Outback Power Systems GFX1424E manual
- Consulta online o descarga el manual de instrucciones
- 40 páginas
- 0.85 mb
Ir a la página of
manuales de instrucciones parecidos
-
Battery Charger
Outback Power Systems VFX3024E
59 páginas 2.16 mb -
Battery Charger
Outback Power Systems GVFX
32 páginas 0.62 mb -
Battery Charger
Outback Power Systems FX2024ET
59 páginas 2.16 mb -
Battery Charger
Outback Power Systems GFX1548
40 páginas 1.29 mb -
Battery Charger
Outback Power Systems GTFX2524
2 páginas 0.18 mb -
Battery Charger
Outback Power Systems GVFX3648
2 páginas 0.18 mb -
Battery Charger
Outback Power Systems GFX1312
40 páginas 1.29 mb -
Battery Charger
Outback Power Systems VFX2612E
59 páginas 2.16 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Outback Power Systems GFX1424E. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Outback Power Systems GFX1424E o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Outback Power Systems GFX1424E se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Outback Power Systems GFX1424E, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Outback Power Systems GFX1424E debe contener:
- información acerca de las especificaciones técnicas del dispositivo Outback Power Systems GFX1424E
- nombre de fabricante y año de fabricación del dispositivo Outback Power Systems GFX1424E
- condiciones de uso, configuración y mantenimiento del dispositivo Outback Power Systems GFX1424E
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Outback Power Systems GFX1424E no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Outback Power Systems GFX1424E y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Outback Power Systems en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Outback Power Systems GFX1424E, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Outback Power Systems GFX1424E, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Outback Power Systems GFX1424E. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
International Series GFX Inverter/Charger GFX1312E GFX1424E GFX1448E Installation Manual[...]
-
Página 2
About OutBack Power Technologies OutBack Power Technologies is a leader in advanced energy conv ersion technology. Our products include true sine wave inverter/chargers, maximum power point tracking charge controllers, system communication components, as well as breaker panels , breakers, accessories, and assembled systems. Contact Information Tele[...]
-
Página 3
900-0111-01-00 Rev A 1 Important Safety Instructions READ AND SAVE THESE INSTRUCTIONS! This manual contains important safety instructions for the International Series GFX inverters. Read all instructions and cautionary markings on the inverter and on any acce ssories or additional equipment included in the installation. Failure to adhere to these i[...]
-
Página 4
Important Safety Instructions 2 900-0111-01-00 Rev A Definitions The following is a list of initia ls, terms, and definitions used in conjunction with this product. Table 1 Terms and Definitions Term Definition AC Alternating Current; ref ers to voltage produc ed by the inverte r, util ity grid, or generator AGS Automatic Generator Start AUX Invert[...]
-
Página 5
Important Safety Instructions 900-0111-01-00 Rev A 3 CAUTION: Equipment Damage Only use components or accessories recommen ded or sold by OutBack Power Technologies or its authorized agents. IMPORTANT: Do not attempt to install this equipment if it appears to be damaged in any way. See the Troubleshooting Section fo r instructions on how to return [...]
-
Página 6
Important Safety Instructions 4 900-0111-01-00 Rev A CAUTION: Equipment Damage When connecting cables from the inverter to the battery terminals, ensure the proper polarity is observed. Connecting the cables incorre ctly can damage or destroy the equipment and void the product warranty. Thoroughly inspect the equipment prior to energizing. [...]
-
Página 7
Important Safety Instructions 900-0111-01-00 Rev A 5 Regulatory Listings The International Series GFX Inverter/Charg er is CE compliant for off-grid use. Recycling Information IMPORTANT: Recycle Electronics and Batteries Batteries are considered hazardous wast e and must be recycled according to local jurisdiction. Inverters a nd other electronics [...]
-
Página 8
Important Safety Instructions 6 900-0111-01-00 Rev A EuroRecycle.net The following website provides general informatio n abou t recycling in Europe. It also provides a list of companies and organizations that provid e recycling information or assistance. Web site: http://euro.recycle.net E-mail: http://euro.recycle.n et/cgi-bin/feedback1.cgi?w=27 ([...]
-
Página 9
900-0111-01-00 Rev A 7 Table of Contents Important Safety Instructions ........................................................................ 1 Audience.................................................................................................................................................................................. 1 Symbols Used ..[...]
-
Página 10
Table of Contents 8 900-0111-01-00 Rev A List of Tables Table 1 Terms and Def initions ......................................................................................... ............................ 2 Table 2 Components and A ccessories .................................................................................................... 1 0 T[...]
-
Página 11
900-0111-01-00 Rev A 9 Introduction Welcome to OutBack Power Technologies Thank you for purchasing the OutBack International Se ries GFX Inverter/Charger. This product offers a complete power conversion system between batteries and AC power. It can provide backup power or complete off-grid service. Battery-to-AC inverting which delivers 230 Vac[...]
-
Página 12
Introduction 10 900-0111-01-00 Rev A Each model inverter has a single phase output marked with this symbol: Each inverter puts out a sine wave waveform marked with this symbol: Components and Accessories Table 2 Components and Accessories Installed Components Included in Box Battery Termin al Cover, red GFX Series Installation Manual (this book[...]
-
Página 13
900-0111-01-00 Rev A 11 Planning Applications The International Series GFX inverters are intend ed for on-grid, off-grid, and grid-interactive applications. These models are de signed to use a battery bank to store energy. They can work in conjunction with photovoltaic (PV) panels to harvest solar energy, as well as wind turbines and other renewabl[...]
-
Página 14
Planning 12 900-0111-01-00 Rev A Renewable Energy The inverter cannot connect directly to PV, wind, or other renewable sources. The batteries are the inverter’s primary source of power. However, if th ese sources are used to charge the batteries, the inverter can use their energy by drawing it from the batteries. The renewable source is always tr[...]
-
Página 15
Planning 900-0111-01-00 Rev A 13 A generator should be sized to provide enough po wer for all the loads and the battery charging. Available generator pow er may be limited by ratings for circuit break ers and/or generator co nnectors. The generator must be able to provid e current to all inverters on a give n phase or leg. Minimum generator[...]
-
Página 16
Planning 14 900-0111-01-00 Rev A NOTES:[...]
-
Página 17
900-0111-01-00 Rev A 15 Installation Location and Environmental Requirements The International Series GFX inverters can be loca ted outdoors, but OutBack still recommends that they be protected from the environment. If protected from the environment, the inverter can mount in any position or orientation. If exposed to the environment, it cannot[...]
-
Página 18
Installation 16 900-0111-01-00 Rev A Tools Required Wire cutters/strippers Torque wrenches Assorted insulated screwdriv ers DVM or Voltmeter Mounting It is easier for two people to install the GFX inverter due to its weight. The unit must be secured with approp riate fasteners to a sturdy mounting surface capable of supporti[...]
-
Página 19
Installation 900-0111-01-00 Rev A 17 Terminals and Ports Figure 5 Terminals, Ports, and Features WARNING: Shock Hazard The inverter’s AC output is defaulted to ON from the factory. It wi ll deliver 230 Vac as soon as DC power is connected. INVERTER ON/OFF : R eceives wires for a manual on/off switch to control the inverter. The JP1 jumper alongsi[...]
-
Página 20
Installation 18 900-0111-01-00 Rev A Grounding WARNING: Shock Hazard The unit must be connected to a grounded, pe rmanent wiring system. If a bond is made between neutral and ground make sure only on e bond is present in the AC system at any time. Some codes require the bond to be made at the main panel only. WARNING: Shock Hazard For all installat[...]
-
Página 21
Installation 900-0111-01-00 Rev A 19 DC Wiring CAUTION: Equipment Damage Never reverse the polarity of the battery cables. Always use correct polarity. CAUTION: Fire Hazard Always install a breaker, fuse, or protec tive device to protect the DC system. Table 4 DC Conductor Size and Torque Requirements Inverter Nominal DC Amps (Derated 125%) Conduct[...]
-
Página 22
Installation 20 900-0111-01-00 Rev A Mounting Surface M8 x 1.25 Stud Lock Washer Battery Cable Lug 13 mm Nut Flat Washer Insulator Figure 9 Required Order of Battery Cable Hard ware CAUTION: Fire Hazard Never install extra washers or hardware between the mounting surface and the battery cable lug. The decreased surface area can build up heat. Insta[...]
-
Página 23
Installation 900-0111-01-00 Rev A 21 AC Wiring Table 5 AC Conductor Size and Torque Requirements Conductor Size Recommend ation Torque Requirements Minimum 6 mm (#10 AWG or 0.008 in) 4.0 Nm (35 in-lbs) Figure 10 AC Terminals All system wiring must comply with national and local codes and regulations. Multiple AC Sources Figure 11 Multiple AC [...]
-
Página 24
Installation 22 900-0111-01-00 Rev A Accessory Wiring Figure 12 Accessory Connections Figure 13 ON/OFF Jumper and Connections RTS cable (RJ11, 4-conductor, telephone) MATE cable (RJ45, 8-conductor, CAT5 non-crossover) MATE/HUB port RTS port T he AC Wiring Compartment Board has port s for both the Remote Temper ature Sensor (RTS) and the system disp[...]
-
Página 25
Installation 900-0111-01-00 Rev A 23 AUX Wiring The AUX+ and AUX– terminals are a switched 12 Vdc supply. The AUX can resp ond to many criteria and control many functions. These include cooling fans, vent fans, load diver sion, fault alarms, and automatic generator control. The AUX output can also be controlled extern ally through the system disp[...]
-
Página 26
Installation 24 900-0111-01-00 Rev A Automatic Generator Start (AGS) The AUX terminals can be used to pe rform “two-wire” generator start. A two-wire-start generator is the simplest type, where most of the circuits are au tomated. It usually has a single switch with two positions that is turned ON to start, OFF to stop. Either the system displa[...]
-
Página 27
Installation 900-0111-01-00 Rev A 25 A “three-wire-start” generator has two or more starting circuits. It usually has a separate switch or position for cranking the generator. The AUX terminals cannot control this ty pe of generator without using a three-wire to two-wire conversion kit. Atkinson Electronics (http://atkinsonelectronics.com) make[...]
-
Página 28
Installation 26 900-0111-01-00 Rev A Single-Inverter Installations When installing an inverter AC system , the following rules must be observed. All wiring and input breakers must be sized for 30 Aac or less. All output breakers must be sized appropriately for loads and inverter wattage. Figure 18 Single-Inverter Wiring[...]
-
Página 29
Installation 900-0111-01-00 Rev A 27 Multiple-Inverter Installations (Stacking) Installing multiple inverters in a si ngle AC system allows larger loads than a single inverter can handle. This requires stacking. Stacking inverters does not re fer to physically placing one on top of another. It refers to how they are wired within the system and then[...]
-
Página 30
Installation 28 900-0111-01-00 Rev A Parallel Stacking (Dual-Stack and Larger) In parallel stacking, two or more inverters are st acked to create a single, common 230 Vac bus. All inverters share a common input (AC so urce) and run loads on a common output. Up to ten inverters may be insta lled in a parallel arrangement. Th e example on thi[...]
-
Página 31
Installation 900-0111-01-00 Rev A 29 Figure 21 Parallel Wiring (Four Inverters)[...]
-
Página 32
Installation 30 900-0111-01-00 Rev A Three-Phase Stacking In three-phase stacking, inverters are stacked to create three separate 230 Vac output legs in a wye configuration. The output of each inverter i s 120° out of phase from the others. Any two outputs p roduce 400 Vac between them. The outputs can be used to power three-phase loads whe n [...]
-
Página 33
Installation 900-0111-01-00 Rev A 31 Figure 23 Three-Phase Wiring (Three Inverters)[...]
-
Página 34
Installation 32 900-0111-01-00 Rev A Functional Test Once the mounting, wiring, and other installa tion steps are completed, proceed to the International Series GFX Operator’s Manual . The Operator’s Manual has steps for powering up and performing a functional test on the inverter system, as well as powering down and adding new devices to an ex[...]
-
Página 35
Installation 900-0111-01-00 Rev A 33 NOTES:[...]
-
Página 36
Installation 34 900-0111-01-00 Rev A NOTES:[...]
-
Página 37
900-0111-01-00 Rev A 35 Index A AC Conduit Plate ............................................................... 10 AC Terminals....................................................................... 17 AC Wiri ng ............................................................................. 21 AGS ...................................................[...]
-
Página 38
Index 36 900-0111-01-00 Rev A Regulatory ............................................................................. 5 Remote System Display ..............................................2, 12 Remote Temperatur e Sensor (RTS) ........... 2, 10, 17, 22 Renewable Energy ............................................................ 12 S Safety.......[...]
-
Página 39
Index 900-0111-01-00 Rev A 37[...]
-
Página 40
North America 19009 62nd Avenue NE Arlington, WA 98223 USA 1.360.435. 6030 European Office: Barcelona, Spain 34.93.654. 9568 900-0111-01- 00 Rev A[...]