Go to page of
Similar user manuals
-
Power Supply
American Power Conversion AP9341
24 pages 0.57 mb -
Power Supply
American Power Conversion SYMSTRF
75 pages 5.52 mb -
Power Supply
American Power Conversion MX06 50
37 pages 2.01 mb -
Power Supply
American Power Conversion AP9554
68 pages 1.74 mb -
Power Supply
American Power Conversion 2200 VA
17 pages 0.82 mb -
Power Supply
American Power Conversion 8000VA
21 pages 0.45 mb -
Power Supply
American Power Conversion HS 500
4 pages 1.66 mb -
Power Supply
American Power Conversion 240-320kW400V
32 pages 2.32 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion SUDP4000I, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion SUDP4000I one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion SUDP4000I. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Power Conversion SUDP4000I should contain:
- informations concerning technical data of American Power Conversion SUDP4000I
- name of the manufacturer and a year of construction of the American Power Conversion SUDP4000I item
- rules of operation, control and maintenance of the American Power Conversion SUDP4000I item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion SUDP4000I alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion SUDP4000I, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion SUDP4000I.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion SUDP4000I item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
990-1007A , Rev ision 2 9/99 Smart-UPS DP Uninterruptible Pow er Supply Models SUDP4000I, SUDP6000I, SUDP8000I, SUDP10000I User’s Manual[...]
-
Page 2
Entire con tents copyrig ht ©1999 by A meri can Pow er Conv ersion. A ll rig hts res erved. Reprodu ction i n w hole or in part with out permission is prohibited. Smart- UPS is a registered trademark of A PC. All other trademark s are the property of their respective ow ners . 990-1007A , Rev ision 2 9/99[...]
-
Page 3
990-1007A , Rev ision 2 9/99 Smart-UPS DP Quick Reference Guide English About Your New UPS This Uninterruptible Power Supply (UPS) prevents blackouts, brow nouts, s ags an d surges from reaching you r comput er and other valuable electronic equipm ent, filters out u tility line fluctu ations, and is olates y our equipm ent from distu rbances by act[...]
-
Page 4
[...]
-
Page 5
990-1007A , Rev ision 2 9/99 i Table of Contents Safety ......................................................................................................................................................................................................... 1 Handling Saf ety .........................................................................[...]
-
Page 6
990-1007A , Rev ision 2 9/99[...]
-
Page 7
990-1007A , Rev ision 2 9/99 1 Safety This Sa fety G uide contains importa nt instructions tha t should be f ollowe d during insta llation and m aintenanc e of the APC equipm ent and ba tteries . It is intended f or APC customer s who setup, install, re locate, or m aintain A PC equipment. Handling Safety • Be ca ref ul. Do not lift hea vy loads [...]
-
Page 8
990-1007A , Rev ision 2 9/99 2 Initial Insp ection Inspection Inspect the UPS upon receipt. Notif y th e carrier and dealer if th ere is damag e. The packaging is recyclable; sav e it for reuse or dis pose of i t properly . Unpacking Move the UPS, in its s hipping pack age, as close to th e desired location as poss ible. Then follow these in struct[...]
-
Page 9
990-1007A , Rev ision 2 9/99 3 Placement Sm a r t - U P S D P Sm a r t - U P S D P Sm a r t - U P S D P Install the UPS in a protected area th at is free of ex cessive dust an d has adequate air f low . Suff icient cooling mu st be ensu red by a m ini mu m of 150 mm f ree space from the ventilation slots on th e back, and 200 m m f rom th e ventila[...]
-
Page 10
990-1007A , Rev ision 2 9/99 4 Externa l Connections Notes: As a standar d, the S mart-UPS DP is made for sing le-phase connecti on. Due to the leakage current of 3 .5 t o 10 mA, the Smart-UPS DP mu st alw ay s be grounded according to local reg ulations. Mains Connections Make these connections only if no optional equipment (see the Optiona l Equi[...]
-
Page 11
990-1007A , Rev ision 2 9/99 5 Rear Views F 0 0 1 M a i n s F 0 0 1 M a i n s 16) 15) 14) 13) 12) 11) 10) 9) 8) 7) 6) 5) 4) 3) 2) 1) A DC AH MIN. : STO RED E NERG Y TIME OU TPUT : INPUT : AH V DC / V / 2. REPLACEMENT 1. REPLACEMENT INSTA LLE D YEAR MONTH REPLACEMENT OF B AT TE RI E S KG. WEIGHT: S. NO. : TYPE: P .NO. : RECORD THE DATE OF RE PLACEME[...]
-
Page 12
990-1007A , Rev ision 2 9/99 6 Common Fault The function of the com mon fault relay is factory preset. For ch anging the factory setting, please contact y o ur local dealer. Principa l Diagram (common fault) 1 NC 2 NO 3 Com 4 Com Data: Relay contacts - ohmi c load DC m in./m ax.: 12V DC 20m A/ 60V DC 1A AC m in./max.: 12V AC 20mA/ 250V AC 8A Comput[...]
-
Page 13
990-1007A , Rev ision 2 9/99 7 14 NC1 15 NC1 NO1 2 COM1 NO1 COM1 CHGND X005 EPO RELAY CONNECTOR 16 NC2 17 NC2 NO2 4 COM2 NO2 COM2 CHGND 18 NC3 19 NC3 NO3 6 COM3 NO3 COM3 CHGND 20 NC4 21 NC4 NO4 8 COM4 NO4 COM4 CHGND ON/OFF RELAY BYPASS OPERATION RELAY BATTERY OPERATION RELAY BATTERY LOW WARNING RELAY EPO RELAY PC BOARD RELAY FUNCTION +V 11 12 PSU_P[...]
-
Page 14
990-1007A , Rev ision 2 9/99 8 Optional Equipment I nst allation Galvanic Isolation T ransformer The galvanic is olation transf ormer can be delivered for one- or two- phase conn ection. When con necting a Sm art-UPS DP and galvanic isolation transf ormer, the A C bus and the w ires for the thermo sw itch m ust be mounted. Please follow the instruc[...]
-
Page 15
990-1007A , Rev ision 2 9/99 9 Standard S ystem With Is olating Trans form er (400 V) System Ma ins Fuse* (Fm ) Input Cable Trans form er Input Cable UPS Output Cable UPS 4kV 16A 3x2.5mm ² 3x6m m² 3x4 mm ² 6kV 25A 3x6 m m² 3x16 m m² 3x10 m m² 8kV 32A 3x10 mm ² 3x16 mm ² 3x10 mm ² 10kV 40A 3x10 m m² 3x16 m m² 3x16 m m² *Di n g l T yp e s[...]
-
Page 16
990-1007A , Rev ision 2 9/99 10 External Service Bypass Panel ( SBP) Note: The Sm art-UPS DP must only be conn ected by service bypass panels (SBPs) man ufactured by APC. If SBP s other than th ose manufactured by A PC are us ed, the UPS s yst em m ay be damaged and the w ar ranty give n by AP C is re pealed. During the installation of the service [...]
-
Page 17
990-1007A , Rev ision 2 9/99 11 UPS N L N L INPUT CABLE SBP MAINS L N PE LOAD L N OUTPUT CABLE SBP SBP L N L N Input cable UPS Output cable UPS Fm Fo 1 2 3 4 MBS CONTROL SBP CABLE X010 1 2 3 4 External Service Bypass Panel an d Galvan ic Isolation T ransformer If both the extern al service bypass panel and the galv anic isolation transform er are i[...]
-
Page 18
990-1007A , Rev ision 2 9/99 12 Standard S ystem With Is olating Trans form er (400 V) And SBP System Ma ins Fuse* (Fm ) Input Cable Trans form er Input Cable UPS Output Cable UPS 4kV 16A 3x2.5mm ² 3x6m m² 3x6 mm ² 6kV 25A 3x6 m m² 3x16 m m² 3x10 m m² 8kV 32A 3x10 mm ² 3x16 mm ² 3x10 mm ² 10kV 40A 3x10 m m² 3x16 m m² 3x16 m m² *Di n g l[...]
-
Page 19
990-1007A , Rev ision 2 9/99 13 Operating Instructions Switching On F 0 0 1 M a i n s Switch on the m ains fuse on th e rear of the UPS. The Smart-UPS DP will perform a self-check ending w ith the LED display sh owing red/yellow /green, m eaning that th e unit is fu nctioning properly. The unit perform s a self-t est autom atically w hen turned on [...]
-
Page 20
990-1007A , Rev ision 2 9/99 14 LEDs The LED bar on the f ront of th e unit gi ves inf ormation by m eans of color and size of the bar. [ MUTE ] Bat tery Oper . Che ck Ba tt er y Green Y ellow No rma l Ope r . Recharging Bat t . [ 100 % ] [ 50 % ] [ 25 % ] [ 75 % ] Overload Red Bypass / Failure The gener al meaning is : Green = Okay . Yellow = Okay[...]
-
Page 21
990-1007A , Rev ision 2 9/99 15 Batteries A utomatic Battery Check The battery test is autom atically carried out every third month, if the au tomatic battery test function is set. The battery tes t starts w hen the batteries are fu lly ch arged. There is no alarm given for the battery operation and the dis play sh ow s norm al operation. Manual Ba[...]
-
Page 22
990-1007A , Rev ision 2 9/99 16 Sp ecifications SUDP4000I SUDP 6000I SUDP8000I SUDP10000I Acceptable input v oltage 220/230/240V +10%/-15% no rmal o peration ± 10% by pass operatio n Inpu t v oltage (on-lin e ope ration) 220/230/240 VAC 230 vo lt ou tput rang e 220/230/240 VAC Nom inal input frequ ency 50 or 60 Hz Inpu t protectio n Rese ttable ci[...]
-
Page 23
990-1007A , Rev ision 2 9/99 17 Regulatory A gency A pprovals N 3 94 B ME 61 geprüfte Sicherheit[...]
-
Page 24
990-1007A , Rev ision 2 9/99 18 A PC Contact Information Internet ht tp : / / www. a p cc . c o m Latin A merica, South A merica Arge ntina................ 0800.9.APCC (0800.9.2722) Mexico ............................... 95.800.804.4283 Brazil...................... 0800.12.72.21 Ur uguay.............................. 000.413.598.2139 Colom bia ....[...]