DeVillbiss Air Power Company SP-100-F manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 16 pages
- 0.25 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Air Compressor
DeVillbiss Air Power Company SB-2-540
20 pages 0.6 mb -
Air Compressor
DeVillbiss Air Power Company 38301-9615
12 pages 0.14 mb -
Air Compressor
DeVillbiss Air Power Company Companion 919.19007
8 pages 0.16 mb -
Air Compressor
DeVillbiss Air Power Company MGP-102D-2
16 pages 0.32 mb -
Air Compressor
DeVillbiss Air Power Company WB100D-2
12 pages 0.1 mb -
Air Compressor
DeVillbiss Air Power Company SP-100-E
12 pages 0.1 mb -
Air Compressor
DeVillbiss Air Power Company MG2-OFTANK-4A
12 pages 0.14 mb -
Air Compressor
DeVillbiss Air Power Company MGAT-1
12 pages 0.24 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation DeVillbiss Air Power Company SP-100-F. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel DeVillbiss Air Power Company SP-100-F ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation DeVillbiss Air Power Company SP-100-F décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation DeVillbiss Air Power Company SP-100-F devrait contenir:
- informations sur les caractéristiques techniques du dispositif DeVillbiss Air Power Company SP-100-F
- nom du fabricant et année de fabrication DeVillbiss Air Power Company SP-100-F
- instructions d'utilisation, de réglage et d’entretien de l'équipement DeVillbiss Air Power Company SP-100-F
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage DeVillbiss Air Power Company SP-100-F ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles DeVillbiss Air Power Company SP-100-F et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service DeVillbiss Air Power Company en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées DeVillbiss Air Power Company SP-100-F, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif DeVillbiss Air Power Company SP-100-F, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation DeVillbiss Air Power Company SP-100-F. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615 MG3-OLPORT-3A 11/6/98 GE NE RA L MA NU A L FO R OIL L UBR IC A TE D SINGLE ST A GE POR T A BL E AIR C OMP RE SS OR T ABLE OF CONTENTS SAFETY GUIDELINES - DEFINITIONS Information for preventing damage to equipment. This manual contains information that is important for y[...]
-
Page 2
2 LIMITED W ARRANTY ONE YEAR FROM DA TE OF PURCHASE All merchandise manufactured by DeVilbiss Air Power Company/ExCell Manufacturing is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user). Products covered under this warranty include: air co[...]
-
Page 3
3 RISK OF BURSTING RISK OF EXPLOSION OR FIRE RISK OF ELECTRICAL SHOCK AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A VIOLENT TANK EXPLOSION: 1. FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK, CAUSING RUST AND THINNING OF THE STEEL TANK. 2. MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK. 3. UNAUTHOR[...]
-
Page 4
4 HAZARD RISK OF ELECTRICAL SHOCK (cont’d) RISK FROM FLYING OBJECTS RISK TO BREATHING RISK OF FALLING RISK FROM MOVING PARTS RISK OF BURNS WHAT CAN HAPPEN REPAIRS ATTEMPTED BY UNQUALIFIED PERSONNEL CAN RESULT IN SERIOUS INJURY OR DEATH BY ELECTROCUTION. ELECTRICAL GROUNDING: FAILURE TO PROVIDE ADEQUATE GROUNDING TO THIS PRODUCT COULD RESULT IN SE[...]
-
Page 5
5 GLOSSARY CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds per square inch gauge; a unit of measure of pressure. ASME: American Society of Mechanical Engineers; made, tested, inspected and registered to meet the standards of ASME. U.L. Listed: Products with the U.L. mark are listed b[...]
-
Page 6
6 DESCRIPTION OF OPERATION (cont'd) Outlet Pressure Gauge: The outlet pressure gauge indi- cates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less or equal to the tank pressure. See “Operating Procedures”. Tank Pressure Gauge: The tank pressure gauge indicates th[...]
-
Page 7
7 Voltage and Circuit Protection Refer to your Parts Manual for voltage and circuit protection requirements of your compressor. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the compressor is connected to a circuit protected by fuses, use only dual element time delay fuses, as[...]
-
Page 8
8 4. Clean or blow off fins or any part of compressor that collects dust and dirt. Compressor will run cooler and provide longer service. 5. Before attaching an air hose or accessory make sure the pressure switch lever is in the "OFF" position. Close the air regulator outlet by turning it counterclock- wise. 6. Attach hose and accessory S[...]
-
Page 9
9 MAINTENANCE UNIT CYCLES AUTOMATICALLY WHEN POWER IS ON. DURING MAINTENANCE, YOU COULD BE EXPOSED TO VOLTAGE SOURCES, COM- PRESSED AIR OR MOVING PARTS. PERSONAL INJURIES CAN OCCUR. UNPLUG THE UNIT AND BLEED OFF ALL AIR TANK PRESSURE BEFORE DOING ANY MAINTENANCE OR REPAIR. NEVER OPERATE THE UNIT WITH THE BELT GUARD REMOVED. To ensure efficient oper[...]
-
Page 10
10 NOTE If the overload protector shuts the motor off frequently, check for a possible voltage prob- lem. Low voltage can also be suspected when: 1 . The motor does not get up to full power or speed. 2 . Fuses blow out when the motor is started. 3 . Lights dim when motor is started, and re main dim while it is running. Pulley and Flywheel - Alignme[...]
-
Page 11
11 TROUBLESHOOTING GUIDE PERFORMING REPAIRS MAY EXPOSE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES. PERSONAL INJURY MAY OCCUR. PRIOR TO ATTEMPTING ANY REPAIRS, UNPLUG THE COMPRESSOR AND BLEED OFF ALL TANK AIR PRESSURE. PROBLEM Excessive tank pressure - safety valve pops off. Air leaks at fittings. Air leaks at or inside check valve. Air[...]
-
Page 12
12 TROUBLESHOOTING GUIDE (CONT'D) PROBLEM Knocking noise Motor will not run. CAUSE Restricted or defective check valve. Loose pulley. Low oil level. Loose flywheel. Loose compressor mounting screws. Loose belt. Belt too tight. Carbon build-up. Motor overload protection switch has tripped. Possible defective capacitor. Possible defective motor.[...]
-
Page 13
13 TROUBLESHOOTING GUIDE (CONT'D) PROBLEM Restricted air intake. Compressor is not supplying enough air to operate accessories. Excessive belt wear. Squealing sound. Pressure reading on the regulated pres- sure gauge drops when an accessory is used. Regulator knob - continuous air leak. Regulator will not shut off at air outlet. CAUSE Dirty ai[...]
-
Page 14
14 SER VICE NOTES[...]
-
Page 15
15 SERVICE NOTES[...]
-
Page 16
DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615 GENE RAL M ANU AL F OR OIL L UBRIC A TED SINGLE ST A GE P OR T ABL E AIR COMP RE SS OR SER VICE NOTES[...]