American Power Conversion AP7902 AP7911 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 26 pages
- 1.07 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Power Supply
American Power Conversion AP9555
16 pages 0.41 mb -
Power Supply
American Power Conversion RS 1500
2 pages 0.54 mb -
Power Supply
American Power Conversion SURTA1500XLJ
16 pages 0.61 mb -
Power Supply
American Power Conversion ES 700
2 pages 0.28 mb -
Power Supply
American Power Conversion SUOL2000UXI
16 pages 0.74 mb -
Power Supply
American Power Conversion AP7862J
24 pages 1 mb -
Power Supply
American Power Conversion 400
44 pages 0.26 mb -
Power Supply
American Power Conversion SL 300TFX
27 pages 0.73 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation American Power Conversion AP7902 AP7911. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel American Power Conversion AP7902 AP7911 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation American Power Conversion AP7902 AP7911 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation American Power Conversion AP7902 AP7911 devrait contenir:
- informations sur les caractéristiques techniques du dispositif American Power Conversion AP7902 AP7911
- nom du fabricant et année de fabrication American Power Conversion AP7902 AP7911
- instructions d'utilisation, de réglage et d’entretien de l'équipement American Power Conversion AP7902 AP7911
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage American Power Conversion AP7902 AP7911 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles American Power Conversion AP7902 AP7911 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service American Power Conversion en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées American Power Conversion AP7902 AP7911, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif American Power Conversion AP7902 AP7911, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation American Power Conversion AP7902 AP7911. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Switche d Rac k Power D istribution Un it AP7902 AP7911 Installation and Quick Start[...]
-
Page 2
[...]
-
Page 3
Contents Switched Ra ck PDU Insta llation and Quick Star t i Produ ct Descript ion and Inventor y . . . . . . . . . . . . . . . . . . . . . . 1 AP7902 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 AP7911 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Additional documen tation . . . . . [...]
-
Page 4
ii Switched Ra ck PDU Insta llation and Quick Star t How to Dow nload Firmwa re Updat es . . . . . . . . . . . . . . . . . . . 17 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 AP7902/AP7 911 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 8 Warrant y and Service . . . . . . . . . . . .[...]
-
Page 5
Switched Ra ck PDU Insta llation and Quick Star t 1 Pr oduct Description and Inventory AP7902 and AP79 1 1 are Switched Rack Powe r Distri bution Unit s (Rack PDUs) that dis tribute powe r to devices in the ra ck. The us er can tu rn on, turn off , or recycl e power bac k to the i ndividual ly contr olled outlet s. The Rack PDUs a lso have a sensor[...]
-
Page 6
Product Descripti on and In ventory 2 Switched Rack PDU Installation and Q uick Start Additiona l documentatio n The Rack PDU Us er’ s Gui de and the Rac k PDU Addendum a re avail able on the su pplied CD and on the APC W eb site: www .apc.co m . The User’ s Guide (.doceng usrg uide.pdf) cont ains additi onal informat ion about the fo llowin[...]
-
Page 7
Switched Ra ck PDU Insta llation and Quick Star t 3 How to Install the Rack PDU Installation guidelines • For a Ra ck PDU inst alled i n an enc losed co mmunicati ons rac k, the recommen ded maximum ambie nt tempera ture is 45° C ( 1 13º F). • Instal l the Rack PDU so that i t does not reduce th e air fl ow requir ed for saf e operati on of t[...]
-
Page 8
How to Install the Rack PDU 4 Switched Rack PDU Installation and Q uick Start Attach cor ds to the tray Attach a cord to t he tray by loop ing th e cord and s ecuring i t to the tray , using a wi re tie ( provided) . Cords fro m both banks o f outlet s may be secured to the bot tom tray , or you may a ttach an a dditional t ray (shown on the pr ece[...]
-
Page 9
How to Install the Rack PDU Switched Ra ck PDU Insta llation and Quick Star t 5 For a r ecessed placement : use four flat -head scr ews (provid ed) through t he last four ho les of ea ch bracket . 2. Insert caged nut s (provi ded with t he ra ck) on the vertic al mountin g rails above a number at the st art of two U-spa ces in your encl osure and b[...]
-
Page 10
6 Switched Rack PDU Installation and Q uick Start Operation Disp lay inte rfac e Link - Rx/Tx 10 / 100 Status Serial Port Rese t - W ar ning - OK - Overl oad B2 B1 TOT AL Amps Amps Amps Switch ed Rack PDU Line Indicator LED: In dicates normal (green), warning (yellow), and alarm (red) conditions for bank 1 (B1), [...]
-
Page 11
Switched Ra ck PDU Insta llation and Quick Star t 7 Quick Configuration Over v iew Y ou must configur e the fol lowing TCP/IP settin gs before the Rac k PDU can oper ate on a net work: • IP address o f the Rack PDU • Subnet mask • De fault g atewa y TCP/IP configuration methods Use one of the foll owing methods to define the TCP/IP settings: [...]
-
Page 12
Quick Configuration 8 Switched Rack PDU Installation and Quick Start APC Manageme nt Car d Wizar d Y ou can use the APC Management Card Wizard at a W indows ® 98, W indows NT ® 4.0, W indows 2000, or W indows XP computer to configure a Rack PD U. 1. Insert the APC Switche d Rack PDU Utility CD into a computer on your network. 2. Launch the W izar[...]
-
Page 13
Quick Configur ation Switched Ra ck PDU Insta llation and Quick Star t 9 BOOTP . Y ou can use an RFC951-compli ant BOOTP serve r to configu re the TCP/I P settings f or the Rack PDU. If the BOOTP serv er is pro perly configur ed, the Rac k PDU’ s default setting ( DHCP & BOOTP ) fo r BOOT Mode causes it t o discove r the BOOTP server . 1. Ent[...]
-
Page 14
Quick Configuratio n 10 Switched Ra ck PDU Insta llation and Quick Sta rt DHCP . Y ou can use a RFC2131/RFC2132-c ompliant DHCP s erver to configur e the TCP/I P settin gs for the Rack PDU. 1. The Rack PDU se nds a DHCP reque st that u ses the f ollowing to ident ify its elf: – V endor Class Identifi er (APC by default ) – Client Ide ntifier (b[...]
-
Page 15
Quick Configur ation Switched Ra ck PDU Insta llation and Quick Star t 11 Local access to the contr ol console Y ou can use a l ocal comput er to conn ect to th e Rack PDU to ac cess the control console. 1. Select a serial port at t he local computer , and dis able any s ervice which uses that por t. 2. Use the c onfig uration c able (940 -0144) to[...]
-
Page 16
Quick Configuratio n 12 Switched Ra ck PDU Insta llation and Quick Sta rt 3. U se T el net t o acc ess t he Ra ck PD U at its ne wl y assi gne d I P addr ess. F or e xampl e: telnet 156.205.14.141 4. Use apc for bot h user name and pas sword. 5. See “Contr ol consol e” on this page to f inish the configur ation. Contr ol console After yo u log [...]
-
Page 17
Switched Ra ck PDU Insta llation and Quick Star t 13 How to Access a Config ur ed Rack PDU Over v iew After t he Rack PDU is runn ing on yo ur network, you can use the interf aces summari zed he re to acce ss the uni t. W eb i nterf ace As your br owser , you can use Microsoft ® I nternet Ex plorer 5. 0 (and higher) or Netsca pe ® 4.0.8 (an d hig[...]
-
Page 18
How to Access a Configured Rack PDU 14 Switched Ra ck PDU Insta llation and Quick Sta rt T elnet/ SSH Y ou can acces s the cont rol consol e through T elne t or Secur e SHell (SSH), depe nding on whic h is enabl ed. An Administ rator c an enable these ac cess metho ds through the T e lnet/S SH option of the Network menu. By defa ult, T elnet is ena[...]
-
Page 19
How to Access a Configu red Rack PDU Switched Ra ck PDU Insta llation and Quick Star t 15 FT P / S C P Y ou can use FTP (ena bled by def ault) or Secure CoPy ( SCP) to tr ansfer new firmwar e to the Rack PDU, o r to acce ss a copy of th e Rack PDU’ s event l ogs. SCP provi des the hi gher secur ity of encr ypted data transmi ssion and i s automat[...]
-
Page 20
16 Switched Ra ck PDU Insta llation and Quick Sta rt How to Recover Fr om a Lost Passwor d Y ou can use a local computer , a computer that connects to t he Rack PDU or other device t hrough the serial p ort to ac cess the c ontrol c onsole. 1. Select a serial port at t he local computer , and dis able any s ervice that us es that po rt. 2. Connect [...]
-
Page 21
Switched Ra ck PDU Insta llation and Quick Star t 17 How to Download Firmwar e Updates Y ou can use a l ocal comput er that co nnects to the Rack PDU through th e serial port on t he front o f the unit. 1. Select a serial port at t he local computer , and dis able any s ervice that us es that po rt. 2. Use the c onfig uration c able (940 -0144) to [...]
-
Page 22
18 Switched Ra ck PDU Insta llation and Quick Sta rt Specifications AP79 02/AP7 911 Electrical AP790 2 AP791 1 Nominal input voltage 120 V 208 V Acceptable input voltage ± 10% Nominal inp ut voltage Maxi mum inpu t curr ent 24 A Input frequency 47 – 63 H z Cord l ength 12 ft Input connectors NEMA L5-30 plug NEMA L6-30 plug Output connectors S ix[...]
-
Page 23
Switched Ra ck PDU Insta llation and Quick Star t 19 W arranty and Service Limi ted w arr anty APC warrant s the Rack PDU to be free fr om defects in ma terials and workmanshi p for a per iod of two y ears fro m the date o f purchase . Its obligat ion under this warr anty is l imited to repairing or replaci ng, at it s own sole op tion, any s uch d[...]
-
Page 24
20 Switched Ra ck PDU Insta llation and Quick Sta rt Life-Support Policy General po licy American Power Conversion (APC) doe s not recommend th e use of any of its p rodu cts in the follow ing situat ions: • In lif e-support applica tions wher e failur e or malfun ction of t he APC product can be rea sonably exp ected to cause fai lure of t he li[...]
-
Page 25
Radio Fr equency Interfer ence USA — FCC This equi pment has be en teste d and found t o comply wit h the limits for a Class A d igital devic e, pursu ant to part 15 of the FCC Rules . These limit s are designed to pro vide reas onable pro tection against h armful interfe rence when the equi pment is ope rated in a commercial environme nt. This e[...]
-
Page 26
*990-1664* APC W orldwide Customer Support Customer support for this or any other AP C product is available at no char ge in any of the following ways: • V isit the APC W e b site to find answers to frequently asked questions (F AQs), to access documents in the APC Knowledge Base, and to submit customer support requests. – www .apc.com (Corpora[...]