American Dynamics AD1645 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 32 pages
- 0.63 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Receiver
American Dynamics AD1645
32 pages 0.63 mb -
Receiver
American Dynamics AD1689B
28 pages 0.6 mb -
Receiver
American Dynamics AD1641M-2
2 pages 0.11 mb -
Receiver
American Dynamics AD1686B
28 pages 0.27 mb -
Receiver
American Dynamics AD1684B
28 pages 0.28 mb -
Receiver
American Dynamics AD1646
44 pages 0.37 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation American Dynamics AD1645. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel American Dynamics AD1645 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation American Dynamics AD1645 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation American Dynamics AD1645 devrait contenir:
- informations sur les caractéristiques techniques du dispositif American Dynamics AD1645
- nom du fabricant et année de fabrication American Dynamics AD1645
- instructions d'utilisation, de réglage et d’entretien de l'équipement American Dynamics AD1645
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage American Dynamics AD1645 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles American Dynamics AD1645 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service American Dynamics en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées American Dynamics AD1645, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif American Dynamics AD1645, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation American Dynamics AD1645. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Model 1645 Receiver Installation and Operating Instructions This manual describes the installation and operating procedures for the American Dynamics model 1645 Receiver. Receivers are designed as the remote control device for operation of a motorized pan/tilt unit and a motorized lens unit. Since camera sites are often a great distance from the op[...]
-
Page 2
The software/firmware furnished with this equipment is confidential to and is copyrighted by AMERICAN DYNAMICS. It is not to be copied or disclosed in any manner without the express written consent of AMERICAN DYNAMICS. The software/firmware is furnished to the purchaser under a license for use on a single system, and remains the property of Americ[...]
-
Page 3
QA303C This product generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the spe[...]
-
Page 4
T able of Contents Description............................................................................ 1 Features ................................................................................. 1 Installation ............................................................................ 2 Setup ..................................................[...]
-
Page 5
DESCRIPTION The 1645 Receiver is a single channel receiver for control of motorized pan/tilt and lens units used with Matrix Switching Systems. The 1645 is used with the American Dynamics 1237VS or Videor Technical VPT-21 Pan/Tilt unit to control the pan, tilt, zoom, focus, and iris of a single camera, and to control auxiliary functions at a camera[...]
-
Page 6
INSTALLATION This installation should be made by a qualified service person and should conform to all local codes. Safeguards must be taken to avoid unintentional operation by employees and personnel working about the premises, by falling objects, by customers, by building vibration, and by similar causes. Preparation Several user configuration swi[...]
-
Page 7
SETUP Camera Number Assignment For individual control of camera Pan/Tilt actions by the Matrix Switching System, a camera number must be associated with each Receiver. A 10-position DIP switch labeled “CAMERA ID” is used to associate a particular camera number with the Receiver. This switch is located on the side panel of the 1645 Receiver (see[...]
-
Page 8
SETUP 4 Code Terminal Connector Auxiliary and Preposition Connector CAMERA ID Pan/Tilt and Lens Connector POWER LED CODE LED LENS ADJ Power cord Control Code Receiver Module PCB J6 on Main PCB R3 T1 C44 C43 J7 S5 J6 on Receiver Module PCB J1 S2 S1 K1 K2 S4 BLK WHT S3 OFF ON 1 8 U12 U19 U18 Figure 4 - 1645M (Control Code Series) Connector and Switch[...]
-
Page 9
RS-232 Receiver (1645S) Setup In order to receive RS-232 code, the S1 and S2 DIP switches on the RS-232 Receiver Module must be set to the following positions. See Figure 5 below for location of these DIP switches on the 1645S Receiver Module PCB. DIP Sw. 1 2 3 4 5 6 7 8 S1 On On Off Off Off Off Off Off S2 --- Reserved for Future Use --- When the 1[...]
-
Page 10
CONNECTIONS Code Line Connections for Control Code (model 1645M) The Code Terminal Connector, J1, is a 3-position terminal connector located on the side of the unit (see Figure 4, page 4). The terminal is marked W (white code), S (shield), and B (black code). A mating screw-terminal plug is provided for this connector. Use 18 AWG, shielded, 2-wire [...]
-
Page 11
Code Line Connections for RS-232 (1645S Series) Matrix Switching Systems, RS-232 keyboards, modems, and other RS-232 compatible devices, are connected to the RS-232 connector of the 1645S. The RS-232 Terminal Connector, J3, is a 6-pin connector located on the side of the 1645S (see Figure 5, page 5). A mating screw-terminal plug is provided for thi[...]
-
Page 12
Pan/Tilt and Lens Cable The connection to a Pan/Tilt and a motorized Lens is with a 12-pin connector. This connector (J6) is located on the side of the unit, near the Camera ID DIP switch (see Figures 4 and 5, pages 4 and 5). Table 5 lists the pin designations from the Receiver to the Pan/Tilt and the Lens units, and provides space for the installe[...]
-
Page 13
Auxiliary and Preposition Cable The connection of auxiliary equipment and preposition servos is with a 14-pin connector. This connector (J7) is located on the side, near the Code Line Connector (see Figures 4 and 5, pages 4 and 5). Table 8 lists the pin designations from the Receiver to the auxiliaries and the pre-position servos and provides space[...]
-
Page 14
OPERATION Powering Up The 1645 Receiver is supplied for the following power sources: 1645M,1645S 120VAC, 50/60Hz 1645MX,1645SX 230VAC, 50/60Hz The 1645 Receivers are shipped with a pendant cord and wall plug for use with an electrical outlet. Plug the cord to the required voltage source according to the model. The green LED labeled “POWER” on t[...]
-
Page 15
Appendix[...]
-
Page 16
[...]
-
Page 17
Camera Identification DIP Switch Settings 0 = Off 1 = On 1645M models, set switch positions 7-10 Off; 1645S models, set the switches in the shaded section of the table Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 1 0 0 0000 2 1 0 0000 3 0 1 0000 4 1 1 0000 5 0 0 1000 6 1 0 1000 7 0 1 1000 8 1 1 1000 9 0 0 0100 1 0 1 0 0100 1 1 0 1 01[...]
-
Page 18
Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 1 2 9 00 0000 1 3 0 10 0000 1 3 1 01 0000 1 3 2 11 0000 1 3 3 00 1000 1 3 4 10 1000 1 3 5 01 1000 1 3 6 11 1000 1 3 7 00 0100 1 3 8 10 0100 1 3 9 01 0100 1 4 0 11 0100 1 4 1 00 1100 1 4 2 10 1100 1 4 3 01 1100 1 4 4 11 1100 1 4 5 00 0010 1 4 6 10 0010 1 4 7 01 0010 1 4 8 11 0010 1 4 9 00 1[...]
-
Page 19
Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 257 0 0 0 0 0 0 258 1 0 0 0 0 0 259 0 1 0 0 0 0 260 1 1 0 0 0 0 261 0 0 1 0 0 0 262 1 0 1 0 0 0 263 0 1 1 0 0 0 264 1 1 1 0 0 0 265 0 0 0 1 0 0 266 1 0 0 1 0 0 267 0 1 0 1 0 0 268 1 1 0 1 0 0 269 0 0 1 1 0 0 270 1 0 1 1 0 0 271 0 1 1 1 0 0 272 1 1 1 1 0 0 273 0 0 0 0 1 0 274 1 0 0 0 1 0 275 0 1 0 0[...]
-
Page 20
Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 385 0 0 0 0 0 0 386 1 0 0 0 0 0 387 0 1 0 0 0 0 388 1 1 0 0 0 0 389 0 0 1 0 0 0 390 1 0 1 0 0 0 391 0 1 1 0 0 0 392 1 1 1 0 0 0 393 0 0 0 1 0 0 394 1 0 0 1 0 0 395 0 1 0 1 0 0 396 1 1 0 1 0 0 397 0 0 1 1 0 0 398 1 0 1 1 0 0 399 0 1 1 1 0 0 400 1 1 1 1 0 0 401 0 0 0 0 1 0 402 1 0 0 0 1 0 40[...]
-
Page 21
Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 5 1 3 0 0000 0 5 1 4 1 0000 0 5 1 5 0 1000 0 5 1 6 1 1000 0 5 1 7 0 0100 0 5 1 8 1 0100 0 5 1 9 0 1100 0 5 2 0 1 1100 0 5 2 1 0 0010 0 5 2 2 1 0010 0 5 2 3 0 1010 0 5 2 4 1 1010 0 5 2 5 0 0110 0 5 2 6 1 0110 0 5 2 7 0 1110 0 5 2 8 1 1110 0 5 2 9 0 0001 0 5 3 0 1 0001 0 5 3 1 0 1001 0 5 3 2[...]
-
Page 22
Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 641 0 0 0 0 0 0 642 1 0 0 0 0 0 643 0 1 0 0 0 0 644 1 1 0 0 0 0 645 0 0 1 0 0 0 646 1 0 1 0 0 0 647 0 1 1 0 0 0 648 1 1 1 0 0 0 649 0 0 0 1 0 0 650 1 0 0 1 0 0 651 0 1 0 1 0 0 652 1 1 0 1 0 0 653 0 0 1 1 0 0 654 1 0 1 1 0 0 655 0 1 1 1 0 0 656 1 1 1 1 0 0 657 0 0 0 0 1 0 658 1 0 0 0 1 0 65[...]
-
Page 23
Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 769 0 0 0 0 0 0 770 1 0 0 0 0 0 771 0 1 0 0 0 0 772 1 1 0 0 0 0 773 0 0 1 0 0 0 774 1 0 1 0 0 0 775 0 1 1 0 0 0 776 1 1 1 0 0 0 777 0 0 0 1 0 0 778 1 0 0 1 0 0 779 0 1 0 1 0 0 780 1 1 0 1 0 0 781 0 0 1 1 0 0 782 1 0 1 1 0 0 783 0 1 1 1 0 0 784 1 1 1 1 0 0 785 0 0 0 0 1 0 786 1 0 0 0 1 0 78[...]
-
Page 24
Appendix Camera Switch Position Number 1 2 3 4 5 6 7 8 9 10 8 9 7 00000 0 8 9 8 10000 0 8 9 9 01000 0 9 0 0 11000 0 9 0 1 00100 0 9 0 2 10100 0 9 0 3 01100 0 9 0 4 11100 0 9 0 5 00010 0 9 0 6 10010 0 9 0 7 01010 0 9 0 8 11010 0 9 0 9 00110 0 9 1 0 10110 0 9 1 1 01110 0 9 1 2 11110 0 9 1 3 00001 0 9 1 4 10001 0 9 1 5 01001 0 9 1 6 11001 0 9 1 7 0010[...]
-
Page 25
TYPICAL SYSTEM CONNECTIONS 1645 to 1237VS Pan/Tilt 1237VS PAN/TILT 1645 RECEIVER 7-Pin 1237VS Connector 123456 7 FOCUS ZOOM IRIS SHIELD + 20 VDC TILT - 20 VDC PAN ALARM 1 ALARM 2 GND COMMON J6[...]
-
Page 26
TYPICAL SYSTEM CONNECTIONS 1645 to 1237VSP Pan/Tilt with Pre-position 1237VSP PAN/TILT AUX2 N/C AUX1 COM AUX1 N/O TILT POT SHIELD ZOOM POT FOCUS POT - REF PAN2 POT PAN1 POT + REF AUX1 N/C AUX2 N/O AUX2 COM J7 1645 RECEIVER 11-Pin 1237VSP Connector FOCUS ZOOM IRIS SHIELD + 20 VDC TILT - 20 VDC PAN ALARM 1 ALARM 2 GND COMMON J6 A BCDE FG H J K L M[...]
-
Page 27
TYPICAL SYSTEM CONNECTIONS 1996 Controller to 2091 Code Generator, to 1645M (Control Code) 1645M 2091 1996 ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B[...]
-
Page 28
TYPICAL SYSTEM CONNECTIONS 2150 Controller to 1645M (Control Code) MAXIMUM DISTANCE between 1645 and 2150 is 5000 Ft, using shielded, 18 AWG cable 2150 1645M BW S RS232 PORTS 123 KEYBOARDS 2345 CAMERAS ALARMS RELAY 120V 60Hz CODE BWS BWS BWS BWS MONITORS 12345 2468 1 0 1 2 1 4 1 6 1 8 2 0 2 2 2 4 2 6 2 8 3 0 3 2 13579 1 1 1 3 1 5 1 7 1 9 2 1 2 3[...]
-
Page 29
TYPICAL SYSTEM CONNECTIONS 1676 Keyboard to 1645S (RS-232 Connection) HP0047 TERMINAL BOX JJ0007 Cable BROWN (GRD) RED (RCD) GREEN (XMIT) 1645S 4 1676 TP8059 Wall Transformer T + T - R + R - CODE POWER AUX2 N/C AUX1 COM AUX1 N/O TILT POT SHIELD ZOOM POT FOCUS POT - REF PAN2 POT PAN1 POT + REF AUX1 N/C AUX2 N/O AUX2 COM MAXIMUM DISTANCE between 1645[...]
-
Page 30
TYPICAL SYSTEM CONNECTIONS 1983 Code Converter to 1645S (RS-232 Connection) 1983 PSK 120V 60Hz LINE RS232 PHONE 3 2 1 12 11 10 CODE I/O HP0047 TERMINAL BOX JJ0007 Cable BROWN (GRD) RED (XMIT) GREEN (RCD) 1645S T + T - R + R - CODE POWER AUX2 N/C AUX1 COM AUX1 N/O TILT POT SHIELD ZOOM POT FOCUS POT - REF PAN2 POT PAN1 POT + REF AUX1 N/C AUX2 N/O AUX[...]
-
Page 31
2091 TYPICAL SYSTEM CONNECTIONS 1996 Controller to 2091, to 1645S (RS-232 Connection) 1996 1645S ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S B W S[...]
-
Page 32
An American Dynamics Product Designed and built by Sensormatic CCTV Systems Division One Blue Hill Plaza Pearl River, New York, 10965 (914) 624-7600 Technical Support Center: 1-800-442-2225 FAX: 914-624-7685 8000-2894-01 OP1645B May 1994 Printed in USA SPECIFICATIONS Supply Voltage: 1645M,1645S 120VAC, 50/60 Hz 1645MX,1645SX 230VAC, 50/60 Hz Power:[...]