MGE UPS Systems 2200RT manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 28 pages
- 0.51 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Power Supply
MGE UPS Systems 22+ EB 22
44 pages 0.55 mb -
Power Supply
MGE UPS Systems FlexPDU 8 DIN
12 pages 0.86 mb -
Power Supply
MGE UPS Systems 5000 RT
44 pages 2.24 mb -
Power Supply
MGE UPS Systems FlexPDU 6 BS
12 pages 0.86 mb -
Power Supply
MGE UPS Systems EPS 7000
48 pages 1.43 mb -
Power Supply
MGE UPS Systems Pulsar TM EX30
18 pages 0.2 mb -
Power Supply
MGE UPS Systems EX 11RT
72 pages 3.87 mb -
Power Supply
MGE UPS Systems 2200C
28 pages 0.84 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation MGE UPS Systems 2200RT. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel MGE UPS Systems 2200RT ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation MGE UPS Systems 2200RT décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation MGE UPS Systems 2200RT devrait contenir:
- informations sur les caractéristiques techniques du dispositif MGE UPS Systems 2200RT
- nom du fabricant et année de fabrication MGE UPS Systems 2200RT
- instructions d'utilisation, de réglage et d’entretien de l'équipement MGE UPS Systems 2200RT
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage MGE UPS Systems 2200RT ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles MGE UPS Systems 2200RT et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service MGE UPS Systems en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées MGE UPS Systems 2200RT, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif MGE UPS Systems 2200RT, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation MGE UPS Systems 2200RT. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
www.mgeups.com Pulsar EX 2200RT / 3200R T EXB 2200/3200 RT Installation and User Manual MGE UPS SYSTEMS,INC.[...]
-
Page 2
SA VE THESE INSTRUCTIONS. This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Thank you for selecting an MGE UPS SYSTEMS, Inc. product to protect your electrical equipment. The Pulsar EX RT range has been designed with the utmost care. We recommend that you take the time [...]
-
Page 3
3400753300/AE - Page 3 CAUTION: Safety of persons ◗ The UPS has its own internal power source (the battery). Consequently , the power outlets may be energized even if the UPS is disconnected from the AC-power source. ◗ Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personnel. ◗ The UP[...]
-
Page 4
Page 4 - 3400753300/AE Using this document How to use this document Icon Usage Information may be found primarily by consulting: ◗ The contents, ◗ The index. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. Audio indication. Action. V isual indication. Notes, tips and information, help. CAU[...]
-
Page 5
3400753300/AE - Page 5 1. Presentation 1.1 System configurations ....................................................................................................... ......... 7 Rack setup ......................................................................................................................................7 T ower setup .........[...]
-
Page 6
Page 6 - 3400753300/AE 4. Maintenance 4.1 T roubleshooting .......................................................................................................................... 20 4.2 Replacement of the battery modules ........................................................................................ 22 5. Environment ...................[...]
-
Page 7
P U L S A R w w w. m g e u p s . c o m 1 0 0 % 8 0 % 5 0 % 2 0 % t e s t % 1 2 % B Y P A S S E X 3400753300/AE - Page 7 Tower setup Rack setup 1.1 System configurations 1. Presentation w w w . m g e u p s . co m P U L S A R 3.75 inches (2U) 25.75 inches (EX 2200RT) 26.00 inches (EX 3200RT) 17.24 inches (19" Rack mount) 1 0 0 % 8 0 % 5 0 % 2 0 [...]
-
Page 8
Page 8 - 3400753300/AE 4 6 12 11 10 9 8 7 1 3 2 4 12 11 10 9 8 7 5 3 2 1 15 14 15 14 13 12 Pulsar EXB 2200/3200 RT Pulsar EX 3200RT Pulsar EX 2200RT 11 10 8 9 7 6 5 4 3 2 1 Slot for communication-card option. RS232 communication port. USB communication port. Upper two receptacles for connection to AC-power source. Lower two programmable receptacles[...]
-
Page 9
3400753300/AE - Page 9 27 26 25 24 23 22 21 20 19 18 17 16 (*) : ◗ flashing LED + buzzer: battery fault (battery must be replaced). ◗ flashing LED + long buzzer (once per hour): theoretical end of battery life (replacement recommended). UPS overload Electronics fault Battery fault * Site Wiring Fault 26 27 % load 100% 80% 50% 20% Press simultan[...]
-
Page 10
Page 10 - 3400753300/AE 34 34 36 35 36 35 30 32 31 30 32 31 RS232 communication cable. USB communication cable. T elescopic rails for mounting in 19" bay with mounting hardware. CD-ROM with the Solution-Pac and UPS Driver software. Product documentation. T wo supports for the upright position. 2.1 Unpacking 2. Installation P U L S A R EX www.m[...]
-
Page 11
3400753300/AE - Page 11 3 3 7 Stop-Notch Snap from inside of rails 2 6 4 5 5 2 1 CAUTION: Do not lean or place objects on top of unit at any time. Hazard of dismounting and disconnection can occur with units. NOTE: (For step 5) it is possible to adjust the position of the front fixing bracket. Follow steps A to D for rack mounting of the UPS on the[...]
-
Page 12
Page 12 - 3400753300/AE Install the two supports for the upright position using provided hardware in the package. (see item 32 on page 10). Pull out the MGE Logo and Model plates, then rotate them as shown. 2. Installation 2.3 Installation in tower position P U L S A R P U L S A R www. mg e ups.com w w w .m geu ps . c o m 1 0 0 % 8 0 % 5 0 % 2 0 % [...]
-
Page 13
3400753300/AE - Page 13 1 Slot for the communication card option. It is not necessary to shut down the UPS to install the communication card: 1. Remove the slot 1 cover secured by two screws. 2. Insert the card in the slot. 3. Secure the card with the two screws. 2.5 Installation of the communication-card option NOTE: The RS232 and USB communicatio[...]
-
Page 14
Page 14 - 3400753300/AE 5 4 4 7 1. Connect the input power cord 7 to the AC-power wall-receptacle. 2. Connect the protected equipment to the UPS. It is advised to connect priority loads to the outlets and/or power cord 4 and any non-priority loads to the two programmable outlets 5 (If the UPS is connected to a computer running MGE UPS SYSTEMS, Inc.[...]
-
Page 15
3400753300/AE - Page 15 27 26 25 18 17 16 24 20 19 21 22 23 27 26 25 18 17 16 Description of LED indicator status 20 and 21 for programmable outlets 1 and 2: ◗ OFF: the outlets are not supplied with power . ◗ Flashing: status change in progress. ◗ ON: the outlets are supplied with power . Outlets 1 and 2 can be remotely programmed and control[...]
-
Page 16
Page 16 - 3400753300/AE 22 17 17 The UPS goes to sleep mode at the end of the battery backup time, until complete shutdown, due to tripping of the battery-protection function against deep discharge. Return of AC input power: IMPORT ANT : If, in spite of the return of AC input power, the UPS does not restart, check that the automatic-restart functio[...]
-
Page 17
3400753300/AE - Page 17 "ON / OFF conditions" tab Options Once a day Once a month No test From 0% to 100% of the remaining battery backup time Disabled Default setting Every weeks 20% remaining battery backup time Enabled Personalization function Automatic "Battery test" intervals "Low-battery warning" threshold Protec[...]
-
Page 18
Page 18 - 3400753300/AE 16 Press button 16 (return to the OFF position). The connected equipment is no longer supplied with power . 3.5 UPS shutdown "Bypass" tab "Output" tab Options Disabled (click to remove check) Enabled (click to add check) Default setting Enabled Disabled Personalization function T ransfer to bypass if over[...]
-
Page 19
3400753300/AE - Page 19 38 37 12 1. Check that the UPS is shut off and disconnected from the AC power source. 2. Remove the RPO connector 12 by undoing the screws 37 . 3. Connect an insulated dry contact (NC, 60 V DC, 30 V AC max., 20 mA max., cable size 0.75 mm) to the two terminals of the RPO connector 38 . 4. Put the RPO connector 12 back in pla[...]
-
Page 20
Indication Diagnostic Correction LED 27 flashes and UPS overload. Overload is too long or too high. ◗ Check the power drawn by the the buzzer beeps. ◗ If AC power is present and within tolerances, the equipment and disconnect any UPS goes to bypass mode (supply directly by the non-priority devices. AC-power source). LED 19 flashes. The buzzer b[...]
-
Page 21
3400753300/AE - Page 21 Indication Signification Correction The outlets are not supplied One of the protection circuit breakers 6 for the ◗ Check that there is not a short- with power , even though outlets (on the back of the UPS) is open. circuit on the outlets. button 16 is ON ◗ Eliminate any overloads on the (3200 RT only). outlets by modify[...]
-
Page 22
C D P U L S A R 1 0 0% 8 0% 5 0% 2 0 % t e st % 1 2 % B Y PA SS E X B A w w w . m ge u p s. c o m P U L S A R 1 0 0% 8 0 % 50 % 2 0 % t es t % 1 2 % B Y P A S S E X Page 22 - 3400753300/AE C - Remove the left part of the front panel. D - Disconnect the connector . A - Unclip the small plate with the MGE UPS SYSTEMS, Inc. Logo on the UPS front panel[...]
-
Page 23
3400753300/AE - Page 23 G - Remove the two battery modules and proceed with replacement. Reinstallation of the battery module s To reinstall the battery modules perform this procedure in reverse order e.g., “G”, “F”, “E”. ◗ To maintain an identical level of performance and safety , use battery modules identical to that previously moun[...]
-
Page 24
Page 24 - 3400753300/AE This product has been designed to respect the environment: It does not contain CFC's or HCFC's. UPS recycling at the end of service life: MGE UPS SYSTEMS, Inc. undertakes to recycle, by certified companies and in compliance with all applicable regulations, all UPS products recovered at the end of their service life[...]
-
Page 25
Output power rating AC-input ◗ V oltage ◗ Frequency ◗ Power factor Output specification ◗ V oltage ◗ Frequency ◗ Harmonic distortion ◗ Overload capability Battery (sealed lead-acid, maintenance free) Environmental and safety ◗ Noise level ◗ Operating temperature ◗ Relative humidity ◗ Safety ◗ EMC ◗ Agency markings < 50 [...]
-
Page 26
Page 26 - 3400753300/AE Authorized voltage range for Upper and lower voltage thresholds within which the UPS can operate on the automatic transfer to bypass if fault or bypass in the event of a UPS fault or overload. overload Automatic bypass Automatic switch controlled by the UPS, used to connect the equipment directly to the AC-power source in th[...]
-
Page 27
3400753300/AE - Page 27 O ON LINE mode ..................................................................9 Overload ................................................................9-18-20 P Personalization ..............................................................17 Battery ....................................................................17 [...]
-