Go to page of
Similar user manuals
-
Power Supply
APC BE600N-BR
4 pages 0.07 mb -
Power Supply
APC NEMA 5 15R 320J
2 pages 0.32 mb -
Power Supply
APC 150
28 pages 1.06 mb -
Power Supply
APC 60-80kW
80 pages 4.38 mb -
Power Supply
APC 230 Vac
17 pages 0.36 mb -
Power Supply
APC RS 1000
2 pages 0.84 mb -
Power Supply
APC BK600EI
40 pages 0.29 mb -
Power Supply
APC 990-2233A
19 pages 0.87 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of APC 750 VA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC 750 VA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of APC 750 VA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of APC 750 VA should contain:
- informations concerning technical data of APC 750 VA
- name of the manufacturer and a year of construction of the APC 750 VA item
- rules of operation, control and maintenance of the APC 750 VA item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC 750 VA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC 750 VA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC 750 VA.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the APC 750 VA item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Operation Manual Smart-UPS ® Uninterruptible Power Supply 750/1000/1500/2200/3000 V A T ower 100/120/230 V ac 500 V A T ower 100 V ac[...]
-
Page 2
[...]
-
Page 3
1 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Overview Product Description The APC ® by Schneider Electric Smart-UPS ® 500 V A to 3000 V A T ower is a high perform ance uninterruptible power supply (UPS). It provides pr otection for electronic equipment from utility power blackouts, brownouts, sags, and surges, sm[...]
-
Page 4
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 2 Product Overview Front p anel features Rear p a nel features 500 V A to 15 00 V A models Display interface 500/750/1000/1 500 V A 2200/3000 V A Bezel Battery Internal battery connector USB port 500/750 V A 100 V ac 750 V A 120 V ac 750 V A 230 V ac [...]
-
Page 5
3 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Rear p a nel features 2200 V A and 30 00 V A models Inst allation For UPS installation information, refer to the Smart-UPS Installati on Guide 750/10 00/1500/2200/300 0 V A 100/120/230 V ac, 500 V A 100 V ac T ower, that is included with the UPS. The Installation guide i[...]
-
Page 6
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 4 Operation Connect Equipment Note: The UPS will char ge to 90% capacity in th e first four and a half hours of normal operation for the 2200/3000 V A 100 V ac model or the first three hours of normal operation for all other models . Do not expect full battery runtime capabi[...]
-
Page 7
5 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Display Panel Using the display interface Use the U P and D OWN keys to scroll through th e main menu options. Press E NTER to view the sub-menus under each main menu option. Press E SCAPE to exit a sub-menu and return to a main menu. St andard menus The Standard menus a[...]
-
Page 8
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 6 Advanced menus The Advanced menus provid e additional options for the UPS and are available only if the display interface is configured to use the Advanced menus. Menu General Functions St a t u s V iew detailed UPS information: • Operating Mode • Effic iency • Load [...]
-
Page 9
7 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Configuration UPS Settings St art-up Settings Configure these settings at initial start-up, using the di splay interface. As an a lternative, configuration can be performed using APC PowerChute ® software. Note: During start-up, use the display interface to configure th[...]
-
Page 10
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 8 Low T ransfer Point 100 V ac: 92 V ac 86 V ac - 92 V ac Set the transfer point lower if the utili ty volt age is chronically low and the connected equipment can tolerate this cond iti on.T his setting may also be ad juste d using the power quality setting. Note: Use the Ad[...]
-
Page 11
9 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Main Outlet Group and Switched Outlet Group Overview The Main Outlet Group and the Switched Outlet Grou p can be configured to independently turn of f, turn on, shut down, and reboot connecte d equipment. (These features are not available on the 500 V A or 750 V A units.[...]
-
Page 12
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 10 Customize the Main and Switched Outlet Groups Use the Configuration menus to change the Main Outlet Gro up and the Switched Ou tlet Group settings. Network Management Card Settings These settings are available only on units that have a Ne twork Management Card (NMC) and a[...]
-
Page 13
11 Smart-UPS 750/1000/1 500/22 00/3000 VA 1 00/120/2 30 Vac 50 0 VA 100 Vac Tower Emergency Power Off Overview The Emergency Power Off (EPO) optio n, is a safety feature that will immediately disconnect all connected equipment from utility po wer . The UPS will immediately shut down and will not switch to battery powe r . Adhere to all national and[...]
-
Page 14
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 12 T r oubleshooting Prob lem and Possible Cause Solution The UPS will not turn on or there is no output. The unit has not been turned on. Press the ON key once to turn on the UPS. The UPS is not connected to utility power . Be sure the power cabl e is securely connected to [...]
-
Page 15
13 Smart-UPS 750/1000/1 500/22 00/3000 VA 1 00/120/2 30 Vac 50 0 VA 100 Vac Tower Service If the unit requires service, do not retu rn it to the dealer . Follow these steps: 1. Review the T r ou bleshooting section of the manual to eliminate common problems. 2. If the problem persists, contact APC Cust omer Support through the APC W eb site, www .a[...]
-
Page 16
Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 14 Smart-UPS Factory W arranty LIMITED W ARRAN TY American Power Conversion (APC ) warrants its Smart-UPS (Produc ts) to be free from defects in materials and workmanship for a period of three (3) years, excluding the batteries, which are warranted for two (2) years from dat[...]
-
Page 17
[...]
-
Page 18
2/2012 990-3534C APC W orldwide Customer Support Customer support for this or any other APC product is available at no char ge in any of the follow i ng ways: • V isit the APC W e b site to acce ss docume nts in the APC Knowledg e Base and to submit customer support requests. – www .apc.com (Corporate Headquarters) Connect to localized APC W eb[...]