A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Advantech ADAM-5560, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Advantech ADAM-5560 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Advantech ADAM-5560. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Advantech ADAM-5560 should contain:
- informations concerning technical data of Advantech ADAM-5560
- name of the manufacturer and a year of construction of the Advantech ADAM-5560 item
- rules of operation, control and maintenance of the Advantech ADAM-5560 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Advantech ADAM-5560 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Advantech ADAM-5560, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Advantech service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Advantech ADAM-5560.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Advantech ADAM-5560 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
User Manual ADAM-5560 Series Programmable Automation Controllers[...]
-
Page 2
ADAM-5560 Series User Manual ii Copyright The document ation and the sof tware included with th is product are cop yrighted 2012 by Advantech Co., Ltd. All r ights are reserv ed. Advantech Co., Ltd . reserves the right to make improvements in the product s descr ibed in this manual at any time without notice. No p art of this manual may be repr odu[...]
-
Page 3
iii ADAM-5560 Series User Manu al Declaration of Conformity CE This product has passed the CE test for env ironment al specifications when shielded cables are used for external wiring. W e recommend the use of shielded cables. This kind of cable is available from Advantec h. Please contact your local supplier for ordering information. FCC Class A N[...]
-
Page 4
ADAM-5560 Series User Manual iv Safety Instructions 1. Read these safety instructions carefully . 2. Keep this User Manual f or later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents fo r cleaning. 4. For plug-in equipment, the po wer outlet socket must be located n [...]
-
Page 5
v ADAM-5560 Series User Manu al Content s Chapter 1 Overview ...............................................1 1.1 Introduction .... ................... ................. ................ ................ ................ ....... 2 1.2 Features ................ ................ ................ ................ ................ ................ ....[...]
-
Page 6
ADAM-5560 Series User Manual vi Figure 2.4 COM1/COM4 RS-232/485 Settings ............. ... .... ... .. 22 Figure 2.5 COM1 RS-23 2/485 and Terminal Resistor Settings. 23 Figure 2.6 COM3 RS-23 2/485 and Terminal Resistor Settings. 23 Figure 2.7 COM4 RS-23 2/485 and Terminal Resistor Settings. 23 Figure 2.8 ADAM-5560 Series DIP Switch ....... ........[...]
-
Page 7
vii ADAM-5560 Series User Manu al A.1 RS-485 Networks ........... ... .... ... ... ... .... ... ................ ... ... .... ... ................ ... 168 A.2 Basic Network Layout ....... ................. ................ ................ ................ ... 168 Figure A.1 Daisychaining ...... ................... ................ ................[...]
-
Page 8
ADAM-5560 Series User Manual viii[...]
-
Page 9
Chapter 1 1 Overview[...]
-
Page 10
ADAM-5560 Series User Manual 2 1.1 Introduction ADAM-5560 Series Controlle r is Programm able Automation Controller designed for control tasks which require Industrial PC computing performance with the PLC’s robustness. ADAM-5560 Series Controller of fers Intel A TOM Z510P CPU along with control specific features such as watchdog time r , battery[...]
-
Page 11
3 ADAM-5560 Series User Manu al Chapter 1 Overview Designed for control t asks that meet robust and computing performance requirement s of PLC and Industrial PC’ s ADAM-5560 Series Controller is designed for control t asks which need Industrial PC’s computing performance and PLC’ s robustness. It s multiple functionalities include discrete, a[...]
-
Page 12
ADAM-5560 Series User Manual 4 Cross-Language Programming For some project integrate and scalable issue s, cross-language can help you to choose the different lang uage for you r projec t. Fo r example, you can use ladder (LD) on the simple I/O module control or simple log ical expression and u se Function Block (FB) on process control for more adv[...]
-
Page 13
5 ADAM-5560 Series User Manu al Chapter 1 Overview Real time multi-t ask engine ADAM-5560 Series Controller provides the multi-task and multi-program e nviron- ment. ADAM-5560 Series Controller ’s communication, dat a process and I/O access tasks are working independent, so the sy stem performance and ef ficiency are better than traditional PLC. [...]
-
Page 14
ADAM-5560 Series User Manual 6 Dual Ethernet Port s ADAM-5560 Series Controller provides tw o Ethernet port s for different application requirements such as redundant Ethernet conne ction for reliability concern or sep a - rated network connections for security conc ern. Bo th of the functions are possible to be implemented by customer’s applicat[...]
-
Page 15
7 ADAM-5560 Series User Manu al Chapter 1 Overview Remote maintenance via FTP Server and Diag Anywhere Sof tware For remote maintenance function, the built-in FTP server provides service for upload- ing application program or downloading dat a logging files. DiagAnywhere Sof twar e is also supported for remote cont rol, download and upload function[...]
-
Page 16
ADAM-5560 Series User Manual 8 Remote I/O Exp ansibility ADAM-5560 Series Controller supports not only Modb us/RTU Ma ster function via serial ports, but also the Modbus/TCP Client to retrieve data from remote I/O, and Modbus/TCP Server to exchange dat a with other Modbus devices via Etherne t port. This Modbus features are very useful when the con[...]
-
Page 17
9 ADAM-5560 Series User Manu al Chapter 1 Overview Connector: DB-9 pin T ransmission speed: Up to 1 15.2 Kbps Max transmission dist ance: – RS-232: 50 feet (15.2 m) – RS-485: 4,000 feet (1220 m) 1.3.6 RS-485 interface (COM2) Signals: DA T A +, DA T A - Mode : Half duplex, multi-drop Connector: Screw terminal T ransmi[...]
-
Page 18
ADAM-5560 Series User Manual 10 1.3.1 1 Mechanical Case: ABS+PC with captive mounting hardware Plug-in screw terminal block: Accepts 0.5 mm 2 to 2.5 mm 2 , 1 - #12 or 2 - #14 to #22 A WG 1.3.12 Environment Operating temperature: 0 ~ 55° C ( 32 ~ 122° F) S torage temperature: -25° to 85° C (-13° to 185° F) Humidity: 5 to 95[...]
-
Page 19
11 ADAM-5560 Series User Manu al Chapter 1 Overview There are two LEDs besides each Ethern et p o rt. The LEDs indicate operating st atus, as explained below: TX (Green): This LED blinks whenever the ADAM-5560 Series Controller transmitting data to Ethernet. Link (Orange): This LED is on whenever the ADAM-5560 Series Controller connecting to Ethern[...]
-
Page 20
ADAM-5560 Series User Manual 12[...]
-
Page 21
Chapter 2 2 Installation[...]
-
Page 22
ADAM-5560 Series User Manual 14 2.1 Overview This chapter describes how to in stall an ADAM-5560 Series Controller . A quick hookup scheme is provided that let you easily configu re your system before imple- menting it into your application. 2.2 System Requirement s Before you st art installing th e ADAM-5560 Series Controlle r , make sure the syst[...]
-
Page 23
15 ADAM-5560 Series User Manu al Chapter 2 Installation 2.3 Hardware Inst allation 2.3.1 Selecting I/O Module T o organize an ADAM-5560 Series control sy stem, you need to select I/O modules to interface the main unit with field de vices or processes that you ha ve previously deter- mined. There are several things sh ould be considered when yo u se[...]
-
Page 24
ADAM-5560 Series User Manual 16 Module ADAM- 5013 ADAM- 5017 ADAM- 5017UH ADAM- 5018 ADAM- 5024 Analog Input Resolution 16 bit 16 bit 12 bit 16 bit - Input Channel 3 8 8 7 - Sampling Rate 10 10 8K (T otal ) 10 - V oltage In put - ±150 mV ±500 mV ±1 V ±5 V ±10 V ±10 V 0~10V 0~20mV ±15 mV ±50 mV ±100 mV ±500 mV ±1 V ±2.5 V - Current Input[...]
-
Page 25
17 ADAM-5560 Series User Manu al Chapter 2 Installation Module ADAM- 5052 ADAM- 5055S ADA M- 5056 ADAM- 5056D ADAM- 5056S / 5056SO Analog Input Resolution - - - - - Input Channel -- -- - Sampling Rate -- -- - V oltage Input - - - - - Current Input -- -- - Direct Sensor Input -- -- - Analog Output Resolution - - - - - V oltage Output - - - - - Curre[...]
-
Page 26
ADAM-5560 Series User Manual 18 2.3.2 Selecting Power Supply Module ADAM-5560 Series Controller works under unregulated power so urce between +10 and +30 VDC. When you arrange d ifferent I/ O modules on ADAM-5560 Series Con- troller ’s backplane, it may require comp arab le power supply . Use the following step s as guidelines for selecting a pow[...]
-
Page 27
19 ADAM-5560 Series User Manu al Chapter 2 Installation Calculate the Summary of the whole system’s power consumption. For example, there are following items in your system. ADAM-5550KW * 3 & ADAM-5024 * 2 & ADAM-5017 * 4 & ADAM-5068 * 2 & ADAM-5056D * 2 The power consumption is: 17 W * 3 + 2.9 W * 2 + 1.25 * 4 + 1.8 W * 2 + 0.84 [...]
-
Page 28
ADAM-5560 Series User Manual 20 Select a suitable power supply from T able 2.4 or other comp arable power resource for system operation. 2.3.3 Inst all Main Unit and Modules While inserting modules into the system, align the PC board of the module with the grooves on the top and bottom of the system. Push th e module straight into the sys- tem unti[...]
-
Page 29
21 ADAM-5560 Series User Manu al Chapter 2 Installation 2.3.5 Mounting The ADAM-5560 Series Controller can be in stalled on a p anel or on a DIN rail. 2.3.5.1 Panel Mount Mount the system on th e panel horizontally to provide proper ventilation. Y ou cannot mount the system vertically , upside down or on a flat horizont al surface. A standard #7 ta[...]
-
Page 30
ADAM-5560 Series User Manual 22 The system can also be secured to the cabi net by using mounting rails. If you mount the system on a rail, you s hould also consider using end brackets at each end of the rail. The ended bracket s help keep th e system from sliding horizonta lly along the rail. This minimizes the possibility of accident ally pulling [...]
-
Page 31
23 ADAM-5560 Series User Manu al Chapter 2 Installation COM1 Jumper Setting The Communication port of COM1 is set by CN4, CN5, CN6 (Mode) and CN7 (T ermi- nal Resistor). Figure 2.5 COM1 RS-232/485 and T erminal Resistor Settings COM3 Jumper Setting The Communication port of COM3 is set by CN9, CN10, CN1 1 (Mode) and CN12 (T erminal Resistor). Figur[...]
-
Page 32
ADAM-5560 Series User Manual 24 2.3.6.2 DIP Switch Setting Figure 2.8 ADAM-5560 Series DIP Switch Device ID Setting: Y ou can set up your device ID by changing DIP Switch 1-8. The available ID for ADAM-5560 Series Controller is from 0 to 255. Please refer to the T able 2.6 Device ID DIP Switch T able to set up your Device ID. T able 2.5: Device ID [...]
-
Page 33
25 ADAM-5560 Series User Manu al Chapter 2 Installation 2.3.7 COM Port Pin Assignment s Figure 2.9 RS-232 Port Pin Assignment Figure 2.10 RS-485 Port Pin Assignment[...]
-
Page 34
ADAM-5560 Series User Manual 26 2.4 System Wi ring and Connections This section provides basic information on wiring the power su pply , I/O modules and communication port connection. 2.4.1 Power Supply Wiring Although the ADAM-5560 Series Co ntroller is designed for a stan dard industrial unregulated 24 V DC power supply , they accept any power un[...]
-
Page 35
27 ADAM-5560 Series User Manu al Chapter 2 Installation 2.4.3.1 Remote I/O Wiring Modbus/RT U Master Function via COM1/COM2/COM4 RS-485: Figure 2.12 Remote I/O Wirin g Y ou can connect typical 128 ADAM-4000 Modbus Remote I/O modules via COM1/ COM2/COM4. Please set the COM1 and COM4 as RS-485 mode. 2.4.4 Ethernet Network Connection The ADAM-5560 Ser[...]
-
Page 36
ADAM-5560 Series User Manual 28[...]
-
Page 37
3 Quick Start Chapter 3[...]
-
Page 38
ADAM-5560 Series User Manual 30 This chapter will help you get familiar with ADAM-5560KW Controller and Multiprog Programming Software by following step by step examples. In this chapter , you need to prepare the system configur ation as below . Main Module: ADAM-5560KW X1, IP Address: 192.168.1.5 Local I/O Modules: ADAM-5051D in Slot 0 ADAM-5056D [...]
-
Page 39
31 ADAM-5560 Series User Manu al Chapter 3 Quick Start 3.1 Set IP Address to ADAM-5560KW 1. [P AC Device] Power up ADAM-5560KW and click “S tart”. 2. [P AC Device] Click “Settings” and “Network and Dial-up Connections”.[...]
-
Page 40
ADAM-5560 Series User Manual 32 3. [PAC Device] Right click “PCI-RTL8139 1” icon and then click “Properties”. 4. [PAC Device] T ype IP Address like “192.168.1.5” and Subnet Mask “255.255.255.0”.[...]
-
Page 41
33 ADAM-5560 Series User Manu al Chapter 3 Quick Start 5. [PAC Device] Right click “PCI-R TL81392” icon and then click “Properties”. 6. [PAC Device] T ype IP Address like “192.168.1.6” an d Subnet Mask “255.255.255.0”. Now the IP address conf iguration has been finished.[...]
-
Page 42
ADAM-5560 Series User Manual 34 7. If your PC has inst alled DiagAnywhere Sof tware, you can search the ADAM- 5560KW and check the Ethernet connectio n. Please click the “Remote device” and click “Search” button. 8. Click “ADAM-5560” and then click OK button without ente ring any password.[...]
-
Page 43
35 ADAM-5560 Series User Manu al Chapter 3 Quick Start 9. The screen of ADAM-5560KW will be shown in the window . Now it is possible to remotely control the ADAM-5560KW by PC’ s mouse. 3.2 Configure ADAM-5000 Local I/O 1. [P AC Device] Click “S tart” -> “Programs” -> “Advantech” -> “Adam.NET Utility”.[...]
-
Page 44
ADAM-5560 Series User Manual 36 2. [P AC Device] Click “Local system” to view the local I/O modules. 3. [P AC Device] ADAM-5051 and ADAM-5056 are listed. Sele ct “ADAM-5051”.[...]
-
Page 45
37 ADAM-5560 Series User Manu al Chapter 3 Quick Start 4. [PAC Device] Check the st ate of DI 0 is “ON”. 5. [PAC Device] Change the st ate of DI 0 to “OFF” and check the d isplay .[...]
-
Page 46
ADAM-5560 Series User Manual 38 6. [PAC Device] Select “ADAM-5056”. 7. [PAC Device] Change the state of DO 0, DO 2, DO 4 , DO 6, DO 8, DO 10,DO 12, DO 14 to “ON” and check the display .[...]
-
Page 47
39 ADAM-5560 Series User Manu al Chapter 3 Quick Start 3.3 Multiprog Inst allation Following will guide you how to setup Mult iprog IEC-61 131-3 development environ- ment on your PC. 1. Please use your web browser to visit Ad vantech web site. (www .advan- tech.com) 2. T y pe "ADAM-5560" on the search box which is on the right-up corner o[...]
-
Page 48
ADAM-5560 Series User Manual 40 2. Click “OK” to enter the DEMO Mode. 3. Click “Register” to enter the Registration Code.[...]
-
Page 49
41 ADAM-5560 Series User Manu al Chapter 3 Quick Start 4. Enter the Registration Code which come s with Advantech Multiprog Sof tware License Sheet. 5. Click “OK” to finish the registration.[...]
-
Page 50
ADAM-5560 Series User Manual 42 6. Open a new project and st art to create the test project. 7. Select “ADAM-5560KW” item and then click “OK”.[...]
-
Page 51
43 ADAM-5560 Series User Manu al Chapter 3 Quick Start 8. Double click “Advant ech DAQ” item. 9. Check the folder is at “Input”.[...]
-
Page 52
ADAM-5560 Series User Manual 44 10. Select “ADAM5051” and then click “Add”. 11 . Select “0” for “Board ID”. Set “0” to “S tart Address” and then click “OK”.[...]
-
Page 53
45 ADAM-5560 Series User Manu al Chapter 3 Quick Start 12. Click “Create All Input V ariables” and then click “OK”. 13. Click “Output” folder . Select “ADAM5056” and then click “Add”.[...]
-
Page 54
ADAM-5560 Series User Manual 46 14. Select “1” for “Board ID”. Set “0” to “S tart Address” an d then click “OK”. 15. Click “Create All Input V ari ables” and then click “OK”.[...]
-
Page 55
47 ADAM-5560 Series User Manu al Chapter 3 Quick Start 16. Double click “main” and graphi cal worksheet will be shown. 17. Click on the graphical editor and ladder obje cts will be activated.[...]
-
Page 56
ADAM-5560 Series User Manual 48 18. Add a cont act network. 19. Double click “C000”.[...]
-
Page 57
49 ADAM-5560 Series User Manu al Chapter 3 Quick Start 20. Dialog box of “Contact/Coi l Property” will be shown. 21. Click “Global scope”. Select “In_ ADAM5051_ 0_0” and then click “Apply”.[...]
-
Page 58
ADAM-5560 Series User Manual 50 22. “Common” folder will be shown. Click “Cont act” folder . 23. Click “Global”. Select “ADAM5051_B00C000_I” an d then click “Apply”.[...]
-
Page 59
51 ADAM-5560 Series User Manu al Chapter 3 Quick Start 24. Click “OK”. 25. Double click “C001”.[...]
-
Page 60
ADAM-5560 Series User Manual 52 26. Click “Global”. Select “ADAM50 56_B01C000_O” and then click “Apply”. 27. Click “OK”.[...]
-
Page 61
53 ADAM-5560 Series User Manu al Chapter 3 Quick Start 28. Back to graphical editor . 29. Right click “Resource: ADV_CE” and then click “Settings”.[...]
-
Page 62
ADAM-5560 Series User Manual 54 30. T ype IP Address of ADAM-5560KW as “192.168.1 .5”. 31. Click “Make” to build the exe cution fi le. Check the project has been compiled successfully .[...]
-
Page 63
55 ADAM-5560 Series User Manu al Chapter 3 Quick Start 32. Click “Project Control Dialog” and then click “Download”. 33. Check “Include boot project” and then click “Download ”.[...]
-
Page 64
ADAM-5560 Series User Manual 56 34. Downloading execution file to ADAM-556 0KW . 35. Click “Cold” to execute a cold st art. During a cold sta rt all data are initialized.[...]
-
Page 65
57 ADAM-5560 Series User Manu al Chapter 3 Quick Start 36. Click “Debug On/Of f” to turn on the debug functio n. The ADAM-5560KW is run- ning correctly when you see the st atus bar turns green color . Y ou can see the DI0 and DO0 are turned blue co lor . It means the st ate is F ALSE. 37. When you change the st ate of ADAM-5051D CH0 as ON, ADAM[...]
-
Page 66
ADAM-5560 Series User Manual 58 38. Finish the test project and do n ot forget to save it properly .[...]
-
Page 67
59 ADAM-5560 Series User Manu al Chapter 3 Quick Start 3.5 S pecial Module Support in KW ADAM-5050 is one of mix digi tal input /output module and ea ch channel can be inde- pendently configured to be an input or an output channel by the setting of it s DIP switch (Please refer the user manu al of ADAM-5000 IO Module to get more det ail). For the A[...]
-
Page 68
ADAM-5560 Series User Manual 60[...]
-
Page 69
Chapter 4 4 Modbus Functions[...]
-
Page 70
ADAM-5560 Series User Manual 62 4.1 Introduction The Modbus functions of ADAM-5560KW Cont rolle r are powerfu l featu res which pro- vide high expansib ility and flexibility for user ’s applications. The supported mod bus functions include following items. Modbus/R TU Master Function: Connect to Modbus/R TU remote I/O modules such as Modbus m[...]
-
Page 71
63 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 4.2.1 An example to demonstrate how to connect to ADAM-6050 for Modbus/TCP client function 1. [PAC Device] Run ADAM.NET utility by clicki ng “S tart” -> “Programs” -> “Advantech” -> AdamNET Utility . 2. [PAC Device] Select “ADAM5000TCP_6000” item.[...]
-
Page 72
ADAM-5560 Series User Manual 64 3. [PAC Device] Click “Search” button. 4. [PAC Device] Click “192.168.1.12” item and then “6050” item will show .[...]
-
Page 73
65 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 5. [PAC Device] Click “6050” item to see the channel setting. 6. [PAC Device] Enter “00000000” and then click “OK” b utton.[...]
-
Page 74
ADAM-5560 Series User Manual 66 7. [PAC Device] Check ADAM-6050 DI bit 0 is OFF . 8. [PAC Device] T urn on ADAM-6050 DI bit 0 and make sure the st atus is ON in the utility .[...]
-
Page 75
67 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 9. [PAC Device] ADAM-6050 setting is correct. Ex it from the ADAM.NET utility . 10. Open “T est.mwt” and follow the example in section 3.4.[...]
-
Page 76
ADAM-5560 Series User Manual 68 11 . Double-click “main” to show the program in graphical editor . 12. Double-click “Advant ech_DAQ” to show the “I/O Configuration” dialog box.[...]
-
Page 77
69 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 13. Click “MODBUSTCP” item and then click “Add” button. 14. Set Modbus Command: “1X”, Slave ID: 1, Slave IF: “192 .168.1.12”, Data T ype: “BOOL”, S tart Address: “1”, No. of point s: 12.[...]
-
Page 78
ADAM-5560 Series User Manual 70 15. Click “Create All Input V ari ables” then click “OK” button. 16. Click “Cont act Network” button.[...]
-
Page 79
71 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 17. Double-click “C002”. 18. Click “Gloabal scope” folder .[...]
-
Page 80
ADAM-5560 Series User Manual 72 19. Select “In_MBTCPDR V_0_1” and then click “Apply”. 20. Click “Contact” folder .[...]
-
Page 81
73 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 21. Select “MBTR_1X0001_BOOL_00” and the n click “Apply”. 22. Check the setting is correct and then click “OK”.[...]
-
Page 82
ADAM-5560 Series User Manual 74 23. Double-clic k “C003”. 24. Select “ADAM5056_B01C001_0” and t hen click “Apply”.[...]
-
Page 83
75 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 25. Check the setting is correct and then click “OK”. 26. Click “Make” button to make the execution file.[...]
-
Page 84
ADAM-5560 Series User Manual 76 27. Check compile result is correct. 28. Click “Project Control Dia log” and then click “S top” and “Reset”.[...]
-
Page 85
77 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 29. Click “Download” button. Check the “Inclu de Bootproject” item and then click “Download” button to proceed with the download p rocess. 30. Execution file is downloading.[...]
-
Page 86
ADAM-5560 Series User Manual 78 31. Click “Cold” to run the project. 32. Check the sta tus of ADAM-6050 DI bit 0 and ADAM-50 56D DO bit 1 are OFF .[...]
-
Page 87
79 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 33. T urn on ADAM-6050 DI bit 0 and check th e st atus of ADAM-5056D DO bit 1 is turned ON correctly . 34. Save the project properly .[...]
-
Page 88
ADAM-5560 Series User Manual 80 4.3 Modbus/RTU Master Function The Modbus/R TU master function is supported by COM1/COM2/COM4 RS-485 Ports of ADAM-5560 Series Controller . There ar e typical 128 I/O modules can be connect ed to each COM port. So far , there are 12 modules of ADA M- 4000 Series s upport mod- bus protocol as following list. (Please r[...]
-
Page 89
81 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions System Wiring: COM4 Jumper Settings: Note! After changing the ju mper settings, please reset th e ADAM-5560 Series Controller.[...]
-
Page 90
ADAM-5560 Series User Manual 82 RS-485 Port Pin Assignment: 1. [P AC Device] Run ADAM.NET utility by clicki ng “S tart” -> “Programs” -> “Advantech” -> Ad amNET Utility .[...]
-
Page 91
83 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 2. [P AC Device] Select “ADAM4000_5000” item. 3. [P AC Device] Select “COM4” and then click “Search” button.[...]
-
Page 92
ADAM-5560 Series User Manual 84 4. [P AC Device] Click “S tart” button and “4018P” will be shown. 5. [P AC Device] Click “4018P” to see the module setting.[...]
-
Page 93
85 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 6. [P AC Device] Click “Data area” to check the reading of Channel 0 is cor rect. This channel will be used by following demonstratio n. 7. [P AC Device] Select “COM4” and then click “Adam Commander” button.[...]
-
Page 94
ADAM-5560 Series User Manual 86 8. [P AC Device] Input “#010” and click “Send”. Check the response of the CH0 reading is correct. 9. [P AC Device] Set the ADAM-4018+ to initial mode by changing th e switch position to “Init” side and then resetting the module. The switch is at the left side of the module. After that, se lect “COM 4”[...]
-
Page 95
87 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 10. [P AC Device] Click “S tart” and “4018(*)” will be shown. “*” represent s the module is at initial mode. 11 . [P AC Device] Select “4018P(*)” and then change the Protocol setting to “Modbus”.[...]
-
Page 96
ADAM-5560 Series User Manual 88 12. [P AC Device] Click “OK” to change the set ting. 13. [P AC Device] Select “Data area” and check the CH0 reading. Click “W aveScan” to see the wavescan window .[...]
-
Page 97
89 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 14. [P AC Device] Check CH0 reading and then close the window . 15. [P AC Device] Set the ADAM-4018+ to normal mode by changing the switch position to “Normal” side and then resetting the mod ule. After that, select “COM4” and then click “Search” and “S tart” buttons.[...]
-
Page 98
ADAM-5560 Series User Manual 90 16. [P AC Device] Click “4018P(01)” to see the module setting. 17. [P AC Device] Select “Data area” folder and check CH0 reading.[...]
-
Page 99
91 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 18. [P AC Device] Select “COM4” and then click “Adam Commander”. 19. [P AC Device] Change to “MODBUS” folder .[...]
-
Page 100
ADAM-5560 Series User Manual 92 20. [P AC Device] Check the reading of CH0. The formula is (1215*1370) / 65 536 = 25.4 ºC. 21. Open the “T est.mwt” project and then double-click “main”.[...]
-
Page 101
93 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 22. Double-click “Advantech_DAQ”. 23. Select “MODBUSRTU” and then click “Add” button.[...]
-
Page 102
ADAM-5560 Series User Manual 94 24. Set COM: “COM4”, Modbus Command: “3 X”, Slave ID: 1, S tart Address: “1”, No. of points: 8, Data T ype: “INT”. 25. Click “Create All Input V a riables” and then click “OK”.[...]
-
Page 103
95 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 26. Click “Edit Wizard” to see the function blocks. 27. Find the “GT” Greater Than Function Block.[...]
-
Page 104
ADAM-5560 Series User Manual 96 28. Add one “GT” function block. 29. Add one coil by clicking “Ad d Coil Right” button.[...]
-
Page 105
97 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 30. Connect “C004” coil to “GT” output. 31. Double-click the first input of “GT” function block.[...]
-
Page 106
ADAM-5560 Series User Manual 98 32. Select “Global scope” folder . 33. Select “In_MBR TUDR V_769_772” and then click “Apply”.[...]
-
Page 107
99 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 34. Select “MBR_3X0001_INT_769_I” to read CH0 of ADAM-4018+ module and then click “Apply”. 35. Double-click on the se co nd i npu t o f “ GT” fun ct ion blo ck .[...]
-
Page 108
ADAM-5560 Series User Man ual 100 36. T ype “1 196” and then Click “Apply” and “OK”. 37. Check the setting “1 196” is correct. (1 196*1370)/65536 = 25ºC[...]
-
Page 109
101 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 38. Double-click “C004”. 39. Select “ADAM5056_B01C002_O” to connec t the “GT” function block output to ADAM-5056D DO bit 2. Click “Apply” and “OK”.[...]
-
Page 110
ADAM-5560 Series User Man ual 102 40. Click “Make” button t o make the execution file. 41. Check compile result is correct.[...]
-
Page 111
103 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 42. Click “Project Control Dialog” button and then click “S top” and “Reset”. 43. Click “Download” button. Check the “Include bootproject” item and then click “Download” to proceed with download process.[...]
-
Page 112
ADAM-5560 Series User Man ual 104 44. Project is downloading. 45. Click “Cold” button to run the project.[...]
-
Page 113
105 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 46. Click “Debug on/of f” button. 47. Check the reading of ADAM-4018+ CH0 is “1088” which is less than “1 196”. The ADAM-5056D DO CH2 is OFF .[...]
-
Page 114
ADAM-5560 Series User Man ual 106 48. Heating the thermocouple of ADAM-4018+ CH0. When the readi ng is gr eat er than “1 196”, the ADAM-5056D DO CH2 will turn ON. 49. Save the project for following demonstration.[...]
-
Page 115
107 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 4.4 Modbus/TCP Server Functions ADAM-5560 Series Controller support s M odbus/TCP server function for connecting to HMI/SCADA software. The Modbus/TCP ser ver function is supported by using Ethernet port of ADAM-5560 Series Controller . 4.4.1 Modbus Address Mapping ADAM-5560 Series Contro[...]
-
Page 116
ADAM-5560 Series User Man ual 108 4.4.2 Example 1. Open the “T est.mwt” and add one “Move” f unction block. 2. “Move” function block will be shown on gra phical editor .[...]
-
Page 117
109 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 3. Double-click the input of “Move” function b lock. Select “MBTR_1X0001_BOOL_00” (ADAM-6050 DI bit 0) and then click “Apply” and “OK”. 4. Double-click output of “M ove” function block.[...]
-
Page 118
ADAM-5560 Series User Man ual 110 5. T ype “MB0X0001” and click “Apply” button. 6. Select “BOOL” for Dat a T ype. T ype “%mw3.0.0” for “I/O address” and th en click “Apply” and “OK”.[...]
-
Page 119
111 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 7. Click “Make” button to make the execution file. 8. Check compile resul t is correct.[...]
-
Page 120
ADAM-5560 Series User Man ual 112 9. Click “Project Control Dialog” button and then click “S top”. 10. C l i c k “Reset” button.[...]
-
Page 121
113 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 11 . Click “Download ” button. Check the “Include bootproject” item and then click “Download” to proceed with download process. 12. Project is downloading.[...]
-
Page 122
ADAM-5560 Series User Man ual 114 13. Click “Cold” to run the project. Click “Debug on/of f” button to see the result. 14. Run Modbus/TCP Client u tility Modscan and check the value of I/O address mw3.0.0 and Modscan I/O address 00001 are the same.[...]
-
Page 123
115 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 15. Change the status o f ADAM-6050 DI bit 0 to “1”. Check the values of I/O address mw3.0.0 and Modscan I/O address 00 001 are all changed to “1”. 16. Add one more “Move” fu nction block for analog measurement.[...]
-
Page 124
ADAM-5560 Series User Man ual 116 17. Double-click the input of the 2 nd “Move” function block. Select “MBR_3X0001_INT_769_I” (ADAM-4018+ CH0) and then click “App ly” and “OK”. 18. Double-click the output.[...]
-
Page 125
117 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 19. T ype “MB4X0001” and then click “Apply”. 20. Select “INT” for Data T ype. T ype “%mw3.2” for “I/O address” and then click “Apply” and “OK”.[...]
-
Page 126
ADAM-5560 Series User Man ual 118 21. Click “Make” button to make the execution file and check the compile result is correct. 22. Click “Project Control Dialog” b utton.[...]
-
Page 127
119 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 23. Click “S top” and “Reset” button. 24. Click “Download” button. Check the “Include bootproject” item and then click “Download” to proceed with download process.[...]
-
Page 128
ADAM-5560 Series User Man ual 120 25. Project is downloading. 26. Click “Cold” to run the project . Click “Debug on/of f” button to see the result.[...]
-
Page 129
121 ADAM-5560 Series User Manu al Chapter 4 Modbus Functions 27. Run Modbus/TCP Client utility Modscan and check the values of I/O address mw3.2 and Modscan I/O address 40002 are the same. 28. Save the project and the test is finish ed.[...]
-
Page 130
ADAM-5560 Series User Man ual 122[...]
-
Page 131
Chapter 5 5 Network Functions[...]
-
Page 132
ADAM-5560 Series User Man ual 124 5.1 W e b Server Functions ADAM-5560 Series Controller features bui lt-in web server function of Windows CE 5.0. Before you using the web server function, please do follow the step s in section 7.1.1 to configure the basic settings properly . For monitoring and co ntrolling the local I/O modules on ADAM-5560 Series[...]
-
Page 133
125 ADAM-5560 Series User Manu al Chapter 5 Network Functions 2. The NAS Admin page will be shown. T ype in the password, for examp le, “admin” and then click “Apply”. 3. Gateway is resetting.[...]
-
Page 134
ADAM-5560 Series User Man ual 126 4. Internet Explorer will connect to server automatically an d ask to type the user name and password a gain. 5. Change the Device Name like “A DAM-5510-1” and then click “Apply”.[...]
-
Page 135
127 ADAM-5560 Series User Manu al Chapter 5 Network Functions 6. Click “Add/Del Users” to change the password of user name “ad min”, if necessary . 7. T ype “admin” in “User” field. In foll owing example, please type “admin” in “Password” field and then click “Apply New”.[...]
-
Page 136
ADAM-5560 Series User Man ual 128 8. The message “Add/Modify User Success” will be shown. 9. Run “Configuration Utility”.[...]
-
Page 137
129 ADAM-5560 Series User Manu al Chapter 5 Network Functions 10. Click “Misc” folder . 11 . Change to “Misc” folder and “Web Server Root” will be modified. 12. User can put the developed web page in the specific fo lder in ADAM-5560 and link the webpage by change the W eb Server Root.[...]
-
Page 138
ADAM-5560 Series User Man ual 130 13. Click “OK” to reboot the ADAM-5 560.[...]
-
Page 139
131 ADAM-5560 Series User Manu al Chapter 5 Network Functions 5.2 FTP Server Function ADAM-5560 Series Controller features built-in FTP Server function of Windows CE 5.0. Before you using the FTP Server fun ction, please do follow the step s as below to configure the basic settings properly . The default setting of FTP Server function in Windows CE[...]
-
Page 140
ADAM-5560 Series User Man ual 132 2. Click “Device Management”. 3. Click “Configure FTP Server”.[...]
-
Page 141
133 ADAM-5560 Series User Manu al Chapter 5 Network Functions 4. Enter the “FTP Server Configuration” page. 5. Check “FTP Server Enabled”, un-check “Allow Ano nymous Users”, change “Default Directory” as “HardDiskFTP”. Click “Submit” button.[...]
-
Page 142
ADAM-5560 Series User Man ual 134 6. Click “Reboot” button. 7. After the ADAM-5560 was rebooted, following p age will be shown again.[...]
-
Page 143
135 ADAM-5560 Series User Manu al Chapter 5 Network Functions 8. Scroll down the p age. Check the “Home Directory” for all users and th en click “Submit” button. 9. W ait for a moment for resetting.[...]
-
Page 144
ADAM-5560 Series User Man ual 136 10. After re setting, following p age will be sh own again. The basic settings for FTP Server have been configured. 11 . Right-click the mouse and then add a new directory “New Folder” under “HardDisk” directory of ADAM-5560 Series Cont roller .[...]
-
Page 145
137 ADAM-5560 Series User Manu al Chapter 5 Network Functions 12. Enter the name for the new folder as “FTP”. 13. Enter “HardDiskFTP” directory .[...]
-
Page 146
ADAM-5560 Series User Man ual 138 14. Add “T est FTP” directory . 15. T ype “ftp ://192.168.1.5” to login the FTP Server . Y ou will see the warning message because anonymous login is n ot allowed now .[...]
-
Page 147
139 ADAM-5560 Series User Manu al Chapter 5 Network Functions 16. Click “Login As” item to enter t he user name and passwo rd. 17. Login the FTP Server by usern ame: user1 and p assword: “user1”.[...]
-
Page 148
ADAM-5560 Series User Man ual 140 18. The “T est FTP” directory can be accessed now . 19. T ry to upload files onto FTP Server .[...]
-
Page 149
141 ADAM-5560 Series User Manu al Chapter 5 Network Functions 20. Upload the directory of “OPC” onto FTP Server . 21. Uploading process is proceedin g.[...]
-
Page 150
ADAM-5560 Series User Man ual 142 22. The uploaded “OPC” director y will be shown. 23. Check the files under “OPC” directory in FTP client.[...]
-
Page 151
143 ADAM-5560 Series User Manu al Chapter 5 Network Functions 24. Check the files under “OPC” directory o n the ADAM-5560. 5.3 Email Alarm Function There is an example for demonstrating how to sen d an email from ADAM-5560 Series Controller . Please refer to following info. 1. Open “AdvMailDemo.mwt”.[...]
-
Page 152
ADAM-5560 Series User Man ual 144 2. The function block is included by “AdvT oolPack” library . Double-click “main” to see the function block. 3. T ype the correct settings in the “Init” fields as below and try to run this e xample directly . Note! The sending email function is only suppor ted by mail server via intranet within enterpri[...]
-
Page 153
145 ADAM-5560 Series User Manu al Chapter 5 Network Functions 5.4 SQL Server Function There is an example for demonstrating how to use the built-in SQL Server function on ADAM-5560 Series Controller . Pl ease refer to following info. 1. Open “AdvSQLDemo.mwt”. 2. T ype to run this example directly .[...]
-
Page 154
ADAM-5560 Series User Man ual 146 SQL Function Block Reference: AdvSQL_Init Function: Initialize SQL mobile dat abase. 1. Enable: (BOOL), Enable AdvSQL function blocks. 2. DataBaseName: (STRING) , SQL mobile database na me. 3. T ableName: (STRING), SQL mobile dat abase table name. 4. ColumnT otal: (INT), T otal number of fields in SQL mobile data b[...]
-
Page 155
147 ADAM-5560 Series User Manu al Chapter 5 Network Functions AdvSQL_SelectLastDa t a Function: Read the last reco rd from SQL mobile database . 1. Enable: (BOOL), Enable AdvSQL function blocks. 2. DataBaseName: (STRING), SQL mobile dat abase name. Rreserved fo r handling more than one SQL mo bile database in the fu ture. 3. ColumnIndex: (INT), The[...]
-
Page 156
ADAM-5560 Series User Man ual 148[...]
-
Page 157
Chapter 6 6 Miscellaneous Functions[...]
-
Page 158
ADAM-5560 Series User Man ual 150 6.1 Advantech Utilities There are four Advantech utilities which a re pre-inst alled on ADAM-5560 Series Con- troller . The major functions are as below . Adam.NET Utility: CE version of ADAM Utility for configuring ADAM-5560 Series Local ADAM-5560 I/O Modules, ADAM- 4000 Remot e I/O Modules, ADAM-6000 and ADAM-556[...]
-
Page 159
151 ADAM-5560 Series User Manu al Chapter 6 Miscellaneous Functions 6.2 Change Language Interface of CE 1. Enter “Control Panel”. 2. Run “Regional Settings”.[...]
-
Page 160
ADAM-5560 Series User Man ual 152 3. Click “User Interface Language” folder and select “Chinese (T aiwan)” item. 4. Click “OK” to finish the change .[...]
-
Page 161
153 ADAM-5560 Series User Manu al Chapter 6 Miscellaneous Functions 5. Click “OK” to reboot the ADAM-5560. 6. The Language Interface has been changed correctly .[...]
-
Page 162
ADAM-5560 Series User Man ual 154 6.3 Example of Configuring T ouch Screen 1. Run the “T ouch Screen Config” utility . 2. Select COM port as COM3, for example.[...]
-
Page 163
155 ADAM-5560 Series User Manu al Chapter 6 Miscellaneous Functions 3. Click “OK” and reboot the ADAM-5560 syste m. 4. Enter “Control Panel”.[...]
-
Page 164
ADAM-5560 Series User Man ual 156 5. Run “S tylus” to set the properties. 6. Click “Recalibrate” but ton.[...]
-
Page 165
157 ADAM-5560 Series User Manu al Chapter 6 Miscellaneous Functions 7. Follow the instructions and use finger to press the t arget on the screen. 8. Follow the instructions and use finger to press the t arget on the screen.[...]
-
Page 166
ADAM-5560 Series User Man ual 158 9. Follow the instructions and use finger to p ress the target on the screen. 10. Follow the instructions and use fing er to press the targe t on the screen.[...]
-
Page 167
159 ADAM-5560 Series User Manu al Chapter 6 Miscellaneous Functions 11 . Follow the instructions and use finger to press the target on the scree n. 12. Press “Enter” key to accept the new settings.[...]
-
Page 168
ADAM-5560 Series User Man ual 160 13. Click “OK” to finish the recalibration. 6.4 Save and Upload Project Source 1. Open a project and click “Program Con trol Dialog”.[...]
-
Page 169
161 ADAM-5560 Series User Manu al Chapter 6 Miscellaneous Functions 2. Click “Download” button. Check the “Inclu de Sources” item and then click “Download”. 3. The “Upload” button will be activated w hen project source code has been downloaded correctly .[...]
-
Page 170
ADAM-5560 Series User Man ual 162 4. Click “Upload” button and then click “Project Source” to te st uploading source function. 5. Click “OK” to proceed with uploading the project source.[...]
-
Page 171
163 ADAM-5560 Series User Manu al Chapter 6 Miscellaneous Functions 6. Uploading project source has been finished. 6.5 Changing the Language Interface 1. Click “ExtrasOptions” item.[...]
-
Page 172
ADAM-5560 Series User Man ual 164 2. Select “T rad. Chinese” item. 3. Click “Apply” and “OK” buttons.[...]
-
Page 173
165 ADAM-5560 Series User Manu al Chapter 6 Miscellaneous Functions 4. Close Multiprog and then reloa d it. The Language Interface will change to T raditional Chinese correctly .[...]
-
Page 174
ADAM-5560 Series User Man ual 166[...]
-
Page 175
Chapter A A RS-485 Networks[...]
-
Page 176
ADAM-5560 Series User Man ual 168 A.1 RS-485 Networks EIA RS-485 is the industry’ s most widel y used bidirectional, balance d transmission line standard. It is specifically developed for industrial multi-drop systems that should be able to transmit and receive data at high rates o r over long distan ces. The specifications of the EIA RS-4 85 pro[...]
-
Page 177
169 ADAM-5560 Series User Manu al Chapter A RS-485 Networks Figure A.1 Daisychaining St ar Layout In this scheme the repeaters are connected to drop-down cab les from th e main wire s of the first segment. A tree structure is the result. This scheme is not recommended when using long lines since it will cause a serious amount of sig nal distortion [...]
-
Page 178
ADAM-5560 Series User Man ual 170 Random This is a combination of daisyc hain and hierarchical structure. Figure A.3 Random structure A.3 Line T ermination Each discontinuity in impedance causes reflections and distortion. Whe n a imped- ance discontinuity occurs in the transm ission line the immediate ef fect is signal reflection. This will lead t[...]
-
Page 179
171 ADAM-5560 Series User Manu al Chapter A RS-485 Networks Example: Each input of t he receivers has a nomin al input impedance of 18 k feeding into a diode transistor- resistor biasing network that is equ ivalent to an 18 k input resistor tied to a common mode voltage of 2.4 V . It is this configuration, which provides the large common range of t[...]
-
Page 180
ADAM-5560 Series User Man ual 172 A.4 RS-485 Dat a Flow Control The RS-485 standard uses a single p air of wires to send and receive data. This line sharing requires some method to control the direction of the dat a flow . RTS (Request T o Send) and CTS (Clear T o Send) are the most commonly used methods. Figure A.6 RS-485 Dat a Flow Control with R[...]
-
Page 181
Chapter B B Grounding Reference[...]
-
Page 182
ADAM-5560 Series User Man ual 174 B.1 Field Grounding and Shielding Applications Unfortunately , it’s impossible to finish a system integration t ask at one time. W e always meet some trouble in the field. A communicat ion network or system isn’t sta- ble, induced noise or equipment is damag ed or there are storms. However , the most usual issu[...]
-
Page 183
175 ADAM-5560 Series User Manu al Chapter B G rounding Reference B.2.2 The ‘Frame Ground’ and ‘Grounding Bar ’ Figure B.2 Grounding Bar Grounding is one of the most important issues for our system. Just like Frame Ground of the computer , this signal offers a reference point of the electronic circu it inside the computer . If we want to com[...]
-
Page 184
ADAM-5560 Series User Man ual 176 B.2.3 Normal Mode and Common Mode Have you ever tried to measure the volt age between a live circuit and a concrete floor? How about the voltage between neutral and a concrete floor? Y ou will get non- sense values. ‘Hot’ and ‘Neutral’ are just relational signals: you will get 1 10V AC or 220V AC by measuri[...]
-
Page 185
177 ADAM-5560 Series User Manu al Chapter B G rounding Reference What’s th e purpose of high volt age transmissions? W e have all seen high volta ge transmission towers. The power plant raises the volt age while generating the power , then a local power st ation steps down the voltage . What is the purpose of high volt- age transmission wires ? A[...]
-
Page 186
ADAM-5560 Series User Man ual 178 Figure B.8 Single Point Grounding (2) The above diagram shows you that a sing le point grounding system will be a more stable system. If you use thin cable for powering these devices, the end device will actually get lower power . The thin cable will consume the energy . B.3 Shielding B.3.1 Cable Shield Figure B.9 [...]
-
Page 187
179 ADAM-5560 Series User Manu al Chapter B G rounding Reference Figure B.10 Double Isolated Cable Double isolated cable Figure 10 is an example of a doub le isolated cable. The first isolating layer of spiraled aluminum foil co vers the conductors. The second isolation layer is several bare conductors that spiral and cross over the first shield la[...]
-
Page 188
ADAM-5560 Series User Man ual 180 B.3.2 System Shielding Figure B.1 1 System Shielding Never stripping too much of the plast ic cable cover . This is improper and can destroy the characteristics of the Sh iel ded-T wisted-Pair cable. Besides, the bare wire shield easily conduct s the noise. Cascade these shields together by soldering. Pleas[...]
-
Page 189
181 ADAM-5560 Series User Manu al Chapter B G rounding Reference Figure B.13 System Shielding (1) Shield connection (1) If you break into a cable, you might get in a hurry to achieve your goal. As in all electronic circuit s, a signal will use the p ath of least resis- tance. If we make a poor connection between the se two cables we will make a[...]
-
Page 190
ADAM-5560 Series User Man ual 182 B.4 Noise Reduction T echniques Isolate noise sources in shielded enclosures. Place sensitive equipment in shiel ded enclosure and away from computer equipment. Use separate gro unds between noise sources and signals. Keep ground/signal leads as short as possib le. Use T wisted and Shielded sign[...]
-
Page 191
Chapter C C Reference Documents[...]
-
Page 192
ADAM-5560 Series User Man ual 184 Following resources are help ful for underst anding how to use Multiprog Softwa re and IEC-61 131-3 programming languages. C.1 Reference Document s Multiprog Quick S tart Manual Multiprog User ’s Manual Mulitprog On-line Help ADAM-5550KW Series User ’s Manua l (under Advantech Multiprog CD-ROM ?[...]
-
Page 193
185 ADAM-5560 Series User Manu al Chapter C Reference Documents[...]
-
Page 194
www .advantech.com Please verify specifications be fore quoting. This guide is intended for reference purposes only . All product specifications are subj ect to change without notice. No p art of this publicati on may be reproduced in any form or by any means, electronic, photocopying, recording or otherwise, without prior written permis- sion of t[...]