Go to page of
Similar user manuals
-
Switch
ATEN Technology CS-1758
68 pages 0.85 mb -
Switch
ATEN Technology KH1508
78 pages 2.78 mb -
Switch
ATEN Technology G-CS14
34 pages 0.44 mb -
Switch
ATEN Technology KL1508A
96 pages 5.49 mb -
Switch
ATEN Technology CS-228
41 pages 0.41 mb -
Switch
ATEN Technology CS9138
47 pages 1.17 mb -
Switch
ATEN Technology CS-1754
68 pages 0.85 mb -
Switch
ATEN Technology CE775
47 pages 1.25 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of ATEN Technology CS-1016, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ATEN Technology CS-1016 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of ATEN Technology CS-1016. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of ATEN Technology CS-1016 should contain:
- informations concerning technical data of ATEN Technology CS-1016
- name of the manufacturer and a year of construction of the ATEN Technology CS-1016 item
- rules of operation, control and maintenance of the ATEN Technology CS-1016 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ATEN Technology CS-1016 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ATEN Technology CS-1016, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ATEN Technology service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ATEN Technology CS-1016.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the ATEN Technology CS-1016 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
User Manual CS-1004 /CS-1008 /CS-1016 2001-01-13[...]
-
Page 2
2001-01-13[...]
-
Page 3
Packing List The complete Master View package consists of: M One Master View Pro KVM Switch (CS-1004, CS-1008, or CS-1016) M One Power Adapter M One User Manual Check to make sure that the unit was not damaged in shipping. If you encounter a problem, contact your dealer. Read this manual thoroughly and follow the installation and operation procedur[...]
-
Page 4
Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]
-
Page 5
Overview The Master View Pro KVM Switch is a control unit that allows access to mult iple computers from a single console (keyboard, monitor, and mouse). Bef ore the development of the Master View, the only way to control mult iple comput er configurations from a single console was through a complex and costly network system. Now, with the Mast er [...]
-
Page 6
Features w Daisy Chain Up To 31 Additional Units - Control Up to 512 PCs From a Single Console w No Software Required - Computer Selection via Front Panel Switches, Hotkeys or OSD (On Screen Display) w Quick View Scan Mode for Monitoring Selected PCs w PS/2 and Serial Mouse Emulation Provided For System Bootup w Console’s PS/2 Mouse Controls All [...]
-
Page 7
Hardware Requirements Console w A VGA, SVGA, or Mult isync monitor capable of the highest resolut ion that you will be using on any computer in the installation. w A PS/2 style mouse w A PS/2 style keyboard PC The following equipment must be installed on each computer: w A VGA, SVGA or Multisync card. w Either a 6-pin mini-DIN (PS/2 style), or DB-9[...]
-
Page 8
Unpacking CS-1016 Front View: * T The figure shows a CS-1016 model. The only difference between it and the other models is in the number of Port Selection Switches. 1. Status LEDs OnLine: Lights ORANGE to indicate that the PC attached to the corresponding port is up and running Selected: Lights GREEN to indicate the currently select ed port . 2. Po[...]
-
Page 9
CS-1016 Rear View: * T The figure shows a CS-1016 model. The only difference between it and the other models is in the number of Port Selection Switches. 1. Daisy Chain Section If you daisy chain units, the cables plug in here. 2. CPU Port Section The cables that link to the computers plug in here. 3. Power Jack The power adapter plugs in here. 4. [...]
-
Page 10
Installation Before you begin, make sure that power to all the devices (Master View Pro and PCs) you will be connecting up have been turned off. First Stage Installation In a Single Stage installation, there are no additional Mast er View ’ s daisy chained down from the first unit. To set up a single stage installat ion do the following: 1. Set S[...]
-
Page 11
6. Turn on the power to the Master View. Note: When you turn the unit On, it undergoes a Power On Self Test. If there is a problem, Port LEDs 1 - 4 flash repeatedly according to a pattern that indicates what the problem is: Pattern Indication LEDs 1 - 4 Flas h Simultaneously Internal RAM Memory E rror LEDs 1 - 4 Flash One A fter the Other External [...]
-
Page 12
4. Use Daisy chain cable set 2L-1700 (as described in the Hardware Requirements section), to connect from the Chai n Out Port of the parent Master View unit to the Chain In Port of the child Mast er View unit (F irst Station Out to Second Stat ion In, Second St at ion Out to Third St at ion In, et c. ). Note: You cannot use the Chain In Port of the[...]
-
Page 13
Operation Hot Plugging The Master View Pro supports hot plugging - components can be removed and added back into the installation by unplugging their cables from the CPU ports without the need to shut the unit down. In order for hot plugging to work properly, however, these procedures must be followed: w Hot Plugging CPU Ports: When hot plugging ca[...]
-
Page 14
Port Selection Controlling all the PCs connected up in your Master View installation from a single console could not be easier. Three methods are available that provide instant access to any PC on the chain: Manual; Hot Key ; and OSD. w Manual Simply press the appropriate Port Selection Switch on the Master View ’ s front panel. After you press t[...]
-
Page 15
Port ID Numbering Since each CPU Port on a Master View installation is assigned a unique Port ID, you can directly access any computer on any level of the installation using the Hot Key port selection method or from the OSD Main Menu by specifying the Port ID that the computer is connected to. The Port ID is made up of two part s: 1. The Station Nu[...]
-
Page 16
Port Numbering Tab le Port Numbering is summarized in the following table: Number of Digits Meaning 4 First two for Station Number; s econd two for Port Number 3 First two for Station Number; thi rd for Port Number 2 Port Number on the Currently Acti ve Station 1 Port Number on the Currently Acti ve Station 2001-01-13 12 CS-1004 / CS-1008 / CS-1016[...]
-
Page 17
Hot Key Operation Hotkey Port Selection Hot key port selection allows you to conveniently access any computer directly form the keyboard, in stead of having to manually select it with a Port Selection switch. Note: Make sure that DIP Switch 6 (locat ed on the Mast er View ’ s rear panel), is set to ON to enable the Hot Key feature under OSD. To s[...]
-
Page 18
Hot Key Broadcasting Commands to all attached PCs (to install software or shut down all the PCs, e.g.), can be broadcast from the console ’ s keyboard with the following Hot Key combinations: w [Ctrl] + [Alt] + [1] + [Enter] (t o init iat e the keyboard broadcast ) A Broadcast symbol appears in front of the St at ion ID (if the Port ID is current[...]
-
Page 19
OSD Operation On Screen Display (OSD), provides a menu driven interface to handle the computer switching procedure. Using OSD is a great deal more convenient - especially in large, daisy chained installations where it is difficult to keep track of which port a particular computer is attached to. All operations start from the OSD Main Menu. To pop u[...]
-
Page 20
OSD Main Menu Headings Heading Explanation SN-PN This col umn lists the Port ID numbers (Station Number - Port Number) for all the CPU ports on the i nstallation. The si mplest method to acces s a particular computer i s move the Highlight B ar to it, then press [Enter]. QV If a port has been selected for Quick V iew scanning (s ee F2 and F4, below[...]
-
Page 21
w F2 Scan: Pressing [F2] initiates Quick View Scanning , in which the OSD cycles through all the ports that are currently selected in the List view (see F3 , below), and displays each one for the amount of time set with the Scan Duration setting under the F6 Set function (see p. 19). When you want to stop at a particular location, press the [Spaceb[...]
-
Page 22
To make a choice move the Highlight Bar to the choice you want, then press [Enter]. An icon appears before the choice to indicate that it is the current ly selected one. Note: 1. You can access any port on any list by using the Navigation Keys then pressing [Enter]. or double clicking on it with the mouse. 2. If you select a port that does not have[...]
-
Page 23
w F6 Set: When you press [F6] a submenu appears that allows you to configure the OSD settings. To change a setting, use the Up and Down Arrow Keys or mouse to move the highlight bar to it, then press [Enter] or Double Click the left mouse button. Selecting Port ID Display Duration, Port ID Display Posit ion, Port ID Display Mode, and Scan Duration [...]
-
Page 24
Factory Default Settings The factory default settings are as follows: Setting Default Display Duration Always On Display Mode The Port Number plus the P ort Number Scan Duration 5 Seconds 2001-01-13 20 CS-1004 / CS-1008 / CS-1016 Us er Manual[...]
-
Page 25
OSD Security Features In order to prevent unauthorized access to the computers, the OSD provides two security features: Password; and Lock/Unlock Console. If a password is set , the console can only be locked/unlocked, by first specifying the password. When the console is locked, only the current monitor screen displays. Attempt s to input informat[...]
-
Page 26
Lock/Unlock Console: To lock/unlock the console: 1. Highlight this item, then press [Enter]. 2. If no password has been set, the system locks the console (if it is unlocked), or unlocks the console (it is locked). To acknowledge the change, the buzzer sounds, and one of the following messages displays on the screen for three seconds: "LOCK CON[...]
-
Page 27
Appendix Station Numbering Table The first Master View Pro (the one that the console connects to), is considered the First Station; the Master View Pro that daisy chains to it is considered the Second Station; the Master View Pro daisy chained to the Second Stat ion is considered the Third Station, etc. Swit ches 1 - 5 of the DI P Swit ch locat ed [...]
-
Page 28
Troubleshooting Symptom Possible Cause Action Pressing the HotKeys gets no response under OSD. DIP Swit ch 6 is set to OFF. Make sure that DIP S witch 6 is se t to ON. Pressing Hot Keys gets no response. The connection from the selected port to the target computer has been broken, or the PC is turned OFF. Check the Online LED for the sel ected port[...]
-
Page 29
Specifications Function CS-1004 CS-1008 CS-1016 Power Consumption DC 9V 500mA DC 9V 600mA DC 9V 800mA PC Connections Direct 4 8 16 Max. (via Daisy Chain) 128 256 512 Port Selection Front Panel Swi tches Hot Keys On Screen Display LEDs Power 1 On Line 4 8 16 Selecte d 4 8 16 Connectors Console 1 x 6 pin mini -DIN Female (PS/2 Sty le Mouse) 1 x 6 pin[...]
-
Page 30
Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interf erence, and (2) this device must accept any interference received, including int erf erence that may cause undesired operation. Limited Warranty IN NO EVEN[...]