A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Axor 04134XX0, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Axor 04134XX0 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Axor 04134XX0. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Axor 04134XX0 should contain:
- informations concerning technical data of Axor 04134XX0
- name of the manufacturer and a year of construction of the Axor 04134XX0 item
- rules of operation, control and maintenance of the Axor 04134XX0 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Axor 04134XX0 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Axor 04134XX0, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Axor service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Axor 04134XX0.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Axor 04134XX0 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Metris S 04135XX0 Metris S 04126XX0 T alis S 04136XX0 T alis S 04127XX0 Focus S 04137XX0 Focus S 04128XX0 Solaris E 04138XX0 Solaris E 04129XX0 Allegro E 04139XX0 Allegro E 04130XX0 Swing C 04143XX0 Swing C 04134XX0 Metro E 04140XX0 Metro E 04131XX0 Installation Instructions / W arranty[...]
-
Page 2
2 T wo-hole thermostatic tub filler -- requires rough 04125181 04135XX0 04136XX0 04137XX0 04138XX0 04139XX0 04140XX0 04143XX0[...]
-
Page 3
3 Three-hole thermostatic tub filler -- requires rough 04124181 04129XX0 04128XX0 04127XX0 04126XX0[...]
-
Page 4
4 T echnical Information Recommended water pressure 45 - 72 psi Recommended hot water temp. 120 � - 140 � F* Max. hot water temp 165 � F* Max. flow rate 8 gpm Max. flow rate – handshower 2.5 gpm Safety stop 100° F *Please know and follow all applicable local plumbing codes when setting the temperature on the water heater . Installation Con[...]
-
Page 5
5 Install the valve trim Push the escutcheon over the valve. Install the handle. T ighten the screw with a 3 mm Allen wrench. The screw must engage the slot on the cartridge. Justify the handle. Set the high temperature limit stop. Push the spout sealing ring firmly into the spout adapter (1). Push the escutcheon and spout over the adapter and seal[...]
-
Page 6
6 Install the handshower Pull the end of the handshower hose from the holder . Push the escutcheon over the end of the hose. Push the elbow firmly over one end of the handshower hose. T ighten the hose nut. Thread the hose down through the handshower holder escutcheon and handshower holder . T ighten the escutcheon over the handshower holder . Plac[...]
-
Page 7
7 Set the high temperature limit stop T urn the water on to the tub spout or handshower . Use a 3 mm Allen wrench to loosen the handle screw . Remove the handle from the valve. Carefully remove the retainer clip and the limit stop ring. T urn the temperature control stem until the water is the desired high temperature, usually 110°F* . T urn the s[...]
-
Page 8
8 Justify the handle T urn the water on to the tub spout or handshower . Place a thermometer in the water stream. T ur n the temperature control knob until the output wa- ter temperature is 100°F . T urn the water off. Install the stop ring so that it is against the stop -- you should not be able to turn the stem fur ther counter-clockwise. Instal[...]
-
Page 9
9 Loosen the handle screw with a 3 mm Allen wrench. Remove the handle. Hold the handle lever in one hand. With the other hand, turn the temperature control knob until the 100° mark is next to the indexing mark on the handle. Install the handle on the valve. T ighten the screw .[...]
-
Page 10
10 User Instructions - ThermoBalance valve T urn the lever clockwise to send the water to one function, counter-clockwise to send the water to the second function. The center position is off. T urn the temperature control knob clockwise to make the water cooler . T urn the knob counter-clockwise to make the water warmer . The knob will stop at the [...]
-
Page 11
11 Maintenance: Clean the filters T urn off the water at the main before opening the valve. Remove the handle and escutcheon. Rinse the handshower with clear water . Install the handshower . T urn on the water and flush the hand- shower for at least one minute. If scale deposits build up on the spray face, pour about ¾" of a commercial scale [...]
-
Page 12
12 Install the escutcheon. Justify the handle. Rinse the debris from the filters, using a soft toothbrush if necessar y . Do not at- tempt to remove the screens. Lubricate the o-rings with white plumbers grease. Hold the stop unit steady . Install the ther- mostatic cartridge. Failure to hold the stop unit steady may result in damage to the ceramic[...]
-
Page 13
13 Replacement parts 1 2 6 4 5 3 7 8 12 13 14 15 16 17 18 8 8 8 8 8 8 12 12 12 12 14 14 14 15 15 15 15 13 13 16[...]
-
Page 14
14 1 Solaris E handle 88530XX0 2 T alis S handle 88549XX0 3 C handle 88610XX0 4 Metris S handle 88713XX0 5 Focus S handle 88714XX0 6 Allegro E handle 88719XX0 7 Metro E handle 88721XX0 8 handle escutcheon 88734XX0 9 elbow 28071XX0 10 handshower escutcheon 97159XX0 11 check valve 94074000 12 spout sealing ring 88512000 13 aerator 13956XX0 14 spout e[...]
-
Page 15
15 Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada. WHO IS COVERED BY [...]
-
Page 16
16 Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770-360-9880 • Fax 770-360-9887 www .hansgrohe-usa.com US - Installation Instructions • Part No. 90490001 • Revised 12/2008 maintenance, misuse, abuse, negligence, accident or alteration, or (2) the use of abrasive or caustic cleaning agents or “no-rinse” c[...]