Hunter Fan 43042-01 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 21 pages
- 6.97 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Ventilation Hood
Hunter Fan 48055
12 pages 2.1 mb -
Ventilation Hood
Hunter Fan 43041-01
65 pages 15.91 mb -
Ventilation Hood
Hunter Fan 83004
40 pages 8.65 mb -
Ventilation Hood
Hunter Fan 90052
40 pages 8.01 mb -
Ventilation Hood
Hunter Fan 90053
40 pages 8.01 mb -
Ventilation Hood
Hunter Fan 82004
28 pages 4.54 mb -
Ventilation Hood
Hunter Fan 82022
60 pages 14.41 mb -
Ventilation Hood
Hunter Fan 90057
40 pages 8.66 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Hunter Fan 43042-01. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Hunter Fan 43042-01 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Hunter Fan 43042-01 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Hunter Fan 43042-01 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Hunter Fan 43042-01
- nom du fabricant et année de fabrication Hunter Fan 43042-01
- instructions d'utilisation, de réglage et d’entretien de l'équipement Hunter Fan 43042-01
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Hunter Fan 43042-01 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Hunter Fan 43042-01 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Hunter Fan en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Hunter Fan 43042-01, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Hunter Fan 43042-01, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Hunter Fan 43042-01. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
43042-01 02/21/2008 1 FRANÇAIS Consulter la page 45 ENGLISH See page 2 ESP AÑOL V ea la p á gina 23 82048 T urino Bath V entilator with Light READ and SA VE THESE INSTRUCTIONS Installation Guide[...]
-
Page 2
43042-01 02/21/2008 2 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: PREVENT A TIVE MAINTENANCE A clean fan provides better service. Disconnect the power supply and clean the fan as listed below . TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths[...]
-
Page 3
43042-01 02/21/2008 3 D 95044-01-000 N 75184-01-133 L 97959-01-000 K 65219-01-000 J 77521-01-000 E 95029-01-000 A x4 F 75191-01-000 G 03242-07-133 I H 74508-03-133 98037-01-000 x2 O 97960-01-000 M 75729-01-000 P 77535-01-000 Check all the parts. If damaged, call 1-888-830-1326 for replacements. T ools Needed. Estimated assembly time: 30 to 60 minut[...]
-
Page 4
43042-01 02/21/2008 4 Remove the motor/blower from the housing. Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. Remove packing material. T urn off the power source. Before Installation Loosen screws. NOTE: Remove all packing materials before installation. 1 2 3 5 6 4 H H I E ENGLI[...]
-
Page 5
43042-01 02/21/2008 5 7 G Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer . Remove the wiring cover screw . Remove the wiring cover . Choose Installation Option For New Construction - attaching to joist fo to step A1 1, page 6 For New Construction - suspended between j[...]
-
Page 6
43042-01 02/21/2008 6 5/8 1/2 A1 1 A13 A12 E Connect wires as shown. Pull wires through the strain relief. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. New Construction – attaching to joist Screw pre-loaded screws into joist or framing. A14 F A Fan Motor Light 2 Pin Black Ground Green B[...]
-
Page 7
43042-01 02/21/2008 7 0 0 0 0 0 0 0 0 0 A15 A18 A20 A19 A17 A16 F H I G E Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Secure the motor by tightening the 2 screws. T urn on the power source. Conn[...]
-
Page 8
43042-01 02/21/2008 8 5/8 1/2 5/8 1/2 1/8" Bit Slide the mounting rails into brackets. Mark position of screws by using holes as a template. New Construction – suspended between joists Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Drill a hole in the center of each outline. T est th[...]
-
Page 9
43042-01 02/21/2008 9 Connect wires as shown. T ighten screws. Pull wires through the strain relief. Insert screws, leaving space between the screw head and the joist. Screws are not provided. Attach the rails onto the screws. B15 B16 B17 B18 B19 F A Fan Motor Light 2 Pin Black Ground Green Bare Copper White Black Main Switch 1 (AC In) Black Switch[...]
-
Page 10
43042-01 02/21/2008 10 Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. T urn on the power source. Secure the motor by tightening the 2 screws. Connect 4” duct and vent to the outside. T ape joints[...]
-
Page 11
43042-01 02/21/2008 11 8” 8.5” B26 C1 1 C12 B27 E1 Go to step on page 18 to attach grille. Existing Construction – accessible from above OR Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (8”x 8.5”). Cut out an opening for the housing. Use the motor housing as a template to ma[...]
-
Page 12
43042-01 02/21/2008 12 1/8" Bit 5/8 1/2 5/8 1/2 C13 C14 C15 C16 C17 C18 Drill a hole in the center of each outline. Insert screws, leaving space between the screw head and the joist. Screws are not provided. Attach the rails onto the screws. T ighten screws. Position the correct depth mark at the bottom edge of the joist based on the thickness[...]
-
Page 13
43042-01 02/21/2008 13 C19 C20 C21 T ighten the strain relief screws. Connect 4” duct and vent to the outside. T ape joints. If ducting does not fit securely , an adapter may need to be purchased. Pull wires through the strain relief. Connect wires as shown. C22 F A Fan Motor Light 2 Pin Black Ground Green Bare Copper White Black Main Switch 1 (A[...]
-
Page 14
43042-01 02/21/2008 14 Secure the motor by tightening the 2 screws. T urn on the power source. T est the motor . If the motor does not run, check the plug connection. Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into posi[...]
-
Page 15
43042-01 02/21/2008 15 2 1 Existing Construction – accessible only from below Pull wires through strain relief . Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (8”x 8.5”). Move the housing into position above the ceiling. Attach existing ducting to duct connector . T ape joints. [...]
-
Page 16
43042-01 02/21/2008 16 D15 E D16 D17 D18 F G F H A Fan Motor Light 2 Pin Black Ground Green Bare Copper White Black Main Switch 1 (AC In) Black Switch 2 (AC In) Black Light *Option White White 3 Pin *Option Fan & Main Light T ogether Connect wiring from the motor to the wiring cover plate. Install the wiring cover plate. Install the housing flu[...]
-
Page 17
43042-01 02/21/2008 17 D19 D20 H I D21 D22 D23 E1 Go to step on page 18 to attach grille. T est the motor . If the motor does not run, check the plug con- nection. T urn on the power source. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the mo- tor and the housing. Secure the mot[...]
-
Page 18
43042-01 02/21/2008 18 E1 E3 E4 E5 E6 E2 K K J L Align posts A, B, C and D (stamped into motor housing) with posts A, B, C and D (stamped into light fixture). Slide light fixture over posts. Remove the strain relief bracket screw . Position the strain relief bracket under the motor as shown. Insert the strain relief bracket’s dog-leg tab so that [...]
-
Page 19
43042-01 02/21/2008 19 Align glass dome and push up. Screw glass stop into position. Screw Finial into position Complete. Attach thumbscrews. W ARNING: T o reduce the risk of electrical shock, all 4 thumbscrews MUST be properly installed. Install 2 Max 60 W att A15 bulbs (Not Included). E7 E10 E9 E1 1 E12 E8 N O M P ENGLISH[...]
-
Page 20
43042-01 02/21/2008 20 T rouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath V entilators are extremely quiet. T o conrm that the fan is running, place your hand near the vents to feel the air movement. • T urn power on, replace fuse, or reset breaker . • Check all plug connections to be sure they are secure. • Che[...]
-
Page 21
43042-01 02/21/2008 21 W arranty © 2008 Hunter Fan Company Hunter Fan Company Bath Exhaust Fan LIMITED W ARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass xtures and light bulbs) fails at any ti[...]