A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion 5000 VA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion 5000 VA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion 5000 VA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of American Power Conversion 5000 VA should contain:
- informations concerning technical data of American Power Conversion 5000 VA
- name of the manufacturer and a year of construction of the American Power Conversion 5000 VA item
- rules of operation, control and maintenance of the American Power Conversion 5000 VA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion 5000 VA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion 5000 VA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion 5000 VA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion 5000 VA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    990-2690 0 2/2006 User Manual English APC Smart-UPS ® RT 3000/500 0 VA 200-240 VAC Tower/Ra ck Mount 3U Uninterrupti ble Power Supply[...]

  • Page 2

    [...]

  • Page 3

    1 Introduction The APC Sm art-UPS® RT is a h igh-perf ormance, unint erruptible pow er supply (UPS) that prov ides protection for electron ic equipment from utilit y po wer blackou ts, brownouts, sags and surges. The UPS filters small utilit y line fluctuations and isolates electronic equip ment from large disturbances by in ternally disconn ectin[...]

  • Page 4

    2 Wiring and Connecting the UPS 5000 VA XLI MO DELS O NLY : H ARDWIRING I NSTRUCTIONS • Wiring must be performe d by a qualif ied electrician. • Install a high magnetic 30/32 A utility circuit br eaker. • Adhere to all national and local electrical codes. • Use #10 A WG gauge (5 mm 2 ) w ir e. 1. Switch the utility circuit breaker OFF. 2. R[...]

  • Page 5

    3 C ONNECTING THE B ATTE RY MODULES AND A TTACHING THE F RONT B EZEL    [...]

  • Page 6

    4 B ASIC C ONNE CTORS serial com The serial connector is to be u sed for interf acing with APC Po w erChute software and terminal emulation software. Use only cables appro ved by APC. Any other interface cable will be incompatible with the UPS connector. normal bypass Manual bypass enables t he user to manually put connected eq uipment into bypass [...]

  • Page 7

    5 C ONNECTING E QUIPME NT AND P OWER TO TH E UPS 1. Connect equ ipment to the UPS (cables not included for XLJ/XLT/XLTW m odels). 2. Avoid using exte nsion cords. • 3000 VA XLJ/ XLT/XLI/XL TW and 5000 VA XLJ/ XLT/XLTW models : Using a pow er cord, plug the UPS into a two- pole, thr ee-wire, grounded receptacle only . • 5000 VA XLJ model s: To d[...]

  • Page 8

    6 O PERA TION Load S MART -U PS RT F RONT D ISPLAY Battery Charge Indicator Description Online The Online LED il luminates when th e UPS is drawing utility powe r and performing double con version to supply power to con nected equipment. On Battery The UPS is supplying battery po w er to the connected equi pment. Bypass The Bypass LED ill uminates [...]

  • Page 9

    7 Feature Function Cold Start When there is no utility po wer and the UPS is off, press and hold the button to power up th e UPS and connected equipment. The UPS will emit two beeps. During the second beep, release the bu tton. Self-Test Automatic: The UPS performs a s elf-test automatically when turned on, and ev ery two weeks thereafter (by defau[...]

  • Page 10

    8 U SER C ONFIGU RA BLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OW E R C HUTE SOFTW ARE , OPTIONAL S MA RT S LO T ACCESSO RY CARDS , OR T ER MI NAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRI PTION Automa tic Self-Tes t On start-up a nd eve ry 14 day s, thereafter On start-u p and every 7 days thereafter On s[...]

  • Page 11

    9 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OW E R C HUTE SOFTW ARE , OPTIONAL S MA RT S LO T ACCESSO RY CARDS , OR T ER MI NAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRI PTION Low Bypass Point 160 VA C Output Volta ge Settin g 200 VAC: 160 - 185 VA C 208 VAC: 160 - 190 VA C 220 VAC: 160 - 195 VA C 230 VAC : 160 - 20[...]

  • Page 12

    10 C ONNECTING THE EPO (E MERGENCY P OWER O FF ) O PTION The output pow er can be disabled in an emergen cy b y clos ing a switch connected to the EPO. Adhere to National and local electrical codes wh en wiring the EPO. The EPO switch is intern ally po wered by t he UPS for us e with non-po w ered switch circuit breakers. The EPO circuit is conside[...]

  • Page 13

    11 T ERMI NAL M OD E TO C ONFIGURE UPS P ARAMETE RS 3000 VA m odels: Terminal Mode is a menu driven interface that enables configuration of the UPS by users not wi shing to use P o werChut e ® soft ware or an o ptio nal Ne twork M ana geme nt Car d. Connect the serial cable to th e serial co m con nector on the back of the UPS. If Pow erChute sof [...]

  • Page 14

    12 5000 VA m odels: Terminal Mode is a menu driven interface that enables configuration of the UPS by users not using Pow erChute ® software or the ins talled Network Manageme nt Card interf aces. Connect the serial cable to the serial port on the back of th e UP S. If Pow erChute sof tware is not in stalled do not perform steps 1 and 5. 1. For W [...]

  • Page 15

    13 • Press 2 and ENTE R to change the Battery Settings. • Type in the number of external battery packs (four batt ery modules per pack ), and press E NTE R. (Num ber of packs: 1 = 1 S URT192XLBP, 2 = 2 SURT192XL BP etc.) • Press 3 and ENTER to accept the changes. • Press ESC multiple times (5) to return to the main menu. • Press 4 an d EN[...]

  • Page 16

    14 M AIN TE N AN C E AN D T RA NSPOR T Replacing the Battery Module This UPS has an easy to replace, h ot-swappable battery module. Replacement is a safe procedure, isolated from electrical hazards. You may leave the UPS and connected equipm ent on during the procedure. See y our dealer or contact APC at th e Web site, www.apc.com for infor m atio [...]

  • Page 17

    15 R EPLACING B ATTERY MODULES X Y Z [ ] ^ _  Disconnecting the Battery for Transport Alway s DISCONNECT THE B ATTERY(s) befo re ship ping in compliance with U.S. Departm ent of Transportation (DOT) and I ATA regulations. The battery(s) m ay remain in the UPS. 1. Shut down an d disconnect any equipment attach ed to the UPS. 2. Shut down and di[...]

  • Page 18

    16 T ROUBLESHOOTING , S ER VICE , AN D W A RRA NTY I N FORMA T ION Use the table below to solve minor installation and op eration problems. Refer to the AP C Web site, www.apc.com for assistan ce with complex UPS problems. P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS WILL NOT TURN ON Batt ery not conn ected p rop erly. Check t hat the b atter y con[...]

  • Page 19

    17 P ROBLEM AND P OSSI BLE C AUSE S OLUTION BYPASS LED ILLUM INA TES The bypass swi tch ha s been turne d on m anually or throu gh an acce ssory . If bypa ss is t he chosen mode of oper ation, ignore t he illum inated L ED. If bypa ss is not the chos en mode of op era tion move t he bypas s swit ch on the back o f the UPS , to th e normal posit ion[...]

  • Page 20

    18 Service If the UPS requires service do not return it to the dealer. Follow these s teps: 1. Revi e w the problems discussed in th e Troubleshoot ing section of this manual to eliminate common problem s. 2. If th e problem persis ts, contact APC Customer Support t hrough the APC Web site, www.apc.com . • Note the m odel number of the UPS, the s[...]

  • Page 21

    19 R EGULA TOR Y Regulatory Agenc y Approvals a nd Radio F reque ncy Warnings 200, 208, 22 0, 230, 240 V MODELS This e quipm ent has bee n teste d and f ound to com ply with the limits f or a Class A digi tal de vice, p ursua nt to part 15 of t he FCC Ru les. Th ese limi ts are des igned t o provid e reason able p rotect ion a gainst ha rmfu l inte[...]

  • Page 22

    20 Declaration of Conformity[...]

  • Page 23

    21 A PC Worldwi de C ustomer Support Custom er support for th is or any other APC produ ct is available at n o charge in any of the following wa ys: • Refer to th e APC Web site to access documents in the APC Knowledg e Base and to submit customer su pport requests . • www.apc.com (Corporate H eadquarters) Connect to localized A PC Web sites fo[...]