Go to page of
Similar user manuals
-
Remote Starter
Audiovox 128-4117E
6 pages 0.03 mb -
Remote Starter
Audiovox 128-8128
24 pages 0.51 mb -
Remote Starter
Audiovox APS 687N
8 pages 0.04 mb -
Remote Starter
Audiovox APS-35-CL
19 pages 0.2 mb -
Remote Starter
Audiovox 128-8110
2 pages 0.04 mb -
Remote Starter
Audiovox 128-4864
19 pages 0.26 mb -
Remote Starter
Audiovox Platinum APS-875
16 pages 6.01 mb -
Remote Starter
Audiovox APS-700
24 pages 0.46 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Audiovox Prestige APS-905, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Audiovox Prestige APS-905 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Audiovox Prestige APS-905. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Audiovox Prestige APS-905 should contain:
- informations concerning technical data of Audiovox Prestige APS-905
- name of the manufacturer and a year of construction of the Audiovox Prestige APS-905 item
- rules of operation, control and maintenance of the Audiovox Prestige APS-905 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Audiovox Prestige APS-905 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Audiovox Prestige APS-905, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Audiovox service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Audiovox Prestige APS-905.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Audiovox Prestige APS-905 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
128-7410 1 of 20 Page 1 Kit Contents (1) Control Module (1) 5 Button One Way Flashlight Transmitter (1) 5 Button Two Way Dot Matrix Transceiver (1) On Glass Mount Superheterodyne Transceiver (1) Multi Pin Input/Output Harness (1) Six Pin Power Harness (1) Four Pin Alternate Ignition Harness (1) Trunk Release Output Harness (1) Auxiliary 4 Pin Outpu[...]
-
Page 2
128-7410 2 of 20 Page 2 SELECT ABLE FEA TURES The selectable features can be set manually as explained below , or with the RF feature programmer . T o set features using the RF programmer , follow the instructions packaged with the programmer . Factory default settings are indicated by bold text. Note : The method of manual override can either be s[...]
-
Page 3
128-7410 3 of 20 Page 3 T o program these selectable features; Action System Response Turn ignition on No response Press and release the valet switch 3 times 1 Chirp - LED 1 flash Within 3 seconds, turn ignition Off Then On Short chirp, then long chirp This Action Accesses Feature Bank 2 Alarm Selectable Features First Press and release the valet s[...]
-
Page 4
128-7410 4 of 20 Page 4 T o exit program mode, turn ignition of f, or press and release valet switch. RF Programmable Features Bank 3 Is Remote Start Selectable Features: T o program these selectable features; Turn ignition on No response Press and release the program switch 3 times 1 flash Within 3 seconds, turn ignition Off Then On, Off then On T[...]
-
Page 5
128-7410 5 of 20 Page 5 Action System Response Turn ignition on No response Press and release the valet switch 3 times 1 Chirp - LED 1 flash Within 3 seconds, turn ignition Off, On, Off, On Short chirp, then 2 long chirps This Action Accesses Feature Bank 3 Remote Start Selectable Features First Press the valet switch one time Not Available on this[...]
-
Page 6
128-7410 6 of 20 Page 6 This Remote Start/Keyless Entry System is designed for use with Automatic T ransmission Vehicles Only! The unit provides wait to start input for glow plug pre-heat which will be used for all diesel applications. If this wire is not connected, then the unit will remain in the Gasoline mode setting, which will crank the car wh[...]
-
Page 7
128-7410 7 of 20 Page 7 THE TRANSCEIVER/ANTENNA ASSEMBL Y : The Superheterodyne T ransceiver Antenna Assembly provided with this unit allows routing from below the dash- board for maximum operating range. Choose a location above the belt line (dashboard) of the vehicle for best reception. Special considerations must be made for windshield glass as [...]
-
Page 8
128-7410 8 of 20 Page 8 Failure to connect this wire to the ignition switch side of the neutral safety switch can result in personal injury and property damage. SEE NEUTRAL ST ART SAFETY TEST FOR FURTHER DET AILS. BLUE WIRE: Ignition 1 Output Connect this wire to the ignition 1 wire from the ignition switch. This wire will show +12 volts when the i[...]
-
Page 9
128-7410 9 of 20 Page 9 on + 12 volt source which will supply + 12 volt power to the additional ignition output, (Pink), wire. PINK Wire: Additional Ignition Output This wire can be used as an additional + 12 Volt ignition output supplied by the Red/Black wire. This output can be selected to be on or off during the start cycle. (See feature bank 3 [...]
-
Page 10
128-7410 10 of 20 Page 10 If the vehicle has a factory installed hood pin switch and that switch provides + 12 Volts to an under hood light, the Brown wire can be connected to the existing pin switch. BROWN w/ BLACK Tracer Wire: Positive Inhibit Input 2 Any time + 12 Volts is applied to the Brown w/ Black tracer wire, the Remote Starter will stop o[...]
-
Page 11
128-7410 11 of 20 Page 11 LIGHT BLUE Wire: Ground Output While Running. This wire provides a 300mA ground output that becomes active 3 seconds before the Remote Start Unit initializes, and remains grounded while running plus an additional 4 seconds after the Remote Start Unit turns off. In all of the applications described below , a relay will be r[...]
-
Page 12
128-7410 12 of 20 Page 12 Green/Orange Wire: T ach Sensor Input This wire will continually monitor the engine tach rate while the unit is under power of the Remote Start module. This wire will be routed to the vehicle ECM tach input or through the firewall into the engine compartment and connect to the negative side of the ignition coil. This Remot[...]
-
Page 13
128-7410 13 of 20 Page 13 NOTE: The outputs above are low current outputs and must be used with a relay if the circuit's requirement is more than 300 mA. 2 Pin Door Lock/Unlock Harness: (White Connector) The Red & Green Door Lock/Unlock output wires provide either a pulsed ground or pulsed + 12 volts to control the vehicle door lock / unlo[...]
-
Page 14
128-7410 14 of 20 Page 14 Resistive Circuits, As W ell As 4 W ire Polarity Reversal and 5 W ire Alternating 12 V olt Door Lock Control Circuits These applications require the use of additional components which may include relays, fixed resistors, or for convenience, the AS 9159 Door Lock Interface. Refer to the AUDIOVOX Door Lock Wiring Supplement [...]
-
Page 15
128-7410 15 of 20 Page 15 3. Diagnostics: 1. Enter Bank 3 and turn on selectable feature # 9 as described on the front pages of this manual. 2. Press and hold the program push-button switch on, then turn the ignition key to the "ON" position. 3. The lights will flash and the number of flashes will indicate the reason for shutdown on the l[...]
-
Page 16
128-7410 16 of 20 Page 16 MANUAL SHUT DOWN / ENABLE CIRCUIT : The intent of the manual shut down / enable circuit is to allow the vehicle operator to prevent operation of the Remote Start Unit regardless of the RF transmitter operation. T o test the integrity of the manual shut down / enable circuit: 1. Place the control switch in the on (Closed T [...]
-
Page 17
128-7410 17 of 20 Page 17 addition of a 4000 series diode. Shown is a typical GM Park/Neutral ECM input circuit. T o connect the Audiovox remote start u nit to the GM Park / Neutral ECM input: 1. Locate the Orange / Black reference wire in the "C2" connector found at the ECM in GM B Body vehicles or , locate the equiva lent reference wire[...]
-
Page 18
128-7410 18 of 20 Page 18 F . Connect terminal #86 of the relay to a fused +12 volt constant battery source. G. Connect terminal #87 of the relay to the Chime Module side of the previously cut wire in step D. H. Connect terminal #85 of the relay to the Drivers Door side of the pin switch wire previously cut in step B. METHOD 1 NOTE: A second 4002 s[...]
-
Page 19
128-7410 19 of 20 Page 19 AFTER THE CONNECTION OF THE NEUTRAL ST ART SAFETY WIRE AS INDICA TED IN ANY OF THE PREVIOUS AL TERNA TE CONFIGURA TIONS, THIS CIRCUIT MUST BE TESTED FOR OPERA TION. Retest by following the steps outlined in the NEUTRAL ST ART SAFETY TEST shown in this manual. 4 Pin Upgrade T elematic Module: Red = + 5 V olts, Black = Groun[...]
-
Page 20
128-7410 20 of 20 Page 20 © 2005 Audiovox Electronics Corp., Hauppauge, NY 1 1788 128-7410[...]