TANDBERG MXP инструкция обслуживания

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302

Идти на страницу of

Хорошее руководство по эксплуатации

Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации TANDBERG MXP. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции TANDBERG MXP или обучающее видео для пользователей. Условием остается четкая и понятная форма.

Что такое руководство?

Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции TANDBERG MXP можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.

К сожалению немного пользователей находит время для чтения инструкций TANDBERG MXP, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.

Из чего должно состоять идеальное руководство по эксплуатации?

Прежде всего в инструкции TANDBERG MXP должна находится:
- информация относительно технических данных устройства TANDBERG MXP
- название производителя и год производства оборудования TANDBERG MXP
- правила обслуживания, настройки и ухода за оборудованием TANDBERG MXP
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам

Почему мы не читаем инструкций?

Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск TANDBERG MXP это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок TANDBERG MXP и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта TANDBERG, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания TANDBERG MXP, как это часто бывает в случае бумажной версии.

Почему стоит читать инструкции?

Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства TANDBERG MXP, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.

После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции TANDBERG MXP. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.

Содержание руководства

  • Страница 1

    User Manual Software version F4 D13358.06 March 2006 This document is not to be reproduced in whole or in part without permission in writing from:[...]

  • Страница 2

    TANDBERG Maestro MXP ii Trademarks and Copyright All rights reserved. This document conta ins inform ation that is prop rietar y to TANDBERG. No part of this publication may be reproduced, st ored in a re trieval system, or transmitted, in any form, or by any means, electronically, mechani cally, by photocopying, or otherwise, without the prior wri[...]

  • Страница 3

    User Manual iii eCos eCos, the Embedded Configurable Operating S ystem. Copyright (C) 1998, 1999, 2000, 2001, 2002, 2003 Red Hat, Inc. Copyright (C) 2002, 2003 John Dallaway Copyright (C) 2002, 2003 Nick Garnett Copyright (C) 2002, 2003 Jonathan Larmou r Copyright (C) 2002, 2003 Andrew Lunn Cop yright (C) 2002, 2003 Gary Thomas Copyright (C) 2002, [...]

  • Страница 4

    TANDBERG Maestro MXP iv Disclaimer The information in this document is furnished for informational purp ose s only, is subject to change without prior notice , and should not be construed as a commitment by TANDBERG. The information in this document is believed to be accurate and reliable; however TANDBERG assumes no responsibility or liability for[...]

  • Страница 5

    User Manual v Environmental Issues TANDBERG visual communication pro d ucts signifi cantly reduce the need for travel and thereby help reduce various types of pollution. TANDBERG recomm ends the use of low energy peripherals, such as Energ y Star™ monit ors . Thank you for buying a TANDBERG product. Battery handling The batteries for the Remote C[...]

  • Страница 6

    TANDBERG Maestro MXP vi Operator Safety Summary For your protection, please read these safety instructions completely before op erating the equipment and keep this manual for futu re reference. The information in this summary is inte nded for operators. Carefully observe all wa rni ngs, pr ecautions and instructio ns both on the apparatus and in th[...]

  • Страница 7

    User Manual vii  ISDN cables - CAUTION - To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line co rd.  Servicing - Do not attempt to service th e apparatus yourself as opening or remov ing covers may expose you to dangerous vo ltages or other hazards, and will void the warranty. Refer all servicing to qualified serv[...]

  • Страница 8

    TANDBERG Maestro MXP viii Contact us If you have any questions, comments or suggestions, please se e the Online Support sectio n at www.tandberg.net . It is also possible to send a fa x or mail to the attention of: Product and Sales Support TANDBERG P.O. Box 92 1325 Lysaker Norway Tel: +47 67 125 125 Fax: +47 67 125 234[...]

  • Страница 9

    User Manual ix Table of Contents 1 Introduction ................................................................................................................... .......... 13 1.1 At a Glance ................................................................................................................ .......... 16 1.2 Menu St ructure .........[...]

  • Страница 10

    TANDBERG Maestro MXP x 3.11.7 Display S napshot ..................................................................................................... 90 3.12 Conference Services .......................................................................................................... 91 3.12.1 Request Floor and Release Floor .......................[...]

  • Страница 11

    User Manual xi 4.3.9 VNC Setti ngs ......................................................................................................... 163 4.4 Call Qu ality ......................................................................................................................... 164 4.4.1 Video Algor ithm.......................................[...]

  • Страница 12

    TANDBERG Maestro MXP xii 6.5 Appendi x 5 ................................................................................................................. ........ 270 6.6 Appendi x 6 ................................................................................................................. ........ 273 6.7 Appendi x 7 .......................[...]

  • Страница 13

    1 Introduction The TANDBERG Maestro MXP provides high-en d performance feature s, large monitors and precision audio. This creat es a collaborative meeting environment for medium to large-size d meeting rooms. Audio Quality High-performance audio provides a ri cher, more co mplete visual communication experie nce. The MPEG4 AAC-LD standard is used [...]

  • Страница 14

    TANDBERG Maestro MXP 14 Security Secure Conference TF provid es emb edded encryption for bot h Point-to-Point and MultiSite call and ensures both privacy and security. The system is delivered with integrated Expressway ™ firewall tra versal technology. When used together with a TANDBERG Border Co ntrolle r it enables:  Secure and seamless trav[...]

  • Страница 15

    Installation 15 Users can display video and presentations in the best layout based on the situation. Supported screen layouts are:  Picture in Picture (PiP)  Picture outside Picture (PoP )  Side by Side User interfaces A web-interface to the codec provides:  System management, diagnostics and software u ploa ds.  Text chat/closed cap[...]

  • Страница 16

    TANDBERG Maestro MXP 16 1.1 At a Glance WAVE II Camera The main camera is mounted on top of the pro du ct. The main cam era includes a high quality color camera with a fast pan/tilt/zoom action. The main camera is controlled by the system’s infrared remote control and operates pan /tilt, focu s an d zoom. Up to fifteen camera positions can be pre[...]

  • Страница 17

    Installation 17 Internal LCD Display The system has a built-in 5 inch LCD designed to opt i m ize sy stem configuration and give the use r access to menus and test video sig nals without a ttaching or powering an external display device. The LCD gives full control of all system setti ngs and status. Below the LCD there are three system indicators, [...]

  • Страница 18

    TANDBERG Maestro MXP 18 The reach of the remote control signal is 20 mete rs. For users sitting in an open plan office, this can cause problems. Use the little, white switch place d under the batteries to change the rea ch of the signal from 20 meters to 2 meters. This will prevent you from unintentionally controlling another video system, when y o[...]

  • Страница 19

    Installation 19 TANDBERG Tracker The tracker is a small infrared rem ote control device made to steer the camera to any desired location within the room. Typically, several trackers would b e use d with each system. Each tracker has t w o buttons :  One Single person button to point the camera at a specific pe rson/location.  One Group button[...]

  • Страница 20

    TANDBERG Maestro MXP 20 1.2 Menu Structure The menu structure is divided into two parts. The Mai n Menu is av ailable for all users and contains all the functionality of the system. The Ad ministrator Menu contains all the setting s of the system. The Administrator Settings are accessibl e fro m the Main M enu by selecting Control Panel and Adminis[...]

  • Страница 21

    Installation 21 Note that the system features and menu se ttings may vary dependi ng on network selection and software package.[...]

  • Страница 22

    TANDBERG Maestro MXP 22 2 Inst allation Precautions:  Never install communi cati on wiring during a lightnin g storm.  Never install ja c ks f or communicat ion c ables in wet locatio ns unless the ja c k is specifically designed for wet locations.  Never touch uninstalled co mmuni cation wires or terminals u nless the telephone li ne ha s[...]

  • Страница 23

    Installation 23 2.1 Unpacking and Mounting 1 Unpacking The TANDBERG Maestro is delivered in one transpo rt case with all component s inside. Remove the case in the order show n on Figure 1. Figure 1 The accessories box contains:  Wave II camera  2x Table Microphones  Remote Control and Tra cker with batte ri es  Documentation  Cables[...]

  • Страница 24

    TANDBERG Maestro MXP 24 Figure 3[...]

  • Страница 25

    Installation 25 2.2 Connecting Cables 1. Power cable Find the right power cable that works for your country i n the accessories box, and connect to power cable from base, and to an electrical di stributio n socket. 2. Microphone cable Connect the microphone cable to the micropho ne. 3. a) ISDN BRI Connect the ISDN cables to the ISDN sockets (S/T in[...]

  • Страница 26

    TANDBERG Maestro MXP 26 6. PC Connect cable from DVI-I in PC from the Codec to PC.[...]

  • Страница 27

    Installation 27 2.3 Monitor Configuration Configuration of external display (projector )  Select 16:9 or 4:3 format on the projector.  Make sure that the main projector is con nected to the DVI-I Single output on the codec. Please refer to the projector use r manual for further informatio n.[...]

  • Страница 28

    TANDBERG Maestro MXP 28 2.4 System Configuration The system must be configure d for each insta llation. Configuration settings can be made via the system menu. If an external IMUX or non-standar d network is being used it may be necessary to configure any associated external equi pment. Navigate through the menu system using the arro w ke ys and OK[...]

  • Страница 29

    Installation 29 5. Screen Settings When using wide scree n (16:9) mo nitors, set TV Monitor Format to Wide (16:9). TANDBERG also recommends setting Picture Layout to Picture outside Picture when using 16:9 monitors. Picture outside Pictur e provides a displ ay layout optimized for wide screen monitors. The display layout may be cha nged at any time[...]

  • Страница 30

    TANDBERG Maestro MXP 30 4. Network Profiles Please refer to Network Profiles for details 5. Data Port Please refer to Data Port for details 6. Save changes Remember to save any changes made in the menu b y selecting the Save button on the Menu line and pressing OK. * The International Name field is only vi sible if the system name contains Asian an[...]

  • Страница 31

    3 General Use Wake up the sy stem When the system is not in use, it is in st andby mode and the screens are black. Wa ke up the system by picking up the remote control. An incomi ng call or pressi ng any key o n the remote control will also wake up the system. If the system does not respond:  Make sure that the system is swit ched on. The red li[...]

  • Страница 32

    TANDBERG Maestro MXP 32 3.1 The Welcome Screen When the system is switched on, the welcome scre en will be displayed. The welcome screen presents the menu and displays your main cam era image in the background (display main camera is the default setting). The ISDN/IP num bers and the system name are displ ayed in the upper right corner. The ISDN Nu[...]

  • Страница 33

    General Use 33 3.2 Using the Remote Control The system is controlled with a remote control. Think of the remote control as a mobile phone with number keys and call keys. Use the arro w keys a nd press OK to navigate through the menus. The system’s most commonly used functions are al so accessible directly from the rem ote control. The Infra Red ([...]

  • Страница 34

    TANDBERG Maestro MXP 34 11. Use Zoom + and – to zoom the camera in and out.* 12. Selfview displays your outgoing video. Press Selfview again to turn selfview off, see Selfview . 13. Use the Phone Book to store and recall video contacts for easy placement of calls, see Phone Book . 14. Use the red End Call key to end the current call. Pressing thi[...]

  • Страница 35

    General Use 35 The remote control (TRC 4)**: 1. Change video source. If possible, you will start open a Dual Stream. Press the video source button again to stop the dual stream. 2. Mic Off turns your microphone on and off, see Mic off . 3. Arrow keys are used for navigation in the menu and for moving the camera* when the menu is hidden, see Navigat[...]

  • Страница 36

    TANDBERG Maestro MXP 36 presentation source. If the Presentation key is held down for 1 second then the Presentation video sources menu will appear, see Presentation Key . 12. Press OK/Menu to show the menu and to select menu items, see Navigation . 13. Use Zoom + and – to zoom the camera in and out.* 14. Selfview displays your outgoing video. Pr[...]

  • Страница 37

    General Use 37 3.2.1 Navigation Arrow keys and OK Navigate in the menu with the arrow key s on the remo te control. The orange selector on screen show s the selected item. Press OK to select. Cancel key In the main menu, pressing Cancel (X) will hide the menu. If the menu is hidden, bring it back with OK . In other menu s, pressing Can cel (X ) tak[...]

  • Страница 38

    TANDBERG Maestro MXP 38 3.2.2 Selfview The term “Selfview” means the outgoing image. In a normal call using the main camera, this is the image of yourself. The Selfview button toggles the images betwee n Far En d, Selfview and Dual Video (if any). How to use Selfview : 1. Outside a call, pressing the Selfview button will switch between the near[...]

  • Страница 39

    General Use 39 Example: You are using the system as a PC and get an incom ing call. When the setting “Use Screen as Local PC monitor” i s On, you will keep your PC image displayed locally and the incoming call pops up in a PIP or as sm aller images in a 1+3 layout, depending on your system. You will see Local PC displayed in the big picture and[...]

  • Страница 40

    TANDBERG Maestro MXP 40 3.2.3 Layout The layout of the screen can either be shown a s Pi cture in Picture (PIP) or Picture outsid e Picture (POP) when displaying more than one video imag e. The beh avior of the Layout button is dependent on the Picture Layout setting in Scre en Settings . 3.2.3.1 Picture in Picture When Picture Layout is set to PIP[...]

  • Страница 41

    General Use 41 3.2.4 Mic Off To mute the microphone during a call, press the Mic off button. An on-scree n in dicator appears in the upper right corner when the microphone is off. In a call, if audio is detected, the on-screen symbol will start to flash. Pressing the Mic o ff button one more time will activate the microphone again. A green LED belo[...]

  • Страница 42

    TANDBERG Maestro MXP 42 3.2.5 Volume + and - Press the Volume key to adjust the volume leve l. An on-screen indicato r will show the current level.[...]

  • Страница 43

    General Use 43 3.2.6 Number and Letter keys Pressing a number key when outsi de a call will bring up the call menu. Wh en in a call, the number keys are used for Camera Presets. Press a n umber and go to the corresponding Camera Preset (see Camera Presets ). However, when accessing an input field where numbers are required, the system automatically[...]

  • Страница 44

    TANDBERG Maestro MXP 44 3.2.7 Touch Tones To activate dialing touch tones during a call, press the Touch tone s butt on. Oth erwise the number keys will activate the corre spondi ng camera preset s. An indicato r will let you know that Touch tones are enabled. Finish with OK to exit Touch tone mode.[...]

  • Страница 45

    General Use 45 3.3 On-screen Indicators The system has a number of icons signaling diffe rent settings: Microphone Off This indicator is shown when the microphone is turned off. Press the Mic off button again to turn the microphone back on, see Mic Off for details. Volume Off This indicator is shown when the volume is turned off. Press Volume + to [...]

  • Страница 46

    TANDBERG Maestro MXP 46 Telephone This indicates that there is a telephone p articipant in the conference. The displayed number indicate s ho w many telephone participa nts there are in the conference.[...]

  • Страница 47

    General Use 47 3.4 Using the Menu Main menu outside a call and in a call. Press the Menu button on the remote co ntrol to displ ay the menu. The menu contains all functions needed in order to control the system.[...]

  • Страница 48

    TANDBERG Maestro MXP 48 The menu contains the following items:  Make a Call / Add Another Call  Standby / End Call  Camera Control  Presentation  Conference Service s  Control Panel  Close See Menu Structure for a full overview of the menu. The functions of the menu are displayed as icons. The curre ntly se lected icon is marke[...]

  • Страница 49

    General Use 49 3.5 Make a Call Display the call menu by either: 1. Select Make a Call from the menu, or 2. Press the green Call button on the remote cont rol The TANDBERG system can make both Video calls and Telephone calls . Call Settings specifies the quality of the call. It is possible to alter the default call settings for th e current call if [...]

  • Страница 50

    TANDBERG Maestro MXP 50 3.5.1 Place Video Call In the Make a Call menu, enter the Dial Number eith e r: 1. Manually, or 2. Select the book symbol in order to display the Phone Book and sel ect a co nference participant. When dialing manually, toggle between ABC/abc by pressing the # button on the remote control and between abc/123 by holding the # [...]

  • Страница 51

    General Use 51 3.5.2 Place Telephone Call In the Make a Call menu, enter the Dial Number eith e r: 1. Manually, or 2. Select the book symbol in order to di splay the Phone Book and select a conference participant, see Phone Book for details. When entering a Dial Number ma nually, toggle between abc/123 by pressing the # button on the remote control[...]

  • Страница 52

    TANDBERG Maestro MXP 52 3.5.3 Add Call (Optional feature) Conference systems with b uilt-in MultiSite can handle up to 6 video calls and 5 tel epho ne calls simultaneously. It is possible to both set up a conference with many participants and also ad d participants durin g a conference. Set up a conference w ith t wo or more participants In the Mak[...]

  • Страница 53

    General Use 53[...]

  • Страница 54

    TANDBERG Maestro MXP 54 3.5.4 Call Settings The Call Settings specifies the quality of the call. Each call will be set up with the Default Call Settings if the settings are not altered. In this ca se the field is labeled Default Call Settings. If the settings for some reason are altered for the current participant in the current call, the name of t[...]

  • Страница 55

    General Use 55 3.5.5 Streaming Streaming lets you broadcast your meeting to particip ants on the web. The web participant s can listen to the meeting, see snapshots, but not parti cipate themselves. Snapshot s of current stream (if MultiSite), selfview, far end and DuoVideo streams are accessible via http. See Appendix 6 for descriptions of the pos[...]

  • Страница 56

    TANDBERG Maestro MXP 56 Streaming Source*  Auto: Enables streaming o f both local a nd far end video. Selection of which site to be streame d is done using voice switching (the site that spe aks is st reamed).  Local: Only the local video will be streamed.  Remote: Onl y the far end video will be streamed. Local and far end audio is alway [...]

  • Страница 57

    General Use 57 3.6 Answer an incoming call How to answer an incoming call:  To accept an incoming call, press the OK button or the green Call button on the remote control. How to reject an incoming call:  To reject an incoming call, select the Rej ect icon and press the OK button, or press the End Call button on the remote control. Incoming c[...]

  • Страница 58

    TANDBERG Maestro MXP 58 3.7 End Call How to end a call:  Press the red End Call button on the remote control, or  Press the Menu button on the remote co ntrol to displ ay the menu and select End Call. When the End Call dialog box is displayed either:  Press the red End Call button on the remote control again, or  Press the OK button to [...]

  • Страница 59

    General Use 59 3.8 Standby The system will automatically go to Standby mode when it is not in use. In standby mode, the screen(s) are black. It is however st ill possible to receive incoming calls. How to enter standby mode manually :  Select Standby from the menu and select Standby Now, or  Press the End Call button on the remote control twi[...]

  • Страница 60

    TANDBERG Maestro MXP 60 3.8.1 Delay Standby for 1 hour Delay Standby for 1 hour postpones the system fro m enterin g standby mode for 1 hour. This function is useful when using the monitors for a local presentat ion to preven t the system from automatically blanking the monitors. It is also possible to postpone the system from entering standby mode[...]

  • Страница 61

    General Use 61 3.8.2 Delay Standby for 3 hours Delay Standby for 3 hours postpones the automatic standby mode for 3 hours. This function is useful when using the monitors for a local presentat ion to preven t the system from automatically blanking the monitors. It is also possible to postpone the system from entering standby mode for 1 ho u r, see [...]

  • Страница 62

    TANDBERG Maestro MXP 62 3.8.3 Do Not Disturb To prevent the system from accepting any incomi ng calls, activete the Do Not Disturb function. The caller will hear a bu sy tone when calling t he system. The monitor will be black when Do Not Disturb is active, see figure below. This is useful when using the display for a pre sentation as a local PC mo[...]

  • Страница 63

    General Use 63 3.9 Phone Book The Phone Book is available via the Phone Book bu tton on the remote cont rol or from the Make a Call menu. Using the Phone Book is time saving and prevent s the user from inadvertently calling the wrong number. The contacts are sorte d alphabetically . The contact names are displayed in the list and the telephone or v[...]

  • Страница 64

    TANDBERG Maestro MXP 64 3.9.1 Call Log The Call Log lists Placed Calls, Missed Call s and Re ceived Calls. That allows the user to see which calls that are made in the past. The lists contain a maximum of 30 numbers and the numbers are stored in these lists until the system is restarted. If the contacts listed are availa ble in the phone book, the [...]

  • Страница 65

    General Use 65 3.9.2 My Contacts My Contacts are the locally stored contacts on t he system. This means that it is possible to add new contacts and edit or del ete existing contact s. My Contacts can store up to 200 contacts. How to make a call using My Contacts: 1. Find the desired contact using the arro w keys o r searching on the first letter wi[...]

  • Страница 66

    TANDBERG Maestro MXP 66 The following functions are av ailable from My Contacts:  Call Now  New Contact  New MultiSite Contact  Edit Contact  Delete Contact  Close[...]

  • Страница 67

    General Use 67 3.9.2.1 Add New Contact The New Contact function is availabl e from My Conta cts . Add a new contact to My Contacts by: 1. Select the New Contacts button to open the New Contacts dialog b ox. 2. Enter Name by using the letter keys on the remote control. Input will automatically be interpreted as letters. Toggle betwe en ca pital lett[...]

  • Страница 68

    TANDBERG Maestro MXP 68 3.9.2.2 New MultiSite Contact (Optional feature*) The New MultiSite Contact function is av ailable from My Contacts . It is possible to pre-define the participa nts of a conference me eting as a MultiSite Contact. All participants in the MultiSite Contact will then be co nnected automatically instead of having to call the pa[...]

  • Страница 69

    General Use 69 Bandwidth for a MultiSite Contact call When calling a MultiSite Contact, the system will tr y to call the participants with their specified bandwidths. If the total bandwidth exceeds the sy stem's maximum bandwidth, the system wil l downspeed and distribute the av ailable bandwidth equally among all the partici pants. Example: I[...]

  • Страница 70

    TANDBERG Maestro MXP 70 3.9.2.3 Edit Contact The Edit Contact function is available from My Contacts . How to edit a contact in the Local Phone Book: 1. Select the contact that is to be edited. 2. Press the left arrow on the remote contro l, followed by the down arrow until the Edit Contact ic on is selected . 3. The current settings for this conta[...]

  • Страница 71

    General Use 71 3.9.2.4 Delete Contact The Delete Contact function is available from My Contacts . How to delete a contact: 1. Select the contact that is to be deleted. 2. Press the left arrow on the remote control, followed by the down arrow u ntil the Delete Contact icon is selected. The Delete Co ntact dialo gue box is displayed. 3. Confirm by pr[...]

  • Страница 72

    TANDBERG Maestro MXP 72 3.9.3 Global Contacts When selecting Phone Bo ok the ph one book ope ns showing the Gl obal Contacts* or the Corporate Directory** below the folders Plac ed Calls, Missed Calls, Received Calls and My Contacts. These contacts cannot be change d loca lly by the system, only from the management system. If there is a need to mod[...]

  • Страница 73

    General Use 73 3.9.3.1 Up one Level Global Contacts can be arranged in a tre e stru ct ure with several sub folders. Use the Up one Level button to navigate up in the tree structure. When a search in the Global Phone Book is m ade, by using the Search fun ction, only contacts matching the search text are displayed. Select the Up one Level button to[...]

  • Страница 74

    TANDBERG Maestro MXP 74 3.9.3.2 Search The phone book can cont ain an unlimited amount of global contac ts. Usin g search makes it easier to find the wanted contact. How to search in the Global Phone Book: 1. Select the Search icon. 2. Enter search text in the dialogue box that appears and press the OK button on the remote control. The system will [...]

  • Страница 75

    General Use 75 3.9.3.3 Copy Contact to My Contacts The Copy Contact to My Contacts function is available from the Placed Call s, Missed Calls, Received Calls and Gl obal Contacts folders, see Phone Book for details. It may be wise to copy contacts t hat are often used to My Contacts. Note that the local copy will not be updated if the Global Contac[...]

  • Страница 76

    TANDBERG Maestro MXP 76 3.10 Camera Control There are several ways to control the camera:  Control the camera directly with the arrow keys when the menu is closed or us e the Move Camera function in the menu to cont rol both the near end and far end camera, see Move Camera and Far End Cont rol for details.  Use the zoom button on the remote c[...]

  • Страница 77

    General Use 77 3.10.1 Move Camera It is possible to move the camera with the remote cont rol or via the menu. Moving the camera directly with the remote control When the menu is hidden, the arrow key s will work on the camera. If the menu is displayed, press the Cancel button on the remote control to hide it. Use the left and right arrow keys to pa[...]

  • Страница 78

    TANDBERG Maestro MXP 78 3.10.2 Far End Control Far End Control allows you to control yo ur conference partner’s ca mera. An exa mple of when this feature could be especially helpful is if it is not possible to see wh at a partici pant at the far end is writing on their white board. Use Fa r End Control to move the far end camera and zoom clos er [...]

  • Страница 79

    General Use 79 3.10.3 Camera Presets Use camera presets to easily vary between predef ined near end ca mera a ngles. This is useful when pictures from many different camera an gles have to be sent to the far end. E.g. in a meeting there is a white board, a PC and a sma ll meeting table. Use camera preset s to move between these camera p erspe ctive[...]

  • Страница 80

    TANDBERG Maestro MXP 80 3.10.4 TANDBERG Tracker How to save presets for the TANDBE RG Tra cker: 1. Select which camera prese t is to be use d on the TANDBERG Tracker. 2. Move the camera to the desired position to store on the tracke r. 3. Select Move Camera - Save New Preset in the menu. 4. All camera presets are access ible from the TANDBERG Track[...]

  • Страница 81

    General Use 81 3.10.5 Picture Control Focus, Brightness and Whi te balance are set for auto focus, auto br ightne ss a nd auto white balance by default. If you need to set focus, bri ghtness and white balance ma nually, go to Picture Control in the Camera Control menu. Focus Auto Auto focus continuously updates the fo cus thro ughout the call. When[...]

  • Страница 82

    TANDBERG Maestro MXP 82 3.10.6 Camera Tracking Through Camera T ra cking and the use of two or three microph ones, the camera can automatically position itself on t he current speaker. Before usi ng camera tracking, the camera positions used must be stored at Pre set 7 (Mic1) , Preset 8 (Mic2) and/or Pre set 9 (Mic3). How to use Camera Tracking: 1.[...]

  • Страница 83

    General Use 83 3.11 Presentation The Presentation Functionality in the system enabl es you to show other available video sources in addition to your Main Camera. This is perfe ct for meetings where you would like to show a PowerPoint presentation, for example. You can even use arro w keys up and down on the remote control to activate Page Up/Down o[...]

  • Страница 84

    TANDBERG Maestro MXP 84 3.11.1 Presentation Key The quickest way to show a pre sentatio n is to use th e presentation key on the remote control. The presentation key is used to start and stop a presentation. The presentation key will display PC (default*). When holding the pre sentat ion key for 1 second, the presentation menu will be displayed. Th[...]

  • Страница 85

    General Use 85 3.11.2 Presentation Menu The Presentation menu offers you all available video sou rces; Main Camera, PC, Document Camera, VCR, AUX and VNC. All these sources can be used a s Main Video S tream or Dual Video Stream (Duo Video / H.239). Not all sy stem s ha s all video sources available, see Interfaces for details. Outside a call the p[...]

  • Страница 86

    TANDBERG Maestro MXP 86 3.11.3 PC Presenter (DVI/VGA Input) (Optional feature - not available on all system s) Users often have their present ations on a laptop that is brought into the meeting room. Remember to connect your PC to the codec befo re you press the Presentation button. Note that the image will appear smoother on the system if y our pr[...]

  • Страница 87

    General Use 87 3.11.4 PC Soft Presenter and VNC (Optional feature) PC SoftPresenter is used to display PC image s on yo ur system without using a VGA cable (PC Presenter). The system and your PC must be connect ed to the same LAN. In addition, VNC (Virtual Network Computing) server software mu st be installed on the PC. Free softwa re can be downlo[...]

  • Страница 88

    TANDBERG Maestro MXP 88 3.11.5 Dual Stream (DuoVideo TF /H.239) (Optional feature - not available on all system s) With Dual Stream you have the opportunity to show two different live video stre ams simultaneously, main video and one a ddi tional source. This is hand y when showing a presentation. You see the live presentation and the live video of[...]

  • Страница 89

    General Use 89 3.11.6 Take New Snapshot The system can take a snapshot of your live vi deo. Snapshot is han dy when you are in a call with a system that does not support Dual Stream. Use Snapshot to show a snap shot of your presentation and continue the meeting with main camera. How to use snapshot: You find Take New Snapshot in the Presentation me[...]

  • Страница 90

    TANDBERG Maestro MXP 90 3.11.7 Display Snapshot The system stores the last sent or re ceived S napshot. The snapsho t is deleted a utomatically after the call. How to display snapshots: 1. To view a stored snapshot, first choose the Snapshot header. 2. Select Display Snapshot in the Presenta tion menu. 3. Press the Display Snapshot button again to [...]

  • Страница 91

    General Use 91 3.12 Conference Services A Multipoint Control Unit (MCU) enables severa l sites to participate in the same conferen ce. During an MCU confe ren ce, the status line will provide information about the conference. You can make a multipoint conference i n di fferent ways. The Co nferen ce Services vary depending on how you make the call,[...]

  • Страница 92

    TANDBERG Maestro MXP 92 Example of MultiSite for mid- to low end systems. Note that t he illustrations may differ from the actual product. Using the system’s internal MCU, MultiSite TF * Most TANDBERG MXP systems have an optional b u ilt-in MCU, wh ich is called MultiSite*. It supports up to 6 video calls and 5 tele p hone calls including yoursel[...]

  • Страница 93

    General Use 93 Using an external MCU with limited Chair Control Support y ou may hav e the following services With an external MCU that does not support H.243, you have the following servi ces:  Request/R elease F loor  Terminal Names * The MultiSite option is not available on the TA NDBERG 550 MX P, TANDBERG 770 MXP and TANDBERG 1000 MXP[...]

  • Страница 94

    TANDBERG Maestro MXP 94 3.12.1 Request Floor and Release Floor When requesting floor, your video will be broad casted in full screen to all other participants in the conference. Request Floo r is u seful when you want to speak or display somethi ng in front of all participants. Release Floor when you are done and m ake the fl oor available for othe[...]

  • Страница 95

    General Use 95 3.12.2 Conference Layout (Only supported by TANDBERG MultiSite*) With a TANDBERG MultiSite you can choose between the layouts: Auto Split, 4 Split, 5+1 Split and Voice Switched view. Auto Split displays all pa rticipants on the screen simultaneously. 4 Split displays the 4 last spe aking Part icipa nts incl uding the MultiSite host .[...]

  • Страница 96

    TANDBERG Maestro MXP 96 3.12.3 Terminal Names Choose Terminal Names to see a list of the parti ci pants of the MultiSite c onference. Press Cancel to go back.[...]

  • Страница 97

    General Use 97 3.12.4 Chair Control (Not supported by TANDBERG MCU o r MultiSite) As chairman, you have access to more MultiSite Services. Select Chair Co ntrol to assume the role of chairman of the conferen ce. Sele ct Release Chair to end the role as chairman. A Chair indicator appears when you have Ch air and disappea rs when chair is released.[...]

  • Страница 98

    TANDBERG Maestro MXP 98 3.12.5 Assign Floor and Release Floor from Participant Assign Floor allows the chairman to sel ect whi ch of the conference participants are to be broadcasted to all other participants.[...]

  • Страница 99

    General Use 99 3.12.6 View Site and End View (Not supported by TANDBERG MCU o r MultiSite) View Site allows you to view any participant in the conference regardless of wh o has the floo r and chair. Choose End View to go back to norm al.[...]

  • Страница 100

    TANDBERG Maestro MXP 100 3.12.7 Disconnect Participant Disconnect Participant allows the chai rman to di sconnect any participant in the conference. In a multipoint call, this is equivalent to disc onnecting a participant from the end call menu.[...]

  • Страница 101

    General Use 101 3.12.8 Terminate Meeting Terminate Meeting allows the chai rman to terminat e the conference altogethe r. In a MultiSite call, this is equivalent to pressing End All Call s from the end call menu.[...]

  • Страница 102

    TANDBERG Maestro MXP 102 3.12.9 More about MultiSite (embedded MCU) (Optional Feature*) Calling in to a MultiSite Any system can be part of a MultiS ite conference by calling in to a MultiSite. The dial-in numbers to the MultiSite depends of t he network that is used. To dial in to the MultiSite on IP:  Dial the IP Number or the IP Address of t [...]

  • Страница 103

    General Use 103 By connecting MultiSite systems together, it is possib le to connect even more sites in a cascaded MultiSite (see example below). All connection s can u se any combination of ISDN/IP. The host can connect up to 5 other video system s with Mult iSite functionality. T he cascaded systems can connect to 4 other video sites. These sy st[...]

  • Страница 104

    TANDBERG Maestro MXP 104 3.13 Control Panel The Control Panel contains the features:  Diagnostics  Text Chat  Audio Demonstration  Administrator Settings  Restart  User Guide[...]

  • Страница 105

    General Use 105 3.13.1 Diagnostics Diagnostics allows testing of individual syste m components a nd displays the current system settings. Diagnostics contain:  System Information  Channel Status  Call Status  System Selftest  View Administrator Settings  IP Address Conflict Check  Warnings[...]

  • Страница 106

    TANDBERG Maestro MXP 106 3.13.2 System Information Select System Information to view system numbers , line status, soft ware ve rsion, hardware serial number and other useful information. Press arro w key up and down to scroll in the System Information list. System Information con t ains: System Name My ISDN Number My IP Number My IP Address MultiS[...]

  • Страница 107

    General Use 107 3.13.3 Channel Status Comprehensi ve informatio n about the call progre ss is available through the Channel Status window. This window indicates the vario us stages each B-channel goe s through whilst establishing a connectio n. Status - BRI Comments Idle Calling Connected Sync Active Releasing Released the channel is idle when call[...]

  • Страница 108

    TANDBERG Maestro MXP 108 PRI Yellow Alarm Yellow alarm or Remote Alarm Indicator (RAI) mean s that the system is receiving framing info, but in this framing info the other side tells t he system that it is not reading the sy stem’s transmitted framing info. Typically, this may be a br oken connector in the TX part of the syste m PRI cable. This c[...]

  • Страница 109

    General Use 109 3.13.4 Call Status Comprehensive informatio n about the call is availabl e through the Call Status window. The menu has two columns, one for transmitted an d one fo r received audio/vi deo/data information. If Dual Stream or MultiSite is available on your syst em and in use, pressi ng the UP/DOWN key s will show one page per conne c[...]

  • Страница 110

    TANDBERG Maestro MXP 110 3.13.5 System Selftest The system performs a che ck to determine internal hardware integrity. System Selftest is useful when you want to check if your network connection is active.[...]

  • Страница 111

    General Use 111 3.13.6 View Administrator Settings This window displ ays all th e system settings. Us e the arrow key on the remote control to scroll through the list. View Administrator Settings may contain*: General Settings System Name Language Dual Monitor Auto answer Max Call Length Access Co de Incoming MCU calls Incoming Telephone calls Far [...]

  • Страница 112

    TANDBERG Maestro MXP 112 PC Document Camera VCR AUX VNC Split Screen Default Call Settings Call Type Network Bandwidth Restrict (5 6 k) Auto H320 Bandwidth Auto H323 Bandwidth SIP Audio Settings Inputs Mic1 Mic2 Mic3 Audio4 Audio5 Audio6 Mix Mode VCR Ducking Level Settings Mic1 Mic2 Mic3 Audio4 Audio5 Audio6 Outputs Out1 Out2 (AUX) Out3 (VCR) Out1 [...]

  • Страница 113

    General Use 113 White balance Brightness Video Name Main Cam AUX Doc Cam VCR PC VGA VNC Network Ty pe ISDN-BRIPRILeased E1T1Enternal H331 ISDN Switch Type ETSI (Euro ISDN),… Line1 Setup On Number1 Number2 SPID1 SPID2 Line2 Setup On Number1 Number2 SPID1 SPID2 Line3 Setup On Number1 Number2 SPID1 SPID2 Advanced ISDN Settings Sub Address Valida[...]

  • Страница 114

    TANDBERG Maestro MXP 114 IP address IP subnet mask Gateway Ethernet Speed H.323 Settings E.164 Alias Use Gatekeeper Gatekeeper IP H.323 Prefix Advanced H.323 Settings RSVP NAT NAT Address QoS IP Precedence Audio Video Data Signaling IP Type of Service (TOS) Diffserv Audio Video Data Signaling SNMP Settings SNMP Trap Host1 SNMP Trap Host2 SNMP Trap [...]

  • Страница 115

    General Use 115 3.13.7 IP Address Conflict Check The system will give a warning if there is an IP conflict. The user may initiate this check by selecting IP Address Conflict Che c k.[...]

  • Страница 116

    TANDBERG Maestro MXP 116 3.13.8 Warnings Any warnings registered by the system will be displayed in the Warnings me nu. Open a warning in the list to get more information about the warning. The following warnings ma y be displaye d if detected by the system, depending on system type and configuration: ISDN BRI warnings  ISDN is enabled on BRI li[...]

  • Страница 117

    General Use 117  There is something wrong with the Leased E1/T1 line (Yellow al arm). Please check your network connection. (1 93) H323 gatekeeper warnings  Could not register to the gatekeeper.  The gatekeeper rejected to regi ster the syste m. Another system is already regi st ered with the same alias or H.323 ID.  The max capacity on[...]

  • Страница 118

    TANDBERG Maestro MXP 118 3.13.9 Text Chat While in an ISDN or IP call to another system suppo rting Text Chat (T.140), select Text Chat from the Control Panel. Enter text in the displayed window. How to use Text Chat: 1. Choose Text Chat from the Control Panel to open the Text Chat window. 2. Enter text with the number keys like on a mobile phone. [...]

  • Страница 119

    General Use 119 3.13.10 Audio Demo Note that the Audio demo will only appear in the User Guide if a Di gital Natural Audio Mod ule is connected to the codec.[...]

  • Страница 120

    TANDBERG Maestro MXP 120 3.13.11 Administrator Settings Administrator Settings contains the configurat ion of the whol e system. It is recommended to password protect Administrator Settings to prevent occa sion al users from making changes to the system. See Administrator Settings for further details.[...]

  • Страница 121

    General Use 121 3.13.12 Restart Restart the system by pressing the Restart butt on. You are prom p ted with a dialog box saying: Do you want to restart the system? Press OK to restart, press Cancel (X) to abort.[...]

  • Страница 122

    TANDBERG Maestro MXP 122 3.13.13 User Guide The on screen user guide take s you through a quick step-by-step introduction to videoconferencing. It gives the user basic skills in how to use the sy stem.[...]

  • Страница 123

    4 Administrator Settings Administrator Settings contain all the settings of the system. Making changes to Administrator Settings will change the behavior of the system . It is recommended to password protect the access to Administrator Settings to prev ent occasi onal users from making cruci al changes to the system, see Administrator Password . Ad[...]

  • Страница 124

    TANDBERG Maestro MXP 124 4.1 General Settings When installing the system, go through the Gene ral Settings menu to ensure that you have the right settings for your syste m , see Syste m Configuration. General Settings contain:  Language  System Name / International Name *  Auto Answer  Phone Book Settings  External Service Settings ?[...]

  • Страница 125

    Administrator Settings 125 4.1.1 Language The system supports 16 dif f erent lang uages for its on-screen menus; English, G erma n, French, Norwegian, Swedish, Italian, Spanish, P ortuguese, Russian, Finnish, Chinese Simplified, Chinese Traditional, Japanese, Korean, Thai and Arabic. Select the preferred lang uage and press OK to save. Note that pr[...]

  • Страница 126

    TANDBERG Maestro MXP 126 4.1.2 System Name System Name identifies the sy stem:  On the welcome page.  During an MCU confe ren ce call.  When using the Web-inte rf ace.  When the codec is acting as an SNMP Agent.  Towards a DHCP serv e r.  H323 ID. Other systems can call in u sin g this name instead of IP-number/IP-address. System [...]

  • Страница 127

    Administrator Settings 127 4.1.3 International Name If the System Name contains Asian and non-Latin cha racte r text input, the International Name using Latin characters only , must be sp ecified as well. This is in order to make other s ystems understand the system na me.[...]

  • Страница 128

    TANDBERG Maestro MXP 128 4.1.4 Auto Answer The auto answer setting decides whether an incomin g call is p ut through automatically or manually. On The system will automatically answer al l incoming cal ls. On+Mic Off The system will automatically answer all incomin g cal ls and switch the microphone off when the call is connect ed. Press Mic Off to[...]

  • Страница 129

    Administrator Settings 129 4.1.5 Phone Book Settings Corporate Directory On The Corporate Dire cto ry is available in the menu. Off The Corporate Dire cto ry is hidden from the menu and is unavailable for users. IP address Enter the IP address of the management system that provides the Phone Boo k. Path The Path indicates the function of the manag [...]

  • Страница 130

    TANDBERG Maestro MXP 130 4.1.6 External Services Settings External Services On When set to On External Services are available. Off When set to Off External Services are unavailable. IP address Enter the IP address of the service provider for Extern al Service s. Path Enter the Path to the External Services provider. The services available are def i[...]

  • Страница 131

    Administrator Settings 131 4.1.7 Permissions Permissions contains settings for in coming MC U Calls, inco ming telephone Calls, Far End Control, Remote Software Upgrade and Fallba ck to Telephony. Access Code An access code will help you control the use of the system. All users must enter a code to identify themselves and the call will be cha rged [...]

  • Страница 132

    TANDBERG Maestro MXP 132 Far End Camera Control On The far end will be able to: • Control your camera • Select your video sources • Activate your camera presets • Request snapshots Off The far end can access none of the four features abo ve on the local system. You will however still be able to control the camera on the fa r end. Fallback t[...]

  • Страница 133

    Administrator Settings 133 4.1.8 Screen Settings Auto Layout On If Auto Layout is On the system will change layouts automatically depen ding on t he number of participants in a call and if you have a dual video strea m or not. Please refer to Layout for more information. Off If Auto Layout is Off there will be no auto matic layout changes during a [...]

  • Страница 134

    TANDBERG Maestro MXP 134 Picture Layout The Advanced Picture Layout is related to t he Layout button on the remote control and it can be used at any time to change the screen la yout. For wide screen syst ems POP mo de is recommended. You will get optimiz ed picture layouts for wide sc reen by pressi ng the Layout button on the remote. Picture in P[...]

  • Страница 135

    Administrator Settings 135 Example of 1+2 Picture outside Picture (wide screen). Example of 1+3 Picture outside Picture (wide screen). Note that if both TV monitor format and VGA format is set to Normal, the system will skip the 1+3 layout, which is not beneficial for 4:3 monitors.[...]

  • Страница 136

    TANDBERG Maestro MXP 136 VGA Monitor Format To fully leverage your wide screen display, activate the Native 16:9 format by setting the VGA Monitor Format to Wide. Note that you should only change this sett ing if your VGA monitor is a wide screen (16:9) monitor or projecto r. T he VGA and DVI output will then be optimized fo r Wide Screen VGA and H[...]

  • Страница 137

    Administrator Settings 137 Auto VGA output format will be optimized dependant of the video source format, refresh and of the EDID information avai lable. Supported formats are: SVGA (800x600) 75Hz XGA (1024x768) 60Hz / 75Hz WXGA (1280x768) 60Hz SVGA 800x600 75Hz VGA output format is forced to SVGA format (800x600) 75Hz XGA 1024x768 60Hz VGA output [...]

  • Страница 138

    TANDBERG Maestro MXP 138 PC Presentation shown in Wide (stretched) mode.[...]

  • Страница 139

    Administrator Settings 139 4.1.9 Software Options The system requires a valid option key to activa te MultiSite and/or Presenter functionality. In order to activate additional band width, you need to enter a bandwidth key. A restart of the system is required after entering a new option a nd/or bandwi dth keys. If the key is invalid, the original ke[...]

  • Страница 140

    TANDBERG Maestro MXP 140 4.1.10 Date and Time Settings NTP IP This is the NTP time server address from whi c h the system can get updated time information. See IP Services for more details. Auto The NTP IP address is set automatically. Manual The NTP IP address is set manually. IP Address The IP Address for obtaining the date and time information. [...]

  • Страница 141

    Administrator Settings 141 4.2 Menu Settings Menu Settings contain the settings:  Input Editor Language  Menu Timeout In Call  Menu on TV  Menu on PC  Balloon Help  Administrator Password  Kiosk Mode Settings  Startup  Icons[...]

  • Страница 142

    TANDBERG Maestro MXP 142 4.2.1 Input Editor Language When the Input Editor Language is set to Chinese, Korean or Jap anese the user will be able to enter Chinese / Korean / Japanese characters into an input field like the System Name or Phone Book, using the remote control.[...]

  • Страница 143

    Administrator Settings 143 4.2.2 Menu Timeout in Call The Main menu appears on the bottom line of the sc reen. Set Menu Timeout In Call to On if you want the menu to time out automatically when you are in a call. On The menus will time out automatically after 15 seconds if there is no activity on the remote control. Menu timeout does only apply whe[...]

  • Страница 144

    TANDBERG Maestro MXP 144 4.2.3 Menu on TV The Menu on TV setting decides if the menu shall be displayed o n the TV screen or not. For optimal layout of the menu, Menu on TV should be Off if Menu on PC is On a nd vice versa. On The menu is available on the TV screen . Off The menu is not available on the TV screen. Note that if the menu has disappea[...]

  • Страница 145

    Administrator Settings 145 4.2.4 Menu on PC The Menu on PC setting decides if the menu shall be displayed o n the PC (VGA screen) screen or not. For optimal layout of the menu, Menu on TV should be Off if Menu on P C is On and vice versa. On The menu is available on the PC screen. Off The menu is not available on the PC screen. Note that if the men[...]

  • Страница 146

    TANDBERG Maestro MXP 146 4.2.5 Balloon Help It is possible to enable / disable the ballo on help window. On Choose On if you want help text windows to appear. Off There will be no help text window.[...]

  • Страница 147

    Administrator Settings 147 4.2.6 Administrator Password It is recommended to put an Administrator Passw ord on the system. The Administrator Password can be maximum 5 digits long. The Administrator Password di alog box will pop up when you choose Administrator Settings from the Control Panel. This will prev ent occasi onal users from going in to ad[...]

  • Страница 148

    TANDBERG Maestro MXP 148 4.2.7 Kiosk Mode Settings Kiosk Mode In Kiosk Mod e t he system is set to a sim plified st ate where it can be contro lled wit h just the four arrow keys and OK. You will get a simplified on-screen menu with only basi c functionality available:  make calls (using p red efin ed contacts in the phone b ook)  receive cal[...]

  • Страница 149

    Administrator Settings 149 If Language Menu is enabled you will first see the lan guag e selection menu. Select languag e and the Welcome Menu will be displayed wit h your desired language. In a call, the system will display Far End video in full screen. If Max Call Length is set to a value and the system is in a call, the system will di splay a wa[...]

  • Страница 150

    TANDBERG Maestro MXP 150 Kiosk Mode - Auto Dial* On The system will automatic ally dial to t he first contact in the Phone Book when he handset is lifted. If this contact is busy, t he system will call the seco nd number in the Phone Book and so on. If the user places t he handset in the cradl e, the system will switch to Speaker Mode. Only the Far[...]

  • Страница 151

    Administrator Settings 151 4.2.8 Startup Welcome Menu The Welcome Menu contains the Main Menu, Syst e m Status, your System Name and dial in numbers. On The Welcome Menu is sh own when the system wakes up from st andby mod e. Off The Welcome Menu is not shown when the system wakes up from standby mode. Press the OK button to open the welcome menu. [...]

  • Страница 152

    TANDBERG Maestro MXP 152 On Welcome text is displayed on the wel come menu. Off Welcome text is not displayed on the wel come m enu. Welcome Text You can change the welcom e text to any text you like, instead of the default text. Remember t hat Display Welcome Text must be On to be able to edit the welcome text.[...]

  • Страница 153

    Administrator Settings 153 4.2.9 Icons The following indicator ico ns may be set to on or off:  Mic Off  Volume Off  On Air  Encryption  Bad Network  Telephone See On-screen Indicators for details.[...]

  • Страница 154

    TANDBERG Maestro MXP 154 4.3 Presentation Settings Presentation Settings contain:  Presentation Start  H.239  Startup Video Source  Presentation Source  Snapshot Source  Auto-Display Snapshot  PIP Appearance  PIP Placing  VNC Settings[...]

  • Страница 155

    Administrator Settings 155 4.3.1 Presentation Start If your system has Dual Stream capa bil ities, y ou can show two video streams at the same time (see also Dual Stream ). Presentation St art is Auto by default. This means that you will start Dual Stream (a second video st ream ) automatically when starting a p re sentatio n. Du al Stream requires[...]

  • Страница 156

    TANDBERG Maestro MXP 156 4.3.2 H.239 H.239 supports transmission of two video st ream s. It combi nes elements of Duo Video and People+Content. If H.239 is disabled you will still be able to start TANDBERG Dual Video Stream* Enabled Enables H.239 Disabled Disables H.239 * The TANDBERG 550 MXP can only receive Dual Video Stream.[...]

  • Страница 157

    Administrator Settings 157 4.3.3 Startup Video Source The Startup Video Source is the video source on display w hen the system wakes up from standby mode. If you use Main Camera as star t up source, the system will start with Main Camera every time the system wakes up from stan db y, regardl ess of what the previous user was using. You can change S[...]

  • Страница 158

    TANDBERG Maestro MXP 158 4.3.4 Presentation Source The Presentation Source is connected to the Pr esentation button on the remote. Pressin g the Presentation button will put the Pr esentation Source on display. Presentation Source is PC by default*. You can change the Pre sentati on Source to any video source and none. Choosin g none results in ope[...]

  • Страница 159

    Administrator Settings 159 4.3.5 Snapshot Source When you take a Snapshot, you get a snapshot of the Snapshot Source. Current is the default Snapshot Source. This means that you take a sn apshot of the video source that is cu rrently active. You can change the Snapshot Source to any vi deo source. In this way you ca n prog ram the snapshot key to a[...]

  • Страница 160

    TANDBERG Maestro MXP 160 4.3.6 Auto-Display Snapshot Select Auto to automatically display a received snapshot. Turn Auto-Di spl ay Snapshot Manu al if you wish not to have them displayed on the sc reen when they are sent or received. The snapshots will be sent and received, but not di splayed. With Auto-Display Snapshot set for Manual, you must ent[...]

  • Страница 161

    Administrator Settings 161 4.3.7 PIP Appearance A Picture in Picture (PIP) is a smaller picture placed in one of the corne rs of the screen. The PIP enables you to see an extra picture in your video con ference. Auto PIP Auto means that Picture In Picture will appear automatically when it is suitable. A picture in picture is nice when you use Duo V[...]

  • Страница 162

    TANDBERG Maestro MXP 162 4.3.8 PIP Placing PIP Placing lets you decide where the PIP shall appear. You can of course m ove the PIP with the Layout button on the remote anytime. Top Right PIP is placed in the Top Right corner. Bottom Right PIP is placed in the Bottom Right corner. Bottom Left PIP is placed in the Bottom Left corner. Top Left PIP is [...]

  • Страница 163

    Administrator Settings 163 4.3.9 VNC Settings VNC Settings is necessary when usi ng a VNC present ati on. See chapter PC Soft Presenter and VNC for more information on how to use VNC. Address The IP-address of the PC with the V NC software installed. To find the IP- address of the PC, place the mouse poi nter on the V NC p rogram icon in the lower [...]

  • Страница 164

    TANDBERG Maestro MXP 164 4.4 Call Quality Call Quality contains the settings:  Video Algorithm  Audio Algorithm  AAC-LD 128kbps  Natural Video  Max Upstream Rate  Video Quality  Default Call Settings[...]

  • Страница 165

    Administrator Settings 165 4.4.1 Video Algorithm The system will automatically select the best video algorithm b ase d on the video source and the capabilities of the remote system. Use this menu to disabl e video al gorithms in case you have interoperability issues calling other systems. H.264 Bandwidth efficient video compression and decomp re ss[...]

  • Страница 166

    TANDBERG Maestro MXP 166 4.4.2 Audio Algorithm The system will automatically select the bes t audio al gorithm based on the call rate and the capabilities of the remote system. Use this menu to disable audio algorithms in case you want to remove “low quality” audio , or if you have in teroperabi lity issues calling other systems. G.722 High qua[...]

  • Страница 167

    Administrator Settings 167 4.4.3 AAC-LD 128kbps (stereo audio) Specify a call rate for 128kbps AAC-LD. From this call rate and abo ve, "128kbps AAC-LD" is available. On lower call rat es "64 kbps AAC-LD" is av ailable. Stereo audio require s twi ce the bandwidth as mo no CD-quality audio. Therefore we re commend enabling stereo [...]

  • Страница 168

    TANDBERG Maestro MXP 168 4.4.4 Natural Video Choosing Natural Vide o will enable 60 fields* per se cond true interlaced pictu re for high m otion video. The use of Natural Video requires the H. 263+ and H.263++ video protocols. Natu ral video will be disabled in H.323 MultiSite calls and in H.320 Continu ou s Presen ce Mul tiSite calls. Auto Natura[...]

  • Страница 169

    Administrator Settings 169 4.4.5 Max Upstream Rate (kbps) The Max Upstream Rate (kbps) defines the desired maximum transmitted call rate. This is to be able to limit the outgoing bandwidth whilst keeping th e maximum incomi ng bandwidth, especially useful for home offices wit h different upst ream and downstream ra tes, typically ADSL.[...]

  • Страница 170

    TANDBERG Maestro MXP 170 4.4.6 Video Quality The different video sources need differe nt Video Qual ity Settings. Main Camera, VCR, AUX and Split Screen have Motion as default. PC, Docume nt Came ra and VNC have Sharpness a s default. Motion* Optimized for smooth motion video (CIF/SIF or w288p for low ba n dwidths, 448p/400p, Interlaced CIF (iCIF) [...]

  • Страница 171

    Administrator Settings 171 Sharpness*: Improved quality of detailed images and grap hics, lower frame rate, ideal for enhancing quality at lower bandwidths.  4CIF will be used from a PAL video input, Digital Clarity  4SIF from NTSC, Digital Clarity  w720p will be used from a wide format (HD720p) input  VGA/SVGA/XGA from PC, Digital Clar[...]

  • Страница 172

    TANDBERG Maestro MXP 172 Native PAL:  4CIF (704 x 576 pixels), Digital Clarity  448p (576 x 448)  iCIF (352 x 576 pixels), Natural Video  CIF (352 x 288 pixels)  QCIF (176 x 144 pixels)  SQCIF (128 x 96 pixels) Native PC Resolutions:  XGA (1024 x 768 pixels), Digital Clarity  SVGA (800 x 600 pixels), Digital Clarity  VGA [...]

  • Страница 173

    Administrator Settings 173 4.4.7 Default Call Settings Default Call Settings are connected with Call Settings in the call menu. If you leave Call Settings unchanged when making a call, the syst em will us e the Default Call Settings in the call. In addition to the Call Settings Call Type, Net, Bandwidth and Restrict (56k), you also find settings fo[...]

  • Страница 174

    TANDBERG Maestro MXP 174 Select ISDN to ensure that the call is set up as an ISDN call. Select H.323 to ensure that the call is set up as an H.3 23 call. Select SIP to ensure that the call is set up as an SIP call. Bandwidth Bandwidth decides the qu a lit y of the video picture. When set to Auto the system will establ ish a conn ection using a prop[...]

  • Страница 175

    Administrator Settings 175 These types of calls are often referred t o as  H.221 calls  2x64 calls  2x56 calls - as making 2 x 64 kbps or 2 x 56 kbps call s to the same system. Place this type of call by:  Set Network to ISDN  Set Bandwidth to 128 kbps  A field for the 2nd number pops up in Call Settings.  Enter the second numb[...]

  • Страница 176

    TANDBERG Maestro MXP 176 4.5 Audio Audio contains the settings:  Inputs  Outputs  Echo Control  Stereo Settings  Audio Leveling (AGC)  Alert Tones and Volume[...]

  • Страница 177

    Administrator Settings 177 4.5.1 Inputs Mic 1- 3 and Audio input 4-6 By default, all inputs are enabled. Just plug in an au dio sou rce and it is active. Audio inputs that are On will automatically be mix ed. Unconnected inputs will automatic ally be muted. Select Off to prevent audio/noise from connected b ut unused in puts. The activated audio so[...]

  • Страница 178

    TANDBERG Maestro MXP 178 It is possible to adjust the audio input levels ac cording to which external audio eq uipment is connected. The on-screen audio level indicator will m a ke it easier to set the correct input level settings. The input level should be adju sted so that the average level rea ches the transition between the green and the yellow[...]

  • Страница 179

    Administrator Settings 179 TANDBERG Audio Science m icroph one elements: Audio Technica AT-861P Z and Crown PZM- 6D Signal levels - microphone inputs Clipping level Nominal level Input menu level settings Vpp dBu dBu 0.0 dB 83.0 mVpp -28.4 dBu -46.4 dBu 1.5 dB 69.8 mVpp -29.9 dBu -47.9 dBu 3.0 dB 58.8 mVpp -31.4 dBu -49.4 dBu 4.5 dB 49.4 mVpp -32.9[...]

  • Страница 180

    TANDBERG Maestro MXP 180 Signal levels - line level inputs Clipping level Nominal level Input menu level settings Vpp dBu dBu 0.0 dB 15.5 Vpp 17.0 dBu -1.0 dBu 1.5 dB 13.0 Vpp 15.5 dBu -2.5 dBu 3.0 dB 11.0 Vpp 14.0 dBu -4.0 dBu 4.5 dB 9.2 Vpp 12.5 dBu -5.5 dBu 6.0 dB 7.8 Vpp 11.0 dBu -7.0 dBu 7.5 dB 6.5 Vpp 9.5 dBu -8.5 dBu 9.0 dB 5.5 Vpp 8.0 dBu -[...]

  • Страница 181

    Administrator Settings 181 4.5.2 Outputs Audio out 1 - 3 Audio out 1 is intended for connection to TANDBERG Digital Natural Audio Module, television s or audio amplifiers. Audio out 2 is intended for connection to audio re co rding equipment or to a teleph one add-on hybrid. The signal is a mix of audio from both the far end and lo cal end (not fro[...]

  • Страница 182

    TANDBERG Maestro MXP 182 Signal levels - line level outputs* Absolute max. output level Nominal level Output menu level settings Vpp dBu dBu 0.0 dB 1.2 Vpp -5.5 dBu -23.5 dBu 1.5 dB 1.4 Vpp -4.0 dBu -22.0 dBu 3.0 dB 1.6 Vpp -2.5 dBu -20.5 dBu 4.5 dB 1.9 Vpp -1.0 dBu -19.0 dBu 6.0 dB 2.3 Vpp 0.5 dBu -17.5 dBu 7.5 dB 2.8 Vpp 2.0 dBu -16.0 dBu 9.0 dB [...]

  • Страница 183

    Administrator Settings 183 4.5.3 Echo Control Mic 1-3 and Audio 4 Each of the 3 microphone inputs a nd Au dio input 4 has a separate acoustic echo can celler. One echo canceller per input provides mo re sophisticated control than having one co mmon canceller for all microphones. In addition to echo cancellation, the system has built-in noise reduct[...]

  • Страница 184

    TANDBERG Maestro MXP 184 4.5.4 Stereo Settings Settings Output response Out 1 Mode* Stereo I/O Mode Stereo Speakers Audio out 1 Audio out 2 Audio out 3 Analog Off Off Loudspeaker mono AUX VCR Analog Off On Loudspeaker left Loudspeaker right VCR Analog On Off Loudspeaker mono VCR-left VCR-right Analog On On Loudspeaker left Loudspeaker right VCR SPD[...]

  • Страница 185

    Administrator Settings 185 Note that if Stereo Speakers are enabled in the menu without having any stereo speakers connected to the Digital NAM, it may cause the acoust ic echo-ca nce ller to malfunction. If the system is connected to a Digital NAM , stereo sou nd on the loudspeake rs shall be present if a stereo input signal is conn ect ed to the [...]

  • Страница 186

    TANDBERG Maestro MXP 186 4.5.5 Audio Leveling (AGC) On Select On to allow automatic adjustments (Automatic Gain Control ) of audio leve ls. When On, the AGC maintains the audio sign al level at a fixed value by attenuating strong signals and am plifying we ak signals. Very weak signal s, i.e. noise alone, will not be amplified. Off Audio leveling i[...]

  • Страница 187

    Administrator Settings 187 4.5.6 Alert Tones and Volume Video Call Alert Tone and Telephone Alert Tone To help distinguish between incoming video calls a nd ordinary telephone calls, it is re commended to use different ringing tones for video calls and telep hone calls. Alert Volume You may change the volume level for the selected ri nging ton e. A[...]

  • Страница 188

    TANDBERG Maestro MXP 188 4.6 Video Video contains the settings:  Camera Tracking Mo de  MCU Status Line  Floor to Full Screen  Web Snapshots  MultiSite Picture Mode  Video Name[...]

  • Страница 189

    Administrator Settings 189 4.6.1 Camera Tracking Mode Slow The system waits a while before zoomi ng in on a si ngle person speaki ng. Suitable when wide-angle images are preferred over close-up images. Normal Should be used in regular meetings. Fast The system quickly zooms in on a sing le person speaking. Suitable when clo se- ups are preferred ov[...]

  • Страница 190

    TANDBERG Maestro MXP 190 4.6.2 MCU Status Line On The MultiSite / MCU / DuoVideo indicat ors will be di splayed and provide information about the conference. Off The MultiSite / MCU / Duo V ideo indi cators will not be displaye d. Auto The MultiSite / MCU / DuoVideo indicat ors will be displayed for a few seconds and then timed out. When grabbing t[...]

  • Страница 191

    Administrator Settings 191 4.6.3 Floor to Full Screen When "Floor to Full Screen" is enable d, some one wh o requests floor will be seen by all participants as full screen. Whe n "Floor t o Full Screen" is "Off", someone who request floor in a MultiSite conference using the 5+1 layo ut will be se en in the large square[...]

  • Страница 192

    TANDBERG Maestro MXP 192 4.6.4 Web Snapshots The system is able to generate JPE G snapshots and provide them when requested (as ‘http g et’ or via ftp). See Appendix 6 for descriptions of the possible snapshot files. On Snapshots generation is enabled. Off Snapshots generation is di sabl ed. Note that web snapshots are not gene ra ted if the co[...]

  • Страница 193

    Administrator Settings 193 4.6.5 MultiSite Picture Mode MultiSite* Picture Mode determines the default lay out of a MultiSite call. Available layouts are: Auto Split, 4 Split, 5+1 Split, and Voice Switched. You can change the layout during a call using the layout option in MultiSite Services. Auto Split Auto Split displays all participants on the s[...]

  • Страница 194

    TANDBERG Maestro MXP 194 Voice Switched mode[...]

  • Страница 195

    Administrator Settings 195 4.6.6 Video Name As a default, the video inputs are given the name s Main Cam, PC, Do c Cam, VCR, AUX or VNC, dependent on what video sources ar e available on yo ur system. The video names cannot exceed eight characters. The nam es corre spond to the video names in the Presentation Menu (Choose Presentation from the main[...]

  • Страница 196

    TANDBERG Maestro MXP 196 4.7 Security Security contains the settings:  Encryption  Encryption Mode  Passwords[...]

  • Страница 197

    Administrator Settings 197 4.7.1 Encryption (Country specific) Auto The system will try to set up calls using encryption. Point to point calls: If the far end system supports encryption (AES or DES), the call will be encrypted. If not, the call will proceed without encryption. MultiSite calls*: In order to have encrypt ed MultiSite calls, all sites[...]

  • Страница 198

    TANDBERG Maestro MXP 198 4.7.2 Encryption Mode Auto The system will try to use the most secure encryption - AES, dependent on the capabilities of the other si tes. For sites that do not support AES encryption, DES encryption will be tried. AES The system will try to use AES with 128 bits encryption when setting up calls. If AES is not supported by [...]

  • Страница 199

    Administrator Settings 199 4.7.3 Passwords Administrat or Password, I P Access Pa ssword , Streaming Password, VNC Password, Access Code and Remote Software Upgrad e password ar e duplicated from their respe ctive menu s. Using the Security menu g ives you a qui ck way to change all password s of the sy stem.[...]

  • Страница 200

    TANDBERG Maestro MXP 200 4.8 Network The network menu contain:  ISDN/External/Leased E1/T1  LAN Settings  Network Profiles  Data Port[...]

  • Страница 201

    Administrator Settings 201 4.8.1 ISDN/External/Leased E1/T1 Network Typ e Before using the system it is necessary to spe cify which network to use and define its settings. ISDN- BRI If you want to use your system via IS DN-BRI, you sho uld sel ect Network Ty pe: ISDN-BRI and enter the ISDN BRI Settings menu to set the BRI parameters. ISDN- PRI* If [...]

  • Страница 202

    TANDBERG Maestro MXP 202 4.8.1.1 ISDN-BRI Settings To make sure your system will work properly using ISDN-BRI, make the fo llo wing settings: 1. Set ISDN switch type 2. Enter ISDN line numbers (+ SPIDs if required) 3. Disable unused lines Some software versions do not support 6 ISDN li nes, t herefo re some of the Line Setup entries may be grayed o[...]

  • Страница 203

    Administrator Settings 203 Advanced ISDN Settings Sub address Using a sub address ena bles you to connect up to eight ISDN termi nals to the same ISDN telephone number and line. The terminal s are addressed by using d ifferent sub addresses. To call a terminal with a sub addre s s, sep arate the ISDN telephone number a nd the sub address with a ‘[...]

  • Страница 204

    TANDBERG Maestro MXP 204 4.8.1.2 ISDN-PRI Settings To make sure your system will work properly using ISDN-P RI, configure the following settings: 1. Set PRI switch type 2. Enter PRI line number Note that the T1 format is predefined to ESF and the line code is B8ZS. This is not configurable. Number Range Enter the range of numbers for your PRI line.[...]

  • Страница 205

    Administrator Settings 205 Example: Max Channels may be used for PRIs tha t are provisioned for a lower number of channels. High Channel, Low Ch ann el and Search may be used for PRIs provisioned wit h specific requirements for B-chann el usage. In the example above, the system will start searchin g for available B-channels at chan nel 20, since Se[...]

  • Страница 206

    TANDBERG Maestro MXP 206 Example: AT&T offers several digital switched services. These include SDN with service code 1 and ACCU NET with service code 6. Below is a list of common servic e profiles. As these profiles may change, contact your servi ce prov ider to get the corre ct profile. Service profiles for AT&T: NSF Service Disable: 0 SDN[...]

  • Страница 207

    Administrator Settings 207 4.8.1.3 Leased E1/T1 Settings Call Control Auto When Auto is selected, the system will automatically initiate a connection as soon as it detects that the far end trie s to make a call. This mo de is also commonly known as "data trigge red" mo de, becau se the existen ce of certain data patterns on the line trigg[...]

  • Страница 208

    TANDBERG Maestro MXP 208 4.8.1.4 External Network Settings Before using the system together with ex ternal network equipm ent, you must specify the network parameters on this page. The syste m ha s support for up to 2 Mbps (dependi ng on the Bandwidth key loaded) using the External Network (RS449/ V.35/X.21) interfa c e. Note that the physi cal int[...]

  • Страница 209

    Administrator Settings 209 Network clocking The network clock setting specifies the numbe r of physical external clock si gnal s. RS449/V35 Compatible Use RS449/V35 Compatible when t he external equi pment provides two clock signals, one for tran smit and one for receive. The difference between RS449 and V35 is only the cabl e. X21 Compatible Use X[...]

  • Страница 210

    TANDBERG Maestro MXP 210 4.8.1.5 H.331 Settings On Used when broadcasting a videoco nference from one site to many others, e.g. via satellite, where there is no possibility to negotiate quality between the receivers and the originator due to one-way communication. Off Standard two-way communication with quality negotiation betwee n both sid es.[...]

  • Страница 211

    Administrator Settings 211 4.8.2 LAN Settings LAN Settings contain:  IP Settings  H.323 Settings  SIP Settings  SNMP Settings  IP Services  Quality of Service  802.1X Settings[...]

  • Страница 212

    TANDBERG Maestro MXP 212 4.8.2.1 IP Settings Remember to restart the system after making cha nge s to IP Settings. This can be done by selecting the “Save and Restart” at the b ottom of the IP setting men u. Changes in IP Settings menu will not have any effect until the system is restarted. IP Protocol IPv4 IP version 4 suppo rted. IPv6 IP vers[...]

  • Страница 213

    Administrator Settings 213 Ethernet Speed Auto The codec will auto-dete ct t he speed/d uplex on the LAN. 10/Half The codec will conn ect to the LAN u sing 10Mbps speed/Half Duple x. 10/Full 10 Mbps speed/Full Duplex . 100/Half 100 Mbps speed/Half Dupl ex. 100/Full 100 Mbps speed/Full Duplex. IP Access Pass word By setting an IP Access Password on [...]

  • Страница 214

    TANDBERG Maestro MXP 214 DNS Settings DNS Server 1-5 DNS Server defines the network addre sses fo r DNS serve rs. Up to 5 addresses may be specified. If the network addresses are unkno wn, please contact your administrator or Internet Service Provider. DNS Domain Name DNS Domain Name is the default domain name suffix which is added to unqu alified [...]

  • Страница 215

    Administrator Settings 215 4.8.2.2 H.323 Settings E.164 alias This is the E.164 address of the system . The E.164 addre ss is equivalent to a telephone number, sometimes combined with access code s. Valid characters are 0-9, * and #. Whe n using a gatekeeper, the system will send a messag e to the gatekeeper containing both the E.164 addre ss and t[...]

  • Страница 216

    TANDBERG Maestro MXP 216 Gatekeeper Settings Gatekeeper Discovery Auto The sy stem will automatically try to register to any available gate k eepe r. If a gatekeeper responds to the request sen t from the codec within 30 second s this specific gatekeeper will be use d. This require s auto di scovery on the gatekeeper as well. If no gatekeeper re sp[...]

  • Страница 217

    Administrator Settings 217 CallManager Settings CallManager IP This is the CallManager IP-address that is used if you specify H.323 Call Setup: CallManager.[...]

  • Страница 218

    TANDBERG Maestro MXP 218 Advanced H.323 Settings The Advanced H.323 Settings only have an effect if t hey are supported by your IP infrastructure. NAT NAT, Network Address Translation, is used whe n a PC and a vide oconferencing system a re connected to a router with NAT suppo rt. NAT sup port in the videoconferencing system enabl e s proper exchan[...]

  • Страница 219

    Administrator Settings 219 4.8.2.3 SIP Settings Mode On Setting the SIP mode to on will enable the system for incoming and outgoin g SIP calls. Off Setting the SIP mode to off will disable incoming and outgoing SIP calls from the system. Display Name The Display name part of the SIP Addre ss (U RI) is usually a full name or system name. Examples: ?[...]

  • Страница 220

    TANDBERG Maestro MXP 220 The Server Address is the manually con f igured a ddress for the out boun d proxy and registrar. It is possible to use a fully qualified domain name, or an IP addres s. The default port is 5060 for TCP and UDP, but another one can be provided. Server Address: <text field> Examples: “sipserver.ex ample.c om” “sip[...]

  • Страница 221

    Administrator Settings 221  RFC 2429 RTP Payload Format for the 1998 Versi on of ITU-T Rec. H.263 Video (H.263+)  Draft-ietf-avt-rfc2429-bis-0 5.txt - Draft for advan ced vi deo signaling includi ng resolution, mpi, annexes and custom formats.  RFC 3047 RTP Payload Format for ITU-T Recomme ndation G.7 22.1  RFC3581 An Extension to the S[...]

  • Страница 222

    TANDBERG Maestro MXP 222 4.8.2.4 SNMP Settings SNMP Settings SNMP Trap Host identifies the IP-address of the SNMP manager. SNMP (Simple Network Management Protocol, SNMP Ver 1) is used for m onitoring and co nfiguring of different entities in a network. The system's SNMP Agent resp ond s to requests from SNMP Managers (a PC program etc.). SNMP[...]

  • Страница 223

    Administrator Settings 223 4.8.2.5 IP Services NTP IP This is the NTP time server address from whi c h the system can get updated time information. This is a requirement for proper o pe ratio n if H.235 authentication is implemented. The Network Time Protocol (NTP) i s used to sync hronize the time of the system to a reference time server. The NTP [...]

  • Страница 224

    TANDBERG Maestro MXP 224 4.8.2.6 Quality of Service QoS Type Off No QoS is used. Diffserv Diffserv QoS method is used. Please see belo w for d etails. IP Precedence IP Precedence QoS method is used. Please see below for details. IP Precedence Video Used to define which priority audio, video, dat a and signalin g should have in the network. Th e hig[...]

  • Страница 225

    Administrator Settings 225 Auto will provide the following priority: Audio 4 Diffserv Video Used to define which priority Audio, Video, Da ta and Signaling packets sho uld h ave in an IP network. The priority ranges from 0 to 63 for each type of packets. Diffserv Telephony Used to define which priority Audio packets sh oul d have in an IP network f[...]

  • Страница 226

    TANDBERG Maestro MXP 226 4.8.2.7 IEEE 802.1x 802.1X The system may be connected to an IEEE 802.1x LAN network. Supported 8 02.1x protocols are EAP-MD5, EAP-PEAP and EAP-TTLS. The 802.1x authent ication are enabled by setting 802.1x Mode to On. On 802.1x authentication enabled Off 802.1x authentication disabled Anonymous Identity The 802.1x Anonymou[...]

  • Страница 227

    Administrator Settings 227 4.8.3 Network Profiles This menu consists of 7 network profiles; a prefix can be added for each profile. If you add a prefix to a profile, this prefix will automatically be added in front of the number being dialed. Example: 0 is added as a Call Prefix to the 2nd profile, ISDN. If you enter 12345678 in the dial menu and s[...]

  • Страница 228

    TANDBERG Maestro MXP 228 4.8.4 Data Port The system provides up to two standard RS232 seri al ports to allow a computer to be conne ct ed for data transfer and control purposes. Note that wh en co nnecting to a PC the connecting cable must be a straight through RS232 cabl e. Baud Rate, Parity, Databits and Stop bits If you wish to connect a PC to D[...]

  • Страница 229

    Administrator Settings 229 4.8.5 Restore Default Settings Restore Default Settings will restore all administrator settings. Note that this will not affect your Call Directory information, Network Typ e, Line Setup numbers or your SPID numbers.[...]

  • Страница 230

    5 Peripheral Equipment Using the optional peripheral device s outlined in this chapter and the many others available, you will be able to build your own applications for us e with the system, thereby better integrating the system into your business environ ment. This chapter will explain how to connect periphe ral equipment to your system. First of[...]

  • Страница 231

    Peripheral Equipment 231 5.1 Interfaces 5.1.1 Video 5 Video Inputs:  2 video inputs supporting S-Video throu gh Mini-DIN connectors.  2 video inputs supporting comp osite signals through RCA conn ect ors.  1 VGA/DVI-I (DVI = Digital Video Interface, I = Integrated Digital & Analog) in pu t, analog or digital.  (use VNC as a 6th vide[...]

  • Страница 232

    TANDBERG Maestro MXP 232 Levels:  Composite: 1 Vpp, 75 ohm  S-Video (Y/C):  Y: 1 Vpp, 75 ohm  C (PAL): 0.3 Vpp, 75 ohm  C (NTSC): 0.28 Vpp, 75 ohm VGA formats supported on 'DVI-I out': SVGA (800x600) 75Hz XGA (1024x768) 60Hz WXGA (1280x768) 60Hz HD720p (1280x720) 50,60 Hz DVI and specifications: DVI stands for Digital Video[...]

  • Страница 233

    Peripheral Equipment 233 Supported DVI cables: TANDBERG supports DVI-D Single -Lin k , DVI- A and DVI-I Single-Link format cables. DVI-D cables transmit digital T.M.D.S. signal s, DVI-A cabl es transmit analog VGA signals a nd DVI-I cables can transmit either digital or anal og signals. It is possible to extend existing DVI cables by the use of ext[...]

  • Страница 234

    TANDBERG Maestro MXP 234 PC cable, VGA - DVI with integrated audio Signal name CONN. 1 CONN. 2 CONN. 3 CONN. 4 CONN. 5 Cable color DDC Clock 6 15 Orange DDC Data 7 12 White Vertical Sync 8 14 Yellow DDC Power (+5V) 14, 16 9 Red Digital return 15 5, 10 Black RGB Red C1 1 Red Coax RGB Green C2 2 Green Coax RGB Blue C3 3 Blue Coax Horizontal Sync C4 1[...]

  • Страница 235

    Peripheral Equipment 235 5.1.2 Audio 6 Audio Inputs:  3 microphone inputs (balanced, 24V pha ntom powere d) via XLR connectors.  3 audio inputs (line level) via RCA connectors. All audio inputs are active by default. For further information, refer to chapter Audio . Audio input connector specification: Connector label Microphone(s) Audio inpu[...]

  • Страница 236

    TANDBERG Maestro MXP 236 Audio output connector specific ation : Connector label Audio outputs Signal type Unbalanc ed Connecto r (codec) Female RCA/phon o, sleeve-g round, centre-signal Output impedance 680 ohm s Max output level when set to maximum output level and volume control set to max. Max output level when set to minimum output level and v[...]

  • Страница 237

    Peripheral Equipment 237 ISDN BRI Interface: ISDN I.420 (RJ-45 Jack) Basic Rate In terface S/T (2B+D), 128 kbps per ISDN I /F To connect the system to BRI, use the ISDN cable provided by TANDBERG (or a standard BRI cable). The pinout of the S/T interface is: BRI Pinout Pin-3 TX+ Pin-4 RX+ Pin-5 RX- Pin-6 TX- ISDN PRI Interface: 1 x PRI (RJ-45 Jack)[...]

  • Страница 238

    TANDBERG Maestro MXP 238 V35: V.10 (RS423). For balanced signals a "0" =low voltage is defined as terminal A positive with respe ct to terminal B. For unbalanced signals a "0"= low volta ge is defin ed as terminal positive with respe ct to GND. Cable length max: Leased Line Control = 20 Mete r[...]

  • Страница 239

    Peripheral Equipment 239 RS449: RS366: All balanced inputs and outputs (A an d B) use bala nced line signals according to V.11 (RS42 2) and single ended si gnal s in accordance with V.10 (RS 423). For balanced signals a "0" =low voltage is defined as terminal A positive with respe ct to terminal B. For unbalanced signals a "0"= [...]

  • Страница 240

    TANDBERG Maestro MXP 240 All signals are electrically according to RS232. Cable length max: 5 meter X21:[...]

  • Страница 241

    Peripheral Equipment 241 All balanced inputs and outputs (A an d B) use bala nced line signals according to V.11 (RS42 2) and single ended si gnal s in accordance with V.10 (RS 423). For balanced signals a "0" =low voltage is defined as terminal A positive with respe ct to terminal B. For unbalanced signals a "0"= low volta ge i[...]

  • Страница 242

    TANDBERG Maestro MXP 242 5.1.4 Data port The data port(s) are imple mented as Data Comm unications Equipment (D CE). The connectors used are female 9-pin D-subs. The TANDBERG main camera is n orm ally connected to data port 2 and pin number 4 provides 12V DC / 1 Amps to the main camera. Otherwise the pin-outs for both data ports are the sa me. Sign[...]

  • Страница 243

    Peripheral Equipment 243 5.2 Document Camera A document camera can be used for sho wing text, diagram s and a variety of graphical material as well as small three-dimensio nal obje cts. How to use a document camera with your system: 1. Connect the document camera to the Do c Cam input, if available, on the system. 2. Open the Presentation menu from[...]

  • Страница 244

    TANDBERG Maestro MXP 244 5.3 DVD / VCR DVD/VCR Playback Mono For playback, connect a cable between Video Out on the VCR and Video In (VCR) on the system. Connect a cable between Audio Out on t he VCR a nd the Audio In (VCR) on the system. Choose VCR from the Presentation menu to activate the VCR in put . Make sure that Audio In (VCR) is On (see cha[...]

  • Страница 245

    Peripheral Equipment 245 5.4 Additional Cameras Extra fixed Cameras You can connect extra fixed camera s to your sy stem, for example, a whiteboard camera. Con nect the video output of the additional camera to one of the available Video inp uts on the system. Multiple controllable Cameras Attaching multiple cameras to one system expand s visibility[...]

  • Страница 246

    TANDBERG Maestro MXP 246 5.5 Additional Microphones If your environment is such that you require more than one microphone for you r room, e.g. you have a whiteboard at a distance from your table microphone, it is possible to con nect ad ditional microphones to your system. See Appendix 4 for more information. Note that this requires a system with m[...]

  • Страница 247

    Peripheral Equipment 247[...]

  • Страница 248

    TANDBERG Maestro MXP 248 5.6 The TANDBERG DNAM and Speakers TANDBERG 6000 MXP Profile, T ANDBERG 6000 MXP, TANDBERG 7000 MXP, TANDBERG 8000 MXP and TANDBERG Maestro The TANDBERG Digital Natural Audio Module, DNAM*: The DNAM audiosystem is built on two specially designed and se parate modules; the DNAM audio amplifier and the DNAM loudsp e aker cabi[...]

  • Страница 249

    Peripheral Equipment 249 TANDBERG 6000 MXP Profile DNAM configuration Center Speakers + In tegrated Stereo Speakers The DNAM Amplifier*:  3 x 50W continuous average Center Out put Power (load specified by DNAM Ce nter Speakers).  2 x 50W continuous average Stereo Output Powe r (load specified by TANDBERG Loudspeaker Stereo Kit).  Full dyna[...]

  • Страница 250

    TANDBERG Maestro MXP 250 The DNAM Loudspeaker Cabinet (Center Spe aker s)*:  3-way Center Speaker system  Frequency range 50Hz - 2 0kHz  2 x 130mm low- and midrange loudspeakers, 8 ohm s nominal, high quality  1 x 25mm dome tweeter, 6 ohms nominal, high quality  Crossover filtered audio si gnals received from DNAM amplifier  Long [...]

  • Страница 251

    Peripheral Equipment 251 The Mini-DNAM Loudspeaker Cabinet*: The Mini-DNAM speaker cabinet specification:  2 * 15W Stereo Speakers, high quality  Frequency range 100Hz - 20kHz  Enclosed MDF speake r cabinet Integrated Stereo Speakers**:  2 * 15W Stereo Speakers, high quality  Frequency range 100Hz - 20kHz  Enclosed MDF speake r ca[...]

  • Страница 252

    TANDBERG Maestro MXP 252 5.7 Stereo Speaker Kit Note that the following applies only for system s with a stereo S/PDIF output. The Stereo Speaker Kit provides an pair of floor-s tanding lou dsp eakers in addit ion to the built-in DNAM . Using these speakers will ena bl e stereo func tionality in your system and thereby enha nce the sound experience[...]

  • Страница 253

    Peripheral Equipment 253[...]

  • Страница 254

    TANDBERG Maestro MXP 254 5.8 Telephone Add-On The system has a built in audio bri dge* that can br ing in Voice over IP (VoIP) telephony or normal telephone sites using ISDN. Note that this requires a system with mix ed audi o output (audio from local and far end ) an d one audio input without integrated echo cancelli ng. In addition to using ISDN [...]

  • Страница 255

    Peripheral Equipment 255 5.9 Dual Monitor Note that this requires a system with du al monitor vid eo output. The Dual Monitor option consists of an additi onal mo nitor, bigge r cabinet top-plate and associated cabling. The Dual Monitor can be us ed to show full screen selfview, snap shot s and Duo Video. To use the system in the Dual Monitor confi[...]

  • Страница 256

    TANDBERG Maestro MXP 256 5.10 XGA Monitors and Projectors (Optional) Some TANDBERG systems can be delivered with op tional single or dual TV/X GA monitors. It can also be connected to any DVI/VGA/PAL or NTS C display. Note that this requires a system with min imum one DVI-I output.[...]

  • Страница 257

    Peripheral Equipment 257 5.11 VESA Display Power Management Because of the tremendous amount of energy co ns um ed by monitors when operating, the system will reduce power consu m p tion and extend monitor lifecycle by su spending the (switch off) monitors and projectors when the syste m goes into sleep/standby. This applies for all VESA Display Po[...]

  • Страница 258

    TANDBERG Maestro MXP 258 5.12 Digital Monitor Power Management DMPM is monitor power management a pplied over the digital DVI interface. TANDBERG supports DMPM in softwar e F2 and ab ove. Six monitor power stat es are defined. Monitor On Power state Transmitter (TANDBERG codec) and receiver (Moni t or) a re powered and active. This po wer state is [...]

  • Страница 259

    Peripheral Equipment 259 5.13 Extended Display Identification Data (EDID) Extended Display Identification Data (EDID) is a VESA standard data format that will allow the system to communicate its ca pabilities, including vendor information like the supported VGA - formats and frequency range limits to a PC con ne cte d to the XGA/DVI input. Note tha[...]

  • Страница 260

    TANDBERG Maestro MXP 260 Tested and verified monitors, EDID & Timing Listed below are some of the monitors TANDBERG h ave tested an d verified against: ADI A715 Dell W1700 Dell W1900 EIZO L367 EIZO F730 ErgoScan 400S Hitachi CM640ET Hitachi CM769ET IBM 9494-HBO IBM G97 IBM E74 IBM 6743-60N JVC LT-23X475 JVC LT- 23C50BU JVC LT-23X576 LG L3200A L[...]

  • Страница 261

    6 Appendices Appendices:  Appendix 1: Technical Specification  Appendix 2: Bandwidth Information  Appendix 3: Environmental considerations  Appendix 4: Guidelines for setting up videoconfe ren cing rooms  Appendix 5: Security  Appendix 6: Using the file system  Appendix 7: Web Interface  Appendix 8: Connecting the system to [...]

  • Страница 262

    TANDBERG Maestro MXP 262 6.1 Appendix 1 Technical Specification SYSTEM COMPONENTS Integrated 5" LCD display, WAVE II camera, microphone, Digital Natural Audio Module (DNAM), integrated cabling, cart BANDWI DTH H.320 up to 2 Mbps H.323 up to 4 Mbps point-to-point SIP up to 4 Mbps Up to 6Mbps total MultiSite bandwidth FIREWALL T RAVERSAL TANDBER[...]

  • Страница 263

    Glossary 263 Interlaced SIF (352 x 480 pixels), Natural Video SIF (352 x 240 pixels) 400p (528 x 400 pixels) NATIVE PAL: 4CIF (704 x 576 pixels), Digital Clarity Interlaced CIF (352 x 576 pixels), Natural Video CIF (352 x 288 pixels) QCIF (176 x 144 pixels) SQCIF (128 x 96 pixels) decode only 448p (576 x 448 pixels) NATIVE PC RESOLUTIONS: XGA (1024[...]

  • Страница 264

    TANDBERG Maestro MXP 264 Downspeeding Programmable network profiles Intelligent Call Management HO on ISDN-PRI Facility Maximum call length timer Automatic SPID and line number configuration (National ISDN, GR-2941-CORE) SoftMux NATO standard KG194 / KIV-7 encr yptor support H.331 Broadcast Mode URI Dialing IP version 6 MULTISITE FEATURES H.323/H.3[...]

  • Страница 265

    Glossary 265 6.2 Appendix 2 Bandwidth information for TANDBERG endpoints Model 8000MXP, 7000MXP 6000MXP, Maestro Bandwidth Point to point ISDN / IP Standard: 768 / 3072 Option: 1920 / 4096 Standard: 768 / 3072 Option: 1920 / 4096 MultiSite Total: 3072kbps 4x768 video + 4 audio 3x1536 video + no audio Total: 6144kbps 6x1152 video + 5 audio 5x1536 vi[...]

  • Страница 266

    TANDBERG Maestro MXP 266 4x768 video + no audio 4x512 video + 3 audio Rate Matching Yes Yes Dual Stream (DuoVideo / H.239) Yes Yes Secure Conference All bandwidths All bandwidths H.264 Up to 2Mbps Up to 2Mbps Picture Mode MultiSite VS, CP4, CP5+1 VS, CP4, CP5+1 Model 990MXP / 990NET MXP 880MXP / 880NET MXP Bandwidth Point to point ISDN / IP Standar[...]

  • Страница 267

    Glossary 267 Model 770MXP 1000MXP Bandwidth Point to point ISDN / IP Standard: 768 (IP only) Option: 128 / 768 Standard: 768 (IP only) Options: 128 / 768, 384 / 768 MultiSite Not Available Not Available Rate Matching Not Available Not Available Dual Stream (DuoVideo / H.239) Yes Yes Secure Conference All bandwidths All bandwidths H.264 Up to 768 Up[...]

  • Страница 268

    TANDBERG Maestro MXP 268 6.3 Appendix 3 Environmental considerations This section explains how to carry out basi c adju s tments and simple tests to en sure that you send and receive the best possi ble image and audio qualit y when u sing your system. Iris control and lighting By default the system camera will use an automatic iris to compensate fo[...]

  • Страница 269

    Glossary 269 6.4 Appendix 4 Guidelines for setting up videoconferencing rooms The following are a set of guidelines to consi der when either building a videoconferen cing room, or using an existing room for video conferencing. Lighting:  Low Contrast desired for light intensity. No dark spots.  Intensity @ table 800 - 1400 Lux as measured wit[...]

  • Страница 270

    TANDBERG Maestro MXP 270 6.5 Appendix 5 Security The system has several features both to prot ect fro m unauth orized use and sy stem access: Access Code: When Access Code is enabled, the user will be as ked to enter an access code before he/ she is able to make a call. The system will verify if the entered access code is valid by checking the code[...]

  • Страница 271

    Glossary 271 By setting an IP Access Password on the s ystem, all access to the system using IP (Telnet, FTP and WEB) requires a pa ssword. This p assword can be enabled from telnet or dataport u sing the command: ippassword <ip-passwo rd >. The defaul t IP username and password is "TANDBERG". To remove this password, use the com ma[...]

  • Страница 272

    TANDBERG Maestro MXP 272 backwards compatibility) with extended Diffie Hellma n key distribution via H.320, H.323 and Leased Line con ne ctions. The TANDBERG AES implementation is validated as conforming to the Advanced Encryption Standard (AES) Algorithm, as specified in Federa l Information Processi ng Standard Publication 197, Advanced Encryptio[...]

  • Страница 273

    Glossary 273[...]

  • Страница 274

    TANDBERG Maestro MXP 274 6.7 Appendix 7 Web Interface It is possible to access and maintain the system remot ely via a local area network (LAN) usin g a standard Web-browser. Conne ct your syste m to a LAN with a Network cable. How to configure your system for web interface: 1. Open Administrator Settings an d choose Network LAN Settings 2. Specif[...]

  • Страница 275

    Glossary 275 6.8 Appendix 8 (Not available on all TANDBERG systems) Connecting the system to PRI/T1 Using CSU adapter Connecting the system to the ISDN network via the E1/T1-inte rfa ce using an Adtran T1 ESF CSU ACE or equivalent CSU, will allow up to 1.54 Mbps conne ction. The E1/T1-interface must be connected to a CSU approved according to IEC 6[...]

  • Страница 276

    TANDBERG Maestro MXP 276 6.9 Appendix 9 Connecting the system to the Switched 56 network Using Telesync TS-256 SW56/ISDN adap ter Connecting the system to the SW56 net work u sing a Telesync Adapter is described bel ow. There are different Telesync Adapters for different conf igurat ions of SW5 6 networks. The network types tested with the system a[...]

  • Страница 277

    Glossary 277 6.10 Appendix 10 Connecting the system to ISDN using NT1 network adapters Connecting Connect the first ISDN cable from ISDN 1 on t he syst em to the S-interface on your first NT1 network adapte r. Con nect the other ISDN cables to the approp riate NT1 network adapters. Connect the U-interface of your NT 1 adapter to the line provide d [...]

  • Страница 278

    TANDBERG Maestro MXP 278 6.11 Appendix 11 (Not available with set top systems) WAVE II Camera Pinouts and Connectors 8-PIN RJ (shielded modular jack): This connector is u sed fo r the power and control signals to the main camera. Pin-8 +12V (presence when connecte d in daisy chain) Pin-7 GND Pin-6 GND Pin-5 RXD (in) Pin-4 TXD (out) Pin-3 +12V Pin-2[...]

  • Страница 279

    Glossary 279 6-PIN RJ (modular jack): This connector is u sed when cascading cameras: Control (out) sig nal and external cam era detection. Note: It does not provide power for casca d ed camera. PRI Pinout Pin-6 GND Pin-5 GND Pin-4 RXD (in) Pin-3 TXD (out) Pin-2 Presence (+12V in daisy chain) Pin-1 GND Multiple Camera support: The figure below is a[...]

  • Страница 280

    TANDBERG Maestro MXP 280 Dimensions Front view: Sid e view : Re ar view : Underside vie w :[...]

  • Страница 281

    Glossary 281 6.12 Appendix 12 Remote Control (TRC 3 / TRC4) The TANDBERG remote control transmits IR -signals usin g the following parameters: Protocol Siemens SDA2208 Reference frequency 485kHz Address 4 & 7 IR wavelength 940nm IR carrier frequency 30kHz[...]

  • Страница 282

    TANDBERG Maestro MXP 282 Remote Control keycode map: Button codes Remote control (TRC 3 / TRC 4) Button codes Remote Control (TRC 3) Remote Control (TRC 4) Dec Hex Address Button name Dec Hex Address Button name Address Button name 0 00 33 21 0 OK 0 OK 1 01 0 NUMBER 1 34 22 0 CALL 0 CALL 2 02 0 NUMBER 2 35 23 0 END CALL 0 END CALL 3 03 0 NUMBER 3 3[...]

  • Страница 283

    Glossary 283 6.13 Appendix 13 Cisco CallManager registration Configuring an H.323 client on the CallManager 4.0 The registration of a H.323 client in CallM anager is supported on t he CallManager (CCM) 4. 0 software and forward. 1. To configure the CallManager with an H. 323 client, log on to the administration web interface and go to the pho ne co[...]

  • Страница 284

    TANDBERG Maestro MXP 284 6.14 Appendix 14 Diagnostic Tools for IP To use these tools, will require u sing a P C and setting up a telnet session towards the syste m . Q.931 To show Q.931 trace during a call you n eed to issue the command ‘syslo g on’. One can get traces for RAS, Q.931 and H.245 with th is command. It is a complex trace and re qu[...]

  • Страница 285

    Glossary 285 Function Port Typ e Gatekeeper Discovery (RAS) 1719 UDP Q.931 Call Setup 1720 TCP H.245* Range 5555-5574 TCP Video Range 2326-2405 UDP Audio Range 2326-2405 UDP Data/FECC Range 2326-2405 UDP MultiSite + Duo Video (*) Note: While using MultiSite, if a site is di sconnected and re connected without terminating t he entire conference, the[...]

  • Страница 286

    TANDBERG Maestro MXP 286 6.15 Appendix 15 System Upgrade Before starting the software upgrade of the TA NDBE RG MXP system, please make sure to have the new software file, (for instance s0500 00F 30.pkg ) a nd the Rel ease Key for this software available. Your TANDBERG Partne r will provide this for you. All options and settings will automatically [...]

  • Страница 287

    Glossary 287 Figure 1 3. Enter the Release key in the ‘Release Key’ field and press the ‘Install Software’ button.[...]

  • Страница 288

    TANDBERG Maestro MXP 288 A new page will now be displayed: Figure 2 4. Type in the path to where the new software file is stored, or sel ect the file by using the ‘Browse’ button. 5. The progress for the sw upgrade can be tracked by pressing the ‘telnet’ link in the help text box BEFORE pressing the install button. Please note that this is [...]

  • Страница 289

    Glossary 289 5. Type in your IP password (def ault is “TANDBERG”) a s pa ss word. 6. Type ‘put <software file name> and press Ente r. The new software file will now be uploaded to the TANDBERG MXP system. 7. When the software upload is com plete, end the ftp connection to the TANDBERG MXP system by typing ‘bye’ in the DOS prompt. 8.[...]

  • Страница 290

    TANDBERG Maestro MXP 290 Figure 3 5. Enter the release key for the system to be upgraded in the ‘Rele ase Key’ field. If no release key is given, the Far End System will use the prev iously stored release key if possible. This will work when upgrading from a main release to a dot relea se. 6 Make sure the setting “Far End System Upgrade ” i[...]

  • Страница 291

    Glossary 291 6.16 Appendix 16 Declaration of Conformity[...]

  • Страница 292

    TANDBERG Maestro MXP 292 7 Glossary # 199 AV1: External input for the TANDBERG/LOEWE monitor. 2nd monitor: The second monitor of yo ur video conferencing system. The se cond monitor is normally placed on the right side of the first monitor. 4CIF: 4 times CIF, 704x576 pixels 4SIF: 4 times SIF, 704x480 pixels A AACLD: Advanced Audio Coding Low Delay [...]

  • Страница 293

    Glossary 293 B Bandw idth: Decides the quality of the video call. High bandwidth gives high q uality. C Call Control Data Triggered: Uses TxData, RxData and clock signals o nly. Use Data Tri ggered when no handshake sig nal is available. Call control Leased Line: Is a non-dialing protocol a nd sh ould b e used when two systems are connected in a po[...]

  • Страница 294

    TANDBERG Maestro MXP 294 Diagnostics: Allows testing of individual system co mponents an d displ ays the current system settings. Digital ClarityTF: Participants enjoy presentations o f ex ceptionally high quality resolution video. Disconnect site: As a Chairma n, you get the option to Disconnect site. Disconnect site allows you to disconnect any p[...]

  • Страница 295

    Glossary 295 G G.711: Audio algorithm for normal qualit y audio (tel ephone quality, 3.1 kHz) The system will always have G.711 enabled. G.722: Audio algorithm for high quality audio (7 kHz). G.722.1: Audio algorithm for compressed high qu ality audio (7 kHz) G.728: Audio algorithm for compressed normal quality audio (telephone q uality, 3.1 kHz) G[...]

  • Страница 296

    TANDBERG Maestro MXP 296 M Main Camera: Your camera. Video input 1 Max call length: This feature will automatically end both incomin g and outgoing calls when the call time exceeds the length specified. Max channels: Indicates the maximum numbe r of channels the system is allo wed to use on the E1/T1 interface. MCU: Multipoint Conference Unit. MCU [...]

  • Страница 297

    Glossary 297 Non Standard Facility: The network provider may require service selection in your ISDN configuration. Valid NSF codes are from 1 to 31. 0 will disable NSF service codes. NR: Noise Reduction. Re duces constant background noise (e.g. noise from air-conditioning systems, cooling fans, etc. ). NSF: Non Standard Facility. NTSC: National Tel[...]

  • Страница 298

    TANDBERG Maestro MXP 298 Restart: Restart s the syst e m. Restore defaults: Re stores system settings to the factory defaults. Restricted call: A call to a 56 kbps network. By default t he system will dial an unrestricted call (a call to a 64 kbps network) and down speed to 56 kbps if necessary. S S-VHS: S-video S-video: The standard camera u se s [...]

  • Страница 299

    Glossary 299 Streaming Source: Select between local video and/ or far end video to be streamed. Local and far end audio is always streamed. Streaming TTL/Router Hops: Used for streaming d ata to limit how many ro ute rs the data should pass before it is rejected. Streaming Video Rate: Defines the Video strea ming rate from the system. SVGA: Super V[...]

  • Страница 300

    TANDBERG Maestro MXP 300 W WAVE II Camera: Wide Angle View Camera - delivers the wide st angle of view in the industry. Welcome menu: The welcome menu di splays the main menu when you are ou tside a call. X XGA: extended Graphi cs Array (1024 x 768)[...]

  • Страница 301

    8 Index A Access Co de....................................104, 129 Add Another Call........................................ 50 Additional mi cropho ne ............................. 245 Administrator Passwo rd ...........................145 Alert S peaker ...........................................185 Alert Tones a nd Volu me .......................[...]

  • Страница 302

    TANDBERG Maestro MXP 302 PIP Plac ing .............................................. 160 Postpone 1 hour ........................................ 58 Postpone 3 hours....................................... 59 Presentation Presentation Key ............................82, 156 Presentati on Menu ................................. 83 Presentation Source [...]