MGE UPS Systems 3200C manual
- Consulta online o descarga el manual de instrucciones
- 28 páginas
- 0.84 mb
Ir a la página of
manuales de instrucciones parecidos
-
Power Supply
MGE UPS Systems 300
6 páginas 0.44 mb -
Power Supply
MGE UPS Systems EX 700
28 páginas 0.7 mb -
Power Supply
MGE UPS Systems 3000 VA
34 páginas 1.29 mb -
Power Supply
MGE UPS Systems 14+
44 páginas 0.55 mb -
Power Supply
MGE UPS Systems EX 5 RT 3:1
38 páginas 1.46 mb -
Power Supply
MGE UPS Systems EPS 7000
48 páginas 1.43 mb -
Power Supply
MGE UPS Systems 2200C
28 páginas 0.84 mb -
Power Supply
MGE UPS Systems GES-801L
22 páginas 0.11 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones MGE UPS Systems 3200C. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica MGE UPS Systems 3200C o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual MGE UPS Systems 3200C se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales MGE UPS Systems 3200C, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones MGE UPS Systems 3200C debe contener:
- información acerca de las especificaciones técnicas del dispositivo MGE UPS Systems 3200C
- nombre de fabricante y año de fabricación del dispositivo MGE UPS Systems 3200C
- condiciones de uso, configuración y mantenimiento del dispositivo MGE UPS Systems 3200C
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de MGE UPS Systems 3200C no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de MGE UPS Systems 3200C y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico MGE UPS Systems en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de MGE UPS Systems 3200C, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo MGE UPS Systems 3200C, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual MGE UPS Systems 3200C. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
34007532EN/AA - Page 1 www .mgeups.com MGE UPS SYSTEMS Installation and user manual Pulsar EX treme 2200C / 3200C T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R[...]
-
Página 2
Page 2 - 34007532EN/AA Introduction Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar EX treme C range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the [...]
-
Página 3
34007532EN/AA - Page 3 Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. Information may be found primarily by consulting: ◗ the contents, ◗ the index. Pictograms Fore[...]
-
Página 4
Page 4 - 34007532EN/AA[...]
-
Página 5
34007532EN/AA - Page 5 Contents 1. Presentation 1.1 Standard positions ....................................................................................................................... 7 Rack position .................................................................................................................................. 7 T ower pos[...]
-
Página 6
Page 6 - 34007532EN/AA Contents 4. Maintenance 4.1 T roubleshooting .......................................................................................................................... 20 4.2 Replacement of the battery module .......................................................................................... 22 5. Environment .........[...]
-
Página 7
34007532EN/AA - Page 7 1. Presentation 1.1 Standard positions Rack position Tower position Pulsar EX treme 2200C : 35.3 Kg Pulsar EX treme 3200C : 35.7 Kg 654 mm 438 mm (19") 86.5 mm (2U) w w w . m g e u p s .c o m P U L S A R EX trem e 1 0 0 % 8 0 % 5 0 % 2 0 % t e s t % 1 2 % B Y P A S S P U L S A R E X tre m e w w w . m g e u p s . c o m 1 [...]
-
Página 8
Page 8 - 34007532EN/AA 1. Presentation 1.2 Back Slot for communications-card option. RS232 communications port. USB communications port. Four outlets for direct connection of protected equipment. Two programmable outlets (outlet 1 and 2). Output circuit breakers. Socket for connection to AC-power source. Connector for an additional battery module. [...]
-
Página 9
34007532EN/AA - Page 9 1.3 Control panel Alarms Hold down to display percent load: ◗ Lamp test or buzzer OFF. ◗ Forced transfer to bypass and back by pressing button 3 times in less than 5 seconds. ON / OFF. % battery remaining 100% 80% 50% 20% 1. Presentation Status of programmable outlet 1: Operation on bypass (no backup power available). Ope[...]
-
Página 10
Page 10 - 34007532EN/AA 2. Installation 2.1 Unpacking and parts check Cord for connection to the AC-power source for Pulsar EX treme 3200C versions only (for the Pulsar EX treme 2200C version, use the power cord of the protected equipment). Two cords for connection of the protected equipment. RS232 communications cable. USB communications cable. Te[...]
-
Página 11
34007532EN/AA - Page 11 2.2 Installation in rack position 2. Installation Follow steps 1 to 6 for rack mounting of the UPS on the rails. The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS. Note for step 3: It is possible to adjust the positions of the front brackets. 1 2 5 3 3 4 2 6 2 2 1 0 0 % 8 0 % 5 0 % 2 0 % t e s t %[...]
-
Página 12
Page 12 - 34007532EN/AA 2.3 Installation in tower position 2. Installation Connect the two supports for the upright position. P U L S A R EXtrem e P U L S A R EX trem e www.mgeups.com w w w . m g e u p s . c o m 1 0 0 % 8 0 % 5 0 % 2 0 % t e s t % 1 2 % B Y P A S S[...]
-
Página 13
34007532EN/AA - Page 13 2. Installation 2.4 Connection to the RS232 or USB communications port (optional) 1 - Connect the RS232 30 or USB 31 communications cable to the serial port or the USB port on the computer. 2 - Connect the other end of the communications cable 30 or 31 to the RS232 2 or USB 3 communications port on the UPS. The UPS can now c[...]
-
Página 14
Page 14 - 34007532EN/AA 2. Installation 2.6 Connections Check that the indications on the rating plate on the back of the UPS correspond to your AC-power system and to the actual electrical consumption of all the equipment to be connected to the UPS. 1 - Remove the power cord supplying the equipment to be protected. 2 - Pulsar EX treme 2200C : conn[...]
-
Página 15
34007532EN/AA - Page 15 The protected equipment connected to the UPS can be energised, whether AC input power is available or not. 3. Operation 3.1 Start-up Caution : the AC input power source must be present when energising for the first time. Press the ON / OFF button 16 . The buzzer beeps and all the LEDs go ON. The buzzer beeps twice, then: ◗[...]
-
Página 16
Page 16 - 34007532EN/AA 3. Operation 3.3 Operation on battery power (following failur e of AC input power) Transfer to battery power The AC-power source is outside tolerances, LED 17 is ON, the buzzer beeps three times. The equipment connected to the UPS is supplied by the battery. Threshold for the low-battery warning The low-battery warning thres[...]
-
Página 17
34007532EN/AA - Page 17 3. Operation 3.4 Personalisation (optional) Function Personalisable function Automatic start Cold start (battery power) Forced shutdown Sleep mode UPS ON / OFF via software Default setting Enabled Enabled Enabled Disabled Enabled Personalisation parameters can be set and modified using the UPS Driver software installed on a [...]
-
Página 18
Page 18 - 34007532EN/AA 3. Operation Personalisable function Rated UPS voltage Frequency mode Rated UPS frequency UPS tolerance for AC-power source frequency Overload alarm threshold UPS restart following short-circuit Default setting 230 V Autoselect F = 50 Hz F ± 5% 1 10% Disabled Options 200 V - 208 V - 220 V - 240 V - 250 V Converter 60 Hz F ?[...]
-
Página 19
34007532EN/AA - Page 19 3. Operation 3.6 UPS remote power of f Pulsar EX treme C is equipped with a remote power off function (RPO) that can cut power to all the devices connected to the UPS using a remote user-operated contact. The function is implemented by opening a contact connected to the two terminals of connector 12 on the back of the UPS. I[...]
-
Página 20
Page 20 - 34007532EN/AA 4. Maintenance 4.1 T roubleshooting If any of LEDs 25 , 26 or 27 flash, there is a operating anomaly or an alarm. If a LED flashes, the bargraph data is no longer displayed. Indication LED 27 flashes and the buzzer beeps. LED 25 flashes and the buzzer beeps. LED 25 flashes and the buzzer emits a long beep once per hour . The[...]
-
Página 21
34007532EN/AA - Page 21 4. Maintenance Indication The outlets are not supplied with power , even though button 16 is ON (version 3200C only). LED 26 flashes and the buzzer sounds continuously . Signification One of the protection circuit breakers 6 for the outlets on the back of the UPS is open. UPS electronics have detected a UPS fault. Depending [...]
-
Página 22
Page 22 - 34007532EN/AA 4.2 Replacement of the battery module 4. Maintenance Safety rules: Batteries constitute a danger (electrical shock, burns). The short-circuit current may be very high. Precautions must be taken for all handling: ◗ remove all watches, rings, bracelets and any other metal objects; ◗ use tools with insulated handles. Remova[...]
-
Página 23
34007532EN/AA - Page 23 4. Maintenance E - Remove the screws for the battery cover. F - Remove the cover. Reinstallation of the battery module Carry out the above operation in reverse order. ◗ To maintain an identical level of performance and safety, use a battery module identical to that previously mounted in the UPS. ◗ Press the two parts of [...]
-
Página 24
Page 24 - 34007532EN/AA 5. Environment This product has been designed to respect the environment: It does not contain CFCs or HCFCs. UPS recycling at the end of service life: MGE UPS SYSTEMS undertakes to recycle, by certified companies and in compliance with all applicable regulations, all UPS products recovered at the end of their service life (c[...]
-
Página 25
34007532EN/AA - Page 25 6. Appendices 6.1 T echnical characteristics Rating AC input ◗ V oltage ◗ Frequency ◗ Power factor Output ◗ V oltage ◗ Frequency ◗ Harmonic distortion ◗ Overload capacity Battery Environment ◗ Noise level ◗ Operating temperature ◗ Relative humidity Standards and certification ◗ Safety ◗ Performance ?[...]
-
Página 26
Page 26 - 34007532EN/AA 6. Appendices 6.2 Glossary Authorised voltage range for Upper and lower voltage thresholds within which the UPS can operate on the automatic transfer to bypass if fault or bypass in the event of a UPS fault or overload. overload Automatic bypass Automatic switch controlled by the UPS, used to connect the equipment directly t[...]
-
Página 27
34007532EN/AA - Page 27 6. Appendices 6.3 Index A Remote power off ........................................................... 19 Automatic bypass ................................................... 9-18-20 Automatic start ............................................................... 17 B Bargraph .................................................[...]
-
Página 28
Page 28 - 34007532EN/AA[...]