of cable • Shielded 200 m V oltages, Currents, Potentials[...]

  • Страница 350

    Analog Modules 5-134 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Operational limit (in the entire temperature range, with reference to the input range) • V oltage input " 0.3 % • Current input " 0.5 % • Thermocouple T ype B " 3.5  C T ype N " 2.7  C T ype E " 1.8  C T ype R &q[...]

  • Страница 351

    Analog Modules 5-135 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.24.1 Commissioning the SM 431; AI 8 16 Bit Y ou set the mode of operation of the SM 431; AI 8 16 Bit in STEP 7 . Parameter Y ou will find a description of the general procedure for assigning parameters to analog modules in Section 5.7. An overview of[...]

  • Страница 352

    Analog Modules 5-136 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 5-74 Parameters of the SM 431; AI 8 16 Bit, continued Parameter Scope Parameter T ype Default 2) V alue Range • Smoothing None Low Average High None • Reference junction (reference to the cold junction) None Internal Reference temperature va[...]

  • Страница 353

    Analog Modules 5-137 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Step Response at an Interference Frequency Suppression of 10 Hz 100 0 Smoo- thing: None: Low: Average: High: Response time in ms Signal variation in percent Step response for any analog input signal 100 200 1600 3200 2400 800 Figure 5-43 Step Response [...]

  • Страница 354

    Analog Modules 5-138 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Step Response at an Interference Frequency Suppression of 60 Hz 100 0 Smoo- thing: None: Low: Average: High: Response time in ms Signal variation in percent Step response for any analog input signal 160 80 240 320 400 480 560 640 16.7 267 533 33.3 Figu[...]

  • Страница 355

    Analog Modules 5-139 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Displaying Parameter Assignment Errors The SM 431; AI 8 16 Bit has diagnostics capability . Below you will find an overview of the displays that are possible for modules with parameter assignment errors. T able 5-76 Diagnostic Information of the SM 431[...]

  • Страница 356

    Analog Modules 5-140 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Measuring Ranges Y ou set the measuring ranges by means of the “Measuring Range” parameter in STEP 7 . T able 5-77 Measuring Ranges of the SM 431; AI 8 x 16 Bit Method Selected Measuring Range Description U: V oltage " 25 mV " 50 mV "[...]

  • Страница 357

    Analog Modules 5-141 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.25 Analog Output Module SM 432; AO 8 13 Bit; (6ES7432-1HF00-0AB0) Characteristics The SM 432; AO 8 x 13 Bit has the following features: • 8 outputs • The individual output channels can be programmed as – V oltage outputs – Current outputs •[...]

  • Страница 358

    Analog Modules 5-142 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Assignment Diagram of the SM 432; AO 8 x 13 Bit V oltage output Current output S0– CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7 L+ M L+ QV0 S0+ M QI0 QI1 QI2 QI3 CH0 CH2 CH3 QI4 QI5 QI6 QI7 CH4 CH5 CH6 CH7 L+ M ANA S1– QV1 S1+ S2– QV2 S2+ S3– QV3 [...]

  • Страница 359

    Analog Modules 5-143 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the SM 432; AO 8 x 13 Bit Programming package Associated programming package As of STEP 7 V 2.0 Dimensions and Weight Dimensions W H D (in millimeters) 25 290 210 Weight Approx. 650 g Data for Specific Module Number of outp[...]

  • Страница 360

    Analog Modules 5-144 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Repeat accuracy (in the steady state at 25 ° C, referred to the output range) " 0.05% Output ripple; band width 0 to 50 kHz (with reference to the output range) " 0.05% Status, Interrupts, Diagnostics Interrupts None Diagnostic functions Non[...]

  • Страница 361

    Analog Modules 5-145 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 5.25.1 Commissioning the SM 432; AO 8 13 Bit Parameter Y ou will find a description of the general procedure for assigning parameters to analog modules in Section 5.7. Y ou will find an overview of the programmable parameters and their default values i[...]

  • Страница 362

    Analog Modules 5-146 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07[...]

  • Страница 363

    6-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Interface Modules Chapter Overview Section Description Page 6.1 Common Features of the Interface Modules 6-2 6.2 The Interface Modules IM 460-0; (6ES7460-0AA00-0AB0, 6ES7460-0AA01-0AB0) and IM 461-0; (6ES7461-0AA00-0AA0, 6ES7461-0AA01-0AA0) 6-7 6.3 The Interface Module[...]

  • Страница 364

    Interface Modules 6-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 6.1 Common Features of the Interface Modules Function Interface modules (a send IM and a receive IM) are required if one or more expansion units (EU) are to be connected to a central controller (CC). Th i s configuration is described in the Installati[...]

  • Страница 365

    Interface Modules 6-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Connection possibilities for central racks and expansion racks Central rack CR Expansion rack ER 1 Expansion rack ER 4 Expansion rack ER 1 Expansion rack ER 1 Expansion rack ER 4 Expansion without 5 V local transfer Expansion with 5 V local transfer R[...]

  • Страница 366

    Interface Modules 6-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Rules for Connection When you connect a central rack to expansion racks, you must observe the following rules: • Y ou can connect up to 21 ERs of the S7-400 to one CR. • The ERs are assigned numbers to identify them. The rack number must be set on[...]

  • Страница 367

    Interface Modules 6-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 The following figure shows you a typical configuration with send IMs, receive IMs and terminators. CC Send IM Receive IM Receive IM T erminator Figure 6-1 Example: Configuration with Send IMs, Receive IMs and T erminators Connecting Cable Precut cable[...]

  • Страница 368

    Interface Modules 6-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Installation and Removal of the Modules During Operation Please read the following warning on the insertion and removal of the interface modules and associated connecting cables. ! Caution Data may be lost or corrupted. Removing or inserting the inter[...]

  • Страница 369

    Interface Modules 6-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 6.2 The Interface Modules IM 460-0; (6ES7460-0AA00-0AB0, 6ES7460-0AA01-0AB0) and IM 461-0; (6ES7461-0AA00-0AA0, 6ES7461-0AA01-0AA0) Position of the Operator Controls and Indicators of the IM 460-0 and IM 461-0 LEDs EXTF C1 C2 INTF EXTF DIP switch Exte[...]

  • Страница 370

    Interface Modules 6-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Function The interface module pair IM 460-0 (send IM) and IM 461-0 (r ec e iv e IM ) ar e us ed for a local link. The communication bus is transferred at the full transmission rate . Parameter Assignment for the Mounting Rack Number Using the DIP swit[...]

  • Страница 371

    Interface Modules 6-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Operator Controls and Indicators of the Receive IM INTF LED (red) Lights up if a rack number > 21 or = 0 was set. Lights up if you have changed the rack number under voltage. EXTF LED (red) Lights up in the event of an external fault (line fault, f[...]

  • Страница 372

    Interface Modules 6-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 6.3 The Interface Modules IM 460-1; (6ES7460-1BA00-0AB0, 6ES7460-1BA01-0AB0) and IM 461-1; (6ES7461-1BA00-0AA0, 6ES7461-1BA01-0AA0) Position of the Operator Controls and Indicators of the IM 460-1 and IM 461-1 5 VDC LEDs EXTF C1 C2 INTF EXTF DIP swit[...]

  • Страница 373

    Interface Modules 6-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Function The interface module pair IM 460-1 (send IM) and IM 461-1 (receive IM) are used for a local link (up to a maximum 1.5 m in total). A 5 V supply voltage is also transferred with these interface modules. Please particularly remember the follo[...]

  • Страница 374

    Interface Modules 6-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Operator Controls and Indicators on the Send IM EXTF LED (red) Lights up in the event of an external fault Line 1 or line 2 is faulty (terminator missing or open circuit) C1 LED (green) Line 1 (via front connector X1, connection 1) is correct. C1 LED[...]

  • Страница 375

    Interface Modules 6-13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the IM 460-1 and IM 461-1 Maximum line length (total) 1.5 m Dimensions W x H x D (mm) 25 x 290 x 280 Weight • IM 460-1 • IM 461-1 600 g 610 g Current consumption from the S7-400 bus 5 VDC • IM 460-1 • IM 461-1 T y[...]

  • Страница 376

    Interface Modules 6-14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 6.4 The Interface Modules IM 460-3; (6ES7460-3AA00-0AB0, 6ES7460-3AA01-0AB0) and IM 461-3; (6ES7461-3AA00-0AA0, 6ES7461-3AA01-0AA0) Position of the Operator Controls and Indicators of the IM 460-3 and IM 461-3 LEDs EXTF C1 C2 INTF EXTF DIP switch Ext[...]

  • Страница 377

    Interface Modules 6-15 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Function The interface module pair IM 460-3 (send IM) and IM 461-3 (receive IM) are used for a remote link of up to a maximum 102 m (exactly: 100 m plus inputs/outputs of 0.75 m in the line). The communication bus is transferred at the full transmiss[...]

  • Страница 378

    Interface Modules 6-16 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Operator Controls and Indicators on the Send IM EXTF LED (red) Lights up in the event of an external fault Line 1 or line 2 is faulty (terminator missing or broken cable) C1 LED (green) Line 1 (via front connector X1, connection 1) is correct. C1 LED[...]

  • Страница 379

    Interface Modules 6-17 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the IM 460-3 and IM 461-3 Maximum line length (total) 102 m Dimensions W x H x D (mm) 25 x 290 x 280 Weight • IM 460-3 • IM 461-3 630 g 620 g Current consumption from the S7-400 bus 5 VDC • IM 460-3 • IM 461-3 T y[...]

  • Страница 380

    Interface Modules 6-18 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 6.5 The Interface Modules IM 460-4; (6ES7460-4AA01-0AB0) and IM 461-4; (6ES7461-4AA01-0AA0) Position of the Operator Controls and Indicators of the IM 460-4 and IM 461-4 LEDs EXTF C1 C2 INTF EXTF DIP switch Connector X1: Interface C2 Interface C1 Con[...]

  • Страница 381

    Interface Modules 6-19 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Function The interface module pair IM 460-4 (send IM) and IM 461-4 (receive IM) are used for a remote link of up to a maximum 605 m (exactly: 600 m plus inputs/outputs of 1.5 m in the line). Parameterization Using the DIP switch on the front panel of[...]

  • Страница 382

    Interface Modules 6-20 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Operator Controls and Indicators on the Send IM EXTF LED (red) Lights up in the event of an external fault Line 1 or line 2 is faulty (terminator missing or broken cable) C1 LED (green) Line 1 (via front connector X1, connection 1) is correct. C1 LED[...]

  • Страница 383

    Interface Modules 6-21 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T echnical Specifications of the IM 460-4 and IM 461-4 Maximum line length (total) 605 m Dimensions W x H x D (mm) 25 x 290 x 280 Weight • IM 460-4 • IM 461-4 630 g 620 g Current consumption from the S7-400 bus 5 VDC • IM 460-4 • IM 461-4 T y[...]

  • Страница 384

    Interface Modules 6-22 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07[...]

  • Страница 385

    7-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 IM 463-2 Chapter Overview Section Description Page 7.1 Using SIMA TIC S5 Expansion Units in an S7-400 7-2 7.2 Rules for Connecting S5 Expansion Units 7-3 7.3 Operator Controls and Indicators 7-4 7.4 Installing and Connecting the IM 463-2 7-6 7.5 Setting the Operating M[...]

  • Страница 386

    IM 463-2 7-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 7.1 Using SIMA TIC S5 Expansion Units in an S7-400 Area of Application The IM 463-2 interface module is used for distributed connection of S5 expansion units to an S7-400. Y ou can use the IM 463-2 in the CR of the S7-400. In the S5 expansion unit, you use an [...]

  • Страница 387

    IM 463-2 7-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 7.2 Rules for Connecting S5 Expansion Units Introduction When you connect S5 expansion units to an S7-400 via the IM 463-2, there are rules to observe with regard to cable length, maximum expansion, use of a terminating connector and permissible potential diff[...]

  • Страница 388

    IM 463-2 7-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 7.3 Operator Controls and Indicators Introduction All controls and indicators on the IM 463-2 are arranged on the front plate. The following figure shows the arrangement of the controls and indicators. LEDs EXTF , C1, C 2 Interface selector switch Cable length[...]

  • Страница 389

    IM 463-2 7-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 LEDs T able 7-2 LEDs of the IM 4632 LED Meaning LED EXTF (red) Lights up in the event of an external fault. Chain 1 or chain 2 has a fault (power supply failed in the EU; terminating connector missing; wire break, or interface selector switch wrongly set). LED[...]

  • Страница 390

    IM 463-2 7-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 7.4 Installing and Connecting the IM 463-2 Introduction T o install an IM 463-2 in a CR of the S7-400, proceed in the same way as when installing other S7-400 modules (see Installation Manual , Chapter 5). T o connect an IM 463-2, follow the steps outlined bel[...]

  • Страница 391

    IM 463-2 7-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Plugging in the Connecting Cable T o plug in the connecting cable, follow the steps outlined below: 1. Open the cover of the IM 463-2. 2. Plug the new connector of the connecting cable into one of the connectors of the IM 463-2. Interface C1 corresponds to the[...]

  • Страница 392

    IM 463-2 7-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 7.5 Setting the Operating Modes of the IM 314 Introduction T o operate the IM 463-2, you must set on the IM 314 the S5 expansion unit used and the address area of the S5 I/O modules. Setting the S5 Expansion Unit Y ou set the S5 expansion unit in which you wan[...]

  • Страница 393

    IM 463-2 7-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Setting the Address Area The address area of the S5 I/O modules is set on the IM 314. This setting applies only for the digital and analog I/O modules. The address areas P , Q, IM3, and IM4 are available. Set the switch to the relevant position to address the [...]

  • Страница 394

    IM 463-2 7-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 7.6 Configuring S5 Modules for Operation in the S7-400 Y ou configure the S5 modules using STEP 7. See the description of STEP 7 or the online help function for details of how to proceed. The following figure shows a possible connection of CRs and EUs via the[...]

  • Страница 395

    IM 463-2 7-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 7.7 Pin Assignments of the 721 Connecting Cable T able 7-6 Assignment of the Connecting Cable 721 34 50 17 1 34 50 17 1 Connector 50-Pin Contact Bundle Ident. Sheath Identification Foil Core Color Connector 50-Pin Contact 20 white 20 21 brown 21 4 green 4 5 [...]

  • Страница 396

    IM 463-2 7-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 7-6 Assignment of the Connecting Cable 721, continued Connector 50-Pin Contact Connector 50-Pin Contact Core Color Identification Foil Bundle Ident. Sheath 28 white 28 29 brown 29 12 green 12 13 4 brown yellow 13 46 4 No. 19 brown gray 46 47 pink 47 30[...]

  • Страница 397

    IM 463-2 7-13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 7.8 T erminating Connector for IM 314 Introduction The IM 314 of the last expansion unit of each chain is terminated with the 6ES5 760-1AA1 1 terminating connector . T able 7-7 Assignment of the T erminator 760-1AA1 1 34 50 1 7 1 Plug Connection 180-Ohm Resis[...]

  • Страница 398

    IM 463-2 7-14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 7.9 T echnical Specifications (6ES7463–2AA00–0AA0) Programming package Associated programming package As of STEP7 V 2.1 Dimensions and Weight Dimensions WxHxD (mm) 25x290x280 Weight 360 g Module-Specific Data Number and type of interfaces 2 parallel, symm[...]

  • Страница 399

    8-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 PROFIBUS DP Master Interface IM 467/IM 467 FO Chapter Overview Section Description Page 8.1 PROFIBUS DP Master Interface IM 467/IM 467 FO 8-2 8.2 Configuration 8-6 8.3 Connection to PROFIBUS DP 8-8 8.4 T echnical Specifications 8-12 8[...]

  • Страница 400

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 8.1 PROFIBUS DP Master Interface IM 467/IM 467 FO Order Numbers IM 467 6ES7467-5GJ02-0AB0 (RS 485) IM 467 FO 6ES7467-5FJ00-0AB0 (F0) Application PROFIBUS DP , standardized to IEC 61784–1:2002 Ed1 CP 3/1, enables rapid com[...]

  • Страница 401

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 PROFIBUS DP interface 9-pin subminiature D LEDs Mode selector Figure 8-1 Configuration of the IM 467/467 FO Communication Services The IM 467/IM 467 FO offers two communication services: • PROFIBUS DP The IM 467/IM 467 FO[...]

  • Страница 402

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 8.1.1 Indicators and the Mode Selector LED The LED plate on the front panel of the IM 467/ IM 467 FO has the following four indicators: INTF EXTF RUN STOP Figure 8-2 LEDs of the IM 467/467 FO IM Operating Mode The LEDs indi[...]

  • Страница 403

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Controlling the Operating Mode There are two ways to control the operating mode of the IM 467/IM 467 FO: • By using the mode selector • By using the programming device/PC Mode Selector Y ou can switch operating modes as[...]

  • Страница 404

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 8.2 Configuration The IM 467/IM 467 FO is configured with STEP 7. The configuration data are retained even in the event of a power failure; a memory module is not required. Using the S7 functions it is possible to program a[...]

  • Страница 405

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Prerequisites The IM 467/IM 467 FO is supported by all the CPU operating systems beginning with the release numbers listed below . Y ou will also find the following information in the table: • The number of IM 467/IM 467 [...]

  • Страница 406

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 8.3 Connection to PROFIBUS DP There are two ways of connecting to PROFIBUS DP: • Electrical connection via a bus connector • Optical connection using a fiber-optic cable 8.3.1 Bus Connector Only with 6ES7467-5GJ02-0AB0.[...]

  • Страница 407

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Connector Pin Assignment The electrical interface used to connect to PROFIBUS DP (9-pin subminiature D female connector) is specified in the following table. 1 2 3 4 5 6 7 8 9 PE – RxD/ TxD– P RTS ( AG) M5V 2 P5V 2 BA T[...]

  • Страница 408

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 8.3.3 Connecting a Fiber-Optic Cable to the IM 467 FO Accessories Required • Pack of Simplex connectors and polishing sets (6GK1901-0FB00-0AA0) • Pack of plug-in adapters (6ES7195-1BE00-0XA0) Installing Connectors 1. R[...]

  • Страница 409

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Reusing Fiber-Optic Cables Note If you insert used fiber-optic cables in the plug-in adapter again, you must cut off the bent lengths of both fiber-optic cable cores and install the Simplex connectors again. This avoids a[...]

  • Страница 410

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 8.4 T echnical Specifications 8.4.1 T echnical Specifications of the IM 467 6ES7467-5GJ02-0AB0. Dimensions and W eight Dimensions W x H x D (mm) Weight 25 x 290 x 210 700 g PROFIBUS DP • Standard • T ransmission rate ?[...]

  • Страница 411

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 8.4.2 T echnical Specifications of the IM 467 FO 6ES7 467-5FJ00-0AB0 Dimensions and W eight Dimensions W x H x D (mm) Weight 25 x 290 x 210 700 g PROFIBUS DP • Standard • T ransmission rate • T ransmission technology[...]

  • Страница 412

    PROFIBUS DP Master Interface IM 467/IM 467 FO 8-14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07[...]

  • Страница 413

    9-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Cable Duct and Fan Subassemblies Chapter Overview Section Description Page 9.1 Fan Monitoring in the Fan Subassemblies 9-2 9.2 Cable Duct; (6ES7408-0T A00-0AA0) 9-4 9.3 The 120/230 V AC Fan Subassembly; (6ES7408-1TB00-0XA0) 9-5 9.4 The 24 VDC Fan Subassembly; (6ES7408-[...]

  • Страница 414

    Cable Duct and Fan Subassemblies 9-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 9.1 Fan Monitoring in the Fan Subassemblies In this section, you will find out how to monitor the fans. There is a signaling concept example at the end of the section. LEDs The three red LEDs are assigned to the individual fans. From le[...]

  • Страница 415

    Cable Duct and Fan Subassemblies 9-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Signaling Concept Example Y ou can check the fault-free functioning of the fan subassembly using digital inputs. Y ou can cause the power supply to be cut off after the failure of at least two fans by using the relay K2. For example, yo[...]

  • Страница 416

    Cable Duct and Fan Subassemblies 9-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 9.2 Cable Duct; (6ES7408-0T A00-0AA0) Function The cable duct is used in installations outside the cabinet for • Cable clamping and/or for • Shielding or for • Air circulation without fan assistance Front View of the Cable Duct Sh[...]

  • Страница 417

    Cable Duct and Fan Subassemblies 9-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 9.3 The 120/230 V AC Fan Subassembly; (6ES7408-1TB00-0XA0) Operator Controls and Indicators on the 120/230 V AC Fan Subassembly LEDs F1, F2, F3 Quick-release lock Relay contacts 1, 2, 3 Relay contacts 4, 5, 6 V oltage selector switch Fu[...]

  • Страница 418

    Cable Duct and Fan Subassemblies 9-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Shielding Clamps If you do not require the shielding clamps supplied, do not install them in the fan subassembly . T echnical Specifications Dimensions, W eights Dimensions WxHxD (mm) 482.5 × 109.5 × 235 () Weight appr. 2000 g Cable d[...]

  • Страница 419

    Cable Duct and Fan Subassemblies 9-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 9.4 The 24 VDC Fan Subassembly; (6ES7408-1T A00-0XA0) Operator Controls and Indicators on the 24 VDC Fan Subassembly LEDs F1, F2, F3 Quick-release lock Relay contacts 1, 2, 3 Relay contacts 4, 5, 6 Fuse compartment 1 A T 1 AT Figure 9-4[...]

  • Страница 420

    Cable Duct and Fan Subassemblies 9-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Signaling Concept The signaling concept of the 24 VDC fan subassembly is identical to the signaling concept of the 120/230 V AC fan subassembly . Fuse Included in this fan subassembly are standard cartridge fuse links, 5 x 20 mm, confor[...]

  • Страница 421

    10-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 RS 485 Repeater In this Chapter In this chapter , you will find a detailed description of the RS 485 repeater . Included in the description are: • The purpose of the RS 485 repeater • The maximum cable lengths possible between two RS 485 repeaters • The function[...]

  • Страница 422

    RS 485 Repeater 10-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 10.1 Application and Characteristics (6ES7972-0AA01-0XA0) What is an RS 485 Repeater? The RS 485 repeater amplifies data signals on bus lines and interconnects bus segments. Application of the RS 485 Repeater Y ou need an RS 485 repeater if: • more t[...]

  • Страница 423

    RS 485 Repeater 10-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 10.2 Appearance of the RS 485 Repeater; (6ES7972-0AA01-0XA0) The table below shows the appearance of the RS 485 repeater and lists its functions. T able 10-3 Description and Functions of the RS 485 Repeater Repeater Design No . Function 24 VDC L+ M PE [...]

  • Страница 424

    RS 485 Repeater 10-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 10.3 RS 485 Repeater in Ungrounded and Grounded Operation Grounded or Ungrounded The RS 485 repeater is ... • grounded, if all other nodes in the segment are also operated with a grounded potential • ungrounded, if all other nodes in the segment ar[...]

  • Страница 425

    RS 485 Repeater 10-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T erminal Connection Diagram In the case of a repeater configuration with ungrounded reference potential (ungrounded operation), any interference currents and static charges are discharged by means of an RC network integrated in the repeater (refer to [...]

  • Страница 426

    RS 485 Repeater 10-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Amplification of the Bus Signals The amplification of the bus signals takes place between the port for bus segment 1 or the PG/OP interface and the port for bus segment 2. 10.4 T echnical Specifications T echnical Specifications of the RS 485 Repeater [...]

  • Страница 427

    RS 485 Repeater 10-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Block Diagram of the RS 485 Repeater • Bus segment 1 and bus segment 2 are galvanically isolated from each other . • Bus segment 2 and the PG/OP socket are galvanically isolated from each other . • Signals are amplified – between bus segment 1 [...]

  • Страница 428

    RS 485 Repeater 10-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07[...]

  • Страница 429

    1 1-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 CPUs for M7-400 In this Chapter This chapter describes the CPUs of the M7-400 automation computer: • CPU 486-3, • CPU 488-3, The CPUs differ essentially in their clock frequencies. Y ou will find a comparison of their performance features in T able 1 1-1. The tab[...]

  • Страница 430

    CPUs for M7-400 1 1-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.1 Performance Features Introduction There are two CPUs with different clock frequencies available for use with the automation computer . T able 1 1-1 gives you an overview of the most important performance features of these CPUs. T able 1 1-1 Perf[...]

  • Страница 431

    CPUs for M7-400 1 1-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.2 T echnical Specifications The following table contains the technical specifications of the CPUs for the M7-400 automation computer . T able 1 1-2 T echnical Specifications of the CPUs CPU 486-3 (6ES7486-3AA00-0AB0) CPU 488-3 (6ES7488-3AA00-0AB0)[...]

  • Страница 432

    CPUs for M7-400 1 1-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.3 Function Elements Introduction In this section you will become familiar with the individual function elements of the CPU 486-3 and CPU 488-3. Y ou require the information here to be able to respond to displays, start up, and operate an M7-400 au[...]

  • Страница 433

    CPUs for M7-400 1 1-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 CPU Elements The following table gives the meanings of the individual elements of the CPU 486-3 and CPU 488-3. T able 1 1-3 Elements of the CPU 486-3 and CPU 488-3 Element Meaning Status and fault LEDs The status and fault LEDs indicate the operating [...]

  • Страница 434

    CPUs for M7-400 1 1-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.3.1 Status and Fault LEDs Status and Fault LEDs The CPU 486-3 and CPU 488-3 have the following status and fault LEDs: INTF EXTF SD HD USR1 USR2 RUN STOP Figure 1 1-2 Status and Fault LEDs on the CPU 486-3 and CPU 488-3[...]

  • Страница 435

    CPUs for M7-400 1 1-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Meaning of the Status and Fault LEDs The status and fault LEDs are explained in T able 1 1-4 in the order in which they are arranged on the CPU 486-3 and CPU 488-3 modules. The following status and fault LEDs are available: T able 1 1-4 Meaning of the[...]

  • Страница 436

    CPUs for M7-400 1 1-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.3.2 Memory Cards Introduction The CPU 486-3 and CPU 488-3 offer the possibility of operating a memory card in the same way as a diskette. In this section, you will learn how you can use these options. Note If the power fails during a write access [...]

  • Страница 437

    CPUs for M7-400 1 1-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.3.3 Mode Selector Switch Mode Selector Switch The mode selector switch of the CPUs is a keyswitch. Y ou can see the positions of the mode selector switch in the following figure. MRES STOP RUN RUN-P Figure 1 1-3 Mode Selector Switch Positions of t[...]

  • Страница 438

    CPUs for M7-400 1 1-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 1 1-5 Positions of the Mode Selector Switch Position of the Mode Selector Switch Explanations STOP I/O access is disabled for the user program of the CPU. The user program cannot control the process. The key can be removed in this position to [...]

  • Страница 439

    CPUs for M7-400 1 1-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.3.4 Submodule Receptacles for Interface Submodules Submodule Receptacle Definition The submodule receptacle is a slot for a submodule. The CPU 486-3 and CPU 488-3 have a receptacle for the memory card and two submodule receptacles for interface [...]

  • Страница 440

    CPUs for M7-400 1 1-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Numbering on the Submodule Receptacles Each receptacle for an interface submodule has a submodule receptacle number assigned to it. The submodule receptacle number depends on the module slot and on the arrangement of the receptacle on the expansion m[...]

  • Страница 441

    CPUs for M7-400 1 1-13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.3.5 Memory Submodules Suitable for the Main Memory Introduction Y ou must order the MEM 478 DRAM memory submodules for the main memory of the CPUs separately . They are also shipped separately . These memory submodules must be inserted before plu[...]

  • Страница 442

    CPUs for M7-400 1 1-14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.3.6 Expansion Socket Introduction The CPU 486-3 and CPU 488-3 are each equipped with an expansion socket. The ISA bus is continued via the expansion socket. Which Expansions Can Be Connected? One EXM 478 extension module with up to three interfac[...]

  • Страница 443

    CPUs for M7-400 1 1-15 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.3.7 Multipoint Interface (MPI) X1 Interface The X1 interface of the CPU 486-3 and CPU 488-3 for connecting devices such as PCs/programming devices is a multipoint interface (MPI) and is connected via a 9-pin sub D connector . Suitable Devices Y o[...]

  • Страница 444

    CPUs for M7-400 1 1-16 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.4 The BIOS Setup Overview The BIOS setup handles the configuration of the relevant CPUs in your M7-400 system. The settings and technical information concerning the configuration of this programmable module are displayed in the BIOS setup. The CP[...]

  • Страница 445

    CPUs for M7-400 1 1-17 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.4.1 BIOS Power Up Power Up without Error Message After switching on or after warm restart of the CPU, the BIOS (B asic I nput O utput S ystem) starts a ”P ower O n S elf T est” (POST) and displays the results in the POST window . Figure 1 1-6[...]

  • Страница 446

    CPUs for M7-400 1 1-18 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Power Up with Error Message If one of the following errors occurs: • Memory test error • Hard disk configuration error • CMOS checksum error , the INTF LED remains lit as well as the STOP LED. A window appears on the screen with the relevant er[...]

  • Страница 447

    CPUs for M7-400 1 1-19 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.4.2 BIOS Hot Keys BIOS Hot Keys After power up, the BIOS offers the user a range of functions under MS-DOS. These functions are executed by pressing the following groups of keys simultaneously: T able 1 1-7 BIOS Hot Keys with German and English K[...]

  • Страница 448

    CPUs for M7-400 1 1-20 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.4.3 Operator Inputs in the BIOS Setup Definition of the Setup Fields Within the BIOS setup, there are fields in which you can make entries or selections. These fields have the following functions: • Editbox; Y ou can enter desired values in thi[...]

  • Страница 449

    CPUs for M7-400 1 1-21 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Key Control within the Setup Menu The following keys are used for control within the Setup menu and the associated setup page (conforming to the Windows TM Standard): ENTER With this key , you jump to the first line of a list box, edit box, check box[...]

  • Страница 450

    CPUs for M7-400 1 1-22 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 ↑ ↓ With the cursor control keys, you can jump from line to line within a list box. The line you are in is marked with a dark bar . Y ou can page with the cursor control keys within an edit box if there are several values available for selection [...]

  • Страница 451

    CPUs for M7-400 1 1-23 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.4.4 Opening and Exiting the BIOS Setup Opening the Setup Menu T o open the Setup menu, press the following keys simultaneously while the CPU is powering up and the POST window (Figure 1 1-6) is on the screen: CTRL + Alt + ESC or ESC under Remote [...]

  • Страница 452

    CPUs for M7-400 1 1-24 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Exiting the BIOS Setup T o exit the BIOS setup, activate the EXIT button shown in Figure 1 1-9 or press ESC . The “Setup Exit” dialog box then appears (see Figure 1 1-10). Figure 1 1-10 “Setup Exit” Dialog Box Here you have the following choi[...]

  • Страница 453

    CPUs for M7-400 1 1-25 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 What is the Purpose of the Setup Page? This setup page contains notes that help you to use the Setup menu. OK Button Activating this button returns to the Setup menu. 1 1.4.6 Setup Page “IF modules” Opening the Setup Page If you have selected “[...]

  • Страница 454

    CPUs for M7-400 1 1-26 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Accepting Edited V alues Only the values for which the relevant interface submodule has been designed are accepted by the system in the edit boxes. If, for example, you enter three values under “Interrupt Source” and the interface submodule only [...]

  • Страница 455

    CPUs for M7-400 1 1-27 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Interrupt Source Here, you set interrupts A to C (see the “Interface Submodules” chapter) provided for the interface submodule. The values positioned on the left are setpoints. Y ou can edit these. The value indicated in gray type to the right of[...]

  • Страница 456

    CPUs for M7-400 1 1-28 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 V alue (Gray T ype) Under the address set with “Config. Index”, you can now enter the configuration value. Y ou will find this value and its significance in the chapter “Interface Submodules” under the relevant interface submodule. The config[...]

  • Страница 457

    CPUs for M7-400 1 1-29 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.4.7 Setup Page “Timeout Function” Opening the Setup Page If you have selected “T imeout Function” in the Setup menu (Figure 1 1-9 on page 1 1-23) and activated the OPEN button, this setup page appears on the screen (Figure 1 1-13). Figure[...]

  • Страница 458

    CPUs for M7-400 1 1-30 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 CANCEL Button Activating this button returns to the Setup menu. Deletes all changes you have made on the setup page. 1 1.4.8 Setup Page “Security” Opening the Setup Page If you have selected “Security” in the Setup menu (Figure 1 1-9 on page [...]

  • Страница 459

    CPUs for M7-400 1 1-31 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Password Enter Setup By activating this check box, you can assign a password that authorizes access to the Setup. System Boot By activating this check box, you can assign a password that permits booting of the operating system. Y ou can only set this[...]

  • Страница 460

    CPUs for M7-400 1 1-32 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.4.9 Setup Page “Date and Time” Opening the Setup Page If you have selected “Date and T ime” and activated the OPEN button in the Setup menu (Figure 1 1-9 on page 1 1-23), this BIOS setup page appears on the screen (Figure 1 1-15). Figure [...]

  • Страница 461

    CPUs for M7-400 1 1-33 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.4.10 “Hard Disk” Setup Page Opening the Setup Page If you have selected “Hard Disk” and activated the OPEN button in the Setup menu (Figure 1 1-9 on page 1 1-23), this BIOS setup page appears on the screen (Figure 1 1-16). Figure 1 1-16 ?[...]

  • Страница 462

    CPUs for M7-400 1 1-34 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T ranslation Mode In T ranslation Mode you have four possible settings: • Auto reads the hard disk parameters and automatically sets the correct mode (Normal, LBA, Large). The T ranslation Mode “Auto” is set as the default. • Normal used for [...]

  • Страница 463

    CPUs for M7-400 1 1-35 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.4.1 1 Setup Page “Floppy/Card” Opening the Setup Page If you have selected “Floppy/Card” and activated the OPEN button in the Setup menu (Figure 1 1-9 on page 1 1-23), this setup page appears on the screen (Figure 1 1-17). Figure 1 1-17 ?[...]

  • Страница 464

    CPUs for M7-400 1 1-36 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.4.12 Setup Page “Boot Options” Opening the Setup Page If you have selected “Boot Options” and activated the OPEN button in the Setup menu (Figure 1 1-9 on page 1 1-23), this setup page appears on the screen (Figure 1 1-18). Figure 1 1-18 [...]

  • Страница 465

    CPUs for M7-400 1 1-37 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Halt On ... Here you can choose which error messages are displayed in an error window during booting. Displaying an error window delays booting by approximately 2 seconds. Keyboard State T ypematic Settings Enabled If you activate this check box, the[...]

  • Страница 466

    CPUs for M7-400 1 1-38 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.4.13 Setup Page “System” Opening the Setup Page If you have selected “System” and activated the OPEN button in the Setup menu (Figure 1 1-9 on page 1 1-23), this setup page appears on the screen (Figure 1 1-19). Figure 1 1-19 “System”[...]

  • Страница 467

    CPUs for M7-400 1 1-39 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 System Cache For the memory areas of the System ROM, the VIDEO ROM, and the addresses of BIOS expansions, you can set whether they are copied to the Shadow RAM and whether the cache should be used. • System ROM offers you the following possible sel[...]

  • Страница 468

    CPUs for M7-400 1 1-40 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 1 1.5 I/O Addresses, Main Memory and Interrupt Assignments Introduction This section gives you detailed information, in the form of a table, on the I/O address space assignment, main memory and interrupt assignments of the CPUs. Memory Assignment The[...]

  • Страница 469

    CPUs for M7-400 1 1-41 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Memory Areas for A T Cards A T cards which are inserted in the expansion module A TM 478 can occupy the following memory areas: Range M7 RMOS32 M7 RMOS32 with MS-DOS M7 RMOS32 with Without EMS With EMS w i t h MS-Windows D 0000H to E 7FFFH 96 K 96 K [...]

  • Страница 470

    CPUs for M7-400 1 1-42 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Interrupt Assignment T able 1 1-9 Interrupt Assignment Interrupt Function NMI Group interrupt for faults and reset signals IRQ0 System timer IRQ1 Reserved for keyboard IRQ2 Cascading of the 2nd interrupt controller IRQ3 Assigned to COM2, otherwise fr[...]

  • Страница 471

    12-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 M7-400 Expansions Chapter Overview Section Description Page 12.1 Overview 12-2 12.2 EXM 478 Expansion Module; (6ES7 478-2AC00-0AC0) 12-6 12.3 A TM 478 A T Adapter Module; (6ES7 478-2CA00-0AC0) 12-15 12.4 MSM 478 Mass Storage Module; (6ES7 478-2BA00-0AC0) 12-22 12[...]

  • Страница 472

    M7-400 Expansions 12-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 12.1 Overview Introduction Y ou can expand your automation computer from the M7-400 range by adding expansion modules for interface submodules, short A T modules, and/or the mass storage module. The interface submodules can include the IF 962-COM, IF[...]

  • Страница 473

    M7-400 Expansions 12-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Behavior on the S7-400 Backplane Bus The expansion modules can be accessed via the relevant programmable module and not via the S7-400 backplane bus. e.g. FM 456-4 e.g. EXM 478 Expansion socket Expansion connector Figure 12-1 Positions of Expansion S[...]

  • Страница 474

    M7-400 Expansions 12-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 e.g. FM 456-4 e.g. EXM 478 e.g. A TM 478 e.g. MSM 478 Figure 12-2 Maximum Expansion with Expansion Modules[...]

  • Страница 475

    M7-400 Expansions 12-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Permissible Combinations Y ou can see from the table below which expansions can be connected to the programmable M7-400 modules. T able 12-1 Expansion Possibilities of the CPU 486-3, CPU 488-3, or FM 456 Programmable M7-400 Module Slot Slot Slot Slot[...]

  • Страница 476

    M7-400 Expansions 12-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 12.2 EXM 478 Expansion Module; (6ES7 478-2AC00-0AC0) Characteristics The EXM 478 expansion module is used to house up to three interface submodules. By installing the relevant interface submodule in this expansion module, such as the IF 962-VGA and I[...]

  • Страница 477

    M7-400 Expansions 12-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 12.2.1 Addressing the EXM 478 Expansion Module Introduction In order to be able to program the interface submodules in the EXM 478 expansion module, you must be able to determine their addresses. There are the following addressing methods: • Addres[...]

  • Страница 478

    M7-400 Expansions 12-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Numbering of the Submodule Receptacles Each receptacle (slot) for an interface submodule has a submodule receptacle number assigned to it. The submodule receptacle number depends on the configuration of your CPU or FM. The submodule slot numbers are [...]

  • Страница 479

    M7-400 Expansions 12-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 3 08 6 7 91 2 10 13 11 1 4 CPU 486-3/ CPU 488-3 EXM 478 Slot n n+2 n+3 n+4 n+1 Figure 12-5 Submodule Receptacle Numbers for the CPU 486-3, CPU 488-3, and EXM 478[...]

  • Страница 480

    M7-400 Expansions 12-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Division of Addresses in the M7-400-Specific I/O Address Area The EXM 478 expansion module is operated on the ISA bus of the programmable module. The I/O address area from C000 H (to D2FF H ) in the CPU 486-3, CPU 488-3, or the FM 456 application mo[...]

  • Страница 481

    M7-400 Expansions 12-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Addresses Within an Expansion Module Each expansion module occupies 256 bytes (100 H ) within the CPU/FM address area. The division of the 256 addresses within an expansion module can be seen from T able 12-2. T able 12-2 Division of Addresses With[...]

  • Страница 482

    M7-400 Expansions 12-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 12-3 Base Addresses of the Interface Submodules with FM 456-4 Base Address Modules Interface Submodule in Submodule Receptacle ... Cn40 H FM 456-4 Number 0 Cn80 H FM 456 4 Slot n Number 1 Co40 H Nummer 3 Co80 H 1st EXM 478 in slot o = n + 1 N[...]

  • Страница 483

    M7-400 Expansions 12-13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 12.2.2 Interrupt Assignments, Signal Switching EXM 478 Introduction Up to three interrupts per interface submodule are permitted in an EXM 478 expansion module. The various possible methods of interrupt assignment or interrupt operation are describe[...]

  • Страница 484

    M7-400 Expansions 12-14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 12.2.3 T echnical Specifications of the EXM 478 Expansion Module T echnical Specifications of the EXM 478 The table below contains the technical specifications of the EXM 478 expansion module: EXM 478 6ES7 478-2AC00-0AC0 Performance Features Number [...]

  • Страница 485

    M7-400 Expansions 12-15 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 12.3 A TM 478 A T Adapter Module; (6ES7 478-2CA00-0AC0) Characteristics The A TM 478 A T adapter module is used to accommodate a short A T module (card). The A TM 478 A T adapter module has a 120-pin connector on the left-hand side and a 120-pin soc[...]

  • Страница 486

    M7-400 Expansions 12-16 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 12.3.1 Pin Assignments of the A T Module Pin Assignments The A TM 478 A T adapter module has a 98-pin standard direct connector for short A T modules (see Figure 12-8). 16 bit data 8 bit data Figure 12-8 A TM 478 A T Adapter Module, 98-Pin Standard [...]

  • Страница 487

    M7-400 Expansions 12-17 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 12-5 Pin Assignments of the 98-Pin Standard Direct Connector (A TConnector) Pin Signal Name Pin Signal Name XT Signals B1 GND A1 I/OCHCK_N B2 RESET DRV A2 SD7 B3 P5V A3 SD6 B4 IRQ9 A4 SD5 B5 N5V A5 SD4 B6 DRQ2 A6 SD3 B7 N12V A7 SD2 B8 0WS A8 [...]

  • Страница 488

    M7-400 Expansions 12-18 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 12-5 Pin Assignments of the 98-Pin Standard Direct Connector (A TConnector), continued Pin Signal Name Pin Signal Name A T Expansion D1 MEMCS_16_N C1 SBHE_N D2 I/OCS16_N C2 LA23 D3 IRQ10 C3 LA22 D4 IRQ1 1 C4 LA21 D5 IRQ12 C5 LA20 D6 IRQ15 C6 [...]

  • Страница 489

    M7-400 Expansions 12-19 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 12.3.2 T echnical Specifications of the A TM 478 A T Adapter Module T echnical Specifications of the A TM 478 The table below contains the technical specifications of the A TM 478 A T adapter module: ATM 478 6ES7 478-2CA00-0AC0 Performance Features [...]

  • Страница 490

    M7-400 Expansions 12-20 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Example of Power Loss Calculation The following table contains a calculation example for the total power losses for an A T adapter module with an A T module. T able 12-6 Calculation Example for T otal Power Losses of an A TM 478 with A T Module Rema[...]

  • Страница 491

    M7-400 Expansions 12-21 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Permissible Dimensions of A T Modules The following illustration shows you the maximum and minimum dimensions in millimeters that A T modules must meet for the A TM 478 A T adapter module. If these dimensions are not conformed to, proper installatio[...]

  • Страница 492

    M7-400 Expansions 12-22 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 12.4 MSM 478 Mass Storage Module; (6ES7 478-2BA00-0AC0) Characteristics The MSM 478 mass storage module is used for storing programs and larger quantities of data. It also has an A T -compatible parallel port (LPT). The MSM 478 mass storage module h[...]

  • Страница 493

    M7-400 Expansions 12-23 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 12.4.1 LPT1 Parallel Port Characteristics The MSM 478 mass storage module has an A T -compatible parallel port (LPT) for connecting a printer with Centronics interface. The parallel port can also be used as a bi-directional data interface. There is [...]

  • Страница 494

    M7-400 Expansions 12-24 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 12-7 MSM 478 Parallel Port, Socket X1 (25-Pin Sub D Socket) Pin Meaning Direction 1 /STROBE Input/output 2 Data 0 Input/output 3 Data 1 Input/output 4 Data 2 Input/output 5 Data 3 Input/output 6 Data 4 Input/output 7 Data 5 Input/output 8 Dat[...]

  • Страница 495

    M7-400 Expansions 12-25 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 12.4.2 T echnical Specifications of the MSM 478 Mass Storage Module T echnical Specifications of the MSM 478 The table below contains the technical specifications of the MSM mass storage module: 478 With Mass Storage Module MSM 478 6ES7 478-2AB00-0A[...]

  • Страница 496

    M7-400 Expansions 12-26 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07[...]

  • Страница 497

    13-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Interface Submodules Chapter Overview Section Description Page 13.1 Interface Submodules Overview 13-2 13.2 Submodule IDs and Insertion Rules 13-4 13.3 IF 962-VGA Interface Submodule for M7-300/400; (6ES7962-1BA00-0AC0) 13-5 13.4 IF 962-COM Interface Submodule for M7-[...]

  • Страница 498

    Interface Submodules 13-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.1 Interface Submodules Overview Introduction The interface submodules are designed for use in the M7-300 and M7-400 automation computers. They can be operated in the M7-400 programmable modules and in the EXM 378/EXM 478 expansion modules. The [...]

  • Страница 499

    Interface Submodules 13-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Interrupt Assignments When configuring the interface submodules in the BIOS setup, you can assign ISA interrupts to the three interrupts of an interface submodule (IRQa, IRQb, IRQc). For this purpose, enter the ISA interrupt provided in the releva[...]

  • Страница 500

    Interface Submodules 13-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.2 Submodule IDs and Insertion Rules Submodule IDs The following table contains an overview of the submodule IDs for the interface submodules. T able 13-2 Overview of the Submodule IDs for the Interface Submodules Interface Submodule Submodule I[...]

  • Страница 501

    Interface Submodules 13-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.3 IF 962-VGA Interface Submodule for M7-300/400; (6ES7962-1BA00-0AC0) Characteristics The IF 962-VGA interface submodule is used to connect a keyboard and a VGA screen. The interfaces to the keyboard and the screen are A T -compatible. As an al[...]

  • Страница 502

    Interface Submodules 13-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.3.1 Pin Assignments Socket X1 VGA Screen Connection T able 13-4 Socket X1, VGA Screen Connection IF 962-VGA (15-Pin High-Density Sub D Socket Connector) Pin Meaning 1 Analog red 2 Analog green 3 Analog blue 4 5 Signal GND 6 Analog GND red 7 Ana[...]

  • Страница 503

    Interface Submodules 13-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.3.2 Addressing, Interrupts, and Submodule ID Addressing Addressing corresponds to the A T standard. The following addresses are occupied by the IF 962-VGA interface submodule: Memory addresses: A0000 H to C7FFF H I/O addresses: 060 H to 06F H ,[...]

  • Страница 504

    Interface Submodules 13-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.3.3 T echnical Specifications T echnical Specifications The IF 962-LPT interface submodule receives its supply voltage from the M7-400 programmable modules or from the M7-300/400 expansion modules. The current consumption given in the technical[...]

  • Страница 505

    Interface Submodules 13-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Operating Modes The WD90C24 VGA controller is used on the IF 962-VGA interface submodule. T able 13-7 shows you the video modes supported by the BIOS of the IF 962-VGA interface submodule. T able 13-7 Video Modes of the IF 962-VGA Interface Submod[...]

  • Страница 506

    Interface Submodules 13-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.4 IF 962-COM Interface Submodule for M7-300/400; (6ES7962-3AA00-0AC0) Characteristics The IF 962-COM interface submodule is used to connect devices with a serial port. It contains two serial A T -compatible ports (COMa, COMb). Up to four COM p[...]

  • Страница 507

    Interface Submodules 13-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.4.1 Pin Assignments Socket X1, X2 COMa, COMb T able 13-8 Socket X1, X2 IF 962-COM (9-Pin Sub D Plug Connector) 1 DCD Receive signal level Input 2 RxD Receive data Input 3 TxD Transmitted data Output 4 DTR Data terminal ready Output 5 Signal G[...]

  • Страница 508

    Interface Submodules 13-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.4.2 Addressing and Interrupts Addressing The IF 962-COM interface submodule can be addressed in the following two ways: • In the A T -compatible I/O address area • In the M7-300/400-reserved I/O address area (from C000 H ). Addressing in t[...]

  • Страница 509

    Interface Submodules 13-13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Addressing in the M7-300/400-Reserved I/O Address Ares Regardless of possible addresses in the A T -compatible I/O address area, the IF 962-COM interface submodule can be addressed in this reserved address area. The base address depends on the in[...]

  • Страница 510

    Interface Submodules 13-14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 13-13 Meaning of the Addressing T ype Bits in the Configuration Register (IF 962-COM) I/O Address Addressing T ype COM b/a I/O Address Bit 6/2 Bit 5/1 Bit 4/0 Addressing only possible in the reserved I/O address area (from C000 H ) (defaul[...]

  • Страница 511

    Interface Submodules 13-15 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Interrupt Request The interface submodule supplies an interrupt request (IRQa and IRQb) for each serial port. Y ou can define the assignment of the interrupt requests IRQa and IRQb to the appropriate processor interrupt requests in the BIOS Setup[...]

  • Страница 512

    Interface Submodules 13-16 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.5 IF 962-LPT Interface Submodule for M7-300/400; (6ES7962-4AA00-0AC0) Characteristics The IF 962-LPT interface submodule contains an A T -compatible parallel (LPT) port for connecting a printer with Centronics interface. The IF962-LPT submodul[...]

  • Страница 513

    Interface Submodules 13-17 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.5.1 Pin Assignments X1 Socket T able 13-15 Socket X1, IF 962-LPT (25-Pin Sub D Socket Connector) Pin Meaning Direction 1 /STROBE Input/output 2 Data 0 Input/output 3 Data 1 Input/output 4 Data 2 Input/output 5 Data 3 Input/output 6 Data 4 Inpu[...]

  • Страница 514

    Interface Submodules 13-18 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.5.2 Addressing and Interrupts Addressing The IF 962-LPT interface submodule can be addressed in the following two ways: • In the A T -compatible I/O address area • In the M7-300/400-reserved I/O address area (from C000 H ) Addressing in th[...]

  • Страница 515

    Interface Submodules 13-19 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Example of Setting an A T -Compatible I/O Address In the following example, the I/O address 0278 H is to be set in the BIOS setup. Proceed as follows to do this: 1. Select the “IF Modules” page in the BIOS setup. 2. Enter the submodule recept[...]

  • Страница 516

    Interface Submodules 13-20 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Default Settings in the BIOS The following I/O addresses and interrupt numbers are set as defaults in the BIOS for LPT ports: Port I/O Address Interrupt No. With mass storage module MSM 478 LPT1 (on MSM 478) 03BCH 7 LPT2 (IF 962-LPT) 0378H 5 With[...]

  • Страница 517

    Interface Submodules 13-21 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 13-20 Meaning of the Addressing T ype Bits in the Configuration Register (IF 962-LPT) I/O Address Addressing T ype I/O Address Bit 1 Bit 0 Addressing only possible in the reserved I/O address area (fromC000 H ) (default) 0 0 378 H 0 1 278 [...]

  • Страница 518

    Interface Submodules 13-22 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.5.3 T echnical Specifications T echnical Specifications The IF 962-LPT interface submodule receives its supply voltage from the M7-400 programmable modules or from the M7-300/400 expansion modules. The current consumption given in the technica[...]

  • Страница 519

    Interface Submodules 13-23 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.6 IF 961-DIO Interface Submodule for M7-300/400; (6ES7961-1AA00-0AC0) Characteristics The IF 961-DIO interface submodule has the following characteristics: • 8 inputs, isolated in groups of 2 Input level 24 VDC; 8.5 mA Input interrupt at ris[...]

  • Страница 520

    Interface Submodules 13-24 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.6.1 Pin Assignments X1 Socket There is a 25-pin sub D socket connector on the frontside of the submodule for plugging in the connecting cable. Figure 13-6 shows the pin assignments of the submodule. 13 5M 12 5L+ 1 1 DO0 10 DO1 9 DO2 8 DO3 76 M[...]

  • Страница 521

    Interface Submodules 13-25 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Figures 13-7 and 13-8 show the circuit block diagrams and the terminal connection diagrams for wiring the digital inputs and digital outputs. T erminal connection diagram Circuit block diagram Internal data bus M internal 13 5M 12 5L+ 1 1 DO0 10 [...]

  • Страница 522

    Interface Submodules 13-26 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.6.2 Addressing and Interrupts Addressing in the M7-300/400-Reserved I/O Address Area The base address depends on the interface submodule slot in the expansion module or the programmable module. See the descriptions “M7-300 Expansions”, “[...]

  • Страница 523

    Interface Submodules 13-27 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Digital Output Function T ables 13-24 and 13-25 give an overview of the digital output function. T able 13-24 Offset Address for the Digital Output Function (IF 961-DIO) Offset Address Function Remarks 1 User data digital output function Read/wri[...]

  • Страница 524

    Interface Submodules 13-28 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Interrupt Register The cause of the interrupt is stored in this register . T ables 13-28 and 13-29 give an overview of the interrupt register . T able 13-28 Offset Address for the Interrupt Register (IF 961-DIO) Offset Address Function Remarks 3 [...]

  • Страница 525

    Interface Submodules 13-29 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Selection Register Rising Edge T ables 13-32 and 13-33 give an overview of the selection register for interrupt generation at a rising edge of a digital input. T able 13-32 Offset Address for the Selection Register Rising Edge (IF 961-DIO) Offset[...]

  • Страница 526

    Interface Submodules 13-30 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Mode Register T ables 13-36 and 13-37 give an overview of the mode register . T able 13-36 Offset Address for the Mode Register (IF 961-DIO) Offset Address Function Remarks 7 Mode register Read/write T able 13-37 Meaning of the Bits in the Mode R[...]

  • Страница 527

    Interface Submodules 13-31 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.6.3 T echnical Specifications T echnical Specifications The IF 961-DIO interface submodule receives its supply voltage from the M7-400 programmable modules or from the M7-300/400 expansion modules. The current consumption given in the technica[...]

  • Страница 528

    Interface Submodules 13-32 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Status, Interrupts, Diagnostics Status indicated Interrupt Diagnostic functions – 1 sum interrupt from up to 8 sources No Data for Selecting a Sensor Input voltage • Nominal value • For signal “1” • For signal “0” 24 VDC from 13 V[...]

  • Страница 529

    Interface Submodules 13-33 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7 IF 961-AIO Interface Submodule for M7-300/400; (6ES7961-2AA00-0AC0) Characteristics The IF 961-AIO interface submodule has the following characteristics: • 4 analog inputs, each as voltage and current input • 2 analog outputs, each as vo[...]

  • Страница 530

    Interface Submodules 13-34 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7.1 Pin Assignments and T erminal Connection Diagram X1 Socket There is a 25-pin sub D socket connector on the frontside of the submodule for plugging in the connecting cable. Figure 13-10 shows the assignments for the X1 socket and the termin[...]

  • Страница 531

    Interface Submodules 13-35 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Meaning of Signals The following table shows the meanings of the signals in Figure 13-10. T able 13-38 Meaning of the Signals of the X1 Socket of the IF 961-AIO Interface Submodule Signal Meaning MV 0+ ... MV 3+ Analog inputs: V oltage MI 0+ ... [...]

  • Страница 532

    Interface Submodules 13-36 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Grounding for the Analog Inputs If the valid Common Mode area (V CM ) cannot be retained, the analog inputs must be grounded. T o do this, the ground lines of the individual analog inputs (1) and the shielding must be routed to the grounding poin[...]

  • Страница 533

    Interface Submodules 13-37 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7.2 Connecting Measured V alue Sensors to Analog Inputs Introduction Depending on the measuring type, you can connect various measured value sensors to the analog inputs: • V oltage sensors • Current sensors as – two-wire transducers –[...]

  • Страница 534

    Interface Submodules 13-38 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Isolated Measured V alue Sensors Potential differences can occur between the individual measured value sensors in the case of isolated measured value sensors. These potential differences can occur as the result of interference or the physical dis[...]

  • Страница 535

    Interface Submodules 13-39 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Non-Isolated Measured V alue Sensors Potential differences must not arise between non-isolated measured value sensors. If necessary , you must take additional installation measures (equipotential bonding conductor) to ensure this. Figure 13-14 sh[...]

  • Страница 536

    Interface Submodules 13-40 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Connection of Current Sensors as T wo-Wire and Four-Wire T ransducers Figures 13-16 and 13-17 show you how to connect current sensors as two-wire and four-wire transducers to analog input modules. The 24 V voltage is supplied to the two-wire tran[...]

  • Страница 537

    Interface Submodules 13-41 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Connection of Resistance Thermometers (e.g. Pt 100) and Resistances The resistance thermometers/resistances are measured in a 4-wire connection. A constant current I C which can be set is supplied to the resistance thermometers/ resistances via o[...]

  • Страница 538

    Interface Submodules 13-42 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7.3 Connecting Loads/Actuators to Analog Outputs Abbreviations Used The abbreviations used in Figures 13-20 to 13-21 have the following meanings: QI: Analog output current QV : Analog output voltage S: Reference potential of the analog circuit[...]

  • Страница 539

    Interface Submodules 13-43 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Connecting Loads to the V oltage Output The following figure shows the wiring of two channels as an example. +24 V R L1 L + QV 1 S 1 Ground bus QV 0 S 0 R L2 M 0 V V CM1 V CM0 Figure 13-21 Connecting Loads/Actuators via a Three-Wire Connection to[...]

  • Страница 540

    Interface Submodules 13-44 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7.4 Conversion Time and Cycle Time of the Analog Input Channels Introduction This section contains the definitions of and relationships between the conversion time and the cycle time of analog input modules. Conversion Time The conversion time[...]

  • Страница 541

    Interface Submodules 13-45 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7.5 Conversion Time, Cycle T ime, Settling Time, and Response Time of the Analog Output Channels Introduction This section contains the definitions and relationships of times relevant to the analog output modules. Conversion Time The conversio[...]

  • Страница 542

    Interface Submodules 13-46 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7.6 Starting Up the IF 961-AIO Interface Submodule Electrical Installation Y ou must connect the ground terminal (M and S 0/ S 1 ) of the analog input/output module with the ground terminal of the load power supply . Use a cable with a cross-s[...]

  • Страница 543

    Interface Submodules 13-47 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7.8 Analog Output Function Analog Output Function The 12-bit digital value to be converted is loaded left-justified into the DAC data registers of the relevant DAC channel. After the data has been written into the register , digital-analog con[...]

  • Страница 544

    Interface Submodules 13-48 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7.9 Analog Input Function Analog Input Function T ables 13-41 ad 13-42 contain an overview of the read and write registers for the analog input function. The data format of analog input values is a 16-bit value in two’s complement. Y ou can [...]

  • Страница 545

    Interface Submodules 13-49 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T able 13-42 Meaning of the Control Bits in the Analog Input Function (IF 961-AIO) Offset Address D15 Writing D0 Remark 08 H A C I N T 0 0 0 0 0 0 0 0 0 0 0 ta ta ta Control register 1 0A H 0 000000000000 ADC channel no. Control register 2 0C H 0[...]

  • Страница 546

    Interface Submodules 13-50 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Cyclic Conversion of the ADC Channels Below are listed the steps required for cyclic conversion of the ADC channels: 1. Set the AC bit in control register 1 to “1” (offset address “08 H ”). 2. W ait for interrupt. 3. Read the values at th[...]

  • Страница 547

    Interface Submodules 13-51 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7.10 Analog V alue Representation for the Measuring Ranges of the Analog Inputs V oltage and Current Measuring Ranges T able 13-43 contains the representation of the digitized measured value for • The voltage measuring range ± 10 V and • [...]

  • Страница 548

    Interface Submodules 13-52 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7.1 1 Analog V alue Representation for the Measuring Ranges of the Analog Outputs V oltage and Current Output Ranges T able 13-44 contains the representation of • The voltage output range ± 10 V and • The current output range ± 20 mA. T [...]

  • Страница 549

    Interface Submodules 13-53 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7.12 Diagnostics, Interrupts, and Submodule ID Interrupt Request The interface submodule supplies an interrupt request (IRQa). Y ou can define the assignment of the IRQa interrupt request to the relevant processor interrupt request in the BIOS[...]

  • Страница 550

    Interface Submodules 13-54 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.7.13 T echnical Specifications T echnical Specifications The IF 961-AIO interface submodule receives its supply voltage from the M7-400 programmable modules or from the M7-300/400 expansion modules. The current consumption given in the technic[...]

  • Страница 551

    Interface Submodules 13-55 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Interference Suppression, Error Limits for Inputs Interference voltage suppression for f = n (50/60 Hz " 1 %) n = 1, 2, ... • Common-mode interference (V pp < 1 V) • Normal-mode interference (Peak value of interference < nominal va[...]

  • Страница 552

    Interface Submodules 13-56 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.8 IF 961-CT1 Interface Submodule for M7-300/400; (6ES7961-3AA00-0AC0) Characteristics The IF 961-CT1 interface submodule is used for connecting incremental encoders. It has the following characteristics: • Connection with RS422 or 24 V signa[...]

  • Страница 553

    Interface Submodules 13-57 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.8.1 What Can the IF961-CT1 Interface Submodule Do? Introduction This section contains an overview of the functionality of the IF 961-CT1 interface submodule. This functionality is achieved using the relevant driver software. What Can the IF 96[...]

  • Страница 554

    Interface Submodules 13-58 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Interrupts The IF 961-CT1 can initiate an interrupt when comparison values are reached or in the event of overflow , underflow , or zero pass of the counter . Diagnostic Interrupt The IF 961-CT1 can initiate a diagnostic interrupt for the followi[...]

  • Страница 555

    Interface Submodules 13-59 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.8.2 Addressing and Interrupts Addressing The IF 961-CT1 interface submodule is addressed with the M7-300/400-reserved I/O address area (starting from C000 H ). Addressing in the M7-300/400-Reserved I/O Address Area The base address depends on [...]

  • Страница 556

    Interface Submodules 13-60 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.8.3 T echnical Specifications T echnical Specifications The IF 961-CT1 interface submodule receives its supply voltage from the M7-400 programmable modules or from the M7-300/400 expansion modules. The current consumption given in the technica[...]

  • Страница 557

    Interface Submodules 13-61 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.9 IF 964-DP Interface Submodule for S7-400 and M7-400 Order Numbers Y ou can use the IF 964-DP interface submodule with order number 6ES7964-2AA00-0AB0 (up to 07/99) in the M7-400. Y ou can use the IF 964-DP interface submodule with order numb[...]

  • Страница 558

    Interface Submodules 13-62 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Additional Front Cover The IF 964-DP interface submodule with order number 6ES7964-2AA01-0AB0 has an additional front cover , which is similar to the front cover of the IF 960HF synchronization submodule. As long as this second front cover is not[...]

  • Страница 559

    Interface Submodules 13-63 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.9.1 Pin Assignments X1 Connector There is a 9-pin sub D socket connector on the frontside of the submodule for plugging in the connecting cable. See T able 13-45 for the pin assignments. T able 13-45 X1 Socket, IF 964-DP (9-Pin Sub D Connector[...]

  • Страница 560

    Interface Submodules 13-64 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.9.2 Addressing and Interrupts In the M7-300/400-Reserved I/O Address Area The base address depends on the interface submodule slot in the expansion module or the programmable module. See the descriptions “M7-300 Expansions”, “M7-400 Expa[...]

  • Страница 561

    Interface Submodules 13-65 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 13.9.3 T echnical Specifications T echnical Specifications The IF 964-DP interface submodule receives its supply voltage in the S7-400 from the central processing unit and in the M7-400 from the programmable modules or from the expansion modules.[...]

  • Страница 562

    Interface Submodules 13-66 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07[...]

  • Страница 563

    A-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Parameter Sets for Signal Modules Chapter Overview Section Description Page A.1 How to Assign the Parameters for Signal Modules in the User Program A-2 A.2 Parameters of the Digital Input Modules A-4 A.3 Parameters of the Digital Output Modules A-7 A.4 Parameters of th[...]

  • Страница 564

    Parameter Sets for Signal Modules A-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 A.1 How to Assign the Parameters for Signal Modules in the User Program Parameter Assignment in the User Program Y ou have already assigned parameters to the modules in STEP 7 . In the user program, you can use a SFC: • to reassign p[...]

  • Страница 565

    Parameter Sets for Signal Modules A-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Description of the Parameters The following sections contain all the modifiable parameters for the various module classes. The parameters of the signal modules are described: • in the online help of STEP 7 . • in this reference man[...]

  • Страница 566

    Parameter Sets for Signal Modules A-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 A.2 Parameters of the Digital Input Modules Parameters The table below contains all the parameters you can set for digital input modules. Y ou will see which parameters you can modify from the list: • in STEP 7 • with SFC 55 ”WR_[...]

  • Страница 567

    Parameter Sets for Signal Modules A-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Byte 0 76 0 Hardware interrupt enable Diagnostic interrupt enable Byte 1 76 0 On rising edge at channel 0 On rising edge at channel 2 On rising edge at channel 4 On rising edge at channel 6 5 4321 Hardware interrupt On rising edge at c[...]

  • Страница 568

    Parameter Sets for Signal Modules A-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 The figure below shows the structure of data record 1 (bytes 4, 5 and 6) for the parameters of the digital input modules. Y ou enable a parameter by setting the corresponding bit to “1”. Byte 4 76 0 On falling edge at channel 9 On [...]

  • Страница 569

    Parameter Sets for Signal Modules A-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 A.3 Parameters of the Digital Output Modules Parameters The table below contains all the parameters you can set for digital output modules. The comparison shows: • Which parameters you can change with STEP 7 and • Which parameters [...]

  • Страница 570

    Parameter Sets for Signal Modules A-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Structure of Data Record 1 The figure below shows the structure of data record 1 (bytes 0, 1 and 2) for the parameters of the digital output modules. Y ou enable a parameter by setting the corresponding bit to “1”. Byte 0 76 0 Diag[...]

  • Страница 571

    Parameter Sets for Signal Modules A-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 The figure below shows the structure of data record 1 (bytes 3 and 4) for the parameters of the digital output modules. Y ou enable a parameter by setting the corresponding bit to “1”. Byte 3* 76 0 5 4321 Byte 4* 76 0 Enable substi[...]

  • Страница 572

    Parameter Sets for Signal Modules A-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 A.4 Parameters of the Analog Input Modules Parameters The table below contains all the parameters you can set for analog input modules. Y ou will see which parameters you can modify from the list: • in STEP 7 • with SFC 55 ”WR_P[...]

  • Страница 573

    Parameter Sets for Signal Modules A-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Structure of Data Record 1 The figure below shows the structure of data record 1 for the parameters of the analog input modules. Y ou enable a parameter by setting the corresponding bit to “1”. Byte 0 76 0 Diagnostic interrupt en[...]

  • Страница 574

    Parameter Sets for Signal Modules A-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07[...]

  • Страница 575

    B-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Diagnostic Data of the Signal Modules Chapter Overview Section Description Page B.1 Evaluating the Diagnostic Data of the Signal Modules in the User Program B-2 B.2 Structure and Contents of Diagnostic Data Bytes 0 and 1 B-3 B.3 Diagnostic Data of the Digital Input Mod[...]

  • Страница 576

    Diagnostic Data of the Signal Modules B-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 B.1 Evaluating the Diagnostic Data of the Signal Modules in the User Program In This Appendix This Appendix describes the structure of the diagnostic data in the system data. Y ou must be familiar with this structure if you want to[...]

  • Страница 577

    Diagnostic Data of the Signal Modules B-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 B.2 Structure and Contents of Diagnostic Data Bytes 0 and 1 The structure and contents of the different bytes of the diagnostic data are described below . The following general rule applies: When an error occurs, the bit concerned [...]

  • Страница 578

    Diagnostic Data of the Signal Modules B-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 B.3 Diagnostic Data of the Digital Input Modules as of Byte 2 The structure and contents of the different bytes of the diagnostic data for special digital input modules are described below . The following general rule applies: When[...]

  • Страница 579

    Diagnostic Data of the Signal Modules B-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 4 to 8 of the SM 421; DI 16 24 VDC Byte 4 76 0 5 4321 Byte 5 70 Channel type B#16#70: digital input Number of diagnostics bits that the module outputs per channel: 8 bits long Byte 6 70 Number of channels of the same type in [...]

  • Страница 580

    Diagnostic Data of the Signal Modules B-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 2 and 3 of the SM 421; DI 16 24/60 VUC Byte 2 76 0 Operating status 0: RUN 1: STOP 5 4321 0 Byte 3 76 0 EPROM error Hardware interrupt lost 54 3 2 1 0 0 000 0 0 00 0 0 0 Figure B-5 Bytes 2 and 3 of the Diagnostic Data of the [...]

  • Страница 581

    Diagnostic Data of the Signal Modules B-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 9 to 24 of the SM 421; DI 16 24/60 VUC Data record 1 with bytes 9 to 24 contains the channel-specific diagnostic data. The figure below shows the assignment of the diagnostic byte for a channel of the module. 76 0 5 4321 0 0 [...]

  • Страница 582

    Diagnostic Data of the Signal Modules B-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 B.4 Diagnostic Data of the Digital Output Modules as of Byte 2 The structure and contents of the different bytes of the diagnostic data for special digital output modules are described below . The following general rule applies: Wh[...]

  • Страница 583

    Diagnostic Data of the Signal Modules B-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 4 to 8 of the SM 422; DO 16 20-125 VDC/1.5 A Byte 4 76 0 5 4321 Byte 5 70 Channel type B#16#72: digital output Number of diagnostics bits that the module outputs per channel: 8 bits long Byte 6 70 Number of channels of the sa[...]

  • Страница 584

    Diagnostic Data of the Signal Modules B-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 2 and 3 of the SM 422; DO 32 24 VDC/0.5 A Byte 2 76 0 Operating status 0: RUN 1: STOP Module-internal supply voltage failure 5 4321 0 Byte 3 76 0 EPROM error 54 3 2 1 0 0 0 00 0 000 00 0 Figure B-1 1 Bytes 2 and 3 of the Dia[...]

  • Страница 585

    Diagnostic Data of the Signal Modules B-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 4 to 10 of the SM 422; DO 32 24 VDC/0.5 A Byte 4 76 0 5 4321 Byte 5 70 Channel type B#16#72: digital output Number of diagnostics bits that the module outputs per channel: 8 bits long Byte 6 70 Number of channels of the sam[...]

  • Страница 586

    Diagnostic Data of the Signal Modules B-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 1 1 to 42 of the SM 422; DO 32 24 VDC/0.5 A Data record 1 with bytes 1 1 to 42 contains the channel-specific diagnostic data. The figure below shows the assignment of the diagnostic byte for a channel of the module. 76 0 Sho[...]

  • Страница 587

    Diagnostic Data of the Signal Modules B-13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 4 to 8 of the SM 422; DO 16 20-120 V AC/2 A Byte 4 76 0 5 4321 Byte 5 70 Channel type B#16#72: digital output Number of diagnostics bits that the module outputs per channel: 8 bits long Byte 6 70 Number of channels of the sa[...]

  • Страница 588

    Diagnostic Data of the Signal Modules B-14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 B.5 Diagnostic Data of the Analog Input Modules as of Byte 2 The structure and contents of the different bytes of the diagnostic data for the special analog input modules are described below . The following general rule applies: W[...]

  • Страница 589

    Diagnostic Data of the Signal Modules B-15 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 4 to 8 of the SM 431; AI 16 16 Bit Byte 4 76 0 5 4321 Byte 5 70 Channel type B#16#71: analog input Number of diagnostics bits that the module outputs per channel: 8 bits long Byte 6 70 Number of channels of the same type in [...]

  • Страница 590

    Diagnostic Data of the Signal Modules B-16 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 2 and 3 of the SM 431; AI 8 RTD 16 Bit Byte 2 76 0 Operating status 0: RUN 1: STOP 5 4321 0 Byte 3 76 0 EPROM error ADC/DAC error Hardware interrupt lost 54 3 2 1 0 0 000 0 00 0 0 0 Figure B-20 Bytes 2 and 3 of the Diagnosti[...]

  • Страница 591

    Diagnostic Data of the Signal Modules B-17 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 8 to 23 of the SM 431; AI 8 RTD 16 Bit Data record 1 with bytes 8 to 23 contains channel-specific diagnostic data. The following figure shows the assignment of the even diagnostic bytes (bytes 8, 10, to 22) for a channel of [...]

  • Страница 592

    Diagnostic Data of the Signal Modules B-18 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 2 and 3 of the SM 431; AI 8 16 Bit Byte 2 76 0 Operating status 0: RUN 1: STOP 5 4321 0 Byte 3 76 0 EPROM error ADC/DAC error Hardware interrupt lost 54 3 2 1 0 0 000 0 00 0 Thermocouple connection error RAM error Figure B-2[...]

  • Страница 593

    Diagnostic Data of the Signal Modules B-19 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bytes 8 to 23 of the SM 431; AI 8 16 Bit Data record 1 with bytes 8 to 23 contains channel-specific diagnostic data. The following figure shows the assignment of the even diagnostic bytes (bytes 8, 10, to 22) for a channel of the [...]

  • Страница 594

    Diagnostic Data of the Signal Modules B-20 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07[...]

  • Страница 595

    C-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Spare Parts and Accessories Spare Parts and Accessories For Racks Number wheel for slot labeling C79165-Z1523-A22 Spare slot covers (qty 10) 6ES7490-1AA00-0AA0 For Power Supplies Spare connector for PS 405 (DC) 6ES7490-0AA00-0AA0 Spare connector for PS 407 (AC) 6ES7490[...]

  • Страница 596

    Spare Parts and Accessories C-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 For IMs T erminating connector for IM 461-0 6ES7461-0AA00-7AA0 T erminating connector for IM 461-1 6ES7461-1AA00-7AA0 T erminating connector for IM 461-3 6ES7461-3AA00-7AA0 IM 463-2, send IM, 600 m to IM 314 of the S5 6ES7463-2AA00-0AA0 IM c[...]

  • Страница 597

    Spare Parts and Accessories C-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Cables Connecting cables for printers with • Serial port (COM, 10 m) • Parallel port (Centronics) 9AB4173-2BN10-0CA0 6AP1901-0AL00 Connecting cable for interface module • 1 6ES7368 3BB00 0AA0 g • 1 m • 25 m 6ES7368-3BB00-0AA0 6ES73[...]

  • Страница 598

    Spare Parts and Accessories C-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07[...]

  • Страница 599

    D-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Guidelines for Handling Electrostatic Sensitive Devices (ESD) Introduction In this appendix, we explain • what is meant by “electrostatic sensitive devices” • the precautions you must observe when handling and working with electrostatic sensitive devices. Chapt[...]

  • Страница 600

    Guidelines for Handling Electrostatic Sensitive Devices (ESD) D-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 D.1 What is ESD? Definition All electronic modules are equipped with large-scale integrated ICs or components. Due to their design, these electronic elements are very sensitive to overvoltages and thus to an[...]

  • Страница 601

    Guidelines for Handling Electrostatic Sensitive Devices (ESD) D-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 D.2 Electrostatic Charging of Persons Charging Every person with a non-conductive connection to the electrical potential of its surroundings can be charged electrostatically . Figure D-1 shows you the maximu[...]

  • Страница 602

    Guidelines for Handling Electrostatic Sensitive Devices (ESD) D-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 D.3 General Protective Measures Against Electrostatic Discharge Damage Ensure Sufficient Grounding Make sure that the personnel, working surfaces and packaging are sufficiently grounded when handling electro[...]

  • Страница 603

    E-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 List of Abbreviations Abbreviation Explanation AC Alternating current ADC Analog to digital converter AI Aanalog input AO Analog output AS Automation system BAF Battery failure BUSF1; BUSF2 LED – bus failure on the MPI/Profibus DP interface 1 or 2 CD Central device C[...]

  • Страница 604

    List of Abbreviations E-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 FC Function FEPROM Flash erasable programmable read only memory FM Function module FOC Fiber-optic cable FRCE Force GD Global data communication I C Constant-current lead ID Input delay IFM1F; IFM2F LED error at interface module 1/2 IM Interface m[...]

  • Страница 605

    List of Abbreviations E-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 S + Sensor lead (positive) S – Sensor lead (negative) SCL Structured control language SP Sensor power SF “Group error” LED SFB System function block SFC System function SM Signal module SSI Synchronous serial interface SSL System status list[...]

  • Страница 606

    [...]

  • Страница 607

    Glossary-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Glossary Address An address denotes a specific operand or address area; examples of this are: input I 12.1; memory word MW 25; data block DB 3. Aggregate current Sum of the currents of all output channels on a digital output module. Backplane bus The backplane b[...]

  • Страница 608

    Glossary Glossary-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Bus connector A physical connection between the bus nodes and the bus cable. Bus segment A bus segment is a self-contained section of a serial bus system. Bus segments are interconnected by means of ³ repeaters. Central controller An S7-400 consists of[...]

  • Страница 609

    Glossary Glossary-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Comparison point Parameter in STEP 7 for analog input modules. Using this parameter , you can determine the reference junction (the point where the temperature is known) when thermocouples are used. The following can be reference junctions: resistance t[...]

  • Страница 610

    Glossary Glossary-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Declaration Assigning variables (parameters or local data of a block, for example) with a name, data type, comment, etc. Default setting The default setting is a sensible basic setting that is used whenever no other value is used. Destination CPU for in[...]

  • Страница 611

    Glossary Glossary-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Direct communication Direct communication involves assigning local input address areas of an intelligent DP slave (for example, CPU 315-2 with PROFIBUS DP connection) or of a DP master to the input address areas of a PROFIBUS DP partner . The intelligen[...]

  • Страница 612

    Glossary Glossary-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Equipotential bonding An electrical connection (equipotential bonding conductor) that brings the bodies of electrical resources and foreign conductive bodies to an identical or approximately identical potential in order to avoid interfering or hazardous[...]

  • Страница 613

    Glossary Glossary-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Function A function (FC) in accordance with IEC 1 131-3 is a ³ code block without ³ static data. A function allows parameters to be passed in the user program. Functions are therefore suitable for programming complex functions, such as calculations th[...]

  • Страница 614

    Glossary Glossary-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Ground, to T o ground means to connect an electrically conductive part via a grounding system to the grounding electrode (one or more conductive parts having a very good contact to ground). Hardware interrupt A hardware interrupt is triggered by interru[...]

  • Страница 615

    Glossary Glossary-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Interrupt, diagnostic ³ Diagnostic Interrupt Interrupt, end-of-scan-cycle ³ Hardwareinterrupt Interrupt, hardware ³ Hardware interrupt Interrupt response time The interrupt response time is the time from when an interrupt signal first occurs to calli[...]

  • Страница 616

    Glossary Glossary-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Local data Local data are data assigned to a ³ code block that is declared in its ³ declaration section and its variable declaration. It includes (depending on the block): formal parameters, ³ static data, ³ temporary data. Logic block In the conte[...]

  • Страница 617

    Glossary Glossary-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Measuring range module Measuring range modules are plugged into the analog input modules for adaptation to different measuring ranges. Memory card Pluggable load memory . Memory cards are credit-card size storage media for CPUs and CPs. They are imple[...]

  • Страница 618

    Glossary Glossary-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Non-isolated In the case of non-isolated input/output modules, the reference potentials of the control and load circuit are electrically connected. OB ³ Organization block Organization block Organization blocks (OBs) form the interface between the ope[...]

  • Страница 619

    Glossary Glossary-13 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Priority class The operating system of an S7 CPU has a maximum of 28 priority classes (= program execution levels) – for cyclic program scanning or program scanning controlled by hardware interrupt, for example. Each priority class is assigned ³ org[...]

  • Страница 620

    Glossary Glossary-14 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Programming device A programming device (PG) is an industry-standard, compact personal computer . A PG is completely equipped for programming SIMA TIC programmable controllers. Protection level The SIMA TIC S7 access protection concept prevents the cen[...]

  • Страница 621

    Glossary Glossary-15 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Reference channel error Parameter in STEP 7 for analog input modules. Using this parameter , you can enable the group error message of the reference junction when thermocouples are used. A reference channel error occurs when thermocouples are used and [...]

  • Страница 622

    Glossary Glossary-16 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Restart When a CPU starts up (through the use of the mode selector , for example, or when the power is switched on), either OB 101 (restart), OB 100 (reboot: warm restart) or OB 102 (cold restart) is processed before cyclic program scanning (OB 1). It [...]

  • Страница 623

    Glossary Glossary-17 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Sequence layer Sequence layers form the interface in M7 between the operating system of the CPU and the user program. The order in which the blocks of the user program are processed is defined in the sequence layers. SFB ³ System function block SFC ³[...]

  • Страница 624

    Glossary Glossary-18 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 ST ARTUP The ST ARTUP mode is traversed during the transition from ST OP mode to RUN mode. ST ARTUP can be triggered by the ³ mode selector or following power-on or by means of an operator input on the programming device. Rebooting and restarting are [...]

  • Страница 625

    Glossary Glossary-19 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 System function block A system function block (SFB) is a ³ function block integrated in the operating system of the CPU that can be called in the STEP 7 user program like a function block (FB), as required. The associated instance data block is in wor[...]

  • Страница 626

    Glossary Glossary-20 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 W arm restart This is a reboot after a power failure using a set of dynamic data programmed by the user and a user program section defined in the system. A warm restart is indicated by setting a status bit or by some other appropriate means that can be[...]

  • Страница 627

    Index-1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Index A Accessories, C-1 Accessories, M7-400, memory card, 1 1-8 Actuator connection, to analog output module, 5-59 Actuators, connecting, 13-42 ADC-DAC error , analog input module, 5-66 Address, Glossary-1 Address area, setting, 7-9 Address assignment, M7-400, CPU[...]

  • Страница 628

    Index Index-2 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Analog output channel conversion time, 5-37 response time, 5-38 Analog output module connecting loads and actuators, 5-59 connecting loads to current output, 5-62 connecting loads to voltage output, 5-60 isolated, 5-59 output, 5-42 output range, 5-42 output t[...]

  • Страница 629

    Index Index-3 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Communication bus, 2-5 Communication load, Glossary-2 Communication processor , Glossary-2 Comparison point, 5-57, Glossary-3 Compensating box, 5-55, Glossary-3 connecting, 5-56 Compensation external, 5-55 internal, 5-55, 5-56 Config. index, M7-400, 1 1-27 Co[...]

  • Страница 630

    Index Index-4 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Diagnostics analog input module, 5-40 digital input module, 4-7 digital output module, 4-8 of analog modules, 5-63 of digital modules, 4-9 system, Glossary-18 Diagnostics entry , 5-32 Digital input module diagnostic data, B-4 diagnostic interrupt enable, 4-7 [...]

  • Страница 631

    Index Index-5 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Digital output module destination CPU for Interrupt, 4-8 diagnostic data, B-8 diagnostic interrupt enable, 4-8 diagnostics, 4-8 fuse blown, 4-8 keep last value, 4-8 no load voltage L+, 4-8 parameters, 4-8, A-7 short circuit to L+, 4-8 short circuit to M, 4-8 [...]

  • Страница 632

    Index Index-6 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Functional grounding, Glossary-7 Fuse blown, Glossary-7 digital module, 4-12 digital output module, 4-8 G Global data, Glossary-7 Ground, Glossary-7 Ground short circuit, analog input module, 5-66 Grounded operation, RS 485 repeater , 10-4 Grounding for the a[...]

  • Страница 633

    Index Index-7 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 IF 962-LPT , 13-16 addressing, 13-18 A T -compatible, 13-18 M7-300/400 reserved, 13-19 characteristics, 13-16 interrupt request, 13-21 pin assignments, 13-17 technical specifications, 13-22 IF 962-VGA, 13-5 addressing, 13-7 characteristics, 13-5 interrupts, 1[...]

  • Страница 634

    Index Index-8 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Interrupt-triggering channels, of the digital module, 4-14 Interrupts enabling, 4-13, 5-67 of analog modules, 5-67 of the digital modules, 4-13 INTF LED analog module, 5-63 digital module, 4-9 IP 20, 1-18 Isolated, Glossary-9 Isolated measuring sensor , 5-44 [...]

  • Страница 635

    Index Index-9 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Non-isolated sensors, 5-45 connecting, 5-45 O OB, Glossary-12 OB 40, 4-14, 5-68 start information, 5-68 OB 82, 4-13, 5-67 Operating conditions, 1-14 Operating mode, Glossary-12 of CPU, 5-31 Operating system, Glossary-12 Operational limit, 5-33 Order number 6E[...]

  • Страница 636

    Index Index-10 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 P ARM_MOD, SFC 57, A-2 Password, M7-400, 1 1-31 Performance features, M7-400, CPUs, 1 1-2 Permissible potential differences, 7-3 PG cable, 1 1-15, C-2 Pin assignment, RS 485 repeater , 10-6 PLC, Glossary-13 Point-to-point connection, Glossary-12 Potential di[...]

  • Страница 637

    Index Index-1 1 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 Sensor supply missing digital input module, 4-7 digital module, 4-12 Sensors, non-isolated, 5-45 Sequence layer , Glossary-17 Settling time, 5-38 analog output, 13-45 Setup fields, M7-400, 1 1-20 Setup page, M7-400 ”Boot Options”, 1 1-36 ”Date/T ime?[...]

  • Страница 638

    Index Index-12 S7-400, M7-400 Programmable Controllers Module Specifications A5E00069467-07 T T echnical specifications IF 961-AIO, 13-54 IF 961-DIO, 13-31 IF 962-COM, 13-15 IF 962-LPT , 13-22 IF 962-VGA, 13-8 IF 964-DP , 13-65 IM 460-0 and 461-0, 6-9 IM 460-1 and 461-1, 6-13 IM 460-3 and 461-3, 6-17 IM 460-4 and 461-4, 6-21 PS 405 10 A, 3-35 PS 40[...]