Lincoln Electric COMMANDER 400 SVM133-B manuale d’uso
- Visualizza on-line o scarica il manuale
- 197 pagine
- 4.96 mb
Vai alla pagina of
Manuali d’uso simili
-
Welder
Lincoln Electric K2704-3
22 pagine 4.56 mb -
Welder
Lincoln Electric IM274-A
140 pagine 4.05 mb -
Welder
Lincoln Electric LN-8
4 pagine 0.19 mb -
Welder
Lincoln Electric POWER WAVE 355M
137 pagine 5.17 mb -
Welder
Lincoln Electric IM604-B
38 pagine 0.82 mb -
Welder
Lincoln Electric WELDANPOWER SVM 113-A
106 pagine 1.15 mb -
Welder
Lincoln Electric IM756-A
32 pagine 0.89 mb -
Welder
Lincoln Electric POWER WAVE IM924
45 pagine 0.92 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Lincoln Electric COMMANDER 400 SVM133-B. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Lincoln Electric COMMANDER 400 SVM133-B o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Lincoln Electric COMMANDER 400 SVM133-B descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Lincoln Electric COMMANDER 400 SVM133-B dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Lincoln Electric COMMANDER 400 SVM133-B
- nome del fabbricante e anno di fabbricazione Lincoln Electric COMMANDER 400 SVM133-B
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Lincoln Electric COMMANDER 400 SVM133-B
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Lincoln Electric COMMANDER 400 SVM133-B non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Lincoln Electric COMMANDER 400 SVM133-B e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Lincoln Electric in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Lincoln Electric COMMANDER 400 SVM133-B, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Lincoln Electric COMMANDER 400 SVM133-B, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Lincoln Electric COMMANDER 400 SVM133-B. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
SVM133-B September , 2002 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be in- creased by proper installation . . . and thoughtful operation on your part. DO NOT INST ALL, OPERA TE OR REP AIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PREC[...]
-
Pagina 2
SAFETY i i COMMANDER 400 FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ______________________[...]
-
Pagina 3
SAFETY ii ii COMMANDER 400 ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Head shield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to pr[...]
-
Pagina 4
COMMANDER 400 FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’s recommendations. 8.c. Ground the equipment in accordance with the U.S. Natio[...]
-
Pagina 5
SAFETY iv iv COMMANDER 400 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L ’Arc 1. Protegez-vous contre la secousse électrique: a.[...]
-
Pagina 6
MASTER T ABLE OF CONTENTS FOR ALL SECTIONS v v COMMANDER 400 Page Safety .................................................................................................................................................i-iv Installation ..................................................................................................................[...]
-
Pagina 7
T ABLE OF CONTENTS - INST ALLA TION SECTION - Section A-1 Section A-1 COMMANDER 400 Installation T echnical Specifications ....................................................................................................... .......A-2 Safety Precautions .............................................................................................[...]
-
Pagina 8
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC A-2 A-2 COMMANDER 400 INST ALLA TION TECHNICAL SPECIFICA TIONS - Commander 400 Make/Model Description Speed (RPM) Displacement Starting Capacities System Deutz 3 cylinder High Id[...]
-
Pagina 9
Read this entire installation section before you start installation. SAFETY PRECAUTIONS Do not attempt to use this equipment until you have thoroughly read all the operation and maintenance manuals supplied with your machine. They include important safety precautions; detailed engine starting, operating and maintenance instructions and parts lists.[...]
-
Pagina 10
LIFTING The Commander 400 weights 1650 lb./748 kg (Stick model); 1683 lb./763 kg. (Stick & Wire model). A lift bail is provided for lifting with a hoist. F ALLING EQUIPMENT can cause injury . Do not lift this machine using lift bail if it is equipped with a heavy accessory such as a trailer . Lift only with equipment of adequate lifting capacit[...]
-
Pagina 11
FUEL NOTE: Use diesel fuel only . Fill the fuel tank with clean, fresh diesel fuel. The capacity of the fuel tank is 25 gallons (94.6 liters). See the Operation and Maintenance sections of this man- ual for more details about fuel. The Commander 400 is protected by a low fuel shutdown to prevent the engine from running out of fuel. The machine will[...]
-
Pagina 12
ELECTRICAL OUTPUT CONNECTIONS See Figure A.1 for the location of the 120 and 240 volt receptacles, weld output terminals, and ground stud. WELDING CABLE CONNECTIONS CABLE INST ALLA TION AND CABLE SIZES With the engine off, route the electrode and work cables through the strain relief bracket on the base and connect to the terminals located on the f[...]
-
Pagina 13
MACHINE GROUNDING Because this portable engine driven welder creates its own power , it is not necessary to connect its frame to an earth ground, unless the machine is connected to premises wiring (home, shop, etc.). T o prevent dangerous electric shock, other equipment powered by this engine driven welder must: a) be grounded to the frame of the w[...]
-
Pagina 14
INST ALLA TION A-8 A-8 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 240 Volt 60 Hz. 3-Wire Service POWER COMPANY METER 240 VOLT 120 VOLT 120 VOLT LOAD N NEUTRAL BUS GROUND PREMISES DISCONNECT AND SERVICE OVERC[...]
-
Pagina 15
Section B-1 Section B-1 COMMANDER 400 T ABLE OF CONTENTS - OPERA TION SECTION - Operation ............................................................................................................................... Section B Safety Instructions ......................................................................................................[...]
-
Pagina 16
OPERA TING INSTRUCTIONS Read and understand this entire section before operat- ing your Commander 400. SAFETY INSTRUCTIONS Do not attempt to use this equipment until you have thoroughly read all the operating and maintenance manuals supplied with your machine. They include important safety precautions; detailed engine starting, operating and mainte[...]
-
Pagina 17
RECOMMENDED APPLICA TIONS WELDER The Commander 400 (Stick model) provides excellent constant current DC welding output for stick (SMA W) welding. The Commander 400 (Stick & Wire model) also provides excellent constant voltage DC welding output for MIG (GMA W) and Inner shield (FCA W) welding. GENERA TOR The Commander 400 provides smooth 120/240[...]
-
Pagina 18
ADDITIONAL DESIGN FEA TURES (Stick & Wire Model only) FOR WIRE WELDING • One constant voltage position for all wire welding. A 12 to 45V range across the entire current output range. • Excellent arc characteristics with MIG (GMAW) and Inner shield (FCA W) welding. • A Wire Feeder connector for quick connection of the control cable. • A [...]
-
Pagina 19
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TION B-5 B-5 COMMANDER 400 FIGURE B.1 – CASE FRONT P ANEL CONTROLS ENGINE CONTROLS (Figure B.1, Items 1 through 8) See Figure B.1 for the location of the following fea- t[...]
-
Pagina 20
OPERA TION B-6 B-6 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 4. ENGINE TEMPERA TURE GAUGE AND LIGHT : The gauge displays the engine oil temperature. The yellow temperature light remains off under normal ope[...]
-
Pagina 21
WELDER CONTROLS ( Figure B.1 Items 9 through 14 ) 9. OUTPUT RANGE SWITCH AND OUTPUT CON- TROL: These two controls allow you to select between various welding output slopes and adjust the desired welding output. Refer to T able B.1 for a description of how these two controls work. T ABLE B.1 OUTPUT RANGE SWITCH AND OUT- PUT CONTROL FUNCTIONS 1 If th[...]
-
Pagina 22
AUXILIAR Y POWER CONTROLS ( Figure B.1 Items 15 - 19 ) 15. 120/240V AC RECEPT ACLE: This is a 120/240V AC (14-50R) receptacle that provides 240V AC or can be split for 120V AC single phase auxiliary power . The receptacle has a 50 amp rating. Refer to “Auxiliary Power Receptacles” in the Installation section for further information about this r[...]
-
Pagina 23
STOPPING THE ENGINE 1. Switch the RUN/STOP switch to “STOP .” This turns off the voltage supplied to the shut down solenoid. A backup shut down can be accomplished by shutting off the fuel valve located on the fuel filter housing. BREAK-IN PERIOD The engine used to supply power for your welder is a heavy duty , industrial engine. It is designed[...]
-
Pagina 24
WELDER OPERA TION STICK WELDING The Commander 400 can be used with a broad range of DC stick electrodes. The OUTPUT RANGE switch provides six overlapping slope controlled current ranges. The OUTPUT CON- TROL adjusts the current from minimum to maximum within each range. Open circuit voltage is also con- trolled by the OUTPUT CONTROL in the slope co[...]
-
Pagina 25
COMMANDER 400 SETTINGS WHEN USING THE K799 HI-FREQ UNIT 1. Set the OUTPUT RANGE switch to the 50-575 setting (Fabrication and General Purpose). 2. Set the IDLER switch to the “HIGH “ position. 3. Set the LOCAL/REMOTE switch to the “REMOTE” position. 4. Set the WELDING TERMINALS switch to the “WELD- ING TERMINALS AL W A YS ON” position. [...]
-
Pagina 26
WIRE FEED (CONST ANT VOL T AGE) WELDING Stick and Wire models only . Connect a wire feeder to the Commander 400 (see the Accessories section) and set the welder controls according to the instruc- tions in “Controls and Settings” in this section of the manual. The Stick and Wire model of the Commander 400, with its CV tap, permits it to be used [...]
-
Pagina 27
T ABLE OF CONTENTS - ACCESSORIES - Accessories ........................................................................................................................... Section C Options/Accessories ...................................................................................................................C-2 Stick Welding ................[...]
-
Pagina 28
OPTIONS/ACCESSORIES The following options/accessories are available for your Commander 400 from your local Lincoln Distributor . K802R Power Plug Kit - Provides a plug for each receptacle. The kit includes 4-120V plugs rated at 15 Amps each and 1-120V/240V Full-KV A plug rated at 50 Amps. K857 28 ft. (8.5 m) or K857-1 100 ft. (30.4 m) Remote Contro[...]
-
Pagina 29
ELECTRIC SHOCK can kill. • Do not operate with panels open. • Disconnect NEGA TIVE (-) BA TTER Y LEAD before servicing. • Do not touch electrically live parts. MOVING P AR TS can injure. • Keep guards in place. • Keep away from moving parts. • Only qualified personnel should install, use or service this equipment. CONNECTION OF THE LN-7[...]
-
Pagina 30
CONNECTION OF THE LN-7 TO THE COMMANDER 400 USING K584 INPUT CABLE ASSEMBL Y (SEE FIGURE C.2.) 1. Shut the welder off. 2. Connect the electrode cable fr om the LN-7 to the “+” terminal of the welder . Connect the work cable to the “CV - Wire” terminal of the welder . NOTE: W elding cable must be sized for current and duty cycle of applicati[...]
-
Pagina 31
ACCESSORIES C-5 C-5 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECTION OF THE LN-8 TO THE COMMANDER 400 USING K867 UNIVERSAL ADAPTER (SEE FIGURE C.3.) 1. Shut the welder off. 2. Connect the electrode cabl[...]
-
Pagina 32
ACCESSORIES C-6 C-6 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECTION OF THE LN-8 TO THE COMMANDER 400 USING K595 INPUT CABLE ASSEMBL Y (SEE FIGURE C.4.) 1. Shut the welder off. 2. Connect the electr ode[...]
-
Pagina 33
CONNECTION OF THE LN-23P TO THE COMMANDER 400 USING K350-1 ADAPTER (SEE FIGURE C.5.) 1. Shut the welder off. 2. Connect the electrode cable from the LN-23P to the “CV - Wire” terminal of the welder . Connect the work cable to the “+” terminal of the welder . NOTE: W elding cable must be sized for current and duty cycle of application. NOTE:[...]
-
Pagina 34
CONNECTION OF THE LN-25 TO THE COMMANDER 400 “ ACROSS THE ARC ” (SEE FIGURE C.6.) 1. Shut the welder off. 2. Connect the electrode cable fr om the LN-25 to the “-” terminal of the welder . Connect the work cable to the “CV -” terminal of the welder . NOTE: W elding cable must be sized for current and duty cycle of application. NOTE: Fig[...]
-
Pagina 35
CONNECTION OF THE K488 SG CONTROL MODULE AND K487 MAGNUM SPOOL GUN TO THE COMMANDER 400 (SEE FIGURE C.7.) 1. Shut the welder off. 2. Connect the electrode cable from the SG Contr ol Module to the “+” terminal of the welder . Connect the work cable to the “CV - Wire” terminal of the welder . NOTE: W elding cable must be sized for current and[...]
-
Pagina 36
NOTES C-10 C-10 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC[...]
-
Pagina 37
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section D-1 Section D-1 COMMANDER 400 T ABLE OF CONTENTS -MAINTENANCE- Maintenance ......................................................................................................................... Section D Safety Precautions ................................[...]
-
Pagina 38
SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • T urn the engine off before working inside the machine. • Remove covers or guards only when necessary to perform maintenance and replace them when the maintenance requiring their removal is complete. • If covers or guards are missing from the machin[...]
-
Pagina 39
CHANGE THE OIL FIL TER: Change the oil filter the first time between 25 and 50 hours of operation. Then, under normal operating conditions, change the oil filter after every 250 hours of operation. If the engine is operated under heavy load or in high ambient temper- atures, change the oil filter more frequently . See T able D.1 for recommended mai[...]
-
Pagina 40
FUEL FIL TERS: When working on the fuel system: • Keep unshielded lights away , do not smoke ! • Do not spill fuel ! The Commander 400 is equipped with a Fuel Pre- Filter/W ater Separator Assembly located before the lift pump and a Secondary Fuel Filter located after the lift pump and before the fuel injectors. The Fuel Pre- Filter/W ater Separ[...]
-
Pagina 41
4. Slide the new element onto the grommet post on the bottom of the filter header until the element no longer easily moves up into the filter header . Now rotate the element (it may take almost 1 full turn) with a slight upward pressure until the element begins to further engage the header . With the prop- er orientation now established, apply addi[...]
-
Pagina 42
BLEEDING THE FUEL SYSTEM: In the event the engine is operated until it runs out of fuel, you will need to bleed the fuel system in order to start the engine. Refer to the engine operation manual. AIR FIL TER: Excessive air filter restriction will result in reduced engine life. The air filter element is a dry cartridge type. It can be cleaned and re[...]
-
Pagina 43
COOLING SYSTEM: The cooling system of the Deutz engine needs to be checked and cleaned periodically . Consult the engine Operation Manual for the proper frequency and procedure. COOLING BLOWER BEL T: The following procedure should be followed to replace the cooling blower belt: 1. Allow the machine to cool. 2. Unfasten and slide the battery holder [...]
-
Pagina 44
MAINTENANCE D-8 D-8 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE D.1 DEUTZ ENGINE MAINTENANCE SCHEDULE FREQUENCY MAINTENANCE REQUIRED Daily or Before Starting Engine • Fill fuel tank. • Check oil le[...]
-
Pagina 45
MAINTENANCE D-9 D-9 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T able D.2 ENGINE MAINTENANCE P ARTS ITEM Air Cleaner Element Cooling Blower Belt Oil Filter Element Fuel Filter Element W ater Separator Elemen[...]
-
Pagina 46
BA TTER Y MAINTENANCE GASES FROM BA TTER Y can explode. • Keep sparks, flame, and cigarettes away from battery . BA TTER Y ACID can burn eyes and skin. • W ear gloves and eye protection and be careful when working near a battery . Follow the instructions printed on the battery . T o prevent EXPLOSION when: • INST ALLING A NEW BA TTER Y - Disc[...]
-
Pagina 47
WELDER/GENERA TOR MAINTENANCE STORAGE: Store the Commander 400 in clean, dry , protected areas. CLEANING: Blow out the generator and controls peri- odically with low pressure air . Do this at least once a week in particularly dirty areas. NAME PLA TES: Whenever routine maintenance is performed on this machine - or at least yearly - inspect all name[...]
-
Pagina 48
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC MAINTENANCE D-12 D-12 COMMANDER 400 FIGURE D.5 - MAJOR COMPONENT LOCA TIONS 1. CASE DOOR ASSEMBL Y 2. ENGINE 3. SHUTDOWN SOLENOID 4. IDLER SOLENOID 5. REAR P ANEL ASSEMBL Y 6. BA[...]
-
Pagina 49
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section E-1 Section E-1 COMMANDER 400 Theory of Operation ............................................................................................................. Section E General Description ....................................................................[...]
-
Pagina 50
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC GENERAL DESCRIPTION The Commander 400 is a diesel engine driven welding power source. The machine uses a brushless asyn- chronous alternating current generator for DC stick elect[...]
-
Pagina 51
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC EXCITER FEEDBACK, CONTROL BOARD, LOCAL AND REMOTE CONTROL The exciter voltage is monitored and fed back through the exciter voltage feedback board to the control board. In the ev[...]
-
Pagina 52
THEOR Y OF OPERA TION E-4 E-4 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC WELD WINDING, OUTPUT BRIDGE, OUTPUT CHOKE AND CV CAP ACI- T ORS The three-phase AC output that is created in the stator weld winding i[...]
-
Pagina 53
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC THEOR Y OF OPERA TION E-5 E-5 Commander 400 FIGURE E.6 – SCR OPERA TION SCR OPERA TION A silicon controlled rectifier (SCR) is a three terminal device used to control rather la[...]
-
Pagina 54
INDUCTION GENERA TORS The Commander 400 utilizes a brushless Asynchronous Induction Generator to convert mechan- ical energy into electrical energy . The following is a brief description of an induction generator . The induction generator is an induction motor driven above the synchronous speed. The rotor conductors pass through the magnetic field [...]
-
Pagina 55
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section F-1 Section F-1 COMMANDER 400 T roubleshooting & Repair Section ................................................................................ Section F How to Use T roubleshooting Guide .................................................................[...]
-
Pagina 56
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC HOW T O USE TROUBLESHOOTING GUIDE Service and repair should be performed by only Lincoln Electric Factory T rained Personnel. Unauthorized repairs performed on this equipment may[...]
-
Pagina 57
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRIC SHOCK can kill. Have an electrician install and service this equipment. T urn the machine OFF before working on equipment. Do not touch electrically hot parts. Sometimes[...]
-
Pagina 58
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-4 F-4 Commander 400 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not[...]
-
Pagina 59
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-5 F-5 COMMANDER 400 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do not[...]
-
Pagina 60
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-6 F-6 Commander 400 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not[...]
-
Pagina 61
No welding output in either CV or stick modes. Also no auxiliary power . Engine operates normally . No auxiliary power at receptacles. The engine operates normally and the welding output is normal. 1. Contact your local Lincoln Authorized Field Service Shop. 1. Check the circuit breakers CB1 thru CB4. Reset if tripped. 2. Check the GFCI receptacles[...]
-
Pagina 62
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-8 F-8 COMMANDER 400 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not[...]
-
Pagina 63
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-9 F-9 Commander 400 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do not[...]
-
Pagina 64
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-10 F-10 COMMANDER 400 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do n[...]
-
Pagina 65
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-11 F-11 COMMANDER 400 TROUBLESHOOTING & REP AIR TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do n[...]
-
Pagina 66
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-12 F-12 COMMANDER 400 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do n[...]
-
Pagina 67
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-13 F-13 COMMANDER 400 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do n[...]
-
Pagina 68
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-14 F-14 The welding arc is “hot”, “spattery”, “cannonballs” or “flares up”. The engine runs normally . The auxil- iary power is no[...]
-
Pagina 69
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-15 F-15 The welding arc is “hot”, “spattery”, “cannonballs” or “flares up”. The engine runs normally . The auxil- iary power is no[...]
-
Pagina 70
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-16 F-16 COMMANDER 400 COMMANDER 400 INITIALIZA TION SEQUENCE AND ERROR CODE EXPLANA TIONS When the Commander 400 is started, the display flashes s[...]
-
Pagina 71
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-17 F-17 COMMANDER 400 WITH G2713-1 CONTROL BOARD ERROR CODES DURING INITIALIZA TION SEQUENCE DEFINITION / SYMPTOM CORRECTIVE ACTION 300 bAd uP 400[...]
-
Pagina 72
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-18 F-18 COMMANDER 400 WITH G2713-1 CONTROL BOARD ERROR CODES DURING INITIALIZA TION SEQUENCE DEFINITION / SYMPTOM CORRECTIVE ACTION CSS or ECL The[...]
-
Pagina 73
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-19 F-19 COMMANDER 400 WITH G2713-1 CONTROL BOARD ERROR CODES DURING INITIALIZA TION SEQUENCE DEFINITION / SYMPTOM CORRECTIVE ACTION LCH Err The ou[...]
-
Pagina 74
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-20 F-20 COMMANDER 400 WITH G2713-1 CONTROL BOARD ERROR CODES DURING INITIALIZA TION SEQUENCE DEFINITION / SYMPTOM CORRECTIVE ACTION Ert Esi EIO EC[...]
-
Pagina 75
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-21 F-21 COMMANDER 400 WITH G2713-2 or -3 CONTROL BOARD ERROR CODES DURING INITIALIZA TION SEQUENCE DEFINITION / SYMPTOM CORRECTIVE ACTION uP bAd u[...]
-
Pagina 76
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-22 F-22 COMMANDER 400 WITH G2713-2 or -3 CONTROL BOARD ERROR CODES DURING INITIALIZA TION SEQUENCE DEFINITION / SYMPTOM CORRECTIVE ACTION SSr EHC [...]
-
Pagina 77
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-23 F-23 COMMANDER 400 WITH G2713-2 or -3 CONTROL BOARD ERROR CODES WHILE RUNNING DEFINITION / SYMPTOM CORRECTIVE ACTION LCH Err The output current[...]
-
Pagina 78
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-24 F-24 COMMANDER 400 WITH G2713-2 or -3 CONTROL BOARD ERROR CODES WHILE RUNNING DEFINITION / SYMPTOM CORRECTIVE ACTION LFL SS? Unit has shut down[...]
-
Pagina 79
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-25 F-25 COMMANDER 400 WITH G2713-2 or -3 CONTROL BOARD ERROR CODES WHILE RUNNING DEFINITION / SYMPTOM CORRECTIVE ACTION Ert Esi EIO ECP ECE EO5 IC[...]
-
Pagina 80
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-26 F-26 COMMANDER 400 WITH G2713-2 OR -3 CONTROL BOARD ERROR CODES WHILE RUNNING DEFINITION / SYMPTOM CORRECTIVE ACTION ECH ECL CSS The exciter vo[...]
-
Pagina 81
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-27 F-27 COMMANDER 400 CASE COVER REMOV AL AND REPLACEMENT PROCEDURE W ARNING Service and repair should be performed by only Lincoln Electric facto[...]
-
Pagina 82
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-28 F-28 COMMANDER 400 CHAIN DOOR ASSEMBL Y FIGURE F .1 – DOOR CHAIN REMOV AL CASE COVER REMOV AL AND REPLACEMENT PROCEDURE (continued) PROCEDURE[...]
-
Pagina 83
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-29 F-29 COMMANDER 400 THREE SCREWS LEFT SIDE P ANEL FIGURE F .2 – DOOR ASSEMBL Y/LEFT SIDE P ANEL SCREW LOCA TIONS 4. Using the 3/8" wrench[...]
-
Pagina 84
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-30 F-30 Commander 400 LEFT SIDE ENGINE COVER P ANEL LOOSEN TWO END SCREWS REMOVE CENTER SCREW FIGURE F .4 – LEFT SIDE ENGINE COVER REMOV AL 6. C[...]
-
Pagina 85
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-31 F-31 COMMANDER 400 FRONT CONTROL P ANEL LOWERED ARROWS INDICA TE SCREW LOCA TIONS FIGURE F .5 – FRONT CONTROL P ANEL REMOV AL FRONT SHROUD RE[...]
-
Pagina 86
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-32 F-32 COMMANDER 400 TROUBLESHOOTING & REP AIR CASE FRONT KNOBS - REMOV AL AND REPLACEMENT PROCEDURE Replacement Removal Flat Rounded Replacement: 1. If the white n[...]
-
Pagina 87
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-33 F-33 COMMANDER 400 W ARNING IDLER SOLENOID TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unau[...]
-
Pagina 88
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-34 F-34 COMMANDER 400 IDLER SOLENOID TEST (continued) FIGURE F .8 – IDLER SOLENOID LEAD TERMINALS PULL-IN COIL (LARGER TERMINALS TOP AND BOTTOM [...]
-
Pagina 89
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-35 F-35 COMMANDER 400 W ARNING SHUTDOWN SOLENOID TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. U[...]
-
Pagina 90
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-36 F-36 COMMANDER 400 SHUTDOWN SOLENOID TEST (continued) FIGURE F .9 - SHUTDOWN SOLENOID LEAD TERMINALS PULL-IN COIL (LARGER TERMINALS EACH SIDE #[...]
-
Pagina 91
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-37 F-37 COMMANDER 400 W ARNING ENGINE THROTTLE ADJUSTMENT TEST Service and repair should be performed by only Lincoln Electric factory trained per[...]
-
Pagina 92
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-38 F-38 COMMANDER 400 ENGINE THROTTLE ADJUSTMENT TEST (continued) FIGURE F .10 - BLOWER P ADDLE MARKED FOR STROBE-T ACH METHOD MARK BLOWER P ADDLE[...]
-
Pagina 93
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-39 F-39 COMMANDER 400 ENGINE THROTTLE ADJUSTMENT TEST (continued) 6. If either of the readings is incorrect, adjust the throttle as follows: Adjus[...]
-
Pagina 94
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-40 F-40 COMMANDER 400 ENGINE THROTTLE ADJUSTMENT TEST (continued) FIGURE F .11 - HIGH IDLE ADJUSTMENT BOSCH 5 7 0 0 8 1 6 903 PES 3A 80D 410/3R 0 [...]
-
Pagina 95
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-41 F-41 COMMANDER 400 W ARNING ST A TIC SCR/DIODE RECTIFIER BRIDGE TEST Service and repair should be performed by only Lincoln Electric factory tr[...]
-
Pagina 96
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-42 F-42 COMMANDER 400 ST A TIC SCR/DIODE RECTIFIER BRIDGE TEST (continued) FIGURE F .13 – CONTROL BOARD PLUG J6 LOCA TION PLUG J6 P e l 9 9 6 TE[...]
-
Pagina 97
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-43 F-43 COMMANDER 400 ST A TIC SCR/DIODE RECTIFIER BRIDGE TEST (continued) FIGURE F .15 – RESISTOR R1 LOCA TION RESISTOR R1 LEAD #204B 6. Using [...]
-
Pagina 98
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-44 F-44 COMMANDER 400 ST A TIC SCR/DIODE RECTIFIER BRIDGE TEST (continued) FIGURE F .16 – HEA T SINK AND SCR TEST POINTS ANODE CA THODE DIODE DD[...]
-
Pagina 99
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-45 F-45 COMMANDER 400 W ARNING ACTIVE SCR TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthor[...]
-
Pagina 100
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-46 F-46 COMMANDER 400 ACTIVE SCR TEST (continued) FIGURE F .17 – CONTROL BOARD PLUG J6 LOCA TION PLUG J6 P e l 9 9 6 TEST PROCEDURE 1. T urn OFF[...]
-
Pagina 101
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-47 F-47 COMMANDER 400 FIGURE F .19 - RESISTOR R1 LOCA TION RESISTOR R1 LEAD #204B ACTIVE SCR TEST (continued) 8. Locate and remove lead #204B from[...]
-
Pagina 102
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-48 F-48 COMMANDER 400 ACTIVE SCR TEST (continued) FIGURE F .21 - SCR TESTER CIRCUIT AND SCR CONNECTIONS T o test SCRs construct the circuit outlin[...]
-
Pagina 103
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-49 F-49 COMMANDER 400 W ARNING CHARGING CIRCUIT TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Un[...]
-
Pagina 104
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-50 F-50 COMMANDER 400 CHARGING CIRCUIT TEST (continued) FIGURE F .22 – ENGINE AL TERNA TOR LOCA TION #239 #238 #285(#281) TEST PROCEDURE 1. T ur[...]
-
Pagina 105
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-51 F-51 COMMANDER 400 W ARNING ST A TOR VOL T AGE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. [...]
-
Pagina 106
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-52 F-52 COMMANDER 400 ST A TOR VOL T AGE TEST (continued) FIGURE F .23 – CONTROL BOX STUD TERMINALS T1 STUD #6 LEADS T2 STUD #5 LEADS T3 STUD #3[...]
-
Pagina 107
TROUBLESHOOTING & REP AIR F-53 F-53 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ST A TOR VOL T AGE TEST (continued) FIGURE F .24 – SCR/DIODE RECTIFIER BRIDGE LEADS COMMANDER 400 STICK an d W IRE STICK a[...]
-
Pagina 108
TROUBLESHOOTING & REP AIR F-54 F-54 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ST A TOR VOL T AGE TEST (continued) FIGURE F .26 – EXCITER LEADS T1, T2, T3 W ARNING T1 T2 T3 TEST PROCEDURE – Exciter W[...]
-
Pagina 109
FINE CONTROL POTENTIOMETER TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety n[...]
-
Pagina 110
TROUBLESHOOTING AND REP AIR FINE CONTROL POTENTIOMETER TEST (continued) F-56 F-56 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TEST PROCEDURE NOTE: In this test procedur e, the positive output stud is used for common. 1.[...]
-
Pagina 111
RANGE SWITCH TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and preca[...]
-
Pagina 112
TROUBLESHOOTING AND REP AIR RANGE SWITCH TEST (continued) Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TEST PROCEDURE NOTE: In this test procedur e, the positive output stud is used for common. 1. Using the 5/16” nut driv[...]
-
Pagina 113
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-59 F-59 RANGE SWITCH TEST (continued) COMMANDER 400 J2 J6 J5 J8 J7 J1 J4 J22 J20 C112 Plug J7 Pin #7 Pin #10 Pin #1 Figure F .28 Control Board Plu[...]
-
Pagina 114
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTES F-60 F-60 COMMANDER 400[...]
-
Pagina 115
SHUNT CALIBRA TION TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes and[...]
-
Pagina 116
TROUBLESHOOTING AND REP AIR SHUNT CALIBRA TION TEST (continued) Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TEST PROCEDURE NOTE: In this test procedur e, the positive output stud is used for common. 1. Using the 5/16” nu[...]
-
Pagina 117
EXCITER VOL T AGE FEEDBACK TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety n[...]
-
Pagina 118
TROUBLESHOOTING AND REP AIR EXCITER VOL T AGE FEEDBACK TEST (continued) Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TEST PROCEDURE 1. Set the machine to the following settings, then start the machine: Control dial to 1 (mi[...]
-
Pagina 119
EXCITER CAP ACITOR BANK TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety note[...]
-
Pagina 120
TROUBLESHOOTING AND REP AIR EXCITER CAP ACITOR BANK TEST (continued) Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Check for voltage across capacitors. V oltages could be high and danger- ous. Discharge capacitors with a hig[...]
-
Pagina 121
CONTROL BOARD POWER SUPPL Y TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety [...]
-
Pagina 122
TROUBLESHOOTING AND REP AIR CONTROL BOARD POWER SUPPL Y TEST (continued) Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TEST PROCEDURE NOTE 1: In this test procedure, the positive output stud is used for common. NOTE 2: This [...]
-
Pagina 123
ST A TOR RESIST ANCE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes a[...]
-
Pagina 124
TROUBLESHOOTING AND REP AIR ST A TOR RESIST ANCE TEST (continued) Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TEST PROCEDURE 1. With the engine off, disconnect the negative bat- tery cable. Make sure that ther e is nothing[...]
-
Pagina 125
TROUBLESHOOTING AND REP AIR ST A TOR RESIST ANCE TEST (continued) Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TEST PROCEDURE 14. Connect the test leads J50 and J51 to the stator winding under test. Close S1 and read the vo[...]
-
Pagina 126
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-72 F-72 COMMANDER 400 This is the typical auxiliary output voltage generated from a properly operating machine. Note that each vertical division r[...]
-
Pagina 127
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-73 F-73 COMMANDER 400 This is the typical DC open circuit out- put voltage generated from a properly operating machine. Note that each vertical di[...]
-
Pagina 128
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-74 F-74 COMMANDER 400 This is the typical DC output voltage generated from a properly operating machine. Note that each vertical division represen[...]
-
Pagina 129
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-75 F-75 COMMANDER 400 This is the typical DC output voltage generated from a properly operating machine. Note that each vertical division represen[...]
-
Pagina 130
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-76 F-76 COMMANDER 400 This is the typical DC open circuit output voltage generated from a properly operating machine. Note that each vertical divi[...]
-
Pagina 131
TROUBLESHOOTING & REP AIR F-77 F-77 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NORMAL SOLENOID PULL & HOLD COIL W A VEFORMS The scope pictures above are typical waveforms seen directly across the pul[...]
-
Pagina 132
TROUBLESHOOTING & REP AIR F-78 F-78 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ABNORMAL SOLENOID PULL & HOLD COIL W A VEFORMS 1V 20 ms 20 ms 200 MV 5 ms The scope pictures above are exam- ples of a s[...]
-
Pagina 133
TROUBLESHOOTING & REP AIR F-79 F-79 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TYPICAL EXCITER VOL T AGE FEEDBACK W A VEFORMS 1 V 2 ms This is the typical waveform output from each of the three phases fr[...]
-
Pagina 134
TROUBLESHOOTING & REP AIR F-80 F-80 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ABNORMAL EXCITER VOL T AGE FEEDBACK W A VEFORMS 1 V 2 ms This is an example of a bad wave- form at one of the Exciter Module[...]
-
Pagina 135
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-81 F-81 COMMANDER 400 W ARNING CONTROL PC BOARD REMOV AL, REPLACEMENT , AND CALIBRA TION Service and repair should be performed by only Lincoln El[...]
-
Pagina 136
TROUBLESHOOTING & REP AIR F-82 F-82 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONTROL PC BOARD REMOV AL AND REPLACEMENT (continued) FIGURE F .33 – MOLEX PLUG REMOV AL CV BOARD MOLEX PLUG CONTROL BOARD[...]
-
Pagina 137
TROUBLESHOOTING & REP AIR F-83 F-83 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONTROL PC BOARD REMOV AL AND REPLACEMENT (continued) FIGURE F .34 – CONTROL BOARD LEADS P e l 9 9 6 B1/227 B2/262 B3/232 [...]
-
Pagina 138
TROUBLESHOOTING & REP AIR F-84 F-84 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONTROL PC BOARD REMOV AL AND REPLACEMENT (continued) CALIBRA TION PROCEDURE (Stick and Wire Model Only) 1. Set the front co[...]
-
Pagina 139
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-85 F-85 COMMANDER 400 W ARNING SHUTDOWN SOLENOID REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory [...]
-
Pagina 140
TROUBLESHOOTING & REP AIR F-86 F-86 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SHUTDOWN SOLENOID REMOV AL AND REPLACEMENT (continued) FIGURE F .35 – SHUTDOWN SOLENOID LEAD CONNECTIONS PULL-IN COIL (LAR[...]
-
Pagina 141
TROUBLESHOOTING & REP AIR F-87 F-87 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SHUTDOWN SOLENOID REMOV AL AND REPLACEMENT (continued) FIGURE F .36 – SHUTDOWN SOLENOID LINKAGE ARM ASSEMBL Y PIVOT PIN SP[...]
-
Pagina 142
NOTES F-88 F-88 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC[...]
-
Pagina 143
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-89 F-89 COMMANDER 400 W ARNING SCR/DIODE RECTIFIER BRIDGE REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric[...]
-
Pagina 144
TROUBLESHOOTING & REP AIR F-90 F-90 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SCR/DIODE RECTIFIER BRIDGE REMOV AL AND REPLACEMENT (continued) FIGURE F .37 – SCR/DIODE RECTIFIER BRIDGE DET AILS #209 (s[...]
-
Pagina 145
TROUBLESHOOTING & REP AIR F-91 F-91 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SCR/DIODE RECTIFIER BRIDGE REMOV AL AND REPLACEMENT (continued) FIGURE F .38 – NEGA TIVE “STICK” OUTPUT TERMINAL #207 [...]
-
Pagina 146
TROUBLESHOOTING & REP AIR F-92 F-92 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SCR/DIODE RECTIFIER BRIDGE REMOV AL AND REPLACEMENT (continued) FIGURE F .40 – RESISTOR R1 LOCA TION RESISTOR R1 LEAD #204[...]
-
Pagina 147
TROUBLESHOOTING & REP AIR F-93 F-93 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SCR/DIODE RECTIFIER BRIDGE REMOV AL AND REPLACEMENT (continued) FIGURE F .42 – SCR/DIODE RECTIFIER BRIDGE ASSEMBL Y REMOV [...]
-
Pagina 148
NOTES F-94 F-94 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC[...]
-
Pagina 149
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-95 F-95 COMMANDER 400 W ARNING SCR REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained person[...]
-
Pagina 150
TROUBLESHOOTING & REP AIR F-96 F-96 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SCR REMOV AL AND REPLACEMENT (continued) FIGURE F .43 – SCR DET AILS SPECIAL INSTRUCTIONS NOTE: Before disassembling the e[...]
-
Pagina 151
TROUBLESHOOTING & REP AIR F-97 F-97 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SCR REMOV AL AND REPLACEMENT (continued) FIGURE F .44 – RECTIFIER BRIDGE ASSEMBL Y BRACKET DET AILS GROMMET BRACKET SCREWS[...]
-
Pagina 152
TROUBLESHOOTING & REP AIR F-98 F-98 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SCR REMOV AL AND REPLACEMENT (continued) FIGURE F .45 – 1/2” WIDE LEAF SPRING 1 1. Go to the procedure below that matche[...]
-
Pagina 153
TROUBLESHOOTING & REP AIR F-99 F-99 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SCR REMOV AL AND REPLACEMENT (continued) CLAMPING PROCEDURE FOR 1/4-28 CAP SCREWS NOTE: This procedure can only be used with[...]
-
Pagina 154
TROUBLESHOOTING & REP AIR F-100 F-100 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SCR REMOV AL AND REPLACEMENT (continued) FIGURE F .47 – HOUSING AND PRESSURE P AD FOR 5/8” WIDE LEAF SPRING PROCEDURE [...]
-
Pagina 155
TROUBLESHOOTING & REP AIR F-101 F-101 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SCR REMOV AL AND REPLACEMENT (continued) CLAMPING PROCEDURE FOR 1/4-28 CAP SCREWS NOTE: This procedure can only be used wi[...]
-
Pagina 156
NOTES F-102 F-102 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC[...]
-
Pagina 157
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-103 F-103 COMMANDER 400 W ARNING MOUNTING OF STUD TYPE DIODES T O ALUMINUM HEA T SINKS Service and repair should be performed by only Lincoln Elec[...]
-
Pagina 158
TROUBLESHOOTING & REP AIR F-104 F-104 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC MOUNTING OF STUD TYPE DIODES T O ALUMINUM HEA T SINKS (continued) PROCEDURE 1. T urn the engine off. 2. Perform the SCR/Di[...]
-
Pagina 159
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-105 F-105 COMMANDER 400 W ARNING ENGINE, ST A TOR/ROT OR REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric [...]
-
Pagina 160
TROUBLESHOOTING & REP AIR F-106 F-106 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE, ST A TOR/ROT OR REMOV AL AND REPLACEMENT (continued) FIGURE F .49 – FUEL T ANK REMOV AL DET AILS FUEL LEVEL SENS[...]
-
Pagina 161
TROUBLESHOOTING & REP AIR F-107 F-107 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE, ST A TOR/ROT OR REMOV AL AND REPLACEMENT (continued) FIGURE F .50 – REAR P ANEL ASSEMBL Y REMOV AL DET AILS BASE[...]
-
Pagina 162
TROUBLESHOOTING & REP AIR F-108 F-108 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE, ST A TOR/ROT OR REMOV AL AND REPLACEMENT (continued) FIGURE F .52 – SHUTDOWN SOLENOID LEAD REMOV AL PULL-IN COIL[...]
-
Pagina 163
TROUBLESHOOTING & REP AIR F-109 F-109 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE, ST A TOR/ROT OR REMOV AL AND REPLACEMENT (continued) FIGURE F .54 – OIL PRESSURE SENSOR LEAD REMOV AL OIL PRESSU[...]
-
Pagina 164
TROUBLESHOOTING & REP AIR F-110 F-110 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE, ST A TOR/ROT OR REMOV AL AND REPLACEMENT (continued) FIGURE F .56 – ENGINE GROUNDING LEAD ENGINE GROUNDING LEAD [...]
-
Pagina 165
TROUBLESHOOTING & REP AIR F-111 F-111 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE, ST A TOR/ROT OR REMOV AL AND REPLACEMENT (continued) FIGURE F .57 – EXCITER BOARD COVER REMOV AL EXCITER BOARD C[...]
-
Pagina 166
TROUBLESHOOTING & REP AIR F-112 F-112 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE, ST A TOR/ROT OR REMOV AL AND REPLACEMENT (continued) FIGURE F .58 – CONTROL BOARD PLUG J2 LOCA TION PLUG J2 P e [...]
-
Pagina 167
TROUBLESHOOTING & REP AIR F-113 F-113 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE, ST A TOR/ROT OR REMOV AL AND REPLACEMENT (continued) FIGURE F .60 – VERTICAL BAFFLE /ENGINE MOUNT REMOV AL CV CA[...]
-
Pagina 168
TROUBLESHOOTING & REP AIR F-114 F-114 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE, ST A TOR/ROT OR REMOV AL AND REPLACEMENT (continued) FIGURE F .61 – ST A TOR REMOV AL Fan Nut Cap Screws (4) Fan[...]
-
Pagina 169
TROUBLESHOOTING & REP AIR F-115 F-115 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE, ST A TOR/ROT OR REMOV AL AND REPLACEMENT (continued) FIGURE F .62 – BLOWER P ADDLE/FLEX PLA TE REMOV AL ROTOR FL[...]
-
Pagina 170
TROUBLESHOOTING & REP AIR F-116 F-116 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE, ST A TOR/ROT OR REMOV AL AND REPLACEMENT (continued) LEAD RECONNECTION CHECKLIST Engine ❒ Engine grounding strap[...]
-
Pagina 171
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-117 F-117 COMMANDER 400 RETEST AFTER REP AIR Retest a machine: • If it is rejected under test for any reason that requires you to remove any mec[...]
-
Pagina 172
NOTES F-118 F-118 COMMANDER 400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC[...]
-
Pagina 173
ELECTRICAL DIAGRAMS G-1 G-1 COMMANDER 400 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Electrical Diagrams Section .......................................................................................... Section G Wiring Diagram - Stick Model (Code 9978) ......................................................[...]
-
Pagina 174
ELECTRICAL DIAGRAMS G-2 G-2 Return to Section TOC Retur n to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-2 COMMANDER 400 WIRING DIAGRAM - STICK MODEL (CODE 9978) 240 uF 240 uF 240 uF S TATO R ASSEMBL Y RECTIFIER SHUNT 600 AMP CHOKE[...]
-
Pagina 175
ELECTRICAL DIAGRAMS G-3 COMMANDER 400 WIRING DIAGRAM - STICK & WIRE MODEL (CODE 9979) 6 230 MAX. 9 50-575 8 400 MAX. 7 270 MAX. 2 WIRE WELDING CV 5 180 MAX. 4 120 MAX. 3 90 MAX. 1 NO FUNCTION L8910 POSITION NAMEPLATE SETTING FROM BACK) (VIEWED S8 216 5 FINE CONTROL 2 4 6 215 208A POT 3 219 214 A NEG. 220 CW CC 77 77B CV 284B 222 BOARD 284 1 CHO[...]
-
Pagina 176
ELECTRICAL DIAGRAMS G-4 COMMANDER 400 WIRING DIAGRAM - STICK MODEL (CODE 10580) 240 uF 240 uF 240 uF STATOR ASSEMBLY RECTIFIER SHUNT 600 AMP CHOKE OUTPUT SCR A SCR B SCR C G1 G2 G3 G1 G2 G3 1 2 3 6 8 2 3 1 2 3 204S 206S 204S 206S 207 SNUBBER PC BOARD 1 2 3 221 220 219 218 217 216 215 214 213 222 1 2 3 4 5 6 7 8 9 10 213 214 215 216 217 218 219 220 [...]
-
Pagina 177
ELECTRICAL DIAGRAMS G-5 COMMANDER 400 WIRING DIAGRAM - STICK & WIRE MODEL (CODE 10581) 6 230 MAX. 9 50-575 8 400 MAX. 7 270 MAX. 2 WIRE WELDING CV 5 180 MAX. 4 120 MAX. 3 90 MAX. 1 NO FUNCTION POSITION NAMEPLATE SETTING FROM BACK) (VIEWED S8 216 5 FINE CONTROL 2 4 6 215 208A POT 3 219 214 A NEG. 220 CW CC 77 77B CV 284B 222 BOARD 284 1 CHOKE 28[...]
-
Pagina 178
ELECTRICAL DIAGRAMS G-6 COMMANDER 400 SCHEMA TIC - AMPHENOL BYP ASS PC BOARD WITH PUBLISHED STANDARDS J61 2 80J 150V TP4 80J 150V TP2 80J 150V TP3 J61 8 J61 1 J61 3 J61 4 J61 5 80J 150V TP1 J61 7 3000V .0047 C1 ON 3 PLACE DECIMALS IS + .OO2 TO MOTHER CONTROL PCB .39mH L3 .39mH L2 TO "OUTPUT CONTROL SOURCE" SWITCH 76C 3000V .0047 C4 3000V [...]
-
Pagina 179
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is pro- vided for reference only . Lincoln Electric discourages board level troub[...]
-
Pagina 180
ELECTRICAL DIAGRAMS G-8 COMMANDER 400 SCHEMA TIC - AUXILIARY PROTECTION PC BOARD XA 12-15-95 G-8 Return to Section TOC Retur n to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTE: This diagram is for reference only . It may not be accurate for all machi[...]
-
Pagina 181
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is pro- vided for reference only . Lincoln Electric discourages board level troub[...]
-
Pagina 182
ELECTRICAL DIAGRAMS G-10 COMMANDER 400 SCHEMA TIC - BYPASS PC BOARD XA 12-15-95 G-10 Return to Section TOC Retur n to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTE: This diagram is for reference only . It may not be accurate for all machines covered [...]
-
Pagina 183
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is pro- vided for reference only . Lincoln Electric discourages board level troub[...]
-
Pagina 184
ELECTRICAL DIAGRAMS G-12 COMMANDER 400 SCHEMA TIC - CONTROL PC BOARD P ART 1 A485 3-27-97B G-12 Return to Section TOC Retur n to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTE: This diagram is for reference only . It may not be accurate for all machin[...]
-
Pagina 185
ELECTRICAL DIAGRAMS G-13 COMMANDER 400 SCHEMA TIC - CONTROL PC BOARD P ART 2 G-13 Return to Section TOC Retur n to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTE: This diagram is for reference only . It may not be accurate for all machines covered by [...]
-
Pagina 186
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is pro- vided for reference only . Lincoln Electric discourages board level troub[...]
-
Pagina 187
ELECTRICAL DIAGRAMS G-15 COMMANDER 400 SCHEMA TIC - CV CONTROL PC BOARD +10v 6.81K R17 6.19K R16 50V 0.1 C3 1.00K R11 J21 5 50V 0.1 C2 J21 2 100 R12 10.0K R15 26.7K R18 28.0K R19 X1 7 6 5 .33mH L1 1W 10V DZ2 10K R13 100 R10 D3 J21 6 X1 14 13 12 15.0K R14 J20 6 J20 7 com com com J20 10 EQUIP. 17741 FILE: M17741_1AE NOT SHOW THE EXACT COMPONENTS OR C[...]
-
Pagina 188
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is pro- vided for reference only . Lincoln Electric discourages board level troub[...]
-
Pagina 189
ELECTRICAL DIAGRAMS G-17 COMMANDER 400 SCHEMA TIC - ENGINE PROTECTION PC BOARD CONTROL LAMP DRIVER +12V BATT. PCB THIS SHEET CONTAINS PROPRIETARY INFORMATION OWNED BY Ch’ge.Sht.No. TO FUEL TO OIL LVL LED LED TO OIL TEMP LED PRESS LED 10 05-12-95 DR. CAPACITORS = EQUIP. TYPE THE LINCOLN ELECTRIC CO. THE LINCOLN ELECTRIC CO. CLEVELAND, OHIO U.S.A. [...]
-
Pagina 190
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is pro- vided for reference only . Lincoln Electric discourages board level troub[...]
-
Pagina 191
ELECTRICAL DIAGRAMS G-19 COMMANDER 400 SCHEMA TIC - METER PC BOARD 7 14 /Q1 CLOCK 1 SET 1 RESET 1 Q1 54HC74 RESET 2 N.C. DATA 1 DATA 2 GND Q2 CLOCK 2 VCC SET 2 X4 10 1 11 4 2 3 6 9 13 12 5 8 X5 13 12 H Q A C Q Q CLK Q Q Q B Q A1 A2 E F G Q R D 74HC164 X1 6 4 2 12 13 1 10 11 8 5 3 9 H Q A C Q Q CLK Q Q Q B Q A1 A2 E F G Q R D 74HC164 X2 6 4 2 12 13 [...]
-
Pagina 192
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is pro- vided for reference only . Lincoln Electric discourages board level troub[...]
-
Pagina 193
ELECTRICAL DIAGRAMS G-21 COMMANDER 400 SCHEMA TIC - REMOTE PROTECTION PC BOARD 5 3000V .0047 C1 J60 4 J60 1 J60 6 J60 3 J60 5 J60 2 J61 3 J61 4 3000V .0047 C3 3000V .0047 C4 J61 1 J61 2 J61 6 J61 7 .39mH L4 .39mH L3 .39mH L5 80J 150V TP2 80J 150V TP3 80J 150V TP1 80J 150V TP4 J61 8 J61 5 3000V .0047 C5 .39mH L1 .39mH L2 FRAME FRAME FRAME FRAME FRAM[...]
-
Pagina 194
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is pro- vided for reference only . Lincoln Electric discourages board level troub[...]
-
Pagina 195
ELECTRICAL DIAGRAMS G-23 COMMANDER 400 SCHEMA TIC - SNUBBER PC BOARD 1-16-98E G-23 Return to Section TOC Retur n to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTE: This diagram is for reference only . It may not be accurate for all machines covered by[...]
-
Pagina 196
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is pro- vided for reference only . Lincoln Electric discourages board level troub[...]
-
Pagina 197
SVM ERROR REPORTING FORM We need to know if there are errors in our manuals. W e also value any suggestions as to additional tests or procedures that would make this SVM a better tool for you. If you discover new or different “Problems or Symptoms” that are not covered in the three col- umn troubleshooting chart, please share this information w[...]