Agilent Technologies E3630A manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 27 pages
- 0.72 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Power Supply
Agilent Technologies E3616A
47 pages 1.65 mb -
Power Supply
Agilent Technologies 665xA
70 pages 0.55 mb -
Power Supply
Agilent Technologies E3617A
47 pages 1.65 mb -
Power Supply
Agilent Technologies 6623A
109 pages 0.8 mb -
Power Supply
Agilent Technologies 603xA
134 pages 0.7 mb -
Power Supply
Agilent Technologies 87421A
8 pages 0.49 mb -
Power Supply
Agilent Technologies 6010a
126 pages 2 mb -
Power Supply
Agilent Technologies 66332A
83 pages 1.68 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Agilent Technologies E3630A. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Agilent Technologies E3630A ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Agilent Technologies E3630A décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Agilent Technologies E3630A devrait contenir:
- informations sur les caractéristiques techniques du dispositif Agilent Technologies E3630A
- nom du fabricant et année de fabrication Agilent Technologies E3630A
- instructions d'utilisation, de réglage et d’entretien de l'équipement Agilent Technologies E3630A
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Agilent Technologies E3630A ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Agilent Technologies E3630A et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Agilent Technologies en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Agilent Technologies E3630A, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Agilent Technologies E3630A, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Agilent Technologies E3630A. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
DUA L OUTPUT POWER SUPP L Y A gi lent MO DEL E3630A OPERA TING A ND SER VICE MA NUAL FOR INSTRUMENTS WITH SERIA L NUMBERS KR85014528 A ND A BOVE For instruments with Serial Numbers above KR85014528, a change page may be included . Manual Part No. 5959-5329 I April 2000 Edition 7[...]
-
Page 2
1-2 SA FETY SUMMARY The following general safety prec autions must be observed during all phases of oper ation, service, and repair of this instrumen t. Failure to com ply with thes e precautions or with spec ific warnings elsewhere in this manual v iolates safety standards of des ign , manufacture, and intended use of the inst rument. A gilent T e[...]
-
Page 3
1-3 T able of Contents SA FETY SUMM A RY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 GENERA L INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 INTRODUCTIO N . . . . . . . . . . . . . . [...]
-
Page 4
1-4 GENERAL INFORMATION IN TRO DU CTI ON This section contains general i nformation concerning the E3630A triple output pow er supply. Included are safety con- siderations, safety and EM C requirements, inst rument and manual ident ification, option and ac cessory inf ormation, instrument descript ion, and specifications. SAFETY CONSIDER A TI ONS T[...]
-
Page 5
1-5 mode. In this mode the voltage of the negative output can be set lower than that of the positive output. T he tracking ratio control allows the negative supply 's output to be set to any va lue between a max imum that is within ±5% of the positive supply 's output and a minimum that is less than 0.5 volts. Once a ratio is estab lishe[...]
-
Page 6
1-6 INST A LLA TION INITIA L INSPE CTION Before s hipment, this instrument w as inspected and found t o be free of mecha nical and e lectrical defects. As soon as the instrument is unpacked, inspect for any dam age that may have occurred in t ransit. Sav e all packing m aterials until the inspection is com pleted. If damage is found, a c laim shoul[...]
-
Page 7
1-7 Before applying power to the supply , check the label on the heat sink t o mak e certain that the supply's line voltage option agrees wit h the line voltage to be used . If the opti on does not correspond to your line voltage, refer to paragraph "LI NE VOL T AG E OPTION CONVERSIO N" in the service section before applying power. T[...]
-
Page 8
1-8 Figure 3. Current Limit Characteristic of the 6V Supply this region. If the line voltage is maintained in the up per end of the input voltage range, howev er , the supply pr obably w ill operate within its specifications Connecting Load Each load should be connected t o the power supp ly output terminals using separate pairs of connect ing wire[...]
-
Page 9
1-9 Figure 4. Rev ers e Cur rent L oading S olution[...]
-
Page 10
A-1 SERVICE INFORMA TION Figure A- 1. Blo ck Di agram PRINCIPLES OF OP ERA TION (Blo ck Diagr am Over view) This sect ion presents t he principles of operation of t he E3630A Triple Out put Power S upply . T hroughout this discus- sion, refer to bot h the block d iagram of Figure A-1 and the schematic diagrams at the rear of the manual. The t wo pr[...]
-
Page 11
A-2 put is enclosed by a heavy line in Figure 3 of the operating section. If the operating point reaches the diagonal current limit line, a dec rease in load r esistance moves the op erating point down the line, reducing the out put voltage and current . Current foldback is controlled by a secon d operational ampli- fier (current comparison amplifi[...]
-
Page 12
A-3 Operation V erification T ests The followin g tests assure that the power suppl y is per- formin g properl y . The y do not, however , check all the speci- fied parameters tested in the complete performance test described below . Proceed as follows: a. Perform turn-on checkout procedure g iven in pa g e 1-7. b. Perform the load re g ulation per[...]
-
Page 13
A-4 Output Current Measurement. For accurate output current measurements, a current sampling resistor should be inserted between the load and the output of the supply . T o simplify grounding problems, one end of this sampli ng resistor shoul d be connected to the same output terminal of the supply which w ill be shorted to ground. An accurate vol [...]
-
Page 14
A-5 Current Limit k. Disconnect all loads from the suppl y . l. Connect the test setup shown in Fi g ure A-5 to the +20- volt output. Substitute a short for R L and leave the load circuit switch open. m. Set the volta g e of the ± 20V supplies to 20 volts. n. Close the load switch and determine the current flow throu g h the current samplin g resi[...]
-
Page 15
A-6 Peak-to-Peak Measurement The peak-t o-peak measurem ent is particularly i mportant for applications where noise spikes could be detrimental to a sensitive load, such as logic circuitry. T o measure the ripple and noise of the peak-to-peak value on each output supply output: a. Connect the test equipment across the output of the +20V supply as s[...]
-
Page 16
A-7 St ability (Drift) Definiti on: The change in output voltage (dc to 20 Hz) for the first 8 hours following a 30-minute w arm-up period with con- stant input line voltage, constant load resistance and constant ambient tem perature. T o me asure the stability : a. Connect the test equipmen t across the output of the +20V supply as shown in Figure[...]
-
Page 17
A-8 T a ble A -3 . Ini tial T robles hooting Procedu re STE P ACTION RESPONS E NEXT A CT ION 1 Check output voltage of +20V supply . a. Normal b. Zero volts c. Output voltage low er or higher than rat ing a. Proceed to step (2) . b. Check ac line fuse (F1). If blow n, proceed to "Open F use Troubleshooting" paragraph. If not blown, check [...]
-
Page 18
A-9 Low outpu t voltage (lower t han rating) 1. Measure voltage at t he base of Q5. 2. Eliminate current limit circuit as a source of trouble by disc onnecting anode of CR1 1. 3. Measure voltage at pin 3 of U6. a. Measured voltage is less than 0 vol t. b. Measures voltage is more than 0 vol t. a. Out put voltage increas es. b. Out put voltage remai[...]
-
Page 19
A-10 T able A-7. +6 V Su pply T r oubl eshooti ng SYMPTOM STEP - A CTION RE SPONSE P ROBA BLE CA USE The +20V supply must operat e properly before tr oubleshooting the -20V supply . High output voltage (higher than rat ing) 1. Atte mpt to turn of f Q1 by shorting emitt er-to-base of Q1. 2. Measure voltage at base of Q4. a. Outpu t voltage remains h[...]
-
Page 20
A-11 A DJ USTMENT A ND CA LIBR A TION Current Limit Adjustme nt +6V S upply. T o adjust the current limit circuit in t he +6V sup- ply , proceed as follows: a. Check the setting of the current limit by performing steps (p) and (q) on page A-5. (Be sure to set the output voltage to 6 volts.) If reducing the load resistance permits the cur- rent to e[...]
-
Page 21
A-12 REPL A C EA BLE P A RT S IN TRO DU CTI ON This section contains informat ion for ordering replacement parts. T able A-12 lists parts by reference designators and pro- vides the following information: a. Reference designators. Refer to T able A-10. b. Agilent T echnologies Part Number . c. T otal quantity us ed in that as sembly. d. Description[...]
-
Page 22
REFERE NCE DESIGNATION PART NUMBER Q'T Y DESCRIPTION MFR. CODE MFR. P/N [...]
-
Page 23
REFERE NCE DESIGNATION PART NUMBER Q'TY DESCRIPTION MFR. CODE MFR. P/N )"*'#?[...]
-
Page 24
REFERE NCE DESIGNATION PART NUMBER Q'TY DESCRIPTION MFR. CODE MFR. P/N &*'&?[...]
-
Page 25
REFERE NCE DESIGNATION PART NUMBER Q'TY DESCRIPTION MFR. CODE MFR. P/N , !!& ![...]
-
Page 26
CERTIFICATION Agilent T ec hnologies c ertifies that this pr oduct m et its published s pecificat ions at time of sh ipmen t fro m t he fa ctor y . Agilent T ech nologies furt her cert ifies that its ca libration m easurem ents are trac eable t o the United St ate s Nat ional Ins titute of Stan- dards and T echnolo gy (form erly National Bure au of[...]
-
Page 27
DECLA RA TION O F CONFORMITY accordi ng to ISO/IEC Guid e 22 and EN 4 5014 Manufactu rer’s Name: Agilent Techno logies, In c. Manufactu rer’s Address: 3 45-15, Kasa n-dong, Kum chon-ku, Seoul 15 3-023 Korea declares, that the produc ts Product Na me: DC Power Supply Model Numbers : E3630A Product Opt ions: Al l Options conforms to the follow in[...]