Power Supply
Whistler 1200
18 pages 0.8 mb -
Power Supply
Whistler 2000
18 pages 0.19 mb -
Power Supply
Whistler PRO-2000W
13 pages 0.61 mb -
Power Supply
Whistler 3000 WATT
18 pages 0.2 mb -
Power Supply
Whistler PRO-3000W
13 pages 0.61 mb -
Power Supply
Whistler PP150AC
16 pages 0.12 mb -
Power Supply
Whistler 800 WATT POWER INVERTER
15 pages 0.16 mb -
Power Supply
Whistler 2000 WATT
18 pages 0.2 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Whistler 800 WATT POWER INVERTER. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Whistler 800 WATT POWER INVERTER ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Whistler 800 WATT POWER INVERTER décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Whistler 800 WATT POWER INVERTER devrait contenir:
- informations sur les caractéristiques techniques du dispositif Whistler 800 WATT POWER INVERTER
- nom du fabricant et année de fabrication Whistler 800 WATT POWER INVERTER
- instructions d'utilisation, de réglage et d’entretien de l'équipement Whistler 800 WATT POWER INVERTER
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Whistler 800 WATT POWER INVERTER ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Whistler 800 WATT POWER INVERTER et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Whistler en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Whistler 800 WATT POWER INVERTER, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Whistler 800 WATT POWER INVERTER, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Whistler 800 WATT POWER INVERTER. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
OWNER’S MANUAL 800 W A TT POWER INVERTER THE WHISTLER GROUP , INC CORPORA TE HEADQUARTERS 13016 N. W alton Blvd. Bentonville, AR 72712 TEL (479) 273-6012 F AX (479) 273-2927 www .whistlergr oup.com CUSTOMER RETURN CENTER 1201 N. Dixieland Rd. Rogers, AR 72756 Consumer Relations T el (800) 531-0004 Email: info@whistlergr oup.com P/N 205563 © 2004[...]
-
Page 2
1 If you have questions concerning the operation of this Whistler product please call consumer relations: 1-800-531-0004 Hours: Monday - Friday 8:00 am - 5:00 pm CT Please keep the receipt in a safe place. Y ou may r egister your product online at www .whistlergr oup.com. If the unit is returned without a dated pr oof of pur- chase, an out of warra[...]
-
Page 3
A Wor d About WHISTLER Inverters. Whistler inverters convert low voltage, direct curr ent (DC) to 110 volt alternating household current (AC). The AC output is called “modified sine wave”. See “T echnical Operating Principles” section for more information. Depending on the model and its rated capacity , Whistler inverters draw power either [...]
-
Page 4
INVERTER BASICS Getting Started Power equipment and appliances which operate with motors or tubes requir e an initial surge of power to get them up and running. This power surge is r eferred to as the "starting load" or "peak load." (By comparison, electrical devices such as standard light bulbs do not r equire a lar ge starting[...]
-
Page 5
INVERTER BASICS Don’t Push It. Although your Whi stle r inverter has the capacity to provide power output (excess current) equal to appr oximately two times its rated wattage capacity for a very brief period, it is designed to operate equipment and appliances with start up load wattage ratings no higher than its own maximum continuous wattage rat[...]
-
Page 6
OPERA TION Making the Connection. This inverter is designed to connect to your 12 volt battery by the supplied #8 gauge cables. 1. Make certain that the inverter’ s rocker switch is in the OFF (O) position. 2. Connect the cables to the power input terminals at the rear of the inverter and tighten the scr ews to make a secure connection. Do not us[...]
-
Page 7
Important Information on Battery Chargers Using your inverter to rechar ge units designed to charge such portable equipment as power tools, flashlights, video cameras and laptop computers may cause damage to the inverter or the charging unit. Check with the appliance manufacturer for compatibility with sine wave inverters if you’re unsur e. Altho[...]
-
Page 8
13 ADDITIONAL FEA TURES Automatic Shut Down & Related Safety Features. Each Whistler inverter model has an unique LED Indicator warning light system which operates in conjunction with the automatic shut down feature . These indicator lights operate as follows: GREEN LED: System ready . RED LED: System overload/automatic shut down. YELLOW LED: O[...]
-
Page 9
2. Low Battery V oltage Alarm/Shutdown Protection a) When the input voltage from the 12 volt power sour ce drops below 10.5 volts, an audible tone will be hear d. This is the low battery voltage alarm. b) The inverter will automatically shut down when the input voltage drops below 9.5 volts. This pr otects the battery from completely draining. In t[...]
-
Page 10
17 16 OPERA TING PRINCIPLES OPERA TING PRINCIPLES assume that the measured waveform will be a pur e sine wave. Consequently , these meters will not read the RMS modified sine wave voltage correctly and, when measuring your Wh is tl er inverter output, the meters will read about 20 to 30 volts too low . T o accurately measure the output voltage of y[...]
-
Page 11
OPERA TION SUMMAR Y 19 OPERA TION SUMMAR Y 18 • This inverter is designed to be connected to the power source with the supplied cables or with #4 wir e up to 12’ - #2 wire for longer length. When utilizing the sup- plied cables do not attempt to modify or lengthen them. • Always make certain that the power cable terminal con- nections run Neg[...]
-
Page 12
21 20 TROUBLESHOOTING TROUBLESHOOTING PROBLEM: Low Battery Alarm On All The Time Problem Solution Input voltage below Keep input voltage above 10.5 volts. 10.5 volts to maintain regulation. Poor or weak battery Replace battery . condition. Inadequate power being Use lower gauge wire. delivered to the inverter or excessive voltage drop. Red LED On P[...]
-
Page 13
SPECIFICA TIONS 23 22 TROUBLESHOOTING WHISTLER 800 WA TT INVERTER SPECIFICA TIONS Maximum Continuous Power .....................800 Watts Maximum Surge Capability (Peak Power) 1600 W atts No Load Current Draw ....................................<0.40 A W aveform ....................................Modified Sine W ave Operating Input V oltage Ran[...]
-
Page 14
W ARRANTY IMPORT ANT : Whistler will not assume responsibility for loss or damage incurred in shipping. Ther efore, please ship your inverter insured with r eturn receipt requested. 2. Include with your unit the following information, clearly printed: • Y our name and street addr ess (for shipping via UPS), a daytime telephone number , (No P .O. [...]
-
Page 15
W ARRANTY Service Out Of W arranty Inverters will be repair ed at “out of warranty” service rates when: • The unit’ s original warranty has expired. • Dated store receipt is not supplied. • The unit has been returned without its serial number . • The unit has been abused, modified, installed improperly , or had its housing removed. Th[...]