Alcatel Carrier Internetworking Solutions ACT 250 Bedienungsanleitung
- Schauen Sie die Anleitung online durch oderladen Sie diese herunter
- 29 Seiten
- 1.1 mb
Zur Seite of
Ähnliche Gebrauchsanleitungen
-
Telephone
Alcatel Carrier Internetworking Solutions 4018
2 Seiten 0.59 mb -
Switch
Alcatel Carrier Internetworking Solutions 6600
130 Seiten 1.09 mb -
Network Router
Alcatel Carrier Internetworking Solutions 1353
12 Seiten 0.92 mb -
Conference Phone
Alcatel Carrier Internetworking Solutions Conference Phone
144 Seiten 3.92 mb -
Switch
Alcatel Carrier Internetworking Solutions 4324
44 Seiten 0.57 mb -
Telephone
Alcatel Carrier Internetworking Solutions One Touch 531
72 Seiten 1.52 mb -
Network Card
Alcatel Carrier Internetworking Solutions 3600
10 Seiten 0.44 mb -
Switch
Alcatel Carrier Internetworking Solutions 6800
614 Seiten 4.16 mb
Richtige Gebrauchsanleitung
Die Vorschriften verpflichten den Verkäufer zur Übertragung der Gebrauchsanleitung Alcatel Carrier Internetworking Solutions ACT 250 an den Erwerber, zusammen mit der Ware. Eine fehlende Anleitung oder falsche Informationen, die dem Verbraucher übertragen werden, bilden eine Grundlage für eine Reklamation aufgrund Unstimmigkeit des Geräts mit dem Vertrag. Rechtsmäßig lässt man das Anfügen einer Gebrauchsanleitung in anderer Form als Papierform zu, was letztens sehr oft genutzt wird, indem man eine grafische oder elektronische Anleitung von Alcatel Carrier Internetworking Solutions ACT 250, sowie Anleitungsvideos für Nutzer beifügt. Die Bedingung ist, dass ihre Form leserlich und verständlich ist.
Was ist eine Gebrauchsanleitung?
Das Wort kommt vom lateinischen „instructio”, d.h. ordnen. Demnach kann man in der Anleitung Alcatel Carrier Internetworking Solutions ACT 250 die Beschreibung der Etappen der Vorgehensweisen finden. Das Ziel der Anleitung ist die Belehrung, Vereinfachung des Starts, der Nutzung des Geräts oder auch der Ausführung bestimmter Tätigkeiten. Die Anleitung ist eine Sammlung von Informationen über ein Gegenstand/eine Dienstleistung, ein Hinweis.
Leider widmen nicht viele Nutzer ihre Zeit der Gebrauchsanleitung Alcatel Carrier Internetworking Solutions ACT 250. Eine gute Gebrauchsanleitung erlaubt nicht nur eine Reihe zusätzlicher Funktionen des gekauften Geräts kennenzulernen, sondern hilft dabei viele Fehler zu vermeiden.
Was sollte also eine ideale Gebrauchsanleitung beinhalten?
Die Gebrauchsanleitung Alcatel Carrier Internetworking Solutions ACT 250 sollte vor allem folgendes enthalten:
- Informationen über technische Daten des Geräts Alcatel Carrier Internetworking Solutions ACT 250
- Den Namen des Produzenten und das Produktionsjahr des Geräts Alcatel Carrier Internetworking Solutions ACT 250
- Grundsätze der Bedienung, Regulierung und Wartung des Geräts Alcatel Carrier Internetworking Solutions ACT 250
- Sicherheitszeichen und Zertifikate, die die Übereinstimmung mit entsprechenden Normen bestätigen
Warum lesen wir keine Gebrauchsanleitungen?
Der Grund dafür ist die fehlende Zeit und die Sicherheit, was die bestimmten Funktionen der gekauften Geräte angeht. Leider ist das Anschließen und Starten von Alcatel Carrier Internetworking Solutions ACT 250 zu wenig. Eine Anleitung beinhaltet eine Reihe von Hinweisen bezüglich bestimmter Funktionen, Sicherheitsgrundsätze, Wartungsarten (sogar das, welche Mittel man benutzen sollte), eventueller Fehler von Alcatel Carrier Internetworking Solutions ACT 250 und Lösungsarten für Probleme, die während der Nutzung auftreten könnten. Immerhin kann man in der Gebrauchsanleitung die Kontaktnummer zum Service Alcatel Carrier Internetworking Solutions finden, wenn die vorgeschlagenen Lösungen nicht wirksam sind. Aktuell erfreuen sich Anleitungen in Form von interessanten Animationen oder Videoanleitungen an Popularität, die den Nutzer besser ansprechen als eine Broschüre. Diese Art von Anleitung gibt garantiert, dass der Nutzer sich das ganze Video anschaut, ohne die spezifizierten und komplizierten technischen Beschreibungen von Alcatel Carrier Internetworking Solutions ACT 250 zu überspringen, wie es bei der Papierform passiert.
Warum sollte man Gebrauchsanleitungen lesen?
In der Gebrauchsanleitung finden wir vor allem die Antwort über den Bau sowie die Möglichkeiten des Geräts Alcatel Carrier Internetworking Solutions ACT 250, über die Nutzung bestimmter Accessoires und eine Reihe von Informationen, die erlauben, jegliche Funktionen und Bequemlichkeiten zu nutzen.
Nach dem gelungenen Kauf des Geräts, sollte man einige Zeit für das Kennenlernen jedes Teils der Anleitung von Alcatel Carrier Internetworking Solutions ACT 250 widmen. Aktuell sind sie genau vorbereitet oder übersetzt, damit sie nicht nur verständlich für die Nutzer sind, aber auch ihre grundliegende Hilfs-Informations-Funktion erfüllen.
Inhaltsverzeichnis der Gebrauchsanleitungen
-
Seite 1
ACT 250 TURBOMOLECULAR PUMP CONTROLLER FOR A TP 150 AND A TP 400 A TP Series User’ s Manual addendum[...]
-
Seite 2
Contents ACT 250 addendum Alcatel V acuum T echnology France - ACT 250 addendum 1 January 2001 Commissioning Presentation ■ The ACT 250 controller . . . . . . . . . . . . . . ■ p. 3 ■ Main characteristics . . . . . . . . . . . . . . . . ■ p. 3 ■ Accessories . . . . . . . . . . . . . . . . . . . . . . ■ p. 4 ■ ■ Pump supply cable ■[...]
-
Seite 3
Contents ACT 250 addendum Alcatel V acuum T echnology France - ACT 250 addendum 2 January 2001 Use Commissioning (continued) ■ Controlling the pump from the ACT 250 controller . . . . . . . . . . . . . . . . . ■ p. 24 ■ Controller functions . . . . . . . . . . . . . . . . . ■ p. 26 ■ ■ Precautions ■ ■ Operation in local mode ■ ■[...]
-
Seite 4
Presentation Alcatel V acuum T echnology France - ACT 250 addendum 3 January 2001 The ACT 250 controller Dear Customer , Y ou have just bought an ACT 250 controller . In order to ensure the best possible performance of the equipment and your complete satisfaction in using it, we advise you to read this addendum carefully before attempting to servic[...]
-
Seite 5
Presentation Alcatel V acuum T echnology France - ACT 250 addendum 4 January 2001 Accessories Pump power supply cable The controller is connected to the pump using a corresponding power supply cable, ordered separately . Cable length (m) Par t No. 1 105086 1.5 A458885 3.5 101812 5 101810 10 101811 15 105303 20 A458478 Kit Par t No. USA 108935 Europ[...]
-
Seite 6
Presentation Alcatel V acuum T echnology France - ACT 250 addendum 5 January 2001 ACT 250 “ box ” controller control modes Local control mode A C T 2 5 0 A C T 2 5 0 POWER FAUL T SPEED STAR T STOP 1 2 Pump start-up switch Pump stop switch Pump status indicators Controller power and fault indicators Remote control The remote control Established [...]
-
Seite 7
Presentation Alcatel V acuum T echnology France - ACT 250 addendum 6 January 2001 ACT 250 “ OEM ” controller control modes Pump start-up switch Pump stop switch Pump status indicators Controller power and fault indicators Local control mode 2 1 Remote control The remote control Established by the REMOTE connector which: - provides remote contro[...]
-
Seite 8
Presentation Alcatel V acuum T echnology France - ACT 250 addendum 7 January 2001 ACT 250 controller technical characteristics Characteristic Unit ACT 250 “ box ” ACT 250 “ OEM ” W eight kg 1.8 1.3 Dimensions H xWxD m m 128.4 × 106.3 × 220 95 × 100 × 212 3U × 1/4 Rack Nominal voltage V 85 - 265 Frequency Hz 50/60 Maximum power W 300 Ma[...]
-
Seite 9
Presentation Alcatel V acuum T echnology France - ACT 250 addendum 8 January 2001 ACT 250 controller technical characteristics RS232 / 48 5 PU MP RE M OT E PO W ER SUPPL Y 212 4t r Ø 3 ,2 P O W ER SUPPLY F A U LT < S PEED A T S PEED S TART S T O P 153 ,1 8 mini . L1 L2 T 4 ,75 9 0 , 15 18 , 6 7 95 m a xi . 100 ACT 250 “ OEM ” dimensions (in[...]
-
Seite 10
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 9 January 2001 Safety instr uctions Before switching on the controller , the user should study the manual and follow the safety instructions listed in the compliance cer ti fi cate booklet supplied with the pump. See sheet B10 in the A TP pump User Manual.[...]
-
Seite 11
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 10 January 2001 ACT 250 controller electrical connections Connect the RS232/485 serial link cable to the connector (cable and PC supplied by customer) ■ If the controller is remote controlled, make the various connections on the REMOTE connector (see page 13 for wiring details). [...]
-
Seite 12
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 11 January 2001 ACT 250 remote connector characteristics When units containing the control circuits are equipped with dr y contact outputs, it is the customer's responsibility to use the outputs in compliance with safety regulations. V oltage control mode Principle of voltage-[...]
-
Seite 13
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 12 January 2001 ACT 250 remote connector characteristics Signalling on output contacts These are dr y contacts (48 V AC - 1 A) which replicate pump status information. When the output contact is closed: 1 6 2 7 3 8 4 9 1 - 6 The pump has reached the selected speed 2 - 7 The pump is[...]
-
Seite 14
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 13 January 2001 ACT 250 remote connector wiring Use in local mode ■ Standard connector plug (factor y wired) Use in remote control mode ■ Without galvanic isolation (not recommended) Wiring seen from solder side. ■ With galvanic isolation (recommended) Wiring seen from solder[...]
-
Seite 15
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 14 January 2001 RS 232 / 485 serial link Wiring the RS 232 or RS 485 serial link See sheet B 110 in the A TP Series Pump User Manual. Con fi guring the RS 232 or RS 485 serial link The link is con fi gured using switches on the rear panel of the controller . 01 Switch description[...]
-
Seite 16
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 15 January 2001 Detailed description of RS commands Syntax conventions applicable to all commands Status values Error messages ADR Syntax Result adr = address, from 000 to 255 <CR> Carriage Return (ascii 13) <LF> Line Feed (ascii 10); shown in brackets as it is not comp[...]
-
Seite 17
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 16 January 2001 Detailed description of RS commands CKS Syntax Result CYC Syntax Result Enables or disables checksums on reply strings #adr CKS ON<CR>[<LF>] Enables the ASCII checksum character at the end of a reply string or #adr CKS OFF<CR>[<LF>] Disables [...]
-
Seite 18
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 17 January 2001 Detailed description of RS commands DLI Syntax Result See also: DLR DLR Syntax Result See also: DLI, LNG, SEP , SHT Enables DataLogger operation (RS232 only) #adr DLR <CR>[<LF>] #adr ,sssss,nnnnn,iiii,ttttt,uuuu.o,www ,ppp,vvv Returns current values : ss[...]
-
Seite 19
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 18 January 2001 Detailed description of RS commands HDR Syntax Result IDN Syntax Result Identi fi es the device which is communicating, and its software version #adr IDN <CR>[<LF>] #adr , VS.... - Vx.zz ’ or #adr , VS.... - Vx.zz for “ Alcatel pump type ” Returns[...]
-
Seite 20
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 19 January 2001 Detailed description of RS commands LEV Syntax Result LNG Syntax Result See also: SHT Returns the state of the parameters de fi ned by SET #adr LEV <CR>[<LF>] #adr ,nnnnn,sssss,aaaa,hhhhh or #adr ,nnnnn rpm,sssss rpm,aaaa mA,hhhhh hours Returns the curr[...]
-
Seite 21
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 20 January 2001 Detailed description of RS commands OPT Syntax Result See also: SEL Used to select possible user choices #adr OPT2 n<CR>[<LF>] choice of temperature unit: n = 0 : degrees Centigrade n = 1 : degrees Fahrenheit #adr ,ok Comment: The choice of the temperatu[...]
-
Seite 22
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 21 January 2001 Detailed description of RS commands SBY Syntax Result See also: NSP , RPM Switches the speed set point to the stand-by value #adr SBY <CR>[<LF>] #adr ,ok Resets the stand-by speed to its last stored value, and allows it to be modi fi ed if an “ RPM ?[...]
-
Seite 23
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 22 January 2001 Detailed description of RS commands SET Syntax Result See also: LEV SHT Syntax Result See also: LNG SPD Syntax Result See also: LNG , SHT De fi nes the internal operating parameters #adr SET 1 hhhhh<CR>[<LF>] : maintenance time limit 000<hhhhh<655[...]
-
Seite 24
Commissioning Alcatel V acuum T echnology France - ACT 250 addendum 23 January 2001 Detailed description of RS commands ST A Syntax Result TMP Syntax Result Returns the status of the internal dynamic parameters #adr ST A <CR>[<LF>] #adr ,xxxxxx,yyyyyy ,zzzzzz,sssss,iiii,www ,ppp,vvv ,ttttt<CR><LF> adr: address 543210 xxxxxx [...]
-
Seite 25
Use Alcatel V acuum T echnology France - ACT 250 addendum 24 January 2001 Controlling the pump from the ACT 250 controller Once all connections are complete, plug the controller into the mains. A C T 2 5 0 A C T 2 5 0 POWER F AUL T SPEED ST ART STOP Indicator lights “ box ” version “ OEM ” version Y ellow lit Controller on Red lit Controlle[...]
-
Seite 26
Use Alcatel V acuum T echnology France - ACT 250 addendum 25 January 2001 Controlling the pump from the ACT 250 controller ST ART STOP Star ting the pump with the ST AR T switch Stopping the pump with the STOP switch The pump is started up to reach the selected speed. The yellow rising speed indicator light comes on. When the pump reaches its selec[...]
-
Seite 27
Use Alcatel V acuum T echnology France - ACT 250 addendum 26 January 2001 Controller functions Precautions Local mode operation The Start and Stop functions use switches located on the front panel of the “ box ” version and on the board for the “ OEM ” version. The “ OEM ” version of the ACT 250 has been designed with electrical safety [...]
-
Seite 28
Use Alcatel V acuum T echnology France - ACT 250 addendum 27 January 2001 Controller functions Fault monitoring ■ Aler ts are indicated by: - fl ashing red indicator . The pump power supply is maintained. ■ Faults are indicated by: - lit red indicator . The pump is stopped as soon as a fault is detected. Alerts and faults shown by the indicato[...]
-
Seite 29
France Alcatel V acuum T echnology - France 98, avenue de Brogny - BP 2069 74009 ANNECY - Cedex T el : (33) 4 50 65 77 77 Fax : (33) 4 50 65 77 89 Germany Alcatel Hochvakuum T echnik GmbH Am Kreuzeck 10 D – 97877 WERTHEIM T el: (49) 9342 96100 Fax: (49) 9342 961030 Italy Alcatel V acuum Systems S.p.A Via T rento, 30 20059 VIMERCA TE (MI) T el : ([...]