APC SUA1000RMI1U Kit manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 18 pages
- N/A
Aller à la page of
Les manuels d’utilisation similaires
-
Uninterruptible power supply (
APC Back-UPS 500VA
8 pages -
Uninterruptible power supply (
APC MXA103
8 pages -
Uninterruptible power supply (
APC MGE Galaxy 3500 10kVA 400V with 2 Battery Modules
40 pages -
Uninterruptible power supply (
APC S20BLK
54 pages -
Uninterruptible power supply (
APC Smart-UPS X 1000VA Rack/Tower
6 pages -
Uninterruptible power supply (
APC ISXT216MD1RI
20 pages -
Uninterruptible power supply (
APC Smart-UPS RC 3000VA
21 pages -
Uninterruptible power supply (
APC BE400-GR-OC
2 pages
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation APC SUA1000RMI1U Kit. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel APC SUA1000RMI1U Kit ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation APC SUA1000RMI1U Kit décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation APC SUA1000RMI1U Kit devrait contenir:
- informations sur les caractéristiques techniques du dispositif APC SUA1000RMI1U Kit
- nom du fabricant et année de fabrication APC SUA1000RMI1U Kit
- instructions d'utilisation, de réglage et d’entretien de l'équipement APC SUA1000RMI1U Kit
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage APC SUA1000RMI1U Kit ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles APC SUA1000RMI1U Kit et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service APC en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées APC SUA1000RMI1U Kit, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif APC SUA1000RMI1U Kit, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation APC SUA1000RMI1U Kit. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
990-1086A 09/02 User’s Manual English APC Smart APC Smart APC Smart APC Smart- - - -UPS UPS UPS UPS ® ® ® ® 1000/750 VA 230/120/1 00VAC 1000/750 VA 230/120/1 00VAC 1000/750 VA 230/120/1 00VAC 1000/750 VA 230/120/1 00VAC 1U Rack Mount 1U Rack Mount 1U Rack Mount 1U Rack Mount Uninterrupti ble Power Supply Uninterrupti ble Power Supply Uninterr[...]
-
Page 2
[...]
-
Page 3
1 Introduction American Po w er Conversion Corp oration (APC) is the leading national and international manufac- turer of state-of- the-art unin terruptibl e power su pplies, redundant sw itches, power m anagement soft- ware, an d related equipm ent. APC products protect hardw are, software, an d data from power distur- banc es in b usine ss and go[...]
-
Page 4
2 Installing the R ails in the Rack The UPS fits in a standard 46. 5-cm (19- inch) rack. Mounting brack ets and rails are packaged s epa- rately within the main box . Cleats for rack mounting are preins talled on the UPS. 8 8 2[...]
-
Page 5
3 Mounting the UPS in a Rack The UPS is heavy. To lighten it, y ou m ay remove the battery before m ounting the unit in the rack (Steps 1 an d 2). Install the UPS at or near the bottom of the rack . Check to make sure the rack w ill not tip after installing the UPS into the rack. Step B Ste p A Step 1 Step 2 Be careful-the battery is heavy. Step 3 [...]
-
Page 6
4 Installing and Connecting the Battery and Attaching the Front Bezel Connecting Equipment and Power to the UPS S MART - UPS R EAR P ANEL 230V Models 120/100V Model s Step 1 Step 2 Step 3 Step 4[...]
-
Page 7
5 1. Connect equi pment to the UPS. Note: Do not connect a laser printer to the UPS. A laser printer d raws signifi cantly more p ower than other type s of equipm ent and m ay overload the UPS . 2. Add any option al accessories to the Smart-Slot. 3. Using a pow er cord, plug the UPS into a tw o-pole, three-wire, grounded receptacle only . Avoid u s[...]
-
Page 8
6 2: O PERA TION S MART - UPS F RONT P ANEL 230/100V Model s 120V Models Power On Power Off Online The online LED illu minates when the UPS is supplying utilit y power to the connected equipment. If the LED is not lit, the UPS is either not turned ON, or is supplying battery power.[...]
-
Page 9
7 AVR Tri m This LED illuminates to indicate the UPS is compensating for a hig h utility voltage. AVR Boost This LED illuminates to indicate the UPS is compensating for a low utility voltage. On Battery When the on batter y power LED is lit th e UPS i s supplying battery power to the con nected equipment. When on battery, the UPS sounds an alarm—[...]
-
Page 10
8 3: U SER C ONFIGU RA BLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HU TE SOFTW ARE OR OPTION AL S MA RT S LO T ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automa tic Self -Test Every 14 day s (336 hours) Every 7 days (168 hours), On Startup Only, No Self-Te st This func tion sets the int[...]
-
Page 11
9 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HU TE SOFTW ARE OR OPTION AL S MA RT S LO T ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Low Battery Warning. PowerChute in terface softw are prov ides auto- matic, unatte nded shut- down w hen appr oxim ately two m inutes (by def ault) of battery opera [...]
-
Page 12
10 4: S TO R AG E , M A INT ENA NCE , A ND T RANSPORTING Storage Store the UPS covered and positioned as for proper functioning, in a cool, dry location, with the bat- teries fully charged. At -15 t o +30 ° C (+5 to + 86 ° F), charge th e UPS battery every six months. At +30 t o +45 ° C (+86 to +11 3 ° F), charge the UPS battery every three m o[...]
-
Page 13
11 5: T ROUBLESHOOTING Use the chart belo w to sol ve minor Smart-UPS installation and operation problems. Refer to the APC web site, www.apc.com , for assistance with complex UPS problems. P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS WILL NOT TURN ON Batter y not conn ected prop- erly. Check that the battery conn ector is full y engaged. butto n n[...]
-
Page 14
12 P ROBLEM AND P OSSI BLE C AUSE S OLUTION T HE OVERLOAD LED IS LIT AND THE UPS EMITS A SUSTAINED ALARM TONE The UPS is overloaded. The conn ected equi pment exceed s the speci fied “maximu m load” as de- fine d in Spec ifications at the A PC we b site, www .apc.com . The alarm remai ns on un til the overload is removed . Discon nect nonessen [...]
-
Page 15
13 P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS OPERATES ON BA TTERY ALT HOUGH NORMAL LI NE VOLTAGE E XISTS UPS input circuit breake r tripped. Reduce the load on the U PS by unpl ugging equipm ent and res etting the circuit br eake r (on the ba ck of UPS) by pre ssing the plunge r in. Very high, low , or dist orted li ne voltage. Inexpens ive fuel[...]
-
Page 16
14 Service If the UPS requires s ervice do not return it to the dealer. Ins tead, follo w these steps: 1. Revi e w the problems discussed in t he Troubles hooting secti on of this m anual to eliminate com- mon probl ems. 2. If the problem persists, contact APC Customer Service th rough the APC web site, www.apc.com/su pport . Note the m odel nu[...]
-
Page 17
15 6: R EGULA TOR Y AND W AR R AN TY I NF ORMA T ION Regulatory Agency Approvals and Radio Frequency Warnings 230V MOD ELS This is a Class A prod uct. I n a dom estic env ironm ent this product ma y cause radi o int erference, in which cas e the u ser ma y be requi red t o take co rrect ive a c- tions . 120V MOD ELS This e quipm ent h as be en tes [...]
-
Page 18
16 Declaration of Conformity Limited Warranty American Power Conversion (APC) warrants it s products to be free from defects in materials and workmanshi p for a period of two years from th e date of purch ase. Its obli gation und er this warra nty is limi ted to rep airing or rep lacin g, at it s ow n sol e o p- tion, any such defecti ve produ cts.[...]