A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion UXI/UXICH, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion UXI/UXICH one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion UXI/UXICH. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Power Conversion UXI/UXICH should contain:
- informations concerning technical data of American Power Conversion UXI/UXICH
- name of the manufacturer and a year of construction of the American Power Conversion UXI/UXICH item
- rules of operation, control and maintenance of the American Power Conversion UXI/UXICH item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion UXI/UXICH alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion UXI/UXICH, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion UXI/UXICH.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion UXI/UXICH item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
990-2688A 02/2006 User Manual English APC Smart-UPS ® RT – UXI/UXICH 3000/500 0 VA 220/ 230/240 VAC Tower/Ra ck-Mount 3U Uninterrupti ble Power Supply[...]
-
Page 2
[...]
-
Page 3
1 Introduction The APC Sm art-UPS® RT is a h igh-perform ance, uninterruptibl e power su pply (UPS) th at provides protection for electron ic equipment from utility po wer blackou ts, brownouts, sags an d surges. The UPS filters small utilit y line fluctuations and isolates electronic equip ment from large disturbances by in ternally disconnect in[...]
-
Page 4
2 A TTACH THE B EZEL TO THE UPS H ARDWIRING I NST RUCTIONS 5000 VA MODE LS O NLY : • Wiring must be performed by a qualified el ectrician. • Adhere to all national and local electrical codes. • Install a high magnetic 30/32 A utility circ uit breaker • Use #10 A WG gauge (5 mm 2 ) w i re. 1. Switch the utility circuit breaker OFF. 2. Remove[...]
-
Page 5
3 B ASIC C ONNE CTORS serial com Power management sof t ware an d interface kits can be used w ith the UPS. Use only cables appro ved by APC. Any other interface cable will be incompatible with the UPS connector. normal bypass Manual bypass enables t he user to manually put connected eq uipment into bypass mode. EPO te rminal Emergency Power Off te[...]
-
Page 6
4 C ONNECT THE E XTERNAL B ATTERIES Ba ttery Safe ty Read and adhere to the follow ing warnings when installing or serv icing the external batteries. Failure to observe these warn ings may result in serious inju ry, death or damage to th e equipment. W ARNINGS • Do not attempt to install or service external batteries alo ne. A qualified electrici[...]
-
Page 7
5 T HIRD P ARTY B ATTERY S OLUTION Batteries mu st be Sealed Lead-Aci d type. Use 50 A, 250 VD C fuses with an Interrupt rating of ≥ 20,000 A . Ensure that the extern al batteries are w ired prior to connecting the batteries to the UPS. If using a non-APC battery pack , a 192 V battery string should be w ired to the UPS us ing the enclosed batter[...]
-
Page 8
6 C ONNECT E QUIPMENT AND P OWER TO THE UPS 1. Connect equ ip ment to the UPS. 2. 3000 VA models : Using a po wer cord, plug the UPS into a two-pole, three-wire, g ro unded receptacle only. Avoid using ext ension cords. 3. Turn on all conn ected equipment. T o use the UPS as a master ON/OFF switch, ensure all connected equ ip ment is sw itc hed ON.[...]
-
Page 9
7 O PERA TION Load S MART -UPS RT F RONT D ISPLAY Battery Charge Indicator Description Online The Online LED il luminates when the U PS is drawing util it y po w er and perform ing double con version t o supply power to conn ected equipment. On Battery The UPS is supplying battery po w er to the connected equipm ent. Bypass The Bypass LED ill umina[...]
-
Page 10
8 Feature Function Cold Start This is not a normal conditio n. When there is no utility po w er and the UPS is off, press and hold the button to power up th e UPS and connected equipment. The UPS will emit two beeps. During the second beep, release the button. Self-Test Automatic: The UPS performs a s elf-test automatically when turned on, and ever[...]
-
Page 11
9 U SER C ONFIGU RAB LE I TEM S N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OW E R C HUTE SOFTW ARE , OPTIONAL S MA RT S LO T ACCESSO RY CARDS , OR T ERMINAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRI PT ION Automa tic Self-Test On start-up and eve ry 14 days , thereafter On start-u p and every 7 days thereafter On sta[...]
-
Page 12
10 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OW E R C HUTE SOFTW ARE , OPTIONAL S MA RT S LO T ACCESSO RY CARDS , OR T ERMINAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRI PT ION Low Bypass Point 160 VA C Output Volta ge Settin g 200 VAC: 160 - 185 VA C 208 VAC: 160 - 190 VA C 220 VAC: 160 - 195 VA C 230 VAC : 160 - 20[...]
-
Page 13
11 C ONNECT THE EPO (E MERGENCY P OWER O FF ) O PTION The output pow er can be disabled in an emergency by clos ing a switch connected to the EPO. Adhere to national and local electrical codes wh en wiring the EPO. Wiring must be performed by a qualified electrician. The EPO switch is intern ally po wered by the UPS for use with non-powered sw itch[...]
-
Page 14
12 T ERMI NAL M OD E TO C ONFIG URE UPS P ARAMETER S Terminal Mode is a menu driven interface that enables configuration of the UPS and allows confi gura tion b y user s who do no t wis h to use P ower Chute soft ware o r an o ptio nal W eb car d. Connect the serial cable f ro m the computer to th e serial com connector on the back o f the UPS. If [...]
-
Page 15
13 M AIN TE N AN C E AN D S ERVICE I NFORMA T ION Battery Repla cement See your dealer or contact A PC at the Web site, www.apc.com for information on replacement battery modules. Service If the UPS requires service do not return it to the dealer. Follow these s teps: 1. Revi e w the probl ems discuss ed in the Troubles hooting section of this manu[...]
-
Page 16
14 T ROUBLESHOOTING Use the table below to solve minor installation and op eration problems. Refer to the APC W eb site, www.apc.com for assistan ce with co m ple x UPS problems. P ROBLEM AND P OSSI B LE C AUSE S OLUTION UPS WILL NOT TURN ON Batt ery not conn ected p roper ly. Check t hat the b atter y connectors are ful ly engage d. butt on not pu[...]
-
Page 17
15 P ROBLEM AND P OSSI B LE C AUSE S OLUTION BYPASS LED ILLUM INATE S The bypass swi tch has be en turne d on m anually o r through an acce ssory . If bypa ss is t he chosen mode of oper ation, i gnore the illuminate d LED. If bypa ss is not the chos en mode of op erat ion move the b ypass switc h on the back o f the UPS, to the no rmal position. F[...]
-
Page 18
16 R EGULA TOR Y A ND W AR R AN T Y I NFORMA T I ON Regulatory Agenc y Approvals a nd Radio F reque ncy Warnings 220, 230, 24 0 V MODEL S This e quipme nt has been te sted a nd foun d to com ply w ith the lim its for a Cl ass A dig ital de vice, p ursua nt to Part 15 o f the FCC ru les. Th ese lim its are desi gned to pr ovide r easonab le prot ect[...]
-
Page 19
17 Declaration of Conformity[...]
-
Page 20
18 A P C W orl dwide Customer Support Custom er support for th is or any othe r APC product is available at no charg e in any of the foll o wing wa ys: • Refer to th e APC Web site to access documents in the APC Knowledge Base and to s ubmit customer su pport requests . • www.apc.com (Corporate H eadquarters) Connect to localized A PC Web sites[...]