APC SMX750 VA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of APC SMX750 VA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC SMX750 VA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of APC SMX750 VA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of APC SMX750 VA should contain:
- informations concerning technical data of APC SMX750 VA
- name of the manufacturer and a year of construction of the APC SMX750 VA item
- rules of operation, control and maintenance of the APC SMX750 VA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC SMX750 VA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC SMX750 VA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC SMX750 VA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the APC SMX750 VA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Oper ation Man ual Smart -UPS X U nin terrup tibl e Power Suppl y Rack- Mou nt 2U SMX750 V A SMX1000 V A SMX 1500 V A 120 V ac 230 V ac[...]

  • Page 2

    [...]

  • Page 3

    1 Smart- UPS X 7 50/1000/1500 VA 12 0/230 Va c Rack - Mount 2 U Product Description The APC ™ by S chne ider Electri c S ma rt-UPS ™ is a high performance unint errupti ble power suppl y (UPS). The UPS provi des prote ction for electroni c equipment from util ity po w er b lackou ts , brownouts , sags, and surges , small utili ty power fluctua [...]

  • Page 4

    Smart-UPS X 750/10 00/1 500 VA 120/230 Vac Rack-Mount 2U 2 Product Overview Front P a n e l Feature s Rear Pane l Featur es  Batte ry  Batte ry con n ec tor  Di sp lay i nte rfa ce  Beze l  SmartS lot 12 0 V ac  Extern a l ba ttery pa ck conne ctor  Outlet s  EPO connector  USB port  Serial port  Chassi s grou nd s [...]

  • Page 5

    3 Smart- UPS X 7 50/1000/1500 VA 12 0/230 Va c Rack - Mount 2 U S pecifi cations En vir onm ental Sp ec ifica tion s For addi tional specif ication s , re fer to the APC by Schneider Elect ric W eb si te at www .apc. com. Inst allation UPS Fo r U PS in stal la tio n info rm ati on , ref er to the S ma rt-U PS X Ins ta llat ion Gui de th at is inc l[...]

  • Page 6

    Smart-UPS X 750/10 00/1 500 VA 120/230 Vac Rack-Mount 2U 4 Operat ion Conn ect Eq uipmen t to the U PS Note: The UPS wil l ch a rge to 9 0% capac ity in the f irst th ree ho urs of no rmal ope ra tion . Do not expect full ba ttery runtime capability during thi s initial charge period. 1. Connect equipme nt to the out lets o n the rear pa nel o f th[...]

  • Page 7

    5 Smart- UPS X 7 50/1000/1500 VA 12 0/230 Va c Rack - Mount 2 U Displa y Panel Ov ervi ew Usin g the disp lay inte r fa ce Us e th e UP / DOW N arrow but ton s to scrol l th rough the mai n menu op tio ns. Press EN TER to vi ew the s ubmenus und er each mai n men u o ption . Pre ss ESC APE to ex it a submenu and ret urn to a main menu. St andard m [...]

  • Page 8

    Smart-UPS X 750/10 00/1 500 VA 120/230 Vac Rack-Mount 2U 6 Ad vanc ed me nu s The Advan ce d men us provide additi ona l options for the UPS and ar e a va il able only if the di s play interfa ce i s configu red to use the Adva nced menus. Me nu Ge neral Fu nction s St a t u s V iew de tailed info rm a ti on about the UPS: •E n e r g y m e t e r [...]

  • Page 9

    7 Smart- UPS X 7 50/1000/1500 VA 12 0/230 Va c Rack - Mount 2 U Config uration UP S Sett ings St art up settings Configure the s e se ttings at i nitial start up, us ing t he dis play inte rface or PowerChut e ™ software. Note: Dur ing sta rt up, use t he di splay i nterface to c onfigure the s e se ttings. If no thing is se lected, t he unit wil[...]

  • Page 10

    Smart-UPS X 750/10 00/1 500 VA 120/230 Vac Rack-Mount 2U 8 Controlla ble Out le t Group s Ov ervi ew The rear pane l of the UPS has mul ti ple outl et s, some are grouped i nto Control la ble Outlet Groups, all of the oth er outlet s a re the UPS outle ts , whi ch function as an out let group. All of the se groups can ind ependentl y t urn of f, tu[...]

  • Page 11

    9 Smart- UPS X 7 50/1000/1500 VA 12 0/230 Va c Rack - Mount 2 U Mode l specific c ontrollable outlet g roups  Controll able Outlet Gro up(s )  UPS outlets 750 V A 120 V ac 1000 V A 120/ 230 V ac 1500 V A 120/ 230 V ac su04 36a s u043 8a su 0 435a su 0437 a su04 88a su 0 487a[...]

  • Page 12

    Smart-UPS X 750/10 00/1 500 VA 120/230 Vac Rack-Mount 2U 10 Usin g the contr ollable outl et groups and U PS outl et s The UPS outlet s fu nct ion as a master switc h. T hey t urn on first when power is app lie d, shut of f l as t when there is a power out age and ba ttery runtim e ha s be en ex haus t ed. The UPS outlet s mus t be turne d o n for [...]

  • Page 13

    11 Smart -UPS X 7 50/1000/ 1500 VA 120/230 Va c Rack -Mount 2 U Custom ize the c ontrollab le outlet gro up s and the U PS ou tlet s Us e th e Control menus to ch ange the contr ollabl e out let groups and t he UP S outle t settin gs. Function Factor y Default Option s Descr ip tio n Name S tring Outlet Group Outle t Group 1 Ed it t hese name s usi[...]

  • Page 14

    Smart-UPS X 750/10 00/1 500 VA 120/230 Vac Rack-Mount 2U 12 N etw ork Ma na ge me nt C ard Set ti ng s These s e tt ings ar e availab le only on u nits tha t have a Network Manag ement Card ( NMC) and a re set i n t he factory . These set tings can only be modifi ed using an ext ern al interfac e, like the NMC web interfa ce. • NMC IP Addr ess Mo[...]

  • Page 15

    13 Smart -UPS X 7 50/1000/ 1500 VA 120/230 Va c Rack -Mount 2 U Emergen cy Power Of f Ov ervi ew The E merge nc y Powe r Off (EPO) op tion i s a sa fety feat ure that will i m mediat e ly disconnect all connected equipm e nt f rom ut ility po wer . The UPS will i m media tely s hut down a nd wi ll no t switc h to battery power . Conne ct ea ch UPS [...]

  • Page 16

    Smart-UPS X 750/10 00/1 500 VA 120/230 Vac Rack-Mount 2U 14 T rou bleshoot ing Pr oblem and Possible Cause Solution The UPS will no t turn on or ther e is no output The unit ha s not be en t urned on. Pres s the ON but ton on c e t o turn on the U PS. The UPS is not conne cted to u tility power . B e sure that th e power ca ble is sec urely co nnec[...]

  • Page 17

    15 Smart -UPS X 7 50/1000/ 1500 VA 120/230 Va c Rack -Mount 2 U All L EDs ar e ill uminated a n d the UPS is plugged in to a wall outle t The UPS has shut down and the batt ery has dischar ged fro m an exte nded o utage. None. The UPS wi ll re turn to normal op eration wh en the power i s re s tored and th e battery has a s uf fic ie nt char ge . T[...]

  • Page 18

    Smart-UPS X 750/10 00/1 500 VA 120/230 Vac Rack-Mount 2U 16 Se rvice If th e un it re q ui re s se r vi ce , d o no t retur n it to t he d e al er . Fol low th e se steps : 1. Review the T r oublesh ooting sect io n of the ma nual to e limin ate com mon pro b l ems. 2. If the proble m pe rsi s ts, contact APC by Schn eider Electr ic Customer S uppo[...]

  • Page 19

    17 Smart -UPS X 7 50/1000/ 1500 VA 120/230 Va c Rack -Mount 2 U T wo Y e ar Limit e d Factor y W a rr a nt y This war ranty a ppl ies onl y t o t he prod uct s you pur chase f or your us e in acco rda nce wit h t hi s manu al . T erm s o f warran ty Sch nei der Ele ctric IT ( SEIT) w ar rants it s produc ts to be f re e from d ef ects i n ma terial[...]

  • Page 20

    [...]

  • Page 21

    04/20 13 990- 3458 B APC by Schneide r Elect r i c World wide Cust omer Support Customer suppor t for this or any other APC by Schneider Ele ct r i c product is availabl e at no char ge in any of the followi ng wa ys: • V isit the APC by Sc hneider Electr ic W e b sit e to acces s documen ts in the APC by Schneide r Ele c tr ic Knowledg e Base an[...]