Ir a la página of
manuales de instrucciones parecidos
-
Personal Lift
Graham Field Mp7014
48 páginas 2.29 mb -
Personal Lift
Graham Field Mp707404
48 páginas 2.29 mb -
Personal Lift
Graham Field LF2020
20 páginas 0.62 mb -
Personal Lift
Graham Field MM7174
48 páginas 2.29 mb -
Personal Lift
Graham Field WHISPER LITE WL0208
1 páginas 0.15 mb -
Personal Lift
Graham Field LF2090
20 páginas 0.62 mb -
Personal Lift
Graham Field WL0208
1 páginas 0.15 mb -
Personal Lift
Graham Field LUMEX LF1030
28 páginas 0.78 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Graham Field LF1050. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Graham Field LF1050 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Graham Field LF1050 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Graham Field LF1050, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Graham Field LF1050 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Graham Field LF1050
- nombre de fabricante y año de fabricación del dispositivo Graham Field LF1050
- condiciones de uso, configuración y mantenimiento del dispositivo Graham Field LF1050
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Graham Field LF1050 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Graham Field LF1050 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Graham Field en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Graham Field LF1050, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Graham Field LF1050, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Graham Field LF1050. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
LF1050-INS-LAB-R e vE13 © 2013 GF Health Products, Inc. R ead this manual before operating y our Pa tient Lift. Sav e this manual f or future use. T he most cur r ent v er sion of this manual can be found online a t www . g rahameld.com . LF1050 P A TIENT LIFT USER MANU AL[...]
-
Página 2
LF1050-INS-LAB-RevE13 2 GF Health Pr oducts, Inc. is not responsible for typographical err ors. For the most updated and curr ent information on packaging, warranties, products and specications, including the most curr ent version of these instructions, please visit our website at www .grahameld.com. Graham-Field and Lumex ar e register ed tr[...]
-
Página 3
LF1050-INS-LAB-RevE13 3 1 INTRODUCTION Congratulations on your pur chase of the Lumex LF1050 Patient Lift. The following pages will pr ovide you with impor tant safety and operating instructions on the use of patient lifts, slings, and accessories, as well as maintenance and warranty information. Read this manual car efully before operating your pa[...]
-
Página 4
LF1050-INS-LAB-RevE13 4 2 SAFETY PRECA UTIONS IMPORT ANT: Bef or e using patient lift, please read and adhere to the following saf ety precautions and war nings. F ailure to do so could r esult in serious per sonal injur y or damage to your patient lift. Always consult your healthcar e professional to determine safe methods most suitable for your i[...]
-
Página 5
LF1050-INS-LAB-RevE13 5 WARNING: W hen transfer ring a patient, always k eep the patient centered o ver the base. WARNING: Ensure that lifting sling loops are cor rectl y attac hed to the hooks to pr ev ent the patient from sliding or falling out of the sling, w hich could result in per sonal injur y . Ne ver use the patient lift to lift or transfe[...]
-
Página 6
LF1050-INS-LAB-RevE13 6 3 FEA TURES LIFT COMPONENTS a. Boom b. Mast c. Base d. Spreader bar e. Pendant f. Actuator g. Control box h. Caster brake i. Front caster j. Emergency Low er ing Dev i ce CONTROL BO X COMPONENTS RE SET Bu tton Battery T esting Charger Plug-in Actuator Plug-in Pendant Plug-in[...]
-
Página 7
LF1050-INS-LAB-RevE13 7 4 HANDLING PROCEDURES SHIPPING AND TRANSPORT A TION INSTRUCTIONS If the patient lift is to be r eshipped by common carrier , it should be packed in the same car ton in which it was r eceived. Unpacking WARNING: T he lift is heavy . T o av oid per sonal injur y , DO NOT a ttempt to r emo ve the lift from the box without assis[...]
-
Página 8
LF1050-INS-LAB-RevE13 8 5 ASSEMBL Y INSTRUCTIONS WARNING: T he lift is heavy . T o av oid per sonal injur y , DO NOT a ttempt to assemble the lift without assistance. 1. Engage the lift brakes, as shown above. 2. Remove the bolts from the bottom of the mast and base. 3. Pull the mast, boom, and spreader bar to an upright position, as shown above. 4[...]
-
Página 9
LF1050-INS-LAB-RevE13 9 6. Place the control box in the bracket, as shown above. 7. Attach the actuator bottom to the mast bracket and inser t retainer pin, as shown above. Insert r etaining ring through r etainer pin hole to secure actuator base to mast bracket. 8. Attach the actuator top to the boom bracket and inser t retainer pin, as shown abov[...]
-
Página 10
LF1050-INS-LAB-RevE13 10 9. Attach the spr eader bar bracket to the boom and insert retainer pin, as shown above. Insert r etaining ring through r etainer pin to secure spr eader bar to boom. Pendant plug Actuator plug 10. Inser t the actuator plug into the contr ol box, as shown above. 11. Inser t the pendant plug into the contr ol box, as shown a[...]
-
Página 11
LF1050-INS-LAB-RevE13 11 CHARGING THE B A TTERIES Char ge the batteries after assembly . 1. Ensure the batter y box power switch is ON (i.e., the red button is up). 2. Inser t the charger plug into the battery box charging socket (the top slot). 3. Inser t the other charger plug into the power supply . 4. All LED indicator lights should illuminate [...]
-
Página 12
LF1050-INS-LAB-RevE13 12 6 OPERA TING INSTRUCTIONS WARNING: During lifting and low ering, w henev er possible, always k eep the base le gs of the lift in the widest position. WARNING: Use only Lumex slings specially designed for the Lume x LF1050 Patient Lift. WARNING: Do not put anything (e.g. cushion, pad, etc.) between the user and the sling. T [...]
-
Página 13
LF1050-INS-LAB-RevE13 13 Lifting the patient from a bed 1. Position patient face-up in center of bed. Roll patient onto their side facing away from you. 2. Fold sling lengthwise, outside out, and place it halfway under patient with lower edge just beneath knees and sling handle on the outside, facing away fr om patient. If the sling has a head supp[...]
-
Página 14
LF1050-INS-LAB-RevE13 14 Low ering the patient to the oor 1. Place a pillow on the base to protect the patient’ s head and neck (this is unnecessar y when using a sling with a head support). 2. Reverse the above procedur es to lower . T ransfer ring the patient from a chair to a wheelchair or commode chair WARNING: GF Health Products, Inc. r e[...]
-
Página 15
LF1050-INS-LAB-RevE13 15 T ransfer ring the patient from a bed to a w heelchair or commode c hair 1. For smooth, easy lifting, have the wheelchair or commode chair in ready position with wheel locks in locked position. 2. With patient face-up in center of bed, r oll patient onto their side away from attendant. 3. Place sling, folded lengthwise, hal[...]
-
Página 16
LF1050-INS-LAB-RevE13 16 EMERGENCY RELEASE In case of lift failur e while using the Lumex LF1050 Patient Lift, follow the procedur e below to safely lower the user . The Emer gency Lowering Device is located at the top of the actuator shaft. It is intended for use if the actuator fails to operate while a patient is suspended. T ur n c lo ck wi se t[...]
-
Página 17
LF1050-INS-LAB-RevE13 17 7 CARE AND MAINTENANCE Pr oper care and maintenance ar e essential to keeping your Lumex LF1050 Patient Lift in a safe operating condition. In addition to inspecting the unit befor e each use, periodic maintenance checks should be done. W e fur ther r ecommend that this unit be ser viced at least once annually by a Graham-F[...]
-
Página 18
LF1050-INS-LAB-RevE13 18 CLEANING Regular cleaning is r ecommended ever y three months; clean the lift mor e often as needed. A soft cloth, dampened with water and a mild NON-ABRASIVE deter gent (household cleaner , soapy water , or hospital grade disinfectant) is all that is needed to clean your patient lift. Automobile wax or furnitur e polish wi[...]
-
Página 19
LF1050-INS-LAB-RevE13 19 8 TROUBLESHOO TING The following list of encounter ed problems and their solutions will assist you in determining what may be causing your Lumex lift not to function as designed. If you have a pr oblem occurring which is not listed below , please contact your distributor or GF Health Pr oducts, Inc. T echnical Support for h[...]
-
Página 20
LF1050-INS-LAB-RevE13 20 9 SPECIFICA TIONS Info: All dimensions are given in inches unless otherwise specified. Basewidth Open:37.5" Closed:26" Baseheightclearance 4.75" Baselength 44" Liftingheightrange Info: Asmeasuredfromslinghooks. Minimum:27" Maximum:69" Range:42&qu[...]
-
Página 21
LF1050-INS-LAB-RevE13 21 10 LIMITED WARRANTY GF Health Products Inc. (“Graham-Field”) warrants this product to be free from manufacturing defects in material and workmanship for its period of warranty that is in accordance with industr y standards. This warranty is extended only to the original purchaser/consumer or dealer/non-consumer of this [...]
-
Página 22
LF1050-INS-LAB-RevE13 22 THE FOREGOING W ARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS W ARRANTIES AND IMPLIED W ARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED W ARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A P AR TICULAR PURPOSE, AND SHALL NOT EXTEND BEYOND THE DURA TION OF THE EXPRESS W ARRANTY PROVIDED HEREIN, AND THE REMEDY FOR VI[...]
-
Página 23
LF1050-INS-LAB-RevE13 23 11 INDEX A Assembly instructions 8 B Before each use 17 C Care and maintenance 17 Care of slings 18 CAUTION statement, signicance 4 Cleaning 18 F Features 6 H Handling Procedures 7 I Info statement, signicance 4 Inspection 7 Intended use 3 Introduction 3 L Lifting the patient 12 Lifting the patient from a bed 13 Lifti[...]
-
Página 24
GF Health Pr oducts, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 USA tel: 770-368-4700 fax: 770-368-2368 www .grahamfield.com[...]