SPX Cooling Technologies Marley MH Fluid Cooler manuale d’uso
- Visualizza on-line o scarica il manuale
- 36 pagine
- 0.8 mb
Vai alla pagina of
Manuali d’uso simili
-
Humidifier
SPX Cooling Technologies Atmospheric Heat Vaporization Systems
8 pagine 0.88 mb -
Humidifier
SPX Cooling Technologies Marley MH Marley MH Fluid Cooler
36 pagine 0.84 mb -
Humidifier
SPX Cooling Technologies Marley NC Class
8 pagine 1.18 mb -
Humidifier
SPX Cooling Technologies 1200
32 pagine 1.58 mb -
Humidifier
SPX Cooling Technologies F400
8 pagine 1.18 mb -
Humidifier
SPX Cooling Technologies W400
4 pagine 0.46 mb -
Humidifier
SPX Cooling Technologies 7013F081 - 7013J121
28 pagine 0.86 mb -
Humidifier
SPX Cooling Technologies Air Cooled Condensers
4 pagine 0.69 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso SPX Cooling Technologies Marley MH Fluid Cooler. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica SPX Cooling Technologies Marley MH Fluid Cooler o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso SPX Cooling Technologies Marley MH Fluid Cooler descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso SPX Cooling Technologies Marley MH Fluid Cooler dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo SPX Cooling Technologies Marley MH Fluid Cooler
- nome del fabbricante e anno di fabbricazione SPX Cooling Technologies Marley MH Fluid Cooler
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature SPX Cooling Technologies Marley MH Fluid Cooler
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio SPX Cooling Technologies Marley MH Fluid Cooler non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti SPX Cooling Technologies Marley MH Fluid Cooler e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio SPX Cooling Technologies in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche SPX Cooling Technologies Marley MH Fluid Cooler, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo SPX Cooling Technologies Marley MH Fluid Cooler, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso SPX Cooling Technologies Marley MH Fluid Cooler. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
>ViÊ N Ê>ÊÀ ÞÊ}Ê N Ê>ÀiÞ }Ê / i V }i à / Marley MH Fluid Cooler / Us er Manu al 05- 116 D[...]
-
Pagina 2
[...]
-
Pagina 3
3 Contents Fluid Cooler Location ............................................................................. 5 Fluid Cooler Shipment ............................................................................ 6 Receiving Fluid Cooler ........................................................................... 6 Hoisting Fluid Cooler .............[...]
-
Pagina 4
4 Preparation The Marley MH Fluid Cooler with CoolBoost™, purchased for this instal- lation repr esents the current state of the art in crossflow , induced draft fluid cooler design. Thermally and operationally , it is the most efficient fluid cooler of its class. These instructions—as well as those offered separately on motors, fans, Geare[...]
-
Pagina 5
5 Preparation It is not in tend ed no r as sume d tha t ac cess to the fa n deck on sin gle- flow models—Models MHF702 thru MHF705—is needed or necessary . Those are only some of the safety issues that may arise in the design process. SPX strongly recommends that you consult a safety engineer to be sure that all safety considerations have been[...]
-
Pagina 6
6 The fluid cooler must be located at such distance and direction to avoid the possibility of contaminated fluid cooler discharge air be- ing drawn into building fresh air intake ducts. The purchaser should obtain the ser vices of a Licensed Professional Engineer or Registered Architect to certify that the location of the fluid cooler is in comp[...]
-
Pagina 7
7 Hoisting clips are provided for ease of unloading and positioning the fluid cooler . For overhead lifts or where additional safety is required, safety slings should also be placed under the fluid cooler modules. Under no circumstances should you combine the top and bottom modules of modular models and attempt to hoist them at the same time by u[...]
-
Pagina 8
8 Fasteners and components provided by others that are to be at- tached to the tower must be compatible with the cooling tower materials—i.e. fasteners in a stainless steel cold water basin must be stainless steel. 6. Attach pr ocess fluid supply and return piping to the coil. Field piping connection is an NPT male connection at the coil. A weld[...]
-
Pagina 9
9 • Do not start the motor more than six times per hour . Short cycling the tower will cause fuses, breakers or O.L.s to operate and will decrease motor life. When using a two-speed starter: • Motor rotation must be the same at slow speed and high speed. • Single winding motor requir es a starter with a shorting contactor . • T wo-winding m[...]
-
Pagina 10
10 equipment. Electrical savings can be lar ge during periods of low ambient temperature when the cooling requirement can be satisfied at reduced speeds. T o benefit from these advantages, it is important that the drive be installed correctly . Marley supplies VFD and VFD controls specifically designed for our cooling products. If you have pur c[...]
-
Pagina 11
11 Mechanical Equipment: The fluid cooler is designed to operate at full speed and half speed. W arranty is void if the tower is operated at speeds which cause damaging vibrations to the tower and associated equipment. When utilizing a variable frequency drive, the tower must be tested across the full range of speeds and checked against CTI guidel[...]
-
Pagina 12
12 It is essential that the fan cylinder and fan guard be installed in ac- cordance with the drawings shipped with the tower . Do not force the fan cylinder out of round. 4. Momentarily bump (energize) the motor(s) and observe rotation of the fan(s). If rotation is backwards, shut off the fan and r everse two of the three primary leads supplying po[...]
-
Pagina 13
13 Fluid Cooler Start-Up Amon g other sou rces, out breaks of Legio nnaire s’ Diseas e have repo rt- edly been traced to cooling towers and fluid coolers. Maintenance and wate r treatme nt proced ures that prev ent ampli fication and dis semina - tion of Legionella and other airborne bacteria should be formulated and implemented BEFORE systems [...]
-
Pagina 14
14 7. While operating the recir culating water pump(s) and prior to operat- ing the cooling tower fan, execute one of the two alter native biocidal treatment pr ograms described in the following: • Resume tr eatment with the biocide which had been used prior to shutdown. Utilize the services of the water treatment supplier . Maintain the maximum [...]
-
Pagina 15
15 Fluid Cooler Operation General: The cold process fluid temperature obtained from an operating fluid cooler will vary with the following influences: 1. Heat load: With the fan in full operation, if the heat load increases, the cold process fluid temperature will rise. If the heat load reduces, the cold process fluid temperatur e will reduce.[...]
-
Pagina 16
16 4. Air flow rate: Reducing air flow throug h the fluid cooler causes the cold process fluid temperature to rise. This is the r ecommended method by which to control leaving pr ocess fluid temperature. If your fluid cooler is equipped with a single-speed motor , the motor may be shut of f when the process fluid temperature becomes too cold[...]
-
Pagina 17
17 Slushy , transitory ice forms routinely in the colder regions of the fill of low temperature towers, and is visible through the tower louvers. Such ice normally has no adverse effect on fluid cooler operation, but its appearance should be a signal to the operator to undertake ice control procedures. It is the operator's responsibility to [...]
-
Pagina 18
18 Reversal may be at either full or half speed; however , reversal at half speed is recommended. Reverse operation of the fan should be used sparingly and should only be used to control ice, not to prevent it. R e ve rs e fa n op er at io n sh ou ld no t ne ed to ex ce ed 1 or 2 mi nu te s . Mo ni to r - i n g is r e qu ir ed t o de te rm in e th [...]
-
Pagina 19
19 When the use of industrial antifreeze solutions is not possible, the system must be operated to meet both of the following conditions. 1. Maintain sufficient flow rate through the coil. 2. Maintain sufficient heat load on the process fluid. Fluid exiting the coil must be maintained at or above 45°F . Cycling of the r ecirculation pump shoul[...]
-
Pagina 20
20 W ater T reatment and Blowdown Maintaining W ater Quality: The steel used in MH Fluid Cooler's has been galvanized with a heavy zinc coating averaging 2.0 mils in thickness. Other materials used (PVC fill, drift eliminators, and louvers, aluminum fans, cast iron Geareducer , etc.) are selected to of fer maximum service life in a “normal?[...]
-
Pagina 21
21 Fluid Cooler Cleaning: Any evaporative-type fluid cooler must be thoroughly cleaned on a regular basis to minimize the growth of bacteria, including Legionella Pneumophila, to avoid the risk of sickness or death. Service personnel must wear proper personal protective equipment during decontami- nation. Do NOT attempt any ser vice unless the fan[...]
-
Pagina 22
22 (percent of flow) required to maintain different concentrations with various cooling ranges*: * Range = Differ ence between hot water temperature and cold water temperature. EXAMPLE: 700 GPM circulating rate, 18°F cooling range. T o maintain 4 concentrations, the required blowdown is 0.458% or .00458 times 700 GPM, which is 3.2 GPM. If fluid [...]
-
Pagina 23
23 Maintenance See Figure 3 for MH Fluid Cooler models MHF706 and MHF707.The belts are adjusted by turning the threaded rod. Before tightening or loosening the belt, the double nuts holding the motor support in place must be loosened. There ar e two jam nuts at the end of the rod next to the casing. T ur n the nut closest to the end of the rod to t[...]
-
Pagina 24
24 Maintenance sion is the lowest tension at which the belt will not slip under peak load conditions. Check tension frequently during the first 24-48 hours of run-in operation. Overtensioning shortens belt and bearing life. Keep belts free from foreign material which may cause slipping. Never apply belt dress- ing as this will damage the belt and [...]
-
Pagina 25
25 Fluid Cooler Maintenance Some maintenance procedur es may require maintenance personnel to enter the fluid cooler . Each cased face of the fluid cooler has a door for access to the interior of the tower . The optional fan deck ladder—models MHF706 and MHF707— is de- signed and intended solely for personnel to gain access to the fan deck. T[...]
-
Pagina 26
26 W eekly: Inspect for bacterial growth and general operation conditions. Bacterial growth should be reported to your water treatment expert for immediate attention. Monthly (W eekly at start up): Observe, touch, and listen to the fluid cooler . Become accustomed to its normal appearance, sound, and level of vibration. Abnormal aspects relating t[...]
-
Pagina 27
27 additional cleaning. Refer to “Fluid Cooler Cleaning” section—page 21. Consult your water treatment expert as to prudent biological evaluation testing. Geareducer models used on MH Fluid Coolers are designed for 5-year oil change inter vals. T o maintain five-year change intervals, use only oil designed specifically for these Geareducers[...]
-
Pagina 28
28 3. Insert grease fittings in grease fill openings and add grease until grease is forced out thr ough relief openings. 4. Replace fill plugs and operate mechanical equipment 30 minutes to one hour to pur ge excess grease at grease r elief opening. 5. Reinstall grease r elief plugs and reinstall guard. 6. Resume normal fluid cooler operation. [...]
-
Pagina 29
29 has remained effective. Unless there is evidence of a generalized failure of the galvanizing, localized touch-up should be all that is requir ed. T o the extent that the galvanizing (zinc coating) still exists, paint will not adhere to it readily . Contact the manufacturer of the coating you intend to use for instructions. Fluid cooler framework[...]
-
Pagina 30
30 SPX Cooling T echnologies Services Our interest in your MH Fluid Cooler does not end with the sale. Having conceived, designed, and manufactured the most r eliable and longest- lasting fluid cooler of its class, we want to make sure that you gain the maximum possible benefit from its pur chase. Therefor e, the following services ar e available[...]
-
Pagina 31
31 Maintenance Schedule Maintenance Service Monthly Semi-annually Seasonal Startup or Annually Inspect General Condition and Operation x x Observe Operation of: Mechanical–motor , fan and drive mechanism x x Makeup valve (if equipped) x x Inspect for unusual noise or vibration x x Inspect and Clean: Air inlet x x PVC drift eliminators x x Distrib[...]
-
Pagina 32
32 Troubleshooting T rouble Cause Remedy Motor will not start Power not available at motor terminals Check power at starter . Correct any bad connections between the control apparatus and the motor . Check starter contacts and control cir cuit. Reset overloads, close contacts, reset tripped switches or r eplace failed control switches. If power is [...]
-
Pagina 33
33 Troubleshooting T rouble Cause Remedy Geareducer noise. (If equipped). Geareducer bearings If new , see if noise disappears after one week of operation. Drain flush, and refill Gear educer oil. See Geareducer User Manual. If still noisy , replace. Gears Correct tooth engagement. Replace badly worn gears. Replace gears with broken or damaged te[...]
-
Pagina 34
34 Increased load requirements: MH Fluid Coolers are designed so that cells of either equal or unequal capacity can be added in the futur e. This allows you to compensate for the load increases that normally occur with the replacement or addition of production equipment—and still retain continuity with respect to your fluid cooler system. Fluid [...]
-
Pagina 35
[...]
-
Pagina 36
Manual 05-116D / 7401 W 129 Street // Overland Park, KS USA 66213 // +1 913 664 7400 // spxcooling@ct.spx.com // spxcooling.com / In the interest of technological progress, all products are subject to design and/or material change without notice. ©2007 SPX Cooling T echnologies, Inc. | Printed in USA Balcke | Hamon Dr y Cooling | Marl ey Cooli ng [...]