Go to page of
Similar user manuals
-
Marine Safety Devices
ACR Electronics 2883
22 pages 0.86 mb -
Marine Safety Devices
ACR Electronics ARX-50
13 pages 0.48 mb -
Marine Safety Devices
ACR Electronics RLB-37
31 pages 1.62 mb -
Marine Safety Devices
ACR Electronics HRU-100
18 pages 0.79 mb -
Marine Safety Devices
ACR Electronics PLB-350B
22 pages 0.86 mb -
Marine Safety Devices
ACR Electronics 9490
18 pages 0.79 mb -
Marine Safety Devices
ACR Electronics GlobalFix 2842
31 pages 0.25 mb -
Marine Safety Devices
ACR Electronics 2882
22 pages 0.86 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of ACR Electronics HRU-100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ACR Electronics HRU-100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of ACR Electronics HRU-100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of ACR Electronics HRU-100 should contain:
- informations concerning technical data of ACR Electronics HRU-100
- name of the manufacturer and a year of construction of the ACR Electronics HRU-100 item
- rules of operation, control and maintenance of the ACR Electronics HRU-100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ACR Electronics HRU-100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ACR Electronics HRU-100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ACR Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ACR Electronics HRU-100.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the ACR Electronics HRU-100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
[...]
-
Page 2
Y1 -06-020 9G 1 CAUTION: Before proc eeding to install, test or use your new ACR Electronics’ product, please read this P roduct Support Manual in its entirety. If y ou have questions regarding the contents of the m anual, please contact o ur T echnical Service Departm ent at ACR Electronics, Inc., Telephone +1 (954) 98 1- 3333. Please be ready t[...]
-
Page 3
Y1 -06-020 9G 2 Table of Contents SECTION 1 – INTRODUCTION _______________________________ 3 SECTION 2 – PREPARING TO INSTALL ________________________ 4 SECTION 3 – HOW TO DETERMINE HRU EXPIRATION DATE _______ 6 SECTION 4 – INSTALLING THE HRU IN A SeaShelter 3 ™ BRACKET ___ 7 SECTION 5 – INSTALLING THE HRU IN A SeaShelter 2 ™ BRACKET [...]
-
Page 4
Y1 -06-020 9G 3 SECTION 1 – INTRODUCTION Congratulations and thank you for purchas ing the ACR H ydroFix™ Hydrostatic Release Unit ( HRU) replacem ent for your ACR Category I EPIRB. ACR des igns, manufactures and distrib utes quality products k nowing they are use d t o s ave lives. Man y of our products are required to be tested and approve d [...]
-
Page 5
Y1 -06-020 9G 4 SECTION 2 – PREPARING TO INSTALL UNPACKING T HE HydroFix ™ HR U The HydroFix™ HRU Kit is a universal k it in that i t is used for all Category I ACR EPIRBs. T he k it c omponents that are required to replace t he HR U in a particular m odel will var y wit h t he E PIRB brack et you are servicing. The content of the universal H[...]
-
Page 6
Y1 -06-020 9G 5 If any of the above is missing, please contact ACR E lectronics’ Technical Service b y em ail at service @acrelectronics, com or by phone at +1 (954) 98 1- 33 3 3. Equipment that m a y be req uired but is not included: // Black indelible m arker // Phillips-head scr ewdriver // Flat-head scre wdriver // Pliers Notes, Caut ions and[...]
-
Page 7
Y1 -06-020 9G 6 SECTION 3 – HOW TO DETERMINE HRU EXPIR ATION DATE The ACR HydroFix ™ HR U is a replace able part and, as such, has dating associated with it. T he HRU must be replac ed tw o (2) years from the install date or f our ( 4) years f rom t he d ate of man ufacture, whichev er is less. The HRU has a ca lendar on its top s ide ; the cal[...]
-
Page 8
Y1 -06-020 9G 7 SECTION 4 – INST ALLING THE HRU IN A SeaS helter 3 ™ BRACKET The following ACR EPIRBs are com patible with the Se aShelter 3 ™ (ACR P/N 9501): GlobalFix™ iPRO, or m odels RLB -36 and higher Contents of the H ydroFix™ HRU Kit that you will need: HydroFix ™ Repl acement Hydrostatic Release Un it (E) Large cotter p in (H) H[...]
-
Page 9
Y1 -06-020 9G 8 11.) Reinst all the beacon with the lanyard facing toward the bac k of the bracket. 12.) Place the brack et top co ver on to p of the bottom cover . 13.) Mak e sure the bottom hinge and th e top handle are secure ly connected. 14.) Place HRU exp iration lab el (K) on th e outside of y our bracket in a visible location. Figure B[...]
-
Page 10
Y1 -06-020 9G 9 SECTION 5 – INST ALLING THE HRU IN A SeaS helter 2 ™ BRACKET The following ACR EPIRBs are com patible with the SeaShelter 2 ™ (AC R P/N 943 5/9455): GlobalFix ™ 40 6 RapidFix ™ 406 SATELLITE 2 406 ™ SATELLITE 406 ™ (discontinued product) Contents of the H ydroFix™ HRU Kit that you will need: HydroFix ™ Repl acement[...]
-
Page 11
Y1 -06-020 9G 10 8.) Push the rele ase spring back against the brack et aligning the hol es on th e s pring with the hol es on the back of the bracket. 9.) T ake the ass embled HR U and p lace th e washer e nd of the HRU through the l arger top h ole and slid e down into the sm aller slot. 10.) T urn the HRU to the l eft side of the brack et (s ee [...]
-
Page 12
Y1 -06-020 9G 11 SECTION 6 – INST ALLING THE HRU IN A Sea Shelter ™ BRACKET The ACR SeaShelter ™ is a discont inued product that look s like this: Contents of the H ydroFix™ HRU Kit that you will need: HydroFix ™ Repl acement Hydrostatic Re lease Unit (E) SeaShelter ™ rel ease rod ( A) Keyed brack et adapter (D) Large cotter p in (H) HR[...]
-
Page 13
Y1 -06-020 9G 12 5.) Place ke yed br acket adapter (D) on the bottom of the HRU. T his part is k eyed so that it will fit to gether onl y one wa y. Turn to the right until it snaps i nto place. 6.) M ark the expir y date on the HRU according to the instructi ons i n Section 3. 7.) Record the ex piration da te on th e HRU expiration label ( K) with [...]
-
Page 14
Y1 -06-020 9G 13 SECTION 7 – INSTALLING THE HRU IN AN OPEN FACED BRACKET The ACR open faced bracket is a discontinued product that look s like this: Contents of the H ydroFix™ HRU Kit that you will need: HydroFix ™ Repl acement Hydrostatic Release u nit (E ) Open faced re lease rod (C) 2 Mounting brac ket adapter s (J ) Mounting rod ad apter,[...]
-
Page 15
Y1 -06-020 9G 14 6.) Record th e expiration date on the HRU expiration label (K) with a n indelible mark er. 7.) Slide the m etal m ounting r od adapter ( L) onto top of HRU unit. Place the HRU rel ease r od (C) into the mounting r od adapter, aligning the holes. 8.) W ith pliers, insert s lotted spring pin (I) into t he aligned hol es, securing th[...]
-
Page 16
Y1 -06-020 9G 15 SECTION 8 – INSTALLING THE HRU IN A CAPSULE BRACKET The ACR capsule bracket is a discontinued product that look s like this: Contents of the H ydroFix™ HRU Kit that you will need: HydroFix ™ Repl acement Hydrostatic Release Un it (E) Capsule desig n release rod (B) Keyed brack et adapter (D) Large cotter p in (H ) HRU expirat[...]
-
Page 17
Y1 -06-020 9G 16 7.) Record th e expiration date on the HRU expiration label (K) with a n indelible mark er. 8.) Push the rele ase spring back against the brack et aligning the h oles on the spring with the holes in the back cover of the brack et. 9.) T ake the assem bled HRU and place the washer e nd of the HRU through the larger t op hole and sli[...]
-
Page 18
Y1 -06-020 9G 17 A PPENDIX A – WARRANTY , USEFUL LIFE POLI CY, NOTICES LIMITED WARRANTY This product is warranted agains t factory defects in material and workmanship for a period of 1 (one) year* from date of purchase or receipt as a gift. During the warranty period ACR Electronics, Inc. will repair or, at its option, replace the unit at no cost[...]