Briggs & Stratton 030209-2 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 48 pages
- 4.11 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Portable Generator
Briggs & Stratton 01933-1
56 pages 6.31 mb -
Portable Generator
Briggs & Stratton 030235-02
6 pages 0.68 mb -
Portable Generator
Briggs & Stratton 40276
7 pages 0.8 mb -
Portable Generator
Briggs & Stratton 540000
28 pages 2.28 mb -
Portable Generator
Briggs & Stratton N
22 pages 1.39 mb -
Portable Generator
Briggs & Stratton 30554
28 pages 1.85 mb -
Portable Generator
Briggs & Stratton 30204
28 pages 2.28 mb -
Portable Generator
Briggs & Stratton 313574
2 pages 0.78 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Briggs & Stratton 030209-2. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Briggs & Stratton 030209-2 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Briggs & Stratton 030209-2 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Briggs & Stratton 030209-2 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Briggs & Stratton 030209-2
- nom du fabricant et année de fabrication Briggs & Stratton 030209-2
- instructions d'utilisation, de réglage et d’entretien de l'équipement Briggs & Stratton 030209-2
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Briggs & Stratton 030209-2 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Briggs & Stratton 030209-2 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Briggs & Stratton en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Briggs & Stratton 030209-2, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Briggs & Stratton 030209-2, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Briggs & Stratton 030209-2. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Manual No. 199056GS Revision C (04/25/2008) BRIGGS & STRA TTON POWER PRODUCTS GROUP , LLC JEFFERSON, WISCONSIN, U.S.A. Portable Generator Operator’ s Manual This generator is rated in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators).[...]
-
Page 2
2 BRIGGSandSTRATTON.COM Briggs & Stratton Power Products Group, LLC 900 North Parkway Jefferson, WI 53549 Copyright © 2008 Briggs & Stratton Power Products Group, LLC. All rights reserved. No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs & Stratton Power[...]
-
Page 3
T able of Contents Operator Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Equipment Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Assembly . . . . . . . . . .[...]
-
Page 4
Operator Safety Equipment Description Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved. The generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, [...]
-
Page 5
5 W ARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. W ARNING Generator produces hazardous voltage. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.[...]
-
Page 6
6 BRIGGSandSTRATTON.COM W ARNING Contact with muffler area can result in serious burns. Exhaust heat / gases can ignite combustibles, structures or damage fuel tank causing a fire. • DO NOT touch hot parts and AVOID hot exhaust gases. • Allow equipment to cool before touching. • Keep at least 5 feet (1.5 m) of clearance on all sides of genera[...]
-
Page 7
Typical Generator Shown 7 Assembly Read entire operator’s manual before you attempt to assemble or operate your new generator. Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended fuel and oil. If you have any problems with the assembly of your generator, please call the generator hel[...]
-
Page 8
Add Engine Oil 1. Place generator on a flat, level surface. 2. Clean area around oil fill and remove yellow oil fill cap. 3. Using oil funnel (optional), slowly pour contents of provided oil bottle into oil fill opening. 4. Replace oil fill cap and fully tighten. Add Fuel Fuel must meet these requirements: • Clean, fresh, unleaded gasoline. • A[...]
-
Page 9
9 System Ground The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. The system ground is connected to the AC neutral wire (the neutral is bonded to the generator frame). Special Requirements There may be Federal or State Occupational Safety and Health Administration (O[...]
-
Page 10
10 BRIGGSandSTRATTON.COM Features and Controls Read this Operator’s Manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. A - 120 Volt AC, 20 Amp, Duplex Receptacles — May be us[...]
-
Page 11
11 Cord Sets and Receptacles Use only high quality, well-insulated, grounded extension cords with the generator’s 120 Volt duplex receptacle. Inspect extension cords before each use. Check the ratings of all extension cords before you use them. Extension cord sets used should be rated for 125 Volt AC loads at 20 Amps or greater for most electrica[...]
-
Page 12
Operation Starting the Engine Disconnect all electrical loads from the generator. Use the following start instructions: 1. Make sure unit is on a level surface. IMPORTANT: Failure to start and operate the unit on a level surface will cause the unit not to start or shut down during operation. 2. Turn fuel valve to “ On ” position. Fuel valve han[...]
-
Page 13
Connecting Electrical Loads 1. Let engine stabilize and warm up for a few minutes after starting. 2. Plug in and turn on the desired 120/240 Volt AC, single phase, 60 Hz electrical loads. NOTE: • DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles. • DO NOT connect 3-phase loads to the generator. • DO NOT connect 50 Hz loads to t[...]
-
Page 14
Don’t Overload Generator Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1. Select the items you will power at the same time. 2. Total the rated (running) watts of these items. This is the amount of power your generato[...]
-
Page 15
15 Maintenance Maintenance Schedule Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below. 1 Service more often under dirty or dusty conditions. General Recommendations Regular maintenance will improve the performance and extend the life of the generator. [...]
-
Page 16
Engine Maintenance Oil Oil Recommendations We recommend the use of Briggs & Stratton Warranty Certified oils for best performance. Other high-quality detergent oils are acceptable if classified for service SF, SG, SH, SJ or higher. DO NOT use special additives. Outdoor temperatures determine the proper oil viscosity for the engine. Use the char[...]
-
Page 17
17 Service Air Cleaner Your engine will not run properly and may be damaged if you run it with a dirty air cleaner. Replace the air cleaner every 25 hours of operation or once each year, whichever comes first. Replace more often if operating under dirty or dusty conditions. To service the air cleaner, follow these steps: 1. Loosen screws ( A ) and [...]
-
Page 18
Air Cooling System Over time debris may accumulate in cylinder cooling fins and cannot be observed without partial engine disassembly. For this reason, we recommend you have an authorized Briggs & Stratton service dealer clean the cooling system ( A ) per recommended intervals (see Maintenance Schedule in beginning of Maintenance section). Equa[...]
-
Page 19
19 Storage The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage. Generator Storage • Clean the generator as outlined in Cleaning . • Check that cooling air slots and o[...]
-
Page 20
20 BRIGGSandSTRATTON.COM T roubleshooting Problem Cause Correction Engine is running, but no AC output is available. 1. One of the circuit breakers is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad. 1. Reset circuit breaker. 2. Contact authorized service facility. 3. Check and repair. 4. Connect an[...]
-
Page 21
21 W arranties Emissions Control System Warranty Briggs & Stratton Corporation (B&S), the California Air Resources Board (CARB) and the United States Environmental Protection Agency (U.S. EPA) Emissions Control System Warranty Statement (Owner’s Defect Warranty Rights and Obligations) California, United States and Canada Emissions Control[...]
-
Page 22
22 BRIGGSandSTRATTON.COM 2. Length of Coverage B&S warrants to the initial owner and each subsequent purchaser that the Warranted Parts shall be free from defects in materials and workmanship which caused the failure of the Warranted Parts for a period of two years from the date the engine is delivered to a retail purchaser. 3. No Charge Repair[...]
-
Page 23
23 BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC PORTABLE GENERATOR OWNER WARRANTY POLICY LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that is defective in material or workmanship or both. Transportation charges on product submitted for repair or rep[...]
-
Page 24
24 BRIGGSandSTRATTON.COM Briggs & Stratton Power Products Group, LLC 900 N. Parkway Jefferson, Wisconsin, 53549 U.S.A. Portable Generator Power Ratings: The gross power rating for individual gas engine models is labeled in accordance with SAE (Society of Automotive Engineers) code J1940 (Small Engine Power & Torque Rating Procedure), and ra[...]
-
Page 25
BRIGGS & STRA TTON POWER PRODUCTS GROUP , LLC JEFFERSON, WISCONSIN, U.S.A. Generador Portátil Manual del Operario Este generador está clasificado conforme a la norma C22.2 No. 100-04 (motores y generadores) de la CSA (Canadian Standards Association [Asociación canadiense de normalización]).[...]
-
Page 26
2 BRIGGSandSTRATTON.COM Muchas gracias por comprar este generador Briggs & Stratton de gran calidad. Nos alegra que haya depositado su confianza en la marca Briggs & Stratton. Siempre que sea utilizado de acuerdo con las instrucciones de este manual, su generador Briggs & Stratton le proporcionará muchos años de buen funcionamiento. E[...]
-
Page 27
T abla de Contenido Seguridad de operario . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Descripción del equipo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Reglas de seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Montaje . . . . . . . . . . . . . . . [...]
-
Page 28
Seguridad de operario Descripción del equipo Lea atentamente este manual y familiarícese con el generador. Conozca sus aplicaciones, limitaciones y riesgos. Este generador funciona en base a un motor de campo eléctrico giratorio y de corriente alterna (CA). Fue diseñado con la finalidad de proveer energía eléctrica para lámparas eléctricas,[...]
-
Page 29
5 Español ADVERTENCIA El escape del motor de este producto contiene elementos químicos reconocidos en el Estado de California por producir cáncer, defectos de nacimiento u otros daños de tipo reproductivo. ADVERTENCIA El retroceso (repliegue rápido) del cable del arrancador puede producir lesiones. El retroceso impedirá que el usuario suelte [...]
-
Page 30
6 BRIGGSandSTRATTON.COM ADVERTENCIA El contacto con la zona del silenciador puede producir quemaduras graves. Los gases y el calor de escape pueden inflamar los materiales combustibles y las estructuras o dañar el depósito de combustible y provocar un incendio. • NO toque las superficies calientes y EVITE los gases del escape a alta temperatura[...]
-
Page 31
Montaje Su generador requiere de ciertos procedimientos de montaje y solo estará listo para ser utilizado después de haberle suministrado servicio con el combustible y aceite recomendados. Si usted tiene problemas con el montaje de su generador, por favor llame a la línea de ayuda para generadores al (800) 743-4115 . Si llamar para la ayuda, tie[...]
-
Page 32
Agregar aceite al motor 1. Coloque la generador en una superficie plana y nivelada. 2. Limpie la zona de alrededor del orificio de llenado de aceite y quite el tapón amarillo. 3. Con la ayuda de un embudo (opcional), vierta lentamente todo el contenido de la botella de aceite por el orificio de llenado de aceite. 4. Vuelva a colocar el tapón y ap[...]
-
Page 33
9 Español Tierra del sistema El generador dispone de una conexión a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA. La tierra del sistema está conectada al cable de CA neutro que, a su vez, está conectado al bastidor del generador (el neutro está conectado al bastid[...]
-
Page 34
10 BRIGGSandSTRATTON.COM A - Tomacorriente Dobles de 120 Voltios AC, 20 Amp — Pueden ser utilizados para suministrar alimentación eléctrica para el funcionamiento de cargas del motor, herramientas, aparatos especiales e iluminación eléctrica de 120 Voltios AC a 20 Amperios, monofásica de 60 Hz. B - Cortacircuitos (AC) — Cada tomacorriente [...]
-
Page 35
11 Juegos de cordones y enchufes conectores Utilice exclusivamente cables prolongadores de alta calidad, bien aislados y con conexión a tierra para la toma doble de 120 V del generador. Examine los cables prolongadores antes de cada uso. Revise las capacidades de todos las cordones de extensión antes de usarlos. Los juegos de cordones de extensi?[...]
-
Page 36
Operando Encienda el motor Desconecte todas las cargas eléctricas del generador. Use las siguientes instrucciones para encender: 1. Asegúrese de que la unidad está en una superficie plana. IMPORTANTE: Si la unidad no se arranca y utiliza en una superficie plana, se pueden producir problemas de arranque y de parada durante el funcionamiento. 2. G[...]
-
Page 37
Conexión de cargas eléctricas 1. Deje que el motor se estabilice y se caliente por dos minutos después del arranque. 2. Enchúfelo y encienda la carga eléctrica deseada (120/240 V CA, monofásico, 60 Hz.) NOTA: • NO conectar cargas de 240 V en las tomas eléctricas dobles. • NO conectar cargas trifásicas al generador. • NO conectar carga[...]
-
Page 38
No sobrecargar el generador Capacidad Debe asegurarse de que su generador puede proveer los suficientes vatios de potencia continua (vatiaje nominal) y vatios de salida para los elementos que desee alimentar al mismo tiempo. Siga estos sencillos pasos: 1. Seleccione los elementos que quiere alimentar al mismo tiempo. 2. Sume la potencia nominal de [...]
-
Page 39
Mantenimiento Plan de mantenimiento Siga los intervalos de horas o de calendario, los que sucedan antes. Si opera en condiciones adversas (señaladas más abajo) es necesario un mantenimiento más frecuente. 1 Servicio más a menudo bajo condiciones de suciedad o polvo. Recomendaciones Generales El mantenimiento periódico mejorará el rendimiento [...]
-
Page 40
Mantenimiento del Motor Aceite Recomendaciones sobre el aceite Para obtener el mejor rendimiento, recomendamos utilizar aceites certificados con garantía Briggs & Stratton. También se pueden utilizar otros aceites detergentes de alta calidad con clasificación de servicio SF, SG, SH, SJ o superior. NO utilice aditivos especiales. Las temperat[...]
-
Page 41
3. Limpie la zona de alrededor del tapón de vaciado de aceite ( A ), situado en la base del motor, al otro lado del carburador. 4. Quite el tapón de llenado de aceite y vacíe todo el aceite en un recipiente adecuado. 5. Vuelva a colocar el tapón de vaciado y apriételo bien. Quite el tapón de llenado de aceite. 6. Vierta lentamente unos 0,6 li[...]
-
Page 42
Si el motor ha estado funcionando, el silenciador estará bastante caliente. Deje que el silenciador se enfríe para poder darle servicio al apagachispas. • Retire la pantalla del apagachispas para limpieza e inspección. • Remplace la pantalla si está dañada. Sistema de refrigeración de aire Con el tiempo, se pueden acumular residuos en las[...]
-
Page 43
Almacenamiento El generador deberá ser encendido al menos una vez cada siete días y deberá dejarlo funcionar al menos durante 30 minutos. Si no puede hacer esto y debe almacenar la unidad por más de 30 días, siga las siguientes instrucciones para preparar su unidad para almacenamiento. Generador 1. Limpie el generador como está descrito en Li[...]
-
Page 44
20 BRIGGSandSTRATTON.COM Resolución de problemas Problemo Causa Accion El motor está funcionando pero no existe salida de AC disponsible. 1. El interruptor automático de circuito está abierto. 2. Conexión mal o defectuosa del juego de cables. 3. El dispositivo conectado está dañado. 4. Avería en el generador. 1. Reposicione el interruptor. [...]
-
Page 45
Garantías Garantía del sistema de control de emisiones Briggs & Stratton Corporation (B&S), el California Air Resources Board (CARB, Consejo de recursos de aire de California) y la United States Environmental Protection Agency (U.S. EPA, Agencia estadounidense de protección del medioambiente) Declaración de garantía del sistema de cont[...]
-
Page 46
e. Elementos diversos utilizados en los sistemas anteriores • Válvulas y conmutadores de aspiración, temperatura, posición y temporizados • Conectores y unidades 2. Duración de la cobertura B&S garantiza al propietario inicial y a cada comprador posterior que las piezas garantizadas no tendrán defectos de materiales ni de mano de obra [...]
-
Page 47
23 Español Esperamos que disfrute de nuestra garantía y le pedimos disculpas por las molestias causadas. Cualquier distribuidor de servicio autorizado puede llevar a cabo reparaciones en garantía. La mayoría de las reparaciones en garantía se gestionan normalmente, pero algunas veces la solicitud de servicio en garantía puede no ser procedent[...]
-
Page 48
24 BRIGGSandSTRATTON.COM Briggs & Stratton Power Products Group, LLC 900 N. Parkway Jefferson, Wisconsin, 53549 U.S.A. Generador Portátil Potencia nominal: El valor de potencia bruta de cada modelo de motor de gasolina se indica en la etiqueta conforme a los requisitos del código J1940 (Procedimiento de valoración de potencia y par de peque?[...]