ACR Electronics ARX-50 manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of ACR Electronics ARX-50, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ACR Electronics ARX-50 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of ACR Electronics ARX-50. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of ACR Electronics ARX-50 should contain:
- informations concerning technical data of ACR Electronics ARX-50
- name of the manufacturer and a year of construction of the ACR Electronics ARX-50 item
- rules of operation, control and maintenance of the ACR Electronics ARX-50 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ACR Electronics ARX-50 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ACR Electronics ARX-50, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ACR Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ACR Electronics ARX-50.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the ACR Electronics ARX-50 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Y1 - 03 -022 9C i[...]

  • Page 2

    Y1 - 03 -022 9C 1 CAUTION: B efore proceedin g to install, tes t or us e your ne w ACR Elec troni cs’ product, p lease read this Pro duct Support Manual in its entiret y. If y ou ha ve ques tions r egarding the co ntents of the m anual, pleas e contact our Technica l Service Departm ent at ACR E lectronics, Inc., Telephone +1 (954) 98 1-3333. Ple[...]

  • Page 3

    Y1 - 03 -022 9C 2 Table of Cont ents SECTION 1 - HOW THE ARX-50 WORKS _________________________ 2 SECTION 2 - PREPARING TO INSTALL ___________________________ 3 SECTION 3 - INSTALLATION ___________________________________ 5 SECTION 4 - OPERATION _____________________________________ 6 SECTION 5 - MAINTENANCE __________________________________ 9 APP[...]

  • Page 4

    Y1 - 03 -022 9C 3 SECTION 1 - HOW THE ARX-50 WORKS T he ARX-50 alarm receiver is designed as a com panion to the ACR r adio beacon transm itter m odel num ber RBL-30 (Mini B™ 300 ). It is intended to be used in a crew overbo ard (COB) al erting application . W hen proper ly powered and fitted with an externa l antenna, the signals from the Mini B[...]

  • Page 5

    Y1 - 03 -022 9C 4 Controls and indicators On/Off sw itch I/O cable Mounting bracket Speaker location Mode swit ch Frequency selector switch Coaxial (BNC) connector Alarm indicator Signal strength meter Weather resistant polycarbonate housing[...]

  • Page 6

    Y1 - 03 -022 9C 5 Location selection Choose a dry, clean surf ace to install th e ARX -50, giving cons ideration to the importance of the location. The us er m ust be ab le to see the v isual alarm and hear th e audible alarm . CAUTION: W hen using the included antenna, the ARX -50 must be mounted vert ically and the antenna m ust not be within 0.5[...]

  • Page 7

    Y1 - 03 -022 9C 6 Connect the pow er supply The ship’s power su pply is the source of po wer for the ARX -50. A one- meter I/O c able is supplied with the product. It is recomm ended that a qu alified m arine electronics prof essional or qualified electrician con nect the po wer. Wiring The 1m I/O cable wiring chart is as fol lows: Signal Wire Co[...]

  • Page 8

    Y1 - 03 -022 9C 7 The ARX-50 has three lar ge, c ircular push buttons and seven LEDs that indicate set tings. The push buttons switch b etween a lternate modes. Each button is assigned a s et o f functions. See Figure 1. Each button “ beeps” when depressed. T he LED indicators are e ither red or green to signif y th e system m ode. Green LEDs s[...]

  • Page 9

    Y1 - 03 -022 9C 8 Monitor Low m ode This m ode is identical to t he Monit or High mode except that the sp eaker volume is lower. NOTE: The ARX-50 reverts back to Alarm m ode af ter 15 m inutes in Monitor High m ode. Training mode Operation in Train ing mode is ide ntical to the live r adio beacon d etection mode. In Training m ode, the ARX -50 rece[...]

  • Page 10

    Y1 - 03 -022 9C 9 SECTION 5 - MAINTENANCE The following m aintenance s chedule is recomm ended: Action Description Frequency Visual inspection Inspect the antenna, cables and connections. Ensure that the cable is attached properly and the unit has not been damaged. Every 6 months Performance test Verify that the s ystem is operating b y using the t[...]

  • Page 11

    Y1 - 03 -022 9C 10 A P PENDIX B - ACCESSORIES The following are item s that can be ordered f or your alarm receiver: Description ACR Part Number Mini B™ 300 ILS H 2 ON (wat er activated) 2767 Mini B™ 300 ILS (m anually activated) 2766.6 A P PENDIX C - W ARRA NTY, USEFUL LIFE P OLICY, NOTICES Limited Warrant y This product is w arrant ed against[...]

  • Page 12

    Y1 - 03 -022 9C 11 FCC Compliance Statement NOTE: T his equipment has been tested and f ound to comply with the limits for a Class B digital device, pursua nt to part 15 of the FCC Rules. T hese lim its are designed to provide r easonable protect ion aga inst harmful interference in a residentia l installatio n. This equipment generates, uses nd ca[...]

  • Page 13

    Y1 - 03 -022 9C 12 E C DE C LA RA T IO N OF CO N FO R MIT Y AC R El ec tr o ni c s, I n c. he r eby d ec la r es th at th e fo ll ow i ng pr o duc t is in co nf or m it y w i th Di re c ti ve 19 99 / 5/ EC of th e E ur o pe an Pa rl i am en t an d of th e Co un c il of 9 M ar ch 19 99 on Ra d io Eq ui p me nt an d Te le co m mu ni ca t io ns Te r m[...]