Bosch Appliances D7212G manual
- Consulta online o descarga el manual de instrucciones
- 68 páginas
- 2.33 mb
Ir a la página of
manuales de instrucciones parecidos
-
Home Security System
Bosch Appliances D1260
100 páginas 8.44 mb -
Home Security System
Bosch Appliances UNPC
12 páginas 0.42 mb -
Home Security System
Bosch Appliances DS7447E
100 páginas 4.25 mb -
Home Security System
Bosch Appliances BLCC110U
32 páginas 2.38 mb -
Home Security System
Bosch Appliances MIC-WKT-IR
13 páginas 1.03 mb -
Home Security System
Bosch Appliances API-AEC21-4WRZ
2 páginas 0.21 mb -
Home Security System
Bosch Appliances 500
8 páginas 0.18 mb -
Home Security System
Bosch Appliances D7412GV3
76 páginas 5.09 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Bosch Appliances D7212G. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Bosch Appliances D7212G o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Bosch Appliances D7212G se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Bosch Appliances D7212G, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Bosch Appliances D7212G debe contener:
- información acerca de las especificaciones técnicas del dispositivo Bosch Appliances D7212G
- nombre de fabricante y año de fabricación del dispositivo Bosch Appliances D7212G
- condiciones de uso, configuración y mantenimiento del dispositivo Bosch Appliances D7212G
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Bosch Appliances D7212G no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Bosch Appliances D7212G y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Bosch Appliances en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Bosch Appliances D7212G, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Bosch Appliances D7212G, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Bosch Appliances D7212G. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Cont rol/ Communic at or D7 2 1 2G Operation and Installation Guide[...]
-
Página 2
D7212G Operation and Installation Guide Page 2 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Operation and Installation Guide[...]
-
Página 3
D7212G Operation and Installation Guide D7 2 1 2G Page 3 © 2003 Bosch Security Systems 499 8 1 38 544C Contents 1 .0 Introduction ......................................................................................................................................................... 9 1 . 1 Guide Organization ......................................[...]
-
Página 4
D7212G Operation and Installation Guide Page 4 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Contents 4.0 Power Supply ................................................................................................................ .................................. 25 4. 1 Primary Power T erminals .......................................[...]
-
Página 5
D7212G Operation and Installation Guide D7 2 1 2G Page 5 © 2003 Bosch Security Systems 499 8 1 3 8544C Contents 8.0 Off-board Points ............................................................................................................ ................................ 37 8. 1 P oint (Z ON E X) Bus D7 2 1 2G T erminals .......................[...]
-
Página 6
D7212G Operation and Installation Guide Page 6 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Contents 1 1 . 5 SDI Address 88 ............................................................................................................. ..................................................... 5 4 1 1 . 5. 1 D9 1 33D C Direct Connect Programmi[...]
-
Página 7
D7212G Operation and Installation Guide D7 2 1 2G Page 7 © 2003 Bosch Security Systems 499 8 1 3 8544C Contents Figures Figure 1: System Configuration ................................................................................................. ..................................................... 1 3 Figure 2: Enclosure Mounting .............[...]
-
Página 8
D7212G Operation and Installation Guide Page 8 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Contents T ables T able 1: D72 1 2G Operation and Installation Guide Organization .................................................................. ....................... 9 T able 2: Related Document ation ......................................[...]
-
Página 9
D7212G Operation and Installation Guide D7 2 1 2G Page 9 © 2003 Bosch Security Systems 499 8 1 3 8544C 1 . 0 Introduction This guide addresses the operation and installation of the D7212G Control/Communicator only and should not be used in conjunction with the D9412G, D7412G, D9412, D9112, D9112B1, D7412, D7212 or D7212B1 Panels. Throughout this g[...]
-
Página 10
D7212G Operation and Installation Guide Page 10 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Introduction 1.2 Related Documentation T able 2 is a comprehensiv e list of all documentation (w ith par t numbers) directly related to the D7212G Control/ Com municator . Throughout this guide, ref erences are made to this documentation. If you[...]
-
Página 11
D7212G Operation and Installation Guide D7 2 1 2G Page 11 © 2003 Bosch Security Systems 499 8 1 3 8544C 1 .3.2 Tips, Notes, Cautions and Warnings Throughout this document helpful tips and notes will be presented concerning the entire application and/or programming the unit. They will be set off as follows: Applicatio n Note Application Notes shoul[...]
-
Página 12
D7212G Operation and Installation Guide Page 12 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Introduction Notes:[...]
-
Página 13
D7212G Operation and Installation Guide D7 2 1 2G Page 13 © 2003 Bosch Security Systems 499 8 1 3 8544C Overview 2. 0 Overview Use command centers and/or k eyswitches to arm the panel by area. Each panel ca n have up to four areas. Each area can have its own account numbe r or areas can be grouped toge t her with a common accoun t number . Points [...]
-
Página 14
D7212G Operation and Installation Guide Page 14 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Overview 2.2 Specifications (The black and white circles with numbers indicate the specific panel terminal.) Primary: 16.5 VAC 40 VA class 2 plug-in transformer (D1640) Voltage Input (Power S u pply) Seconda ry: Sealed lead-acid rechargeable (12[...]
-
Página 15
D7212G Operation and Installation Guide D7 2 1 2G Page 15 © 2003 Bosch Security Systems 499 8 1 3 8544C Overview Telephone Connections Telephone Line Connection RJ31X or RJ38X jack can be interfaced with the panels. Supervision supplied by the panel. Discharge Cycle 13.9 VDC 13.8 VDC 12.1 VDC 10.2 VDC Charging float level Charging Status LED on Lo[...]
-
Página 16
D7212G Operation and Installation Guide Page 16 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Overview 2.2. 1 Compatible Accessories See the Bosch Security Systems Intrusion Catalog for a complete list. D122 Dual Battery Harness D1256 Fire Command Center D125B Powered Loop Interface Module D1257 Fire A nnunciator D126 12 V, 7 Ah Recharg [...]
-
Página 17
D7212G Operation and Installation Guide D7 2 1 2G Page 17 © 2003 Bosch Security Systems 499 8 1 3 8544C Overview 2.3.3 Added Feature When Using Ground Fault Detect W hen Ground Fault Det ect is enabled (S4 closed), P oints 1-8 can be used for non-pow ered fire-initiating dev ices, such as Heat Detecto rs, 4-W ire Smoke Detectors, Pull Stations, et[...]
-
Página 18
D7212G Operation and Installation Guide Page 18 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Overview 2.4.4 Command Centers A maximum of 32 unsuperv ised co mmand centers can be connect ed to the system. The available power , number of supervised command centers, and number of areas that will be used, affect the total number of command [...]
-
Página 19
D7212G Operation and Installation Guide D7 2 1 2G Page 19 © 2003 Bosch Security Systems 499 8 1 3 8544C Overview 2.4. 1 0 Other Features The D7212G Control/Communicator has many programmable features. A short list of some of the features follows. Complete details on all the features can be found in the D7212G Program Entry Guide (P/N: 4998138538) [...]
-
Página 20
D7212G Operation and Installation Guide Page 20 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Overview The following literature is available in a separate literature package for dealers: - D7212G Approved Applications Compliance Guide (P/N: 4998138560) - D7212G Operation and Installation Guide (P/N: 4998138544) - D7212G Program Entry Gui[...]
-
Página 21
D7212G Operation and Installation Guide D7 2 1 2G Page 21 © 2003 Bosch Security Systems 499 8 1 3 8544C Installation 3. 0 Installation 3.1 Before Beginning This section contains a general installation procedure and provides references to other sections of the guide for detailed instructions. Bosch Security Systems recommends a review of this guide[...]
-
Página 22
D7212G Operation and Installation Guide Page 22 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Installation 3.4 Installing the Assembly 1 . Place the assembly over the inside back of the enclosure, aligning the large rectangular openings of the mounting skirt with the mounting hooks of the enclosure. Slide the assembly down so it hangs on[...]
-
Página 23
D7212G Operation and Installation Guide D7 2 1 2G Page 23 © 2003 Bosch Security Systems 499 8 1 3 8544C Releasing the reset pin from the closed position resets the panel. The panel resets all its timers, counters, indexes, and buffers. Any points that restore after a reset is performed will not generate restoral reports. If the reset pin is placed[...]
-
Página 24
D7212G Operation and Installation Guide Page 24 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G 3.6.4 Make t he T elephone Connect ions See Sec tion 6.0 T e lephone Connections on page 31. If c onnecting the panel to a g round start phone system , install a D136 relay , see Sec tion 3.6.3 Install Mod ules and Relays on page 23. 3.6.5 Conne[...]
-
Página 25
D7212G Operation and Installation Guide D7 2 1 2G Page 25 © 2003 Bosch Security Systems 499 8 1 3 8544C Power Supply 4 . 0 Power Supply 4.1 Primary Power Terminals 4. 1 . 1 Primary (AC) Power Circuit A 16.5 V AC, 40 V A internally fuse d transformer (Bosch Securit y Systems D1640) is the primar y po wer source. The A C power circuit provides 1.9 A[...]
-
Página 26
D7212G Operation and Installation Guide Page 26 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G 4.2.2 Installing the Battery Place the battery upright in the base of the enclosure. Locate the red and black leads supplied in the literature pack. Connect the black battery lead to T erminal 4, and then to the negative (-) side of the battery [...]
-
Página 27
D7212G Operation and Installation Guide D7 2 1 2G Page 27 © 2003 Bosch Security Systems 499 8 1 3 8544C 4.2.4 Battery Supervision When the battery voltage drops to 13.8 VDC, the yellow Charging Status LED lights. When the battery drops to 12.1 VDC, the red Low Battery LED lights and the panel, if programmed for power supervision, transmits a BATTE[...]
-
Página 28
D7212G Operation and Installation Guide Page 28 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Power Supply 4.3 Charging Status and Low Battery LEDs LEDs Off When No rmal Charging S tatus Low Battery YEL RED Figure 6: Charging and Battery LEDs Type LED Color LED State Action Yellow S h ows the charging status o f the battery. Figur e 6 on[...]
-
Página 29
D7212G Operation and Installation Guide D7 2 1 2G Page 29 © 2003 Bosch Security Systems 499 8 1 3 8544C Power Outputs 5 . 0 Power Outputs 5.1 Circuit Protection Three P ositive T emperature Coefficients (PTCs) pr otect the panel from short circuits on both the continuous and programmable power outputs. If the panel is programmed for power supervis[...]
-
Página 30
D7212G Operation and Installation Guide Page 30 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G 5.4.2 Optional Relays Required Install an optional D136 Plug-in Relay into the AL T ALARM socket to enable the output at T erminal 7. Install a D136 in the SW A UX so ck et to enable the output at T erminal 8. The rela y sockets are under the fa[...]
-
Página 31
D7212G Operation and Installation Guide D7 2 1 2G Page 31 © 2003 Bosch Security Systems 499 8 1 3 8544C T elephone Connect ions 4 5 8 45 8 4 5 8 (TIP) (R ING) Outside TELCO Premises T elephone 1 1 1 T1 T R R1 RJ31X Jack TELCO Connect or Block RING (red) TIP (green) RJ31X 2 7 6 .0 T elephone Connect ions 6.1 Registration The Bosch Security Systems [...]
-
Página 32
D7212G Operation and Installation Guide Page 32 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G T elephone Connect ions 6.6 Operation Monitor LED (Green) The green Oper ation M onitor LED indicates the operation of the CPU ( C entral P rocessing U nit). When the CPU is operating normally , the LED flashes 0.5 sec. on, 0.5 sec. off. The gre[...]
-
Página 33
D7212G Operation and Installation Guide D7 2 1 2G Page 33 © 2003 Bosch Security Systems 499 8 1 3 8544C T elephone Connect ions 6.11 Ground Start Some telephone systems re quire a momentary g round input t o initiate dial tone. T o interface with a g r ound star t system , insert a D136 Plug-in Relay into the GND ST AR T socket and set the Phone M[...]
-
Página 34
D7212G Operation and Installation Guide Page 34 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G T elephone Connect ions Notes:[...]
-
Página 35
D7212G Operation and Installation Guide D7 2 1 2G Page 35 © 2003 Bosch Security Systems 499 8 1 3 8544C On-board Points 7 .0 On-board Points 7.1 Description Terminals The panel provides eight on-board points. Each point functions independently and does not interfere with the operation of the others. The panel monitors the sensor loops for normal, [...]
-
Página 36
D7212G Operation and Installation Guide Page 36 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G On-board Points 7.5 Wiring Information for Installations using the Ademco AB-12 Bell/Housing 1 2 3 4 5 6 Bell B e l l T a m p e r s Outer Bell Box Inner Bell Box Lining EOL 220 k Ω ½ W EARTH GR OUND COMMON BA TTERY NEGA TIVE ONL Y Maximum Cha[...]
-
Página 37
D7212G Operation and Installation Guide D7 2 1 2G Page 37 © 2003 Bosch Security Systems 499 8 1 3 8544C Off-board Points 8 . 0 Off-board Points 8.1 Point (ZONEX) Bus D7212G Terminals The D7212G can use POPIT ( P oint o f P rot ect ion I nput T ransp on der) Modules to pro vide up to 32 off-b oard points, bringing the total number of points the D72[...]
-
Página 38
D7212G Operation and Installation Guide Page 38 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Off-board Points 8.2 D8125, D8127 and D9127 POPIT Modules D8127 and D9127 POPIT s use the D8125 POPEX Module to report to the panel. The D8125 supports up to 32 POPIT points (P oints 9 to 20). The panel only annunciates activit y for each POPIT [...]
-
Página 39
D7212G Operation and Installation Guide D7 2 1 2G Page 39 © 2003 Bosch Security Systems 499 8 1 3 8544C Off-board Points Maxi mum Length of all Data Expansion Loops Combined AWG Length in ft. (m) 22 1800 (548) 20 2890 (881) 18 4600 (1402) 16 7320 (2231) 14 11650 (3551) T ab le 9: Data Expansion Loop W ire Specifications Co mbine data ex pansion lo[...]
-
Página 40
D7212G Operation and Installation Guide Page 40 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Off-board Points Figure 13: Connecting the D8125 POPEX to the D7212G Panel[...]
-
Página 41
D7212G Operation and Installation Guide D7 2 1 2G Page 41 © 2003 Bosch Security Systems 499 8 1 3 8544C Off-board Points 8.3.6 POPIT Module Point Assignments Seve n sw itches on each D9127U/T POP IT (six on each D8127U/T POPIT) assign the module to a point number . POPIT switch settings are found in Point Assignment in the D7212G Program Record Sh[...]
-
Página 42
D7212G Operation and Installation Guide Page 42 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Off-board Points POPIT Labels Off-board points for the D7212G are numbered 9 to 40. T wo sheets of peel-off POPIT lab els are sup plied with the D8125 POPEX Module. U se the sheet marked Bank1 for P oints 9 to 40. Each label has two parts. Place[...]
-
Página 43
D7212G Operation and Installation Guide D7 2 1 2G Page 43 © 2003 Bosch Security Systems 499 8 1 3 8544C Off-board Points Mounting Follow the pr ocedure below to install OctoPOPIT s in the enclosure. 1 . It is easier to set the switches on the D8128D before mounting it in the enclosure. See Section 8.4.5 Line T er mination b el ow and Sect ion 8.4.[...]
-
Página 44
D7212G Operation and Installation Guide Page 44 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Off-board Points 8.4.6 OctoPOPIT Sensor Loops Only the resistance on the loop limits the number of normally-open and/or normally-closed detection devices each sensor loop can supervise. Resistance on each sensor loop must be less than 100 Ω wi[...]
-
Página 45
D7212G Operation and Installation Guide D7 2 1 2G Page 45 © 2003 Bosch Security Systems 499 8 1 3 8544C Off-board Points SENSOR LOOPS First Addr ess on Z ONEX Bus 1 SENSOR LOOPS First Addr ess on Z ONEX Bus 1 SENSOR LOOPS First Addr ess on Z ONEX Bus 1 SENSOR LOOPS First Addr ess on Z ONEX Bus 1 EARTH GRO COMMON BA TTERY N Maxi mum Char ging Curre[...]
-
Página 46
D7212G Operation and Installation Guide Page 46 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Off-board Points Notes:[...]
-
Página 47
D7212G Operation and Installation Guide D7 2 1 2G Page 47 © 2003 Bosch Security Systems 499 8 1 3 8544C Off-board Relays 9 . 0 Off-board Relays 9.1 D8129 OctoRelay The D8129 OctoRelay allows the addition of relay outputs to the system in groups of eight. The D7212G allows up to 24 OctoRelay outputs to be added to the system. Review Section 5.0 Pow[...]
-
Página 48
D7212G Operation and Installation Guide Page 48 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Off-board Relays 12345 6 7 8 GND AUX DAT A D8129 O CTORELA YS FOR RELA Y NUMBERS 1 TO 24. CONNECT OCTORELA YS IN P ARAL L EL. EARTH GRO COM MON BATT ERY N Maximu m Charging Current 1.4 A mps. BA TTERY POSITI VE ONL Y RELA Y A RELA Y B RELA Y C +[...]
-
Página 49
D7212G Operation and Installation Guide D7 2 1 2G Page 49 © 2003 Bosch Security Systems 499 8 1 3 8544C 1 0 .0 Arming Devices 10.1 Description Command centers, maintained or momentary contact keyswitches, or a combination of the two are used to arm and disarm areas. The panel may contain up to 4 areas. See Section 2.4.2 Areas and Accounts on page [...]
-
Página 50
D7212G Operation and Installation Guide Page 50 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G 1 0.2.2 Inst alla tion Consult the command center Operation and Installation Guide for installation and mounting instructions. Command centers c onnect to the panel in par allel as shown in T able 13 . D7212 G Command Center Terminal Function Wi[...]
-
Página 51
D7212G Operation and Installation Guide D7 2 1 2G Page 51 © 2003 Bosch Security Systems 499 8 1 3 8544C Arming Devices 10.3 D279A Independent Zone Control Any on-board or OctoPOPIT point can be programmed so that the D279A Independent Zone Control operates as independent point control (arms and disarms the point). • See the Point Assignments in [...]
-
Página 52
D7212G Operation and Installation Guide Page 52 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Arming Devices Notes:[...]
-
Página 53
D7212G Operation and Installation Guide D7 2 1 2G Page 53 © 2003 Bosch Security Systems 499 8 1 3 8544C S DI Devices 1 1 . 0 S DI Devices 11.1 Description The D7212G P anel can suppor t a number of accessor y devices off the SDI bus using T erminals 29 through 32. Some devices include the Command Centers (discussed in the previous section), the D9[...]
-
Página 54
D7212G Operation and Installation Guide Page 54 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G S DI Devices 11.4 SDI Address 80 SDI Address 80 is available on the D7212G Panel and allows bi-directional SDI to RS232 information. The intent of this address is for use with home or building automation software. A D9133 Serial Interface Module[...]
-
Página 55
D7212G Operation and Installation Guide D7 2 1 2G Page 55 © 2003 Bosch Security Systems 499 8 1 3 8544C S DI Devices 1 1 .5.2 D9 1 33T TL - E Ne tw ork Interface Module The Bosch Security Systems D9133TTL-E Network Interface Module is a four-wire powered SDI device providing connection for bi-directional communication over Ethernet networks to D72[...]
-
Página 56
D7212G Operation and Installation Guide Page 56 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G S DI Devices Notes:[...]
-
Página 57
D7212G Operation and Installation Guide D7 2 1 2G Page 57 © 2003 Bosch Security Systems 499 8 1 3 8544C 1 2 . 0 Programmer and Accessory Connections 12.1 Programmer Connector The procedure below shows ho w to connect and disconnect the progr ammer . R efer to the D5200 Programmer Manual (P/N: 74-06176-000) for complete information on using the D52[...]
-
Página 58
D7212G Operation and Installation Guide Page 58 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Programmer and Accessory Connections Accessory Conn ector Programming Conn ector GRN PROG CONN Point 8 GND F AUL T Detect L E D I S A B L E DAT A BUS B COMMON ZONEX OUT 1 ZONE X IN 1 30 29 28 27 Figure 20: Programmer and Accessory Connections[...]
-
Página 59
D7212G Operation and Installation Guide D7 2 1 2G Page 59 © 2003 Bosch Security Systems 499 8 1 3 8544C Faceplate 1 3 .0 Faceplate 13.1 D7212G Faceplate Figure 21: D7212G Faceplate[...]
-
Página 60
D7212G Operation and Installation Guide Page 60 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Faceplate Notes:[...]
-
Página 61
D7212G Operation and Installation Guide D7 2 1 2G Page 61 © 2003 Bosch Security Systems 499 8 1 3 8544C Appendix A: System Wiring Diagrams, Issue A Appendix A: System Wiring Diagrams, Issue A A. 1 D7212G Control/Communicator, 1 of 3 Figure 22a: D7212G System Wiring Diagram, 1 of 3[...]
-
Página 62
D7212G Operation and Installation Guide Page 62 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Appendix A: System Wiring Diagrams, Issue A A. 2 D7212G Control/Communicator, 2 of 3 Figure 22b: D7212G System Wiring Diagram, 2 of 3[...]
-
Página 63
D7212G Operation and Installation Guide D7 2 1 2G Page 63 © 2003 Bosch Security Systems 499 8 1 3 8544C Appendix A: System Wiring Diagrams, Issue A A. 3 D7212G Control/Communicator, 3 of 3 Figure 22c: D7212G System Wiring Diagram, 3 of 3[...]
-
Página 64
D7212G Operation and Installation Guide Page 64 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Appendix A: System Wiring Diagrams, Issue A Notes:[...]
-
Página 65
D7212G Operation and Installation Guide D7 2 1 2G Page 65 © 2003 Bosch Security Systems 499 8 1 3 8544C Appendix B: Point Address Chart Appendix B: Point Address Chart B.1 ZONEX 1, Points 9 to 40 Place the labels on the base of the POPIT . Do not attach labels to the POPIT cov er . A number in the switch column indicates that the switch is set to [...]
-
Página 66
D7212G Operation and Installation Guide Page 66 © 2003 Bosch Security Systems 499 8 1 38 544C D7 2 1 2G Appendix B: Point Address Chart Notes:[...]
-
Página 67
D7212G Operation and Installation Guide D7 2 1 2G Page 67 © 2003 Bosch Security Systems 499 8 1 3 8544C Index Symbols 9000G Series Panels Differences ......................................... 1 3 A Accessories ............................................... 16 Accessory Connector .............................. 57 Accounts Standard Features .......[...]
-
Página 68
©2003 Bosch Security Systems 49 98 1 38 544C 05/03 1 3 0 Perinton Parkway , Fairport, NY 1 4450-9 1 99 U SA Operation and Installation Guide D72 1 2G Customer Ser vice: (800 ) 538-58 0 7; T echnical Support (888 ) 886-6 1 8 9 Page 68 of 68 P Phone Cords ........................................... 3 1 Phone Lines ...................................[...]