Go to page of
Similar user manuals
-
Power Supply
American Power Conversion 10000 VA
21 pages 0.39 mb -
Power Supply
American Power Conversion SL-300TFX
27 pages 0.73 mb -
Power Supply
American Power Conversion SYMSTRF-PD
75 pages 5.52 mb -
Power Supply
American Power Conversion 990-2485
10 pages 1.42 mb -
Power Supply
American Power Conversion AP9554
68 pages 1.74 mb -
Power Supply
American Power Conversion VS 100
54 pages 2.22 mb -
Power Supply
American Power Conversion 120VAC
27 pages 0.73 mb -
Power Supply
American Power Conversion 10-40kW 208/480V
31 pages 1.1 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion 5000I, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion 5000I one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion 5000I. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Power Conversion 5000I should contain:
- informations concerning technical data of American Power Conversion 5000I
- name of the manufacturer and a year of construction of the American Power Conversion 5000I item
- rules of operation, control and maintenance of the American Power Conversion 5000I item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion 5000I alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion 5000I, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion 5000I.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion 5000I item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
990-7032A , Rev ision 3 7/01 APC Smart-UPS Uninterruptible Pow er Supply Model 5000I User’s Manual[...]
-
Page 2
Entire con tents copyrig ht ©1999 by A merican Pow er Conv ersion. A ll rig hts res erved. Reprodu ction i n w hole or in part w ithou t permis sion is proh ibited. Smart- UPS is a registered tradem ark of APC. All oth er trademark s are the property of their res pectiv e ow ners. 990-7032A , Rev ision 3 7/01[...]
-
Page 3
990-7032A , Rev ision 3 7/01 Smart UPS Safety Guide English This Sa fety G uide contains importa nt instructions tha t should be f ollowe d during insta llation and m aintenanc e of the APC equipm ent and ba tteries . It is intended f or APC customer s who setup, install, re locate, or m aintain A PC equipment. Handling Safety • = Be ca ref ul. D[...]
-
Page 4
[...]
-
Page 5
990-7032A , Rev ision 3 7/01 i Table of Contents Introduction ................................................................................................................... ............................................................................. 1 Unpackin g .................................................................................[...]
-
Page 6
[...]
-
Page 7
990-7032A , Rev ision 3 7/01 1 Introduction About Your New UPS This Uninte rruptible Powe r Supply ( UPS) is desig ned to preve nt blackouts , brownouts , sags and surge s fr om r eaching your co mputer and other va luable elec tronic equipm ent. This UPS also filte rs out small utility line f luctuations a nd isolates y our equipm ent from l arg e[...]
-
Page 8
990-7032A , Rev ision 3 7/01 2 Inst allation Installing your UPS r equires six step s: 1. Position the UPS in the desired locatio n. For rack m ount units this m ay include installing th e rails into the rack. 2. Hardw ire the electrical conn ection on th e input side (m us t be done by an authorized electrician ). 3. Inst all the bat teries. This [...]
-
Page 9
990-7032A , Rev ision 3 7/01 3 Determine the Loca tion of the UPS in the Rack (continued) 1. Determ ine w here in the rack y ou’ ll m ount th e UPS. The SU5000 requires a space of 5U. Some rack s have tick mark s to indicate the U-spaces. 2. Usin g the m oun ting tem plate prov ided (part nu mber 990- 0195), identify and mark the correct moun tin[...]
-
Page 10
990-7032A , Rev ision 3 7/01 4 The 5000 VA m odel s (without batteries i nstalled) req uire two people to li ft due to their weight. Load the UPS in to the Rack Supportin g th e UPS from the f ront and back , carefully align the u nit w ith the rails. Slide the UPS into position. Attach the Mounting Bra ckets to the Rack Use the ornament al screws [...]
-
Page 11
990-7032A , Rev ision 3 7/01 5 3. Install the Bat teries The battery com partmen t is accessed f rom th e front panel of the UPS. The 5000 VA un it requires fou r battery pack s (each pack cons ists of four in dividu al batteries ). Note: Graphics are not drawn to scale. They are s hown for reference only. 1. Rem ove the f ront bezel by grasping th[...]
-
Page 12
990-7032A , Rev ision 3 7/01 6 Initial S tartu p Rear Views 5000 VA Tower Model 5000 VA Rack Mount Model Charge the ba ttery The UPS charges its battery w henever it is connected to utility pow er. T he battery w ill charge fully during the f irst four hours of norm al operation. Do not expect full runtim e d uring th is initial charge period. Conn[...]
-
Page 13
990-7032A , Rev ision 3 7/01 7 Low Battery War ning Interval By default, th e low battery warning occu rs wh en there are approximately two mi nutes of on- battery run time rem aining. This may not be enough time to gracefully shut down som e pro tected computer systems. To change the w arning interv al, press the rear panel configuration button w [...]
-
Page 14
990-7032A , Rev ision 3 7/01 8 Operating Instructions Switch On — Switch Off With the UPS p lugged in, press a nd re lease the large up per on/test button t o supp ly power to the load s. T he loa ds are imm ediately pow ered w hile the UPS beeps and perf orms a s elf-tes t. Press and release the s mall, low er off button to tu rn off pow er to t[...]
-
Page 15
990-7032A , Rev ision 3 7/01 9 Load Bar Gra ph 85% 67% 50% 33% 17% The 5-LED display on the left of th e front panel repres ents the pow er drawn f rom th e UPS as a percentage of total capacity. For exam ple, if three LEDs are lit, th e load is drawing betw een 50 % and 67% of the UPS’s capac ity. If all five LEDs light, thoro ughly test y our c[...]
-
Page 16
990-7032A , Rev ision 3 7/01 10 Replacing the Batter y This UPS has an easy to replace hot-sw appable battery. The battery compartm ent is located on the front pan el for easy access. Battery replacement is a safe procedu re, isolated from electrical hazards. You m ay leave the UPS and loads on for the follow ing procedure. See y our dealer or call[...]
-
Page 17
990-7032A , Rev ision 3 7/01 11 User Configur ation Items Note: Setti ng t hese it ems requ ires op tion al software o r hardw are. Fun ctio n Factory Defau lt User Selectabl e Cho ices Descriptio n Autom atic Self-Test Every 14 day s (336 hou rs) Every 7 days (168 hours), On Startup On ly, No Self -Test Se ts the inte rval a t w hic h the UPS will[...]
-
Page 18
990-7032A , Rev ision 3 7/01 12 Sp ecifications Acceptable input v oltage 0 - 325 VAC Outpu t vo ltage 196 - 253 VAC Inpu t protectio n Rese ttable circuit bre aker Frequenc y limits (on-l ine oper ati on) 47 - 63 Hz Tr an sf er t ime 2 ms t ypi c al , 4 ms ma xi mum Maxim um load , total 5000 VA/3750 W On-batte ry o utput v oltage 220, 225, 230, o[...]
-
Page 19
990-7032A , Rev ision 3 7/01 13 Regulatory A gency A pprovals N 3 94 B ME 61[...]
-
Page 20
990-7032A , Rev ision 3 7/01 14 T roubleshooting Use the ch art below to solve m inor UPS installati on problem s. Contact APC Technical S upport Staf f for ass istance w ith complex UPS problem s. See AP C Contact Inf orma tion , page 15, for a location near y ou. Problem and Possible Cause Solution UPS will not turn on. • = ON button not pushed[...]
-
Page 21
990-7032A , Rev ision 3 7/01 15 Service If the UPS requires service do not return it to the dealer! Follow these steps: 1. Rev iew the problem s discuss ed in Tr oubleshoot ing , page 14, to eli min ate com mon problems . 2. Verify that no circuit breakers are tripped. A tripped circuit breaker is th e most com mon UPS problem! 3 . I f th e p r ob [...]
-
Page 22
990-7032A , Rev ision 3 7/01 16 A ppendi x A : T y pes of Racks and M ounting Hardw are This appendix describes t he hardw are required for the di fferen t ty pes of rack s and descri bes the ty pe of racks th at ma y be used in y our industry . All APC Rack Mou nt un its are shipped ready for 19-inch w ide EIA/IEC rack cabin ets. Refer to th e ins[...]
-
Page 23
990-7032A , Rev ision 3 7/01 17 A ppendi x B: T ransporting Y our Smart-UPS Follow these gui delines if y ou need to ship the UPS to another location . These guidelines apply w hether you are transporting the UPS alone, rack m o unted in an equipm ent cabinet, or installed in a s ystem . Caution: Alw ays DISCONNECT THE BATTERIES bef ore shipping t [...]