Go to page of
Similar user manuals
-
Switch
ADC and V35
103 pages 1.08 mb -
Switch
ADC FireWire Patch Panel IEEE 1394a
2 pages 5.11 mb -
Switch
ADC CUDA 3
620 pages 5.11 mb -
Switch
ADC 745P
4 pages 0.22 mb -
Switch
ADC TrueNet Workstation Solutions none
4 pages 0.18 mb -
Switch
ADC NCX-1000
4 pages 0.41 mb -
Switch
ADC PowerWorx Circuit Breaker Panel With Reset Switch
40 pages 15.74 mb -
Switch
ADC UltraWAVE
4 pages 0.1 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of ADC Micro BS Plus UltraWAVE, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ADC Micro BS Plus UltraWAVE one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of ADC Micro BS Plus UltraWAVE. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of ADC Micro BS Plus UltraWAVE should contain:
- informations concerning technical data of ADC Micro BS Plus UltraWAVE
- name of the manufacturer and a year of construction of the ADC Micro BS Plus UltraWAVE item
- rules of operation, control and maintenance of the ADC Micro BS Plus UltraWAVE item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ADC Micro BS Plus UltraWAVE alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ADC Micro BS Plus UltraWAVE, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ADC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ADC Micro BS Plus UltraWAVE.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the ADC Micro BS Plus UltraWAVE item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
UltraW A VE Micr o IP BS Plus IP GSM Base Station Contr oller and Base T ransceiver Station www .adc.com • +1-952-938-8080 • 1-800-366-3891 Spec Sheet The UltraW A VE Micro IP BS Plus is an integrated base station controller (BSC) and base transceiver station (BTS) in a single enclosure. UltraW A VE R4S softswitch and Micro IP BS Plus work hand[...]
-
Page 2
10/08 • 106419AE UltraW A VE Micr o IP BS Plus UltraW A VE Micr o IP BS Plus IP GSM Base Station Controller and Base T ransceiver Station 2 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Features: Availablein850,900,1800and1900MHzfr equencybands • Frequencyhopping • Sectorization • Genera[...]
-
Page 3
10/08 • 106419AE UltraW A VE Micr o IP BS Plus UltraW A VE Micr o IP BS Plus IP GSM Base Station Controller and Base T ransceiver Station 3 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Specifications BTS Configurations (single cabinet): O1, O2, S11 Frequency Support: GSM 850 MHz, GSM900 MHz, DCS 1800 MH[...]
-
Page 4
Spec Sheet Website: www.adc.com From North Americ a,Call TollFree :1-800 -366 -389 1•Outsi deofNort hAmeri ca:+1- 952- 938- 8080 Fax:+1-952-917-3237 • For a listing ofADC’s global sales office locations, please referto our website. ADC Telecommunications, I[...]