BlueWalker PowerWalker VFI 10000P/RT LCD manuale d’uso
- Visualizza on-line o scarica il manuale
- 65 pagine
- N/A
Vai alla pagina of
Manuali d’uso simili
-
Uninterruptible power supply (
BlueWalker VI 1500 PSW
64 pagine -
Uninterruptible power supply (
BlueWalker PowerWalker VFI 2000RT LCD
44 pagine -
Uninterruptible power supply (
BlueWalker PowerWalker VFI 1000 LCD
141 pagine -
Uninterruptible power supply (
BlueWalker PowerWalker VI 850 LCD
7 pagine -
Uninterruptible power supply (
BlueWalker VFI 10000 LCD
56 pagine -
Uninterruptible power supply (
BlueWalker VFI 6000R LCD
141 pagine -
Uninterruptible power supply (
BlueWalker PowerWalker VFI 10000P/RT LCD
65 pagine -
Uninterruptible power supply (
BlueWalker PowerWalker VFI 2000RM LCD
140 pagine
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso BlueWalker PowerWalker VFI 10000P/RT LCD. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica BlueWalker PowerWalker VFI 10000P/RT LCD o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso BlueWalker PowerWalker VFI 10000P/RT LCD descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso BlueWalker PowerWalker VFI 10000P/RT LCD dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo BlueWalker PowerWalker VFI 10000P/RT LCD
- nome del fabbricante e anno di fabbricazione BlueWalker PowerWalker VFI 10000P/RT LCD
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature BlueWalker PowerWalker VFI 10000P/RT LCD
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio BlueWalker PowerWalker VFI 10000P/RT LCD non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti BlueWalker PowerWalker VFI 10000P/RT LCD e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio BlueWalker in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche BlueWalker PowerWalker VFI 10000P/RT LCD, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo BlueWalker PowerWalker VFI 10000P/RT LCD, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso BlueWalker PowerWalker VFI 10000P/RT LCD. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
USER MANU AL On-Line UPS Power Wa lker VFI 6000 RT LCD Power Wa lker VFI 6000 P/RT LCD Power Wa lker VFI 1000 0RT LCD Power Wa lker VFI 1000 0P/RT LCD Unin t erruptible Pow er Supply Sy ste m[...]
-
Pagina 2
Contents 1. Intro ductio n .... ...... ..... ...... ...... ...... ..... ...... ...... ...... ..... ...... ...... ...... ...... .... 1 2. Safety W a rni n g s .... ...... ..... ...... ...... ...... ..... ...... ...... ...... ..... ...... ...... ...... ... 4 2.1 Ins tall a ti on ...... ...... ..... ...... ...... ...... ..... ...... ...... ...... ....[...]
-
Pagina 3
6.2 T rans porti ng the UPS .... ...... ...... ..... ...... ...... ...... ..... ...... ...... ...... ...... 47 6.3 S toring the U PS and Ba tteries ... ...... ...... ..... ...... ...... ...... ..... ...... ...... 48 6.4 T esting Batte ries ..... ...... ...... ..... ...... ...... ...... ..... ...... ...... ...... ..... ...... . 48 6.5 Recyc li ng th[...]
-
Pagina 4
[...]
-
Pagina 5
1 1. Introduct ion Th is Online R/T Series is an uninterruptible p o w e r supply incorporating dou b le-con version techn ology . It p rovide s perfect protection specifically f or computer equipm en t, comm unica tion syst em s to co mputerized inst ru m en ts. It protect s you r sen sitiv e electro nic equipment from b asic po w er proble m s su[...]
-
Pagina 6
2 Figure 1 -2: Online R/T 10K UPS Online R/T UPS a s T ower insta ll a tion. Fig ure 1-3 : Online R /T 6K UPS F i gure 1-4 : O n li ne R/T 1 0K UPS[...]
-
Pagina 7
3 Providing ou tsta nding perf o rmance and reliability , the UPS’ s unique benefit s include: Online UPS design with pure sin e w ave ou tp u t. T rue on l ine double-conversion t echn olog y w ith high po w e r den sity , utility fr e quency i nde p e ndence, and g e nera tor compa tibility . Inte ll igent Ba ttery Man agem en t tec[...]
-
Pagina 8
4 2. Safety Warnings IMPORTANT SAFETY INSTRUC TIO NS FO R EACH S TEP SAVE THESE I N S TRRUCTIO NS. 2.1 Installatio n Cond ensation m ay occur if the UPS is m oved directly f rom a cold to a w arm e nvironment. Th e UPS m ust be a bsolutely dr y before bein g inst alled. Ple a se a llow a n acclim atiza tion tim e of at le ast two hou r s. D[...]
-
Pagina 9
5 the ne utral conducto r sh o uld be prov ide d in the building wiring inst allation. Th is i s per m ane ntly con nected e quipm e nt , it m u st be inst alled by qua l ified m ainte nance personn el. For permanently connec t e d equip m ent: m ake s ure that a read ily accessible disco nn e ct de v ice is incorpora ted in th e building i[...]
-
Pagina 10
6 Ensu r e tha t n o l iquid or oth er f orei g n object s can ente r th e UPS. Th e UPS can b e operate d by any indiv idua l w ithou t previous experience . 2.3 Maintenance, serv i cing and faults Th e U PS operates wi th hazard ous volta g es. Mainte n a nce shou ld be carried o u t o nl y b y qualif ied m ainte nance personn el. [...]
-
Pagina 11
7 5) D o not open or d estro y batt eri e s. Ef f luen t e l e ctrolyte ca n cause injury to the skin and eyes. It m ay be toxic. Please r e place th e fuse onl y w ith the sa m e ty pe an d of the same a m perage in order to av oid fir e hazards. Do not dism antle th e UPS, except the qualified maintenan ce personn el. 2.4 Transpo r t [...]
-
Pagina 12
8 Power-freque ncy Magne tic f ield. ... :IEC/E N 6 1000-4-8 Level 3 Low Freque ncy S ig na l s.. ... ... ... .. .....:IEC/EN 6100 0-2- 2 War n in g: This is a p rodu ct for comm e r cial and i n d ustrial application in the second envir on m ent -inst allation r est r iction s or add itional m ea sures m ay b e nee ded to prev en t disturbance s.[...]
-
Pagina 13
9 3. Inst allati on Th is chapter explains: Equipment inspect ion Unpacking the cabinet Checking th e Accesso r y UPS se tup and i n stallation Conn ecting the i nterna l b at ter y Conn ecting the EBM(Exte nded Ba ttery Module s) Insta ll a tion requirem e nts 3.1 Inspecting the Equipment If any equipment ha s been dama[...]
-
Pagina 14
10 Step 1 : Open t he outer ca r ton a n d remove the accessories o ut of t he carton (see Figure 3-1& 3-2). Online R/T 6K U PS : Figure 3 -1: Unpack ing th e carto n of 6K UP S Online R/T 10 K UPS Figure 3 -2: Unpack ing th e carto n of 10K U PS[...]
-
Pagina 15
11 Step 2 : W i th one p erso n on each side , carefully lift the ca b inet out o f the out er carton u sing the handles o n the cardboard a nd set it on a f lat, stable su r face (se e Fi g ure 3-3&3-4). Place the cabinet in a pr o tected area tha t has ade q uate airf lo w an d is free of humidity, flammable g a s, and corrosion. Lifting th e[...]
-
Pagina 16
12 Figu r e 3-4: Li f t i ng the Cab inet ou t o f 10K UPS carton Step 3 : Discard o r re cycle the packaging in a respon sib le m an ner, or sto re it for futu r e use . 3.3 UPS Rear Panel T his sect i o n s h ows the rea r p an el of the O nline R/T models. 6K m o del: Figure 3 -5: Online R/T 6K R ear Pane l[...]
-
Pagina 17
13 10K model: Figure 3 -6: Online R/T 10K Rear Pane l 3.4 UPS Front Panel Th is section shows the front p an el of the Online R/T UP S. The On li ne series h ave the sam e LCD p a nel a nd the sa m e con trol button. Figure 3 -7: The Online R/T U PS Fron t P an el[...]
-
Pagina 18
14 3.5 Rack m o un t Set u p CAUTION: Th e ca b ine t is heavy, so: 1) Re m ove the b a ttery t r ay f ro m the U P S before li f ting. 2) Lif ting the cab ine ts into th e rack r e q uires a m ini m u m of t w o people. CAUTION: Removing the b a tteries r e quiered precautio ns, w h i ch shou ld b e perform e d o r supervised by p erso nnel w ith [...]
-
Pagina 19
15 3. P ull the batte r y tray o ut using the plastic ta b s and t he n rem ove the b a ttery t ray. Figure 3 -11: Re m ov ing the B attery T r ay 4. I nsta l l the PDU’s e ars to the UP S Figure 3 -12. Inst all the PDU’s ea rs to the U PS 5. S elect the proper holes i n the r a i l for positioning th e ca b ine t in the de sired location in th[...]
-
Pagina 20
16 Figure 3 -13. Inst all the sliding rails 7. Fo r 10K - --Insta ll the batte r y pack and batte ry p rot ection plate, the n replace the front panel. Figure 3 -14. Inst allin g the C abinet 8. For 6K---Replace the battery tra y , and connect the internal battery connecto r , then replace the prote ction p late and the f ront panel. 9. If installi[...]
-
Pagina 21
17 To inst a l l E BMs: 6K Mode l: 1. P l u g th e EBM cable into the UPS batte ry connector Figure 3 -15. Plug t he EB M cab le into the UPS bat tery con nector 2. Re p lace UPS’s front panel a nd EB M’s f ron t panel. Figure 3 -16. Rep l ace UPS’ s fron t p anel and EBM’s f r on t panel .[...]
-
Pagina 22
18 10K Model: Figure 3 -17. Plug t he EB M cab le into the UPS bat tery con nector 3.6 Tower Setup Figu r e 3-18. Tow er se tup CAUTION: Plea se connect the EB M to protective g rou nd w ith 8 AW G wire f o r EBM m ode l f irstly .[...]
-
Pagina 23
19 3.7 Installatio n of UPS with A C inputs CAUTION: Online 6K/10K series support tha t the U PS can have separate AC inputs. So bef ore conne cting wires of seperate AC inputs, y ou should confirm th at the i r earthin g systems are iden tical. Othe r wise, a t r a nsformer is n ecessary . UPS with co mmon Nor m al and Bypa ss AC i n puts UPS with[...]
-
Pagina 24
20 2) T r a nsformer in th e By pass AC input. 3) Both of them ha v e tra nsf or m e r Frequenc y converter ( w ithout Bypa ss AC input)[...]
-
Pagina 25
21 4. Po w er cab les connect ion & St artup Th is section explains: Access to termi n al block C o mm on input so urces conn ection Separate in p ut sources conne ctio n F reque ncy co nv erte r co nnection U PS initial startup Use cable cro ss s ection a nd pr otective device specificat i on Mode l 6K 10K Protec t i ve e a[...]
-
Pagina 26
22 4.1 Access to terminal block Access to terminal block: re m o v e th e 2 screw s o f the terminal block cover Figure 4 -1. PDU of 6K/10K 4.2 Common input sources connection CAUTION: Th is t y p e of connection must be carried out by q ualified ele ctr ical personn el CAUTION: Al w ay s conne ct t he earthing w i r e first[...]
-
Pagina 27
23 Figure 4 -2. Commo n input sou rces con ne ction 4.3 Separat e input so u rces c onnectio n CAUTION: Th is ty p e of co nnectio n must b e carried ou t by qualified electrical personn el. CAUTION: Al w ay s conne ct t he earthing w i r e first. Figure 4 -3. Sepa r at e inpu t sou rces conn ection[...]
-
Pagina 28
24 4.4 Freq u e n c y co n verter connection Figure 4 -4. Freque ncy co nv erter conn ection 4.5 UPS I nitial Startup To st art up t he UPS: Verify tha t the total equipment ratings do not exceed the UP S capacity to prevent an overl o ad alarm. 1. Verify th at the internal bat terties are conn ected. 2. If optiona l EBMs are installed, v eri f y t[...]
-
Pagina 29
25 7. V erify tha t t he UPS is operating norm a l ly and any load is powered. 8. If option al EBMs are insta l led , see “Config ur ing the UPS f o r EBMs” to set the nu m ber o f in stalled EBMs. 9. T o chan g e a ny o t he r facto r y -set default s, see “Operation” Online series recomm e nds sett i n g th e date a n d t i me. At initial[...]
-
Pagina 30
26 2) Users ne ed t o u se a sp e cialty 15-pin co m municatio n cable for this sys tem, w hich shou l d have 15 cores, corresponding stitche s and sh ield, as t h e UPS p arallel cable. The length of the para llel cable is ap p ro pr iate to be less than 3 m. 3) S trictly follow the chapte r o f 4, the w iring re q uire m e nt of single UPS to per[...]
-
Pagina 31
27 Figure 4-5.a : Parallel sy sterm w iring dia gram of 6K/10 K[...]
-
Pagina 32
28 Figure 4-5.b: P arallel Syst em Inst allatio n Diagra m 6) T urn on the input breakers for the tw o p arallel UPS.[...]
-
Pagina 33
29 7) Pressing button continuou sl y for m ore than 1 second for one UPS of the s yst em, th en the s y stem w ill sta r t to turn on and ent er li n e m od e. 8) Regulate the out p ut v oltage of the each UPS separ at ely, and check if the output v olta ge diff e rence b et w een the tw o ups i s less than 0 .5V . If the difference is more tha n 0[...]
-
Pagina 34
30 5) Conn ect the cable and wi re of th e added UPS a cco r din g to the Figure.4-5.a and Figure.4-5.b 6) Switch on the input br e akers a nd m ains brea ker, and m ake sure t hat every UP S w ork in bypass m ode . 7) Switch on the O/P breake r s and m ain O/P b rea ker transfer th e m a in m ainte nan ce switch or sta tic switch fr o m “BPS” [...]
-
Pagina 35
31 5. Operat ion 5.1 Disp l ay Panel Th e UPS ha s a f o ur- butto n graphical LCD with dua l color backlight. Sta ndard back-light is used t o lig ht up the d isplay with w hite text an d a blue b ackg r o und . W he n th e UPS has a cri tica l a larm , the b a cklight chan g e s the text to d ark a m ber an d the b a ckg roun d to red. See Figure[...]
-
Pagina 36
32 Ent er main m en u W he n display ing default UPS st atus summary scr ee n, press this but ton for >1s to e nter th e m ain m en u tree Exit main m en u Press th is b u tton f o r >1s to exit the present m en u to default system st atus display m enu w ith out exe cu tin g a command or chan g ing a se tting Scroll up Press th is b u tton f[...]
-
Pagina 37
33 Afte r p o w erin g on, the LCD w i l l disp lay W elco me logo for sev era l secon ds and then en ter to the defau l t page w hich sh ows the UPS sta tus summary . The display automatically returns to the d ef a ult UPS s t atus summary scr ee n w h en no b ut to n ha s b e en pressed within 1 5 m inut es. On the UPS s t atus s u m mary screen [...]
-
Pagina 38
34 T abl e 5- 3 S tatus Summ ary Screen s S tatus Summary Scree n Desc ription Fig 5-3 Nor m a l m ode : Th e UPS is operating in Nor m al m ode fr o m u tility p ower . Fig 5-4 Battery mode : W he n the UPS is ru nning in batte r y m od e, the buzzer beeps o nce every 4 secon ds. Fig 5-5 By pass with ou tput: Th e UPS does not ha v e th e backu p [...]
-
Pagina 39
35 soft w are (W in p o w e r , etc.). 2) It i s attentio n that t he transfer ti m e of U PS out put from HE mod e to battery mode is a b ou t 10 m s. But it is still too long f or so m e sen sitive load . Fig 5-8 Converter mod e In co nv e rter m o de, th e UPS would free run w ith fixed output fr e q ue ncy (50Hz or 60Hz). Once th e mains is l o[...]
-
Pagina 40
36 Fig 5-1 1 Overload : W he n the UPS is ov e r loa d, the alarm will beep t w ice every second. So m e unn ec e ssary loads should b e get rid of one by one to decrease the l oads conn ected to the UPS . Fig 5-12 Battery T est UPS is e xecuting a bat tery test Fig 5-13 Battery fail: if the batt ery status det ected is “bad battery detected” o[...]
-
Pagina 41
37 4) A fe w seconds later , th e UPS tu r n s i n to Line m ode . If the utility power is abno rm al, the UPS wi ll t r a nsfer to Ba ttery m ode withou t output inte rruption of th e UPS. 5.3 .2 Turning on UPS without ut il ity 1) Check all th e connection is co r rect . 2) Pressing button continuou sl y for m ore than 100ms, the UPS w ou l d be [...]
-
Pagina 42
38 5.4 LC D ope ration Except the de f au lt UPS st atu s summ a r y scree n, the use r could g et m o re useful in form a tion about UPS current sta tus, d e t ailed v arious m ea surement s, pre v ious e v en t record s w h i ch e v er occu r red , UPS own iden tification, a nd cou ld change th e se ttings to fit t he use r o w n requirement s, o[...]
-
Pagina 43
39 Figure . 5- 1 4 Ma i n m en u tree[...]
-
Pagina 44
40 5.4 .2 The UPS status menu By p ressin g on the m e nu of “UPS stat us”, the disp lay w ou ld ent er the next UPS st atus menu t ree. Th e content of UP S sta t us m en u tree is same as th e d ef a ult UPS st atus summary menu. By p ressing >1s, th e display would r et urn the l a st main menu tree. Th e d e t ail information a b ou t ?[...]
-
Pagina 45
41 Figure . 5- 1 5 Eve nt m e nu tree 5.4 .4 The meas urement menu By pressing on the m enu of “Mea surement”, the d isp lay would ent er the next m e asure m ent menu tree. A lot of d eta i led u sef u l information co uld be che cke d he r e, Ex. the out p ut volta g e a nd frequency , th e output current, the load capacity , the input v o l [...]
-
Pagina 46
42 Figure . 5- 1 6 Measu rement menu t ree 5.4 .5 The control menu By p ressin g on the m e nu of “Control”, t he disp lay would e nter the n e xt con trol m en u tre e. 1) S t art Batte r y T e st: this is one command that control t h e UPS t o do th e batte ry test. 2) Clear EPO st atus: once EP O st atus is enabled, t he UPS out p ut w o uld[...]
-
Pagina 47
43 to re set e r ror st atu s, then UPS w o uld stop ala rm and r ec over to By pass m ode . And th e reason of fault should b e checked and dele te d before UPS is t urned on again by m anu al operation . 4) Restore f acto r y settings: all the settings would b e r e cover to defau l t factory sett i n gs. It could o nly be d one in Byp a ss m ode[...]
-
Pagina 48
44 5.4 .6 The identification men u By press on the m enu of “Identification”, the display w ou l d ent er the next identification m en u tree. Th e identification information i n cl u des UPS serial n u mbe r, firmware serial nu m ber , m ode l type, would b e sh ow n here. By press > 1s, th e d i splay would ret u r n the last m ai n m en u[...]
-
Pagina 49
45 poten tial failures or protect ing function loss, even di rectly da m age the load, battery o r UPS . Most o f settings cou ld only be d one w hile U PS is in By pass mode. Figure . 5- 1 9 Sett i ng menu t ree Example: se t rated output volt age value[...]
-
Pagina 50
46 Figure . 5- 2 0 Set r at ed outpu t v olt age va l ue[...]
-
Pagina 51
47 6. UPS Ma intena nce This ch apter explains how t o: Care f or th e UPS an d batteries T ransport the UPS St ore the UPS and batt eries T est the batt eri e s Recy cle the u se d B at te ry or UPS 6.1 UPS and Battery Care For the best pr e v e ntiv e m a inten ance, k eep the ar ea around the UPS clean and dust - free. If th [...]
-
Pagina 52
48 4. Discon nect th e int ernal battery conn ect o r s 5. Re place th e UPS f ront cov e r 6.3 Storing the UPS and Batteries If yo u store t he UPS f or a long period, rech arg e the batt ery every 6 m on ths by co n ne cting t he U P S t o u tility p ower. T h e batteries charge to 90% capacit y in app roxi m ate l y 4 hours. Howev er, it is reco[...]
-
Pagina 53
49 During the battery te st, t h e UPS t r ansfers to Battery m od e and discha r ges the b a tt eries for 2 5% of the original exp ect ed runtim e. Th e sta tus screen d isplays “Batte r y t est runnin g ” and t he p erce ntage of the t est com pleted . The results display on the UPS status screen as co m pleting. 6.5 Recycling the Used Batter[...]
-
Pagina 54
50 7. S pecifications Th is chapter prov ide s the follo w ing s p eci f icatio ns: M od el list General S p ecification Electrical Performan ce Env iron m en tal and Safety 7.1 Electrical sp ec if ica tion Mode l Online R T 6K Online R T 10K Output Powe r Capaci t y 6KV A/5.4K W 10KV A/9K W V oltage Range 208V AC/220V AC/ 230V AC/ [...]
-
Pagina 55
51 Curren t 26.4A @ 230V a c 44.0A @ 230V a c Powe r Factor ≥ 0,99 @100% No minal L oad ≥ 0,98 @50% No minal Lo ad ≥ 0,95 @25% No minal Lo ad THD I < 5 % @ Fu ll load and battery full cha rged Battery & Charg er Battery 180VD C/5Ah 240VD C/9Ah Curren t 39A 48A Charge r c urren t >1A >1.7A 7.2 Dimension and Weight Dimens ion (W*D*[...]
-
Pagina 56
52 8. T roub lesh ooting Th e online series UPS is de si gne d for dura ble, aut om atic o p erat i o n and issues alarm s to alert yo u w hen ev er p ot ent i a l operating proble m s occur. Usually t he alarm s shown by the cont r o l panel do not m ean that the o u tp u t p ower is aff ect ed. In ste ad, they are preventi v e alarms i n tended t[...]
-
Pagina 57
53 Site W i ring F ault Alarm C ode: 04 Site Fau lt detect i on is suppor t e d on a l l m ode ls anyti m e t he re is a Ground ing N eutra l conne cti o n. Alarm t r i ggers whe n the dif f e rence be twee n ground and neutr al voltage is > 15v . Site Fau lt detect i on should be ena bled by de f ault. It can still be enable d / di sab l e d fr[...]
-
Pagina 58
54 Output Overload Alarm C ode:41 Output is overlo ad. Re m ove so m e of the e qui p m e nt fro m t he UPS. The U PS continue s to ope r ate , bu t may sw itch to Byp ass mode or shut down if the loa d incre ase s. The alar m re set s w he n the condit i on beco m e s inactive . Inv Ove rl oa d Fau lt Alarm C ode:42 UPS has transfe r re d to byp a[...]
-
Pagina 59
55 BUS Ove r V oltage Alarm C ode:21 Indica t e s t ha t the UP S ge t BUS ove r volta ge fault be cause of BU S. The U PS transfe rs to Byp ass mode if suppor t in g the loa d BUS Und er V oltage Alarm C ode:22 Indica t e s t ha t the UP S ge t BUS unde r vo l ta ge fault The U PS transfe rs to Byp ass mode if suppor t in g the loa d BUS Unb alanc[...]
-
Pagina 60
56 Paralle l cable lo ss Alarm C ode: E2 In pa rallel sys t e m p ar al l e l c abl e disconn e ct Discon nect par allel cab l e one turn to fault m ode Paralle l syste m battery sta tus Alarm C ode: E6 UPS 1 conne ct ba t te r y UPS 2 wi t hou t batte ry Che ck battery co nne ct status Line inp ut dif f e rent Alarm C ode: E7 Paralle l syste m UPS[...]
-
Pagina 61
57 9. Com m un ication Th is chapter cont ains: C o mm un ication p o rts (RS-232 and USB ) N e twork Mana g e m en t Card (Optiona l ) U PS Management So ftware R EP O 9.1 RS-232 an d USB Comm unication Ports T o es t ablish co mm un ication between the UPS and a comp ut er , con nect your com pute r to one of t he U PS comm unica [...]
-
Pagina 62
58 7 No t use d -- 8 O n B attery signal Out 9 V dc Power +12V Th is p in is conn ected vi a a ju m per to pin 2 of SN MP conn ector Out Figure . 9 -2 R S - 232 Co m mun ication Po rt Figure . 9- 3 Pin1/P i n8 typica l applica t i on Notes: The volta ge of ‘V’ is maxi m u m 3 0VDC, a nd current is m a ximum 45mA.[...]
-
Pagina 63
59 9.2 Network Management Card (Optional) Network Manage m ent C a r d allow th e UPS to communica te with different ty p es of de vi ce s in v a riety of n etw orking e nvir o nments. The Online series has one a v ailable communication bay f or the f ollo w ing conn ectiv ity cards: C onnec t UPS- MS Web/S N MP Card – has S N MP an d HTT P c[...]
-
Pagina 64
60 Install ation procedure: Conn ected b y USB to a PC or not ebook, the Soft w are ena b les communicat i o n betw ee n the U P S a n d t h e com pute r. The UPS softw a r e m on itors the st atu s of the UPS, shut s dow n the sy st em be f ore the U P S is exha usted and can rem ote ly observe the U PS via the N etwork (ena bling users to m an ag[...]
-
Pagina 65
61 614 - 0 1 85 4-00[...]